In-Situ Sample Preparation and High-Resolution SEM-STEM Analysis

Author(s):  
Richard J. Young ◽  
Michael P. Bernas ◽  
Mary V. Moore ◽  
Young-Chung Wang ◽  
Jay P. Jordan ◽  
...  

Abstract The dual-beam system, which combines a high-resolution scanning electron microscope (SEM) with a focused ion beam (FIB), allows sample preparation, imaging, and analysis to be accomplished in a single tool. This paper discusses how scanning transmission electron microscopy (STEM) with the electron beam enhances the analysis capabilities of the dualbeam. In particular, it shows how, using the combination of in-situ sample preparation and integrated SEM-STEM imaging, more failure analysis and characterization problems can be solved in the dual-beam without needing to use the Ångstrom-level capabilities of the transmission electron microscope (TEM).

Author(s):  
R.J. Young ◽  
A. Buxbaum ◽  
B. Peterson ◽  
R. Schampers

Abstract Scanning transmission electron microscopy with scanning electron microscopes (SEM-STEM) has become increasing used in both SEM and dual-beam focused ion beam (FIB)-SEM systems. This paper describes modeling undertaken to simulate the contrast seen in such images. Such modeling provides the ability to help understand and optimize imaging conditions and also support improved sample preparation techniques.


Author(s):  
Corey Senowitz ◽  
Hieu Nguyen ◽  
Ruby Vollrath ◽  
Caiwen Yuan ◽  
Fati Rassolzadeh ◽  
...  

Abstract The modern scanning transmission electron microscope (S/TEM) has become a key technology and is heavily utilized in advanced failure analysis (FA) labs. It is well equipped to analyze semiconductor device failures, even for the latest process technology nodes (20nm or less). However, the typical sample preparation process flow utilizes a dual beam focused ion beam (FIB) microscope for sample preparation, with the final sample end-pointing monitored using the scanning electron microscope (SEM) column. At the latest technology nodes, defect sizes can be on the order of the resolution limit for the SEM column. Passive voltage contrast (PVC) is an established FA technique for integrated circuit (IC) FA which can compensate for this resolution deficiency in some cases. In this paper, PVC is applied to end-pointing cross-sectional S/TEM samples on the structure or defect of interest to address the SEM resolution limitation.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


2011 ◽  
Vol 17 (6) ◽  
pp. 889-895 ◽  
Author(s):  
Lynne M. Gignac ◽  
Surbhi Mittal ◽  
Sarunya Bangsaruntip ◽  
Guy M. Cohen ◽  
Jeffrey W. Sleight

AbstractThe ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.


Author(s):  
Julie Schuchman ◽  
Julie Willis

Abstract This paper deals primarily with the difficulties and solutions to scanning transmission electron microscope (STEM) sample preparation by dual beam focused ion beam. Approximately twenty major challenges were encountered spanning hardware, software, and material sample preparation. The main focus is upon the variety of challenges which are encountered in trying to implement automated STEM and TEM sample fabrication with minimal operator input and the engineering solutions implemented to overcome these challenges. The automated STEM script has evolved significantly from the first generation attempt and is described in more detail in this paper. The mechanical, software, and materials challenges encountered are also presented. The paper highlights a mechanical issue with the ion aperture motor mechanism, which required extensive troubleshooting to fully diagnose and correct. A long standing software routine had to be modified to fully enable script automation by extending the beam dwell time of the automatic brightness contrast routine.


2007 ◽  
Vol 1020 ◽  
Author(s):  
Debbie J Stokes ◽  
Laurent Roussel ◽  
Oliver Wilhelmi ◽  
Lucille A Giannuzzi ◽  
Dominique HW Hubert

AbstractCombined focused ion beam (FIB) and scanning electron microscopy (SEM) methods are becoming increasingly important for nano-materials applications as we continue to develop ways to exploit the complex interplay between primary ion and electron beams and the substrate, in addition to the various subtle relationships with gaseous intermediaries.We demonstrate some of the recent progress that has been made concerning FIB SEM processing of both conductive and insulating materials for state-of-the-art nanofabrication and prototyping and superior-quality specimen preparation for ultra-high resolution scanning transmission electron microscopy (STEM) and transmission electron microscopy (TEM) imaging and related in situ nanoanalysis techniques.


Author(s):  
Romaneh Jalilian ◽  
David Mudd ◽  
Neil Torrez ◽  
Jose Rivera ◽  
Mehdi M. Yazdanpanah ◽  
...  

Abstract The sample preparation for transmission electron microscope can be done using a method known as "lift-out". This paper demonstrates a method of using a silver-gallium nanoneedle array for a quicker sharpening process of tungsten probes with better sample viewing, covering the fabrication steps and performance of needle-tipped probes for lift-out process. First, an array of high aspect ratio silver-gallium nanoneedles was fabricated and coated to improve their conductivity and strength. Then, the nanoneedles were welded to a regular tungsten probe in the focused ion beam system at the desired angle, and used as a sharp probe for lift-out. The paper demonstrates the superior mechanical properties of crystalline silver-gallium metallic nanoneedles. Finally, a weldless lift-out process is described whereby a nano-fork gripper was fabricated by attaching two nanoneedles to a tungsten probe.


2010 ◽  
Vol 16 (S2) ◽  
pp. 214-215
Author(s):  
T Tanigaki ◽  
K Ito ◽  
K Nakamura ◽  
Y Nagakubo ◽  
J Azuma ◽  
...  

Extended abstract of a paper presented at Microscopy and Microanalysis 2010 in Portland, Oregon, USA, August 1 – August 5, 2010.


2016 ◽  
Vol 61 (2) ◽  
pp. 535-542 ◽  
Author(s):  
A. Kruk ◽  
G. Cempura ◽  
S. Lech ◽  
A. Czyrska -Filemonowicz

Abstract Allvac 718Plus (718Plus) is a high strength, corrosion resistant nickel- based superalloy used for application in power generation, aeronautics and aerospace industry. The 718Plus microstructure consists of a γ matrix with γ’-Ni3(Al,Ti) and some δ- Ni3Nb phases as well as lamellar particles (η-Ni3Ti, η*-Ni6AlNb or Ni6(Al,Ti)Nb) precipitated at the grain boundaries. The primary strengthening mechanism for this alloy is a precipitation hardening, therefore size and distribution of precipitates are critical for the performance of the alloy. The aim of this study was to characterize precipitates in the 718Plus superalloy using Scanning Transmission Electron Microscope combined with Energy Dispersive X-ray Spectroscopy (STEM-EDX) and Focused Ion Beam Scanning Electron Microscope (FIB-SEM). The STEM-EDX and FIB-SEM tomography techniques were used for 3D imaging and metrology of the precipitates. Transmission electron microscopy and EDX spectroscopy were used to reveal details of the 718Plus microstructure and allow determine chemical composition of the phases. The study showed that electron tomography techniques permit to obtain complementary information about microstructural features (precipitates size, shape and their 3D distribution) in the reconstructed volume with comparison to conventional particle analysis methods, e.g. quantitative TEM and SEM metallography


Sign in / Sign up

Export Citation Format

Share Document