scholarly journals Light-Assisted Enhancement of Gas Sensing Property for Micro-Nanostructure Electronic Device: A Mini Review

2021 ◽  
Vol 9 ◽  
Author(s):  
Zongtao Ma ◽  
Ziying Wang ◽  
Lingxiao Gao

In recent years, gas sensing electronic devices have always attracted wide attention in the field of environment, industry, aviation and others. In order to improve the gas sensing properties, many micro- and nano-fabrication technologies have been proposed and investigated to develop high-performance gas sensing devices. It is worth noting that light irradiation is an effective strategy to enhance gas sensitivity, shorten the response and recovery time, reduce operating temperature. In this review, firstly, the latest research advances of gas sensors based on different micro-nanostructure materials under UV light and visible light activation is introduced. Then, the gas sensing mechanism of light-assisted gas sensor is discussed in detail. Finally, this review describes the present application of gas sensors with improved properties under light activation assisted conditions and the perspective of their applications.

Nanomaterials ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 892
Author(s):  
Artem Chizhov ◽  
Marina Rumyantseva ◽  
Alexander Gaskov

The review deals with issues related to the principle of operation of resistive semiconductor gas sensors and the use of light activation instead of thermal heating when detecting gases. Information on the photoelectric and optical properties of nanocrystalline oxides SnO2, ZnO, In2O3, and WO3, which are the most widely used sensitive materials for semiconductor gas sensors, is presented. The activation of the gas sensitivity of semiconductor materials by both UV and visible light is considered. When activated by UV light, the typical approaches for creating materials are (i) the use of individual metal oxides, (ii) chemical modification with nanoparticles of noble metals and their oxides, (iii) and the creation of nanocomposite materials based on metal oxides. In the case of visible light activation, the approaches used to enhance the photo- and gas sensitivity of wide-gap metal oxides are (i) doping; (ii) spectral sensitization using dyes, narrow-gap semiconductor particles, and quantum dots; and (iii) addition of plasmon nanoparticles. Next, approaches to the description of the mechanism of the sensor response of semiconductor sensors under the action of light are considered.


2021 ◽  
Author(s):  
Zhihua Ying ◽  
Teng Zhang ◽  
Chao Feng ◽  
Fei Wen ◽  
Lili Li ◽  
...  

Abstract This present study reported a high-performance gas sensor, based on In2O3/ZnO composite material modified by polypeptides, with a high sensibility to NO2, where the In2O3/ZnO composite was prepared by a one-step hydrothermal method. A series of results through material characterization technologies showed the addition of polypeptides can effectively change the morphology and size of In2O3/ZnO crystals, and effectively improve the sensing performance of the gas sensors. Due to the single shape and small size, In2O3/ZnO composite modified by polypeptides increased the active sites on the surface. At the same time, the gas sensing properties of four different ratios of polypeptide-modified In2O3/ZnO gas sensors were tested. It was found that the In2O3/ZnO-10 material showed the highest response, excellent selectivity, and good stability at room temperature under UV light. In addition, the response of the In2O3/ZnO-10 gas sensor showed a strong linear relationship with the NO2 gas concentration. When the NO2 gas concentration was 20 ppm, the response time was as quick as 19s, and the recovery time was 57s. Finally, based on the obtained experimental characterization results and energy band structure analysis, a possible gas sensing mechanism is proposed.


Author(s):  
Priya Gupta ◽  
Savita Maurya ◽  
Narendra Kumar Pandey ◽  
Vernica Verma

: This review paper encompasses a study of metal-oxide and their composite based gas sensors used for the detection of ammonia (NH3) gas. Metal-oxide has come into view as an encouraging choice in the gas sensor industry. This review paper focuses on the ammonia sensing principle of the metal oxides. It also includes various approaches adopted for increasing the gas sensitivity of metal-oxide sensors. Increasing the sensitivity of the ammonia gas sensor includes size effects and doping by metal or other metal oxides which will change the microstructure and morphology of the metal oxides. Different parameters that affect the performances like sensitivity, stability, and selectivity of gas sensors are discussed in this paper. Performances of the most operated metal oxides with strengths and limitations in ammonia gas sensing application are reviewed. The challenges for the development of high sensitive and selective ammonia gas sensor are also discussed.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 783 ◽  
Author(s):  
Andrea Gaiardo ◽  
David Novel ◽  
Elia Scattolo ◽  
Michele Crivellari ◽  
Antonino Picciotto ◽  
...  

The substrate plays a key role in chemoresistive gas sensors. It acts as mechanical support for the sensing material, hosts the heating element and, also, aids the sensing material in signal transduction. In recent years, a significant improvement in the substrate production process has been achieved, thanks to the advances in micro- and nanofabrication for micro-electro-mechanical system (MEMS) technologies. In addition, the use of innovative materials and smaller low-power consumption silicon microheaters led to the development of high-performance gas sensors. Various heater layouts were investigated to optimize the temperature distribution on the membrane, and a suspended membrane configuration was exploited to avoid heat loss by conduction through the silicon bulk. However, there is a lack of comprehensive studies focused on predictive models for the optimization of the thermal and mechanical properties of a microheater. In this work, three microheater layouts in three membrane sizes were developed using the microfabrication process. The performance of these devices was evaluated to predict their thermal and mechanical behaviors by using both experimental and theoretical approaches. Finally, a statistical method was employed to cross-correlate the thermal predictive model and the mechanical failure analysis, aiming at microheater design optimization for gas-sensing applications.


Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 3947
Author(s):  
Wei Wang ◽  
Qinyi Zhang ◽  
Ruonan Lv ◽  
Dong Wu ◽  
Shunping Zhang

High performance formaldehyde gas sensors are widely needed for indoor air quality monitoring. A modified layer of zeolite on the surface of metal oxide semiconductors results in selectivity improvement to formaldehyde as gas sensors. However, there is insufficient knowledge on how the thickness of the zeolite layer affects the gas sensing properties. In this paper, ZSM-5 zeolite films were coated on the surface of the SnO2 gas sensors by the screen printing method. The thickness of ZSM-5 zeolite films was controlled by adjusting the numbers of screen printing layers. The influence of ZSM-5 film thickness on the performance of ZSM-5/SnO2 gas sensors was studied. The results showed that the ZSM-5/SnO2 gas sensors with a thickness of 19.5 μm greatly improved the selectivity to formaldehyde, and reduced the response to ethanol, acetone and benzene at 350 °C. The mechanism of the selectivity improvement to formaldehyde of the sensors was discussed.


Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 372
Author(s):  
Liyang Lin ◽  
Susu Chen ◽  
Tao Deng ◽  
Wen Zeng

The metal oxides/graphene nanocomposites have great application prospects in the fields of electrochemical energy storage and gas sensing detection. However, rational synthesis of such materials with good conductivity and electrochemical activity is the topical challenge for high-performance devices. Here, SnO2/graphene nanocomposite is taken as a typical example and develops a universal synthesis method that overcome these challenges and prepares the oxygen-deficient SnO2 hollow nanospheres/graphene (r-SnO2/GN) nanocomposite with excellent performance for supercapacitors and gas sensors. The electrode r-SnO2/GN exhibits specific capacitance of 947.4 F g−1 at a current density of 2 mA cm−2 and of 640.0 F g−1 even at 20 mA cm−2, showing remarkable rate capability. For gas-sensing application, the sensor r-SnO2/GN showed good sensitivity (~13.8 under 500 ppm) and short response/recovering time toward methane gas. These performance features make r-SnO2/GN nanocomposite a promising candidate for high-performance energy storage devices and gas sensors.


2021 ◽  
pp. 2151043
Author(s):  
Zijing Wang ◽  
Fen Wang ◽  
Angga Hermawan ◽  
Jianfeng Zhu ◽  
Shu Yin

Porous nitrogen-doped Ti3C2T[Formula: see text] MXene (N-TCT) with a three-dimensional network structure is synthesized via a simple sacrifice template method and then utilized as an acetone gas sensor. By introducing nitrogen atoms as heteroatoms into Ti3C2T[Formula: see text] nanosheets, some defects generate around the doped nitrogen atoms, which can greatly improve the surface hydrophilicity and adsorption capacity of Ti3C2T[Formula: see text] Mxene nanosheets. It resulted in the enhanced gas sensitivity, achieving a response value of about 36 ([Formula: see text]/[Formula: see text] × 100%) and excellent recovery time (9s) at 150[Formula: see text]C. Compared with the pure Ti3C2T[Formula: see text]-based gas sensor (381/92s), the response and recovery time are both obviously improved, and the response value increased by 3.5 times. The gas-sensing mechanism of the porous N-TCT is also discussed in detail. Based on the excellent gas sensitivity of porous N-TCT for highly responsive acetone detection at high temperatures, the strategy of nitrogen-doped two-dimensional nanomaterials can be extended to other nanomaterials to realize their potential applications.


RSC Advances ◽  
2017 ◽  
Vol 7 (63) ◽  
pp. 39859-39868 ◽  
Author(s):  
Shaofeng Shao ◽  
Yunyun Chen ◽  
Shenbei Huang ◽  
Fan Jiang ◽  
Yunfei Wang ◽  
...  

Pt/GQDs/TiO2 nanocomposite thin film-based gas sensors show tunable VOC sensing behaviour at room temperature under visible-light activation.


2017 ◽  
Vol 10 (03) ◽  
pp. 1750022 ◽  
Author(s):  
Mengying Xu ◽  
Zhidong Lin ◽  
Wenying Guo ◽  
Yuyuan Hong ◽  
Ping Fu ◽  
...  

Fe2(MoO4)3 nanoplates were prepared via a simple hydrothermal process. The average crystalline size of these nanoplates is 85.8[Formula: see text]nm. The sensor based on Fe2(MoO4)3 shows a high gas sensing performance to xylene. The response of Fe2(MoO4)3 sensor is 25.9–100[Formula: see text]ppm xylene at optimum operating temperature of 340[Formula: see text]C. The response and recovery times to 100[Formula: see text]ppm xylene are 4 and 10[Formula: see text]s, respectively. Furthermore, the Fe2(MoO4)3 sensor exhibits remarkable selectivity detection of xylene gas with negligible responses to toluene and benzene. Therefore, the Fe2(MoO4)3 is a promising material for the detection of xylene gas sensors.


Sensors ◽  
2020 ◽  
Vol 20 (20) ◽  
pp. 5910
Author(s):  
Andrea Gaiardo ◽  
Giulia Zonta ◽  
Sandro Gherardi ◽  
Cesare Malagù ◽  
Barbara Fabbri ◽  
...  

Among the various chemoresistive gas sensing properties studied so far, the sensing response reproducibility, i.e., the capability to reproduce a device with the same sensing performance, has been poorly investigated. However, the reproducibility of the gas sensing performance is of fundamental importance for the employment of these devices in on-field applications, and to demonstrate the reliability of the process development. This sensor property became crucial for the preparation of medical diagnostic tools, in which the use of specific chemoresistive gas sensors along with a dedicated algorithm can be used for screening diseases. In this work, the reproducibility of SmFeO3 perovskite-based gas sensors has been investigated. A set of four SmFeO3 devices, obtained from the same screen-printing deposition, have been tested in laboratory with both controlled concentrations of CO and biological fecal samples. The fecal samples tested were employed in the clinical validation protocol of a prototype for non-invasive colorectal cancer prescreening. Sensors showed a high reproducibility degree, with an error lower than 2% of the response value for the test with CO and lower than 6% for fecal samples. Finally, the reproducibility of the SmFeO3 sensor response and recovery times for fecal samples was also evaluated.


Sign in / Sign up

Export Citation Format

Share Document