scholarly journals Clinical Performance of the Xpert® CT/NG Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae: A Multicenter Evaluation in Chinese Urban Hospitals

Author(s):  
Yan Han ◽  
Mei-Qin Shi ◽  
Qing-Ping Jiang ◽  
Wen-Jing Le ◽  
Xiao-Lin Qin ◽  
...  

BackgroundWe aimed to evaluate the clinical performance of the GeneXpert® (Xpert) CT/NG assay for the detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) using urine and cervical swabs collected from patients in China.MethodsThis study was conducted from September 2016 to September 2018 in three Chinese urban hospitals. The results from the Xpert CT/NG test were compared to those from the Roche cobas® 4800 CT/NG test. Discordant results were confirmed by DNA sequence analysis.ResultsIn this study, 619 first void urine (FVU) specimens and 1,042 cervical swab specimens were included in the final dataset. There were no statistical differences between the results of the two tests for the detection of CT/NG in urine samples (p > 0.05), while a statistical difference was found in cervical swabs (p < 0.05). For CT detection, the sensitivity and specificity of the Xpert test were 100.0% (95%CI = 96.8–99.9) and 98.3% (95%CI = 96.6–99.2) for urine samples and 99.4% (95%CI = 96.5–100.0) and 98.6% (95%CI 97.5–99.2) for cervical swabs, respectively. For NG detection, the sensitivity and specificity of the Xpert test were 99.2% (95%CI = 94.9–100.0) and 100.0% (95%CI = 99.0–100.0) for urine and 100% (95%CI = 92.8–100.0) and 99.7% (95%CI = 99.0–99.9) for cervical swabs, respectively.ConclusionThe Xpert CT/NG test exhibited high sensitivity and specificity in the detection of CT and NG in both urine and cervical samples when compared to the reference results. The 90-min turnaround time for CT and NG detection at the point of care using Xpert may enable patients to receive treatment promptly.

Author(s):  
Paul C. Adamson ◽  
Jeffrey D. Klausner

Chlamydia trachomatis and Neisseria gonorrhoeae are two of the most often reported bacterial infections in the United States. The rectum and oropharynx are important anatomic sites of infection and can contribute to ongoing transmission. Nucleic acid amplification tests (NAATs) are the mainstays for the detection of C. trachomatis and N. gonorrhoeae infections owing to their high sensitivity and specificity. Several NAATs have been evaluated for testing in rectal and pharyngeal infections. A few assays recently received clearance by the Food and Drug Administration, including one point-of-care test. Those assays can be used for testing in symptomatic individuals, as well as for asymptomatic screening in certain patient populations. Routine screening for C. trachomatis in pharyngeal specimens is not recommended by the Centers for Disease Control and Prevention, though is often performed due to the use of multiplex assays. While expanding the types of settings for screening and using self-collected rectal and pharyngeal specimens can help to increase access and uptake of testing, additional research is needed to determine the potential benefits and costs associated with increased screening for rectal and pharyngeal C. trachomatis and N. gonorrhoeae infections on a population level.


2015 ◽  
Vol 88 (1) ◽  
pp. 33-37
Author(s):  
Alecsandra Iulia Grad ◽  
Mihaela Laura Vica ◽  
Horea Vladi Matei ◽  
Doru Lucian Grad ◽  
Ioan Coman ◽  
...  

Background and aim. Sexually transmitted infections are a very frequent and under-diagnosed cause of illness worldwide. A high number of detection methods and a large range of specimens in which sexually transmitted infections can be determined are available at the moment. Polymerase chain reaction performed on first void urine offers the advantage of being non-invasive, self-collectable and has high sensitivity and specificity. We looked to determine the frequency of Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, Mycoplasma hominis, Mycoplasma genitalium and Ureaplasma urealyticum in symptomatic and asymptomatic patients.Methods. Six sexually transmitted infections were determined in the first void urine of 15 symptomatic and asymptomatic patients by polymerase chain reaction. We used “Epicenter MasterPure™ Complete DNA and RNA Purification Kit” for the DNA purification and “Seeplex® STD6 ACE Detection” for the DNA amplification. The results were examined in UV light.Results. A number of 5 patients had positive results for Chlamydia trachomatis or Neisseria gonorrhoeae. Sexually transmitted infections are more frequent in men between 27 and 40 years old.Conclusions. Polymerase chain reaction is a good diagnostic tool for sexually transmitted infections because it has a high sensitivity and specificity. Chlamydia trachomatis is the most frequent sexually transmitted infection, followed by Neisseria gonorrhoeae.


Sexual Health ◽  
2019 ◽  
Vol 16 (4) ◽  
pp. 314 ◽  
Author(s):  
Claire C. Bristow ◽  
Sheldon R. Morris ◽  
Susan J. Little ◽  
Sanjay R. Mehta ◽  
Jeffrey D. Klausner

Background Most studies evaluating extragenital testing performance for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) detection by the Xpert® CT/NG show high per cent agreement with comparison assays; however, the precision around positive per cent agreement is low and thus the values that have been reported are not highly informative. Therefore, a systematic review was conducted and data from five studies were combined to better assess positive per cent agreement. Methods: The literature indexed on PubMed.gov was searched. Included studies were those that were an evaluation of the Xpert CT/NG assay with rectal and/or pharyngeal specimen types compared with another nucleic acid amplification test (NAAT), the Aptima transcription mediated amplification assay. A full Bayesian method was used for bivariate fixed-effect meta-analysis of positive and negative per cent agreement and pooled estimates (and 95% confidence intervals (CI)) were presented for each. Results: The pooled positive and negative per cent agreement for detection of CT in rectal specimens was 89.72% (95% CI: 84.97%, 93.64%) and 99.23% (95% CI: 98.74%, 99.60%), and in pharyngeal specimens, they were 89.96% (95% CI: 66.38%, 99.72%) and 99.62% (95% CI: 98.95%, 99.95%) respectively. For NG detection in rectal specimens, the pooled positive and negative per cent agreement was 92.75% (95% CI: 87.91%, 96.46%) and 99.75% (95% CI: 99.46%, 99.93%), and in pharyngeal specimens, they were 92.51% (95% CI: 85.84%, 97.18%) and 98.56% (95% CI: 97.69%, 99.23%) respectively. Conclusions: It was found that the Xpert CT/NG assay performed similarly to the Aptima transcription mediated amplification assay for the detection of CT and NG in extragenital specimens. The Xpert assay has the benefit of providing faster results at the point-of-care, thus reducing the turnaround time for results, potentially enabling same-day treatment.


2017 ◽  
Vol 94 (4) ◽  
pp. 293-297 ◽  
Author(s):  
David John Speers ◽  
I-Ly Joanna Chua ◽  
Justin Manuel ◽  
Lewis Marshall

ObjectivesScreening of men who have sex with men (MSM) for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) requires sampling from anorectal and pharyngeal sites in addition to urogenital sampling. Due to the cost of testing multiple anatomical sites individually testing of pooled specimens has potential merit. The Cepheid GeneXpert CT/NG assay (GeneXpert), which also has potential for point-of-care nucleic acid testing in the sexual health clinic, has not been assessed for pooled specimen testing.MethodsWe prospectively compared GeneXpert testing of pooled pharyngeal and rectal swabs with urine samples to standard of care testing of individual specimens from 107 participants using the Roche cobas 4800 CT/NG assay (cobas) for CT and NG in high-risk MSM attending an inner city sexual health clinic.ResultsWe found testing of pooled pharyngeal, rectal and urine samples by the GeneXpert to have 100% agreement for NG and 94% overall agreement for CT when compared with individual specimen testing by cobas. For CT testing, 14 cases were detected for both tests, 4for cobas only, 2 for GeneXpert only and 89 participants were negative for both tests.ConclusionsPooled specimen CT and NG testing by the GeneXpert was accurate when compared with single specimen testing and has potential for screening MSM for CT and NG. The role of pooled specimen testing with the GeneXpert as a point-of-care nucleic acid test in MSM requires further investigation.


2019 ◽  
Vol 26 (11) ◽  
pp. 1946-1959 ◽  
Author(s):  
Le Minh Tu Phan ◽  
Lemma Teshome Tufa ◽  
Hwa-Jung Kim ◽  
Jaebeom Lee ◽  
Tae Jung Park

Background:Tuberculosis (TB), one of the leading causes of death worldwide, is difficult to diagnose based only on signs and symptoms. Methods for TB detection are continuously being researched to design novel effective clinical tools for the diagnosis of TB.Objective:This article reviews the methods to diagnose TB at the latent and active stages and to recognize prospective TB diagnostic methods based on nanomaterials.Methods:The current methods for TB diagnosis were reviewed by evaluating their advantages and disadvantages. Furthermore, the trends in TB detection using nanomaterials were discussed regarding their performance capacity for clinical diagnostic applications.Results:Current methods such as microscopy, culture, and tuberculin skin test are still being employed to diagnose TB, however, a highly sensitive point of care tool without false results is still needed. The utilization of nanomaterials to detect the specific TB biomarkers with high sensitivity and specificity can provide a possible strategy to rapidly diagnose TB. Although it is challenging for nanodiagnostic platforms to be assessed in clinical trials, active TB diagnosis using nanomaterials is highly expected to achieve clinical significance for regular application. In addition, aspects and future directions in developing the high-efficiency tools to diagnose active TB using advanced nanomaterials are expounded.Conclusion:This review suggests that nanomaterials have high potential as rapid, costeffective tools to enhance the diagnostic sensitivity and specificity for the accurate diagnosis, treatment, and prevention of TB. Hence, portable nanobiosensors can be alternative effective tests to be exploited globally after clinical trial execution.


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 363
Author(s):  
Vânia M. Moreira ◽  
Paulo Mascarenhas ◽  
Vanessa Machado ◽  
João Botelho ◽  
José João Mendes ◽  
...  

The rapid and accurate testing of SARS-CoV-2 infection is still crucial to mitigate, and eventually halt, the spread of this disease. Currently, nasopharyngeal swab (NPS) and oropharyngeal swab (OPS) are the recommended standard sampling techniques, yet, these have some limitations such as the complexity of collection. Hence, several other types of specimens that are easier to obtain are being tested as alternatives to nasal/throat swabs in nucleic acid assays for SARS-CoV-2 detection. This study aims to critically appraise and compare the clinical performance of RT-PCR tests using oral saliva, deep-throat saliva/posterior oropharyngeal saliva (DTS/POS), sputum, urine, feces, and tears/conjunctival swab (CS) against standard specimens (NPS, OPS, or a combination of both). In this systematic review and meta-analysis, five databases (PubMed, Scopus, Web of Science, ClinicalTrial.gov and NIPH Clinical Trial) were searched up to the 30th of December, 2020. Case-control and cohort studies on the detection of SARS-CoV-2 were included. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS 2). We identified 1560 entries, 33 of which (1.1%) met all required criteria and were included for the quantitative data analysis. Saliva presented the higher accuracy, 92.1% (95% CI: 70.0–98.3), with an estimated sensitivity of 83.9% (95% CI: 77.4–88.8) and specificity of 96.4% (95% CI: 89.5–98.8). DTS/POS samples had an overall accuracy of 79.7% (95% CI: 43.3–95.3), with an estimated sensitivity of 90.1% (95% CI: 83.3–96.9) and specificity of 63.1% (95% CI: 36.8–89.3). The remaining index specimens could not be adequately assessed given the lack of studies available. Our meta-analysis shows that saliva samples from the oral region provide a high sensitivity and specificity; therefore, these appear to be the best candidates for alternative specimens to NPS/OPS in SARS-CoV-2 detection, with suitable protocols for swab-free sample collection to be determined and validated in the future. The distinction between oral and extra-oral salivary samples will be crucial, since DTS/POS samples may induce a higher rate of false positives. Urine, feces, tears/CS and sputum seem unreliable for diagnosis. Saliva testing may increase testing capacity, ultimately promoting the implementation of truly deployable COVID-19 tests, which could either work at the point-of-care (e.g. hospitals, clinics) or at outbreak control spots (e.g., schools, airports, and nursing homes).


2021 ◽  
Vol 5 ◽  
pp. 239920262110550
Author(s):  
Joško Osredkar ◽  
Katja Krivic ◽  
Teja Fabjan ◽  
Kristina Kumer ◽  
Jure Tršan ◽  
...  

Aim: Although the levels of cardiac troponin I (cTnI) have proved to be a useful diagnostic biomarker of acute myocardial infarction, there are a wide variety of point-of-care (POC) analysers, which provide measurements of cTnI. The aim of this study was to compare the results obtained by the ADVIA Centaur ultra-assay cTnI assay (us-cTnI), ADVIA Centaur high-sensitive cTnI assay (hs-cTnI) and a POC high-sensitivity assay using PATHFAST. We also aimed to explore total turnaround time (TAT) for laboratory results using the POC PATHFAST analyser. Methods: Samples from 161 patients were taken. Of these samples, 129 were tested with all three assays (us-cTnI, hs-cTnI and PATHFAST), and 32 samples were tested on PATHFAST for the comparison of whole blood, serum and plasma. Results: Comparison of the POC testing methods in this study demonstrated that there are strong linear relationships between all three cTnI assays (us-cTnI, hs-cTnI and POC on PATHFAST). Furthermore, we also show there are strong linear relationships between the two high-sensitive cTnI assays (hs-cTnI and PATHFAST) for blood serum samples, as determined by Passing–Bablok regression analyses. In our comparison of our new data with our older study, the TAT went down. Conclusion: The timeliness of laboratory results is, in addition to accuracy and precision, one of the key indicators of laboratory performance, and at the same time has a significant impact on the course of the patient’s condition. It is therefore important that the laboratory strives to meet the expectations of clinicians regarding the time from the order to the result of the analysis.