scholarly journals Telestroke Assessment With Perfusion CT Improves the Diagnostic Accuracy of Stroke vs. Mimic

2021 ◽  
Vol 12 ◽  
Author(s):  
Lucinda Tran ◽  
Longting Lin ◽  
Neil Spratt ◽  
Andrew Bivard ◽  
Beng Lim Alvin Chew ◽  
...  

Background and Purpose: CT perfusion (CTP) has been implemented widely in regional areas of Australia for telestroke assessment. The aim of this study was to determine if, as part of telestroke assessment, CTP provided added benefit to clinical features in distinguishing between strokes and mimic and between transient ischaemic attack (TIA) and mimic.Methods: We retrospectively analysed 1,513 consecutively recruited patients referred to the Northern New South Wales Telestroke service, where CTP is performed as a part of telestroke assessment. Patients were classified based on the final diagnosis of stroke, TIA, or mimic. Multivariate regression models were used to determine factors that could be used to differentiate between stroke and mimic and between TIA and mimic.Results: There were 693 strokes, 97 TIA, and 259 mimics included in the multivariate regression models. For the stroke vs. mimic model using symptoms only, the area under the curve (AUC) on the receiver operator curve (ROC) was 0.71 (95% CI 0.67–0.75). For the stroke vs. mimic model using the absence of ischaemic lesion on CTP in addition to clinical features, the AUC was 0.90 (95% CI 0.88–0.92). The multivariate regression model for predicting mimic from TIA using symptoms produced an AUC of 0.71 (95% CI 0.65–0.76). The addition of absence of an ischaemic lesion on CTP to clinical features for the TIA vs. mimic model had an AUC of 0.78 (95% CI 0.73–0.83)Conclusions: In the telehealth setting, the absence of an ischaemic lesion on CTP adds to the diagnostic accuracy in distinguishing mimic from stroke, above that from clinical features.

Nutrients ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 640
Author(s):  
Carlo Caffarelli ◽  
Carla Mastrorilli ◽  
Angelica Santoro ◽  
Massimo Criscione ◽  
Michela Procaccianti

Hazelnuts commonly elicit allergic reactions starting from childhood and adolescence, with a rare resolution over time. The definite diagnosis of a hazelnut allergy relies on an oral food challenge. The role of component resolved diagnostics in reducing the need for oral food challenges in the diagnosis of hazelnut allergies is still debated. Therefore, three electronic databases were systematically searched for studies on the diagnostic accuracy of specific-IgE (sIgE) on hazelnut proteins for identifying children with a hazelnut allergy. Studies regarding IgE testing on at least one hazelnut allergen component in children whose final diagnosis was determined by oral food challenges or a suggestive history of serious symptoms due to a hazelnut allergy were included. Study quality was assessed by the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Eight studies enrolling 757 children, were identified. Overall, sensitivity, specificity, area under the curve and diagnostic odd ratio of Cor a 1 sIgE were lower than those of Cor a 9 and Cor a 14 sIge. When the test results were positive, the post-test probability of a hazelnut allergy was 34% for Cor a 1 sIgE, 60% for Cor a9 sIgE and 73% for Cor a 14 sIgE. When the test results were negative, the post-test probability of a hazelnut allergy was 55% for Cor a 1 sIgE, 16% for Cor a9 sIgE and 14% for Cor a 14 sIgE. Measurement of IgE levels to Cor a 9 and Cor a 14 might have the potential to improve specificity in detecting clinically tolerant children among hazelnut-sensitized ones, reducing the need to perform oral food challenges.


2018 ◽  
Vol 64 (3) ◽  
pp. 515-525 ◽  
Author(s):  
Patrick Badertscher ◽  
Jasper Boeddinghaus ◽  
Thomas Nestelberger ◽  
Raphael Twerenbold ◽  
Karin Wildi ◽  
...  

Abstract BACKGROUND There is concern that high-sensitivity cardiac troponin (hs-cTn) may have low diagnostic accuracy in patients with low acute coronary syndrome (ACS) probability. METHODS We prospectively stratified patients presenting with acute chest discomfort to the emergency department (ED) into 3 groups according to their probability for ACS as assessed by the treating ED physician using a visual analog scale: ≤10%, 11% to 79%, and ≥80%, reviewing all information available at 90 min. hs-cTnT and hs-cTnI concentrations were determined in a blinded fashion. Two independent cardiologists adjudicated the final diagnosis. RESULTS Among 3828 patients eligible for analysis, 1189 patients had low (≤10%) probability for ACS. The incidence of non-ST-segment elevation myocardial infarction (NSTEMI) increased from 1.3% to 12.2% and 54.8% in patients with low, intermediate, and high ACS probability, respectively. The positive predictive value of hs-cTnT and hs-cTnI was low in patients with low ACS probability and increased with the incidence of NSTEMI, whereas the diagnostic accuracy of hs-cTnT and hs-cTnI for NSTEMI as quantified by the area under the curve (AUC) was very high and comparable among all 3 strata, e.g., AUC hs-cTnI, 0.96 (95% CI, 0.94–0.97); 0.87 (95% CI, 0.85–0.89); and 0.89 (95% CI, 0.87–0.92), respectively. Findings were validated using bootstrap analysis as an alternative methodology to define ACS probability. Similarly, higher hs-cTnT/I concentrations independently predicted all-cause mortality within 2 years (e.g., hs-cTnT hazard ratio, 1.39; 95% CI, 1.27–1.52), irrespective of ACS probability. CONCLUSIONS Diagnostic and prognostic accuracy and utility of hs-cTnT and hs-cTnI remain high in patients with acute chest discomfort and low ACS probability. ClinicalTrials.gov Identifier: NCT00470587.


VASA ◽  
2019 ◽  
Vol 48 (6) ◽  
pp. 516-522 ◽  
Author(s):  
Verena Mayr ◽  
Mirko Hirschl ◽  
Peter Klein-Weigel ◽  
Luka Girardi ◽  
Michael Kundi

Summary. Background: For diagnosis of peripheral arterial occlusive disease (PAD), a Doppler-based ankle-brachial-index (dABI) is recommended as the first non-invasive measurement. Due to limitations of dABI, oscillometry might be used as an alternative. The aim of our study was to investigate whether a semi-automatic, four-point oscillometric device provides comparable diagnostic accuracy. Furthermore, time requirements and patient preferences were evaluated. Patients and methods: 286 patients were recruited for the study; 140 without and 146 with PAD. The Doppler-based (dABI) and oscillometric (oABI and pulse wave index – PWI) measurements were performed on the same day in a randomized cross-over design. Specificity and sensitivity against verified PAD diagnosis were computed and compared by McNemar tests. ROC analyses were performed and areas under the curve were compared by non-parametric methods. Results: oABI had significantly lower sensitivity (65.8%, 95% CI: 59.2%–71.9%) compared to dABI (87.3%, CI: 81.9–91.3%) but significantly higher specificity (79.7%, 74.7–83.9% vs. 67.0%, 61.3–72.2%). PWI had a comparable sensitivity to dABI. The combination of oABI and PWI had the highest sensitivity (88.8%, 85.7–91.4%). ROC analysis revealed that PWI had the largest area under the curve, but no significant differences between oABI and dABI were observed. Time requirement for oABI was significantly shorter by about 5 min and significantly more patients would prefer oABI for future testing. Conclusions: Semi-automatic oABI measurements using the AngER-device provide comparable diagnostic results to the conventional Doppler method while PWI performed best. The time saved by oscillometry could be important, especially in high volume centers and epidemiologic studies.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yoshikazu Nagase ◽  
Shinya Matsuzaki ◽  
Masayuki Endo ◽  
Takeya Hara ◽  
Aiko Okada ◽  
...  

Abstract Background A diagnostic sign on magnetic resonance imaging, suggestive of posterior extrauterine adhesion (PEUA), was identified in patients with placenta previa. However, the clinical features or surgical outcomes of patients with placenta previa and PEUA are unclear. Our study aimed to investigate the clinical characteristics of placenta previa with PEUA and determine whether an altered management strategy improved surgical outcomes. Methods This single institution retrospective study examined patients with placenta previa who underwent cesarean delivery between 2014 and 2019. In June 2017, we recognized that PEUA was associated with increased intraoperative bleeding; thus, we altered the management of patients with placenta previa and PEUA. To assess the relationship between changes in practice and surgical outcomes, a quasi-experimental method was used to examine the difference-in-difference before (pre group) and after (post group) the changes. Surgical management was modified as follows: (i) minimization of uterine exteriorization and adhesion detachment during cesarean delivery and (ii) use of Nelaton catheters for guiding cervical passage during Bakri balloon insertion. To account for patient characteristics, propensity score matching and multivariate regression analyses were performed. Results The study cohort (n = 141) comprised of 24 patients with placenta previa and PEUA (PEUA group) and 117 non-PEUA patients (control group). The PEUA patients were further categorized into the pre (n = 12) and post groups (n = 12) based on the changes in surgical management. Total placenta previa and posterior placentas were more likely in the PEUA group than in the control group (66.7% versus 42.7% [P = 0.04] and 95.8% versus 63.2% [P < 0.01], respectively). After propensity score matching (n = 72), intraoperative blood loss was significantly higher in the PEUA group (n = 24) than in the control group (n = 48) (1515 mL versus 870 mL, P < 0.01). Multivariate regression analysis revealed that PEUA was a significant risk factor for intraoperative bleeding before changes were implemented in practice (t = 2.46, P = 0.02). Intraoperative blood loss in the post group was successfully reduced, as opposed to in the pre group (1180 mL versus 1827 mL, P = 0.04). Conclusions PEUA was associated with total placenta previa, posterior placenta, and increased intraoperative bleeding in patients with placenta previa. Our altered management could reduce the intraoperative blood loss.


2021 ◽  
Vol 49 (2) ◽  
pp. 030006052098268
Author(s):  
Mingli Yuan ◽  
Yafei Wang ◽  
Wen Yin ◽  
Yang Xiao ◽  
Manman Hu ◽  
...  

Objective To evaluate the efficacy of rapid on-site cytological evaluation (ROSE) in determining specimen adequacy and diagnostic accuracy in the interventional diagnosis of lung lesions. Methods This retrospective study included 127 consecutive cases of lung lesions, which were sampled by bronchoscopy or transthoracic fine needle aspiration, and diagnosed on ROSE followed by histopathology. ROSE was performed by a trained pulmonologist and the diagnosis of ROSE was compared with the final diagnosis. Results The sensitivity of ROSE in determining adequacy of specimens was 97.5% and specificity in determining inadequacy was 85.7%. The diagnostic efficacy of ROSE for assessing malignancy (sensitivity of 94.5% and specificity of 100%) and non-malignancy (sensitivity of 97.8% and specificity of 100%) was excellent. The sensitivity of ROSE for diagnosing small cell carcinoma (100%) was highest, followed by adenocarcinoma (89.2%) and squamous cell carcinoma (75.0%). Performance of ROSE by a trained pulmonologist also determined tuberculosis with a high diagnostic sensitivity (83.3%) and specificity (100%). Conclusions A trained pulmonologist can reliably carry out ROSE to ensure the adequacy of the sample, distinguish between malignancy and non-malignancy, and make a preliminary diagnosis in a large number of cases.


2021 ◽  
pp. injuryprev-2020-044092
Author(s):  
Éric Tellier ◽  
Bruno Simonnet ◽  
Cédric Gil-Jardiné ◽  
Marion Lerouge-Bailhache ◽  
Bruno Castelle ◽  
...  

ObjectiveTo predict the coast-wide risk of drowning along the surf beaches of Gironde, southwestern France.MethodsData on rescues and drownings were collected from the Medical Emergency Center of Gironde (SAMU 33). Seasonality, holidays, weekends, weather and metocean conditions were considered potentially predictive. Logistic regression models were fitted with data from 2011 to 2013 and used to predict 2015–2017 events employing weather and ocean forecasts.ResultsAir temperature, wave parameters, seasonality and holidays were associated with drownings. Prospective validation was performed on 617 days, covering 232 events (rescues and drownings) reported on 104 different days. The area under the curve (AUC) of the daily risk prediction model (combined with 3-day forecasts) was 0.82 (95% CI 0.79 to 0.86). The AUC of the 3-hour step model was 0.85 (95% CI 0.81 to 0.88).ConclusionsDrowning events along the Gironde surf coast can be anticipated up to 3 days in advance. Preventative messages and rescue preparations could be increased as the forecast risk increased, especially during the off-peak season, when the number of available rescuers is low.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Boris Lovrić ◽  
Siniša Šijanović ◽  
Joško Lešin ◽  
Josip Juras

Abstract Objectives Women with gestational diabetes (GDM) and weight gain during pregnancy above recommended more often give birth to macrosomic children. The goal of this study was to evaluate the diagnostic accuracy of the modified formula for ultrasound assessment of fetal weight created in a pilot study using a similar specimen in comparison to the Hadlock-2 formula. Methods This is a prospective, cohort, applicative, observational, quantitative, and analytical study, which included 213 pregnant women with a singleton pregnancy, GDM, and pregnancy weight gain above recommended. Participants were consecutively followed in the time period between July 1st, 2016, and August 31st, 2020. Ultrasound estimations were made within three days before the delivery. Fetal weights estimated using both formulas were compared to the newborns’ weights. Results A total of 133 fetal weight estimations were made. In comparison to the newborns’ weight modified formula had significantly smaller deviation in weight estimation compared to the Hadlock-2 formula, higher frequency of deviation within 5% of newborns weights (78.2% [95% CI=0.74–0.83] vs. 60.2%), smaller frequency of deviations from 5 to 10% (19.5 vs. 33.8%) and above 10%, which was even more significant among macrosomic children. There were 36/50 (72%) correctly diagnosed cases of macrosomia by modified and 33/50 (66%) by Hadlock-2 formula. Area under the curve (AUC) for the modified formula was 0.854 (95% CI=0.776–0.932), and for the Hadlock-2 formula 0.824 (95% CI=0.740–0.908). The positive predictive value of the modified formula was 81.81%, the negative 97.91%. Conclusions In cases of greater fetal weights, the modified formula showed greater precision.


Cardiology ◽  
2020 ◽  
pp. 1-8
Author(s):  
Ronny Alcalai ◽  
Boris Varshisky ◽  
Ahmad Marhig ◽  
David Leibowitz ◽  
Larissa Kogan-Boguslavsky ◽  
...  

<b><i>Background:</i></b> Early and accurate diagnosis of acute coronary syndrome (ACS) is essential for initiating lifesaving interventions. In this article, the diagnostic performance of a novel point-of-care rapid assay (SensAheart<sup>©</sup>) is analyzed. This assay qualitatively determines the presence of 2 cardiac biomarkers troponin I and heart-type fatty acid-binding protein that are present soon after onset of myocardial injury. <b><i>Methods:</i></b> We conducted a prospective observational study of consecutive patients who presented to the emergency department with typical chest pain. Simultaneous high-sensitive cardiac troponin T (hs-cTnT) and SensAheart testing was performed upon hospital admission. Diagnostic accuracy was computed using SensAheart or hs-cTnT levels versus the final diagnosis defined as positive/negative. <b><i>Results:</i></b> Of 225 patients analyzed, a final diagnosis of ACS was established in 138 patients, 87 individuals diagnosed with nonischemic chest pain. In the overall population, as compared to hs-cTnT, the sensitivity of the initial SensAheart assay was significantly higher (80.4 vs. 63.8%, <i>p</i> = 0.002) whereas specificity was lower (78.6 vs. 95.4%, <i>p</i> = 0.036). The overall diagnostic accuracy of SensAheart assay was similar to the hs-cTnT (82.7% compared to 76.0%, <i>p</i> = 0.08). <b><i>Conclusions:</i></b> Upon first medical contact, the novel point-of-care rapid SensAheart assay shows a diagnostic performance similar to hs-cTnT. The combination of 2 cardiac biomarkers in the same kit allows for very early detection of myocardial damage. The SensAheart assay is a reliable and practical tool for ruling-in the diagnosis of ACS.


2019 ◽  
pp. jramc-2018-001132
Author(s):  
Pierre Perrier ◽  
J Leyral ◽  
O Thabouillot ◽  
D Papeix ◽  
G Comat ◽  
...  

IntroductionTo evaluate the usefulness of point-of-care ultrasound (POCUS) performed by young military medicine residents after short training in the diagnosis of medical emergencies.MethodsA prospective study was performed in the emergency department of a French army teaching hospital. Two young military medicine residents received ultrasound training focused on gall bladder, kidneys and lower limb veins. After clinical examination, they assigned a ‘clinicaldiagnostic probability’ (CP) on a visual analogue scale from 0 (definitely not diagnosis) to 10 (definitive diagnosis). The same student performed ultrasound examination and assigned an ‘ultrasounddiagnostic probability’ (UP) in the same way. The absolute difference between CP and UP was calculated. This result corresponded to the Ultrasound Diagnostic Index (UDI), which was positive if UP was closer to the final diagnosis than CP (POCUS improved the diagnostic accuracy), and negative conversely (POCUS decreased the diagnostic accuracy).ResultsForty-eight patients were included and 48 ultrasound examinations were performed. The present pathologies were found in 14 patients (29%). The mean UDI value was +3 (0–5). UDI was positive in 35 exams (73%), zero in 12 exams (25%) and negative in only one exam (2%).ConclusionPOCUS performed after clinical examination increases the diagnostic accuracy of young military medicine residents.


Sign in / Sign up

Export Citation Format

Share Document