Change detection in sparse repeat CT scans with non-rigid deformations

2021 ◽  
pp. 1-21
Author(s):  
Naomi Shamul ◽  
Leo Joskowicz

BACKGROUND: Detecting and interpreting changes in the images of follow-up CT scans by the clinicians is often time-consuming and error-prone due to changes in patient position and non-rigid anatomy deformations. Thus, reconstructed repeat scan images are required, precluding reduced dose sparse-view repeat scanning. OBJECTIVE: To develop a method to automatically detect changes in a region of interest of sparse-view repeat CT scans in the presence of non-rigid deformations of the patient’s anatomy without reconstructing the original images. METHODS: The proposed method uses the sparse sinogram data of two CT scans to distinguish between genuine changes in the repeat scan and differences due to non-rigid anatomic deformations. First, size and contrast level of the changed regions are estimated from the difference between the scans’ sinogram data. The estimated types of changes in the repeat scan help optimize the method’s parameter values. Two scans are then aligned using Radon space non-rigid registration. Rays which crossed changes in the ROI are detected and back-projected onto image space in a two-phase procedure. These rays form a likelihood map from which the binary changed region map is computed. RESULTS: Experimental studies on four pairs of clinical lung and liver CT scans with simulated changed regions yield a mean changed region recall rate >  86%and a mean precision rate >  83%when detecting large changes with low contrast, and high contrast changes, even when small. The new method outperforms image space methods using prior image constrained compressed sensing (PICCS) reconstruction, particularly for small, low contrast changes (recall = 15.8%, precision = 94.7%). CONCLUSION: Our method for automatic change detection in sparse-view repeat CT scans with non-rigid deformations may assist radiologists by highlighting the changed regions and may obviate the need for a high-quality repeat scan image when no changes are detected.

2020 ◽  
Vol 28 (6) ◽  
pp. 1069-1089
Author(s):  
Zeev Adelman ◽  
Leo Joskowicz

BACKGROUND: Repeat CT scanning is ubiquitous in many clinical situations, e.g. to follow disease progression, to evaluate treatment efficacy, and to monitor interventional CT procedures. However, it incurs in cumulative radiation to the patient which can be significantly reduced by using a region of interest (ROI) and the existing baseline scan. OBJECTIVE: To obtain a high-quality reconstruction of a ROI with a significantly reduced X-ray radiation dosage that accounts for deformations. METHODS: We present a new method for deformable registration and image reconstruction inside an ROI in repeat CT scans with a highly reduced X-ray radiation dose based on sparse scanning. Our method uses the existing baseline scan data, a user-defined ROI, and a new sparse repeat scan to compute a high-quality repeat scan ROI image with a significantly reduced radiation dose. Our method first performs rigid registration between the densely scanned baseline and the sparsely scanned repeat CT scans followed by deformable registration with a low-order parametric model, both in 3D Radon space and without reconstructing the repeat scan image. It then reconstructs the repeat scan ROI without computing the entire repeat scan image. RESULTS: Our experimental results on clinical lung and liver CT scans yield a mean × 14 computation speedup and a × 7.6-12.5 radiation dose reduction, with a minor image quality loss of 0.0157 in the NRMSE metric. CONCLUSION: Our method is considerably faster than existing methods, thereby enabling intraoperative online repeat scanning that it is accurate and accounts for position, deformation, and structure changes at a fraction of the radiation dose required by existing methods.


Author(s):  
John P. Langmore ◽  
Brian D. Athey

Although electron diffraction indicates better than 0.3nm preservation of biological structure in vitreous ice, the imaging of molecules in ice is limited by low contrast. Thus, low-dose images of frozen-hydrated molecules have significantly more noise than images of air-dried or negatively-stained molecules. We have addressed the question of the origins of this loss of contrast. One unavoidable effect is the reduction in scattering contrast between a molecule and the background. In effect, the difference in scattering power between a molecule and its background is 2-5 times less in a layer of ice than in vacuum or negative stain. A second, previously unrecognized, effect is the large, incoherent background of inelastic scattering from the ice. This background reduces both scattering and phase contrast by an additional factor of about 3, as shown in this paper. We have used energy filtration on the Zeiss EM902 in order to eliminate this second effect, and also increase scattering contrast in bright-field and dark-field.


2021 ◽  
Vol 11 (9) ◽  
pp. 4251
Author(s):  
Jinsong Zhang ◽  
Shuai Zhang ◽  
Jianhua Zhang ◽  
Zhiliang Wang

In the digital microfluidic experiments, the droplet characteristics and flow patterns are generally identified and predicted by the empirical methods, which are difficult to process a large amount of data mining. In addition, due to the existence of inevitable human invention, the inconsistent judgment standards make the comparison between different experiments cumbersome and almost impossible. In this paper, we tried to use machine learning to build algorithms that could automatically identify, judge, and predict flow patterns and droplet characteristics, so that the empirical judgment was transferred to be an intelligent process. The difference on the usual machine learning algorithms, a generalized variable system was introduced to describe the different geometry configurations of the digital microfluidics. Specifically, Buckingham’s theorem had been adopted to obtain multiple groups of dimensionless numbers as the input variables of machine learning algorithms. Through the verification of the algorithms, the SVM and BPNN algorithms had classified and predicted the different flow patterns and droplet characteristics (the length and frequency) successfully. By comparing with the primitive parameters system, the dimensionless numbers system was superior in the predictive capability. The traditional dimensionless numbers selected for the machine learning algorithms should have physical meanings strongly rather than mathematical meanings. The machine learning algorithms applying the dimensionless numbers had declined the dimensionality of the system and the amount of computation and not lose the information of primitive parameters.


2005 ◽  
Vol 127 (4) ◽  
pp. 755-762 ◽  
Author(s):  
Yasushi Tatebayashi ◽  
Kazuhiro Tanaka ◽  
Toshio Kobayashi

The authors have been investigating the various characteristics of screw-type centrifugal pumps, such as pressure fluctuations in impellers, flow patterns in volute casings, and pump performance in air-water two-phase flow conditions. During these investigations, numerical results of our investigations made it clear that three back flow regions existed in this type of pump. Among these, the back flow from the volute casing toward the impeller outlet was the most influential on the pump performance. Thus the most important factor to achieve higher pump performance was to reduce the influence of this back flow. One simple method was proposed to obtain the restraint of back flow and so as to improve the pump performance. This method was to set up a ringlike wall at the suction cover casing between the impeller outlet and the volute casing. Its effects on the flow pattern and the pump performance have been discussed and clarified to compare the calculated results with experimental results done under two conditions, namely, one with and one without this ring-type wall. The influence of wall’s height on the pump head was investigated by numerical simulations. In addition, the difference due to the wall’s effect was clarified to compare its effects on two kinds of volute casing. From the results obtained it can be said that restraining the back flow of such pumps was very important to achieve higher pump performance. Furthermore, another method was suggested to restrain back flow effectively. This method was to attach a wall at the trailing edge of impeller. This method was very useful for avoiding the congestion of solids because this wall was smaller than that used in the first method. The influence of these factors on the pump performance was also discussed by comparing simulated calculations with actual experiments.


The present paper describes an investigation of diffusion in the solid state. Previous experimental work has been confined to the case in which the free energy of a mixture is a minimum for the single-phase state, and diffusion decreases local differences of concentration. This may be called ‘diffusion downhill’. However, it is possible for the free energy to be a minimum for the two-phase state; diffusion may then increase differences of concentration; and so may be called ‘diffusion uphill’. Becker (1937) has proposed a simple theoretical treatment of these two types of diffusion in a binary alloy. The present paper describes an experimental test of this theory, using the unusual properties of the alloy Cu 4 FeNi 3 . This alloy is single phase above 800° C and two-phase at lower temperatures, both the phases being face-centred cubic; the essential difference between the two phases is their content of copper. On dissociating from one phase into two the alloy develops a series of intermediate structures showing striking X-ray patterns which are very sensitive to changes of structure. It was found possible to utilize these results for a quantitative study of diffusion ‘uphill’ and ‘downhill’ in the alloy. The experimental results, which can be expressed very simply, are in fair agreement with conclusions drawn from Becker’s theory. It was found that Fick’s equation, dc / dt = D d2c / dx2 , can, within the limits of error, be applied in all cases, with the modification that c denotes the difference of the measured copper concentration from its equilibrium value. The theory postulates that D is the product of two factors, of which one is D 0f the coefficient of diffusion that would be measured if the alloy were an ideal solid solution. The theory is able to calculate D/D 0 , if only in first approximation, and the experiments confirm this calculation. It was found that in most cases the speed of diffusion—‘uphill’ or ‘downhill’—has the order of magnitude of D 0 . * Now with British Electrical Research Association.


2021 ◽  
pp. 197140092110497
Author(s):  
Tetsuya Hashimoto ◽  
Takenobu Kunieda ◽  
Tristan Honda ◽  
Fabien Scalzo ◽  
Latisha K Sharma ◽  
...  

Background The potential heterogeneity in occlusive thrombi caused by in situ propagation by secondary thrombosis after embolic occlusion could obscure the characteristics of original thrombi, preventing the clarification of a specific thrombus signature for the etiology of ischemic stroke. We aimed to investigate the heterogeneity of occlusive thrombi by pretreatment imaging. Methods Among consecutive stroke patients with acute embolic anterior circulation large vessel occlusion treated with thrombectomy, we retrospectively reviewed 104 patients with visible occlusive thrombi on pretreatment non-contrast computed tomography admitted from January 2015 to December 2018. A region of interest was set on the whole thrombus on non-contrast computed tomography under the guidance of computed tomography angiography. The region of interest was divided equally into the proximal and distal segments and the difference in Hounsfield unit densities between the two segments was calculated. Results Hounsfield unit density in the proximal segment was higher than that in the distal segment (mean difference 4.45; p < 0.001), regardless of stroke subtypes. On multivariate analysis, thrombus length was positively correlated (β = 0.25; p < 0.001) and time from last-known-well to imaging was inversely correlated (β = −0.0041; p = 0.002) with the difference in Hounsfield unit densities between the proximal and distal segments. Conclusions The difference in density between the proximal and distal segments increased as thrombi became longer and decreased as thrombi became older after embolic occlusion. This time/length-dependent thrombus heterogeneity between the two segments is suggestive of secondary thrombosis initially occurring on the proximal side of the occlusion.


Author(s):  
Jwalant S. Mehta ◽  
Kirsten Hodgson ◽  
Lu Yiping ◽  
James Swee Beng Kho ◽  
Ravindra Thimmaiah ◽  
...  

Aims To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Methods Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)). Results There were more ionizing radiation-based imaging events and higher radiation dose exposures in the surgical group than in the non-surgical group (p < 0.001). The difference in effective dose for children between the surgical and non-surgical groups was statistically significant, the surgical group being significantly higher (p < 0.001). This led to a higher estimated risk of cancer induction for the surgical group (1:222 surgical vs 1:1,418 non-surgical). However, the dose difference for adults was not statistically different between the surgical and non-surgical groups. In all cases the effective dose received by all cohorts was significantly higher than that from exposure to natural background radiation. Conclusion The treatment of spinal deformity is radiation-heavy. The dose exposure is several times higher when surgical treatment is undertaken. Clinicians should be aware of this and review their practices in order to reduce the radiation dose where possible.


2021 ◽  
pp. 014544552110540
Author(s):  
Nihal Sen

The purpose of this study is to provide a brief introduction to effect size calculation in single-subject design studies, including a description of nonparametric and regression-based effect sizes. We then focus the rest of the tutorial on common regression-based methods used to calculate effect size in single-subject experimental studies. We start by first describing the difference between five regression-based methods (Gorsuch, White et al., Center et al., Allison and Gorman, Huitema and McKean). This is followed by an example using the five regression-based effect size methods and a demonstration how these methods can be applied using a sample data set. In this way, the question of how the values obtained from different effect size methods differ was answered. The specific regression models used in these five regression-based methods and how these models can be obtained from the SPSS program were shown. R2 values obtained from these five methods were converted to Cohen’s d value and compared in this study. The d values obtained from the same data set were estimated as 0.003, 0.357, 2.180, 3.470, and 2.108 for the Allison and Gorman, Gorsuch, White et al., Center et al., as well as for Huitema and McKean methods, respectively. A brief description of selected statistical programs available to conduct regression-based methods was given.


2020 ◽  
Vol 12 (11) ◽  
pp. 1746
Author(s):  
Salman Ahmadi ◽  
Saeid Homayouni

In this paper, we propose a novel approach based on the active contours model for change detection from synthetic aperture radar (SAR) images. In order to increase the accuracy of the proposed approach, a new operator was introduced to generate a difference image from the before and after change images. Then, a new model of active contours was developed for accurately detecting changed regions from the difference image. The proposed model extracts the changed areas as a target feature from the difference image based on training data from changed and unchanged regions. In this research, we used the Otsu histogram thresholding method to produce the training data automatically. In addition, the training data were updated in the process of minimizing the energy function of the model. To evaluate the accuracy of the model, we applied the proposed method to three benchmark SAR data sets. The proposed model obtains 84.65%, 87.07%, and 96.26% of the Kappa coefficient for Yellow River Estuary, Bern, and Ottawa sample data sets, respectively. These results demonstrated the effectiveness of the proposed approach compared to other methods. Another advantage of the proposed model is its high speed in comparison to the conventional methods.