scholarly journals Shining a Light on Race: Contrast and Assimilation Effects in the Perception of Skin Tone and Racial Typicality

2020 ◽  
Vol 11 ◽  
Author(s):  
Kevin R. Brooks ◽  
Daniel Sturman ◽  
O. Scott Gwinn

Researchers have long debated the extent to which an individual’s skin tone influences their perceived race. Brooks and Gwinn (2010) demonstrated that the race of surrounding faces can affect the perceived skin tone of a central target face without changing perceived racial typicality, suggesting that skin lightness makes a small contribution to judgments of race compared to morphological cues (the configuration and shape of the facial features). However, the lack of a consistent light source may have undermined the reliability of skin tone cues, encouraging observers to rely disproportionately on morphological cues instead. The current study addresses this concern by using 3D models of male faces with typically Black African or White European appearances that are illuminated by the same light source. Observers perceived target faces surrounded by White faces to have darker skin than those surrounded by Black faces, particularly for faces of intermediate lightness. However, when asked to judge racial typicality, a small assimilation effect was evident, with target faces perceived as more stereotypically White when surrounded by White than when surrounded by Black faces at intermediate levels of typicality. This evidence of assimilation effects for perceived racial typicality despite concurrent contrast effects on perceived skin lightness supports the previous conclusion that perceived skin lightness has little influence on judgments of racial typicality for racially ambiguous faces, even when lighting is consistent.

2020 ◽  
Vol 2020 (1) ◽  
pp. 5-9
Author(s):  
Ruili He ◽  
Kaida Xiao ◽  
Michael Pointer ◽  
Stephen Westland

In this paper, skin tone heterogeneity in five facial areas (forehead, right cheekbone, left cheekbone, nose tip and chin) was investigated under six light sources with correlated color temperature (CCT) of 2850 K, 3500 K, 5000 K, 5500 K, 6500 K and 9000 K. Firstly, a facial image capturing protocol was developed and applied to five female participants, and their facial skin tone was analyzed based on the captured images. Through color characterization of the camera, XYZ values in each facial area were converted by a matrix from the extracted RGB data and then transformed to CAM02-UCS color space. MCDM with CAM02-UCS color difference was used to quantify skin tone heterogeneity in each facial area. The results under different light sources indicated that larger heterogeneity exists under the light source with lower CCT, and when the CCT of the light source ranges from 5000 K to 9000 K, there was smaller skin tone heterogeneity in each facial area.


2017 ◽  
Vol 23 (12) ◽  
pp. 12734-12737
Author(s):  
Sungjun Han ◽  
Yongbae Kim ◽  
Jongweon Kim

Author(s):  
Mitsuo Ohtsuki ◽  
Michael Sogard

Structural investigations of biological macromolecules commonly employ CTEM with negative staining techniques. Difficulties in valid image interpretation arise, however, due to problems such as variability in thickness and degree of penetration of the staining agent, noise from the supporting film, and artifacts from defocus phase contrast effects. In order to determine the effects of these variables on biological structure, as seen by the electron microscope, negative stained macromolecules of high density lipoprotein-3 (HDL3) from human serum were analyzed with both CTEM and STEM, and results were then compared with CTEM micrographs of freeze-etched HDL3. In addition, we altered the structure of this molecule by digesting away its phospholipid component with phospholipase A2 and look for consistent changes in structure.


Author(s):  
S. Golladay

The theory of multiple scattering has been worked out by Groves and comparisons have been made between predicted and observed signals for thick specimens observed in a STEM under conditions where phase contrast effects are unimportant. Independent measurements of the collection efficiencies of the two STEM detectors, calculations of the ratio σe/σi = R, where σe, σi are the total cross sections for elastic and inelastic scattering respectively, and a model of the unknown mass distribution are needed for these comparisons. In this paper an extension of this work will be described which allows the determination of the required efficiencies, R, and the unknown mass distribution from the data without additional measurements or models. Essential to the analysis is the fact that in a STEM two or more signal measurements can be made simultaneously at each image point.


Author(s):  
J. M. Cowley

The comparison of scanning transmission electron microscopy (STEM) with conventional transmission electron microscopy (CTEM) can best be made by means of the Reciprocity Theorem of wave optics. In Fig. 1 the intensity measured at a point A’ in the CTEM image due to emission from a point B’ in the electron source is equated to the intensity at a point of the detector, B, due to emission from a point A In the source In the STEM. On this basis it can be demonstrated that contrast effects In the two types of instrument will be similar. The reciprocity relationship can be carried further to include the Instrument design and experimental procedures required to obtain particular types of information. For any. mode of operation providing particular information with one type of microscope, the analagous type of operation giving the same information can be postulated for the other type of microscope. Then the choice between the two types of instrument depends on the practical convenience for obtaining the required Information.


Author(s):  
R. J. Horylev ◽  
L. E. Murr

Smith has shown by dark-field electron microscopy of extracted ThO2 particles from TD-nickel (2% ThO2) that they possess single crystal characteristics. It is generally assumed that these particle dispersions are incoherent. However, some diffraction effects associated with the particle images appeared to be similar to coherency strain fields. The present work will demonstrate conclusively that ThO2 dispersed particles in TD-nickel (2% ThO2) and TD-NiCr (2% ThO2, 20% Cr, Ni) are single crystals. Moreover, the diffraction contrast effects are extinction fringes. That is, these effects arise because of the particle orientation with respect to the electron beam and the extinction conditions for various operating reflections The particles are in fact incoherent.


Author(s):  
Michael T. Bucek ◽  
Howard J. Arnott

It is believed by the authors, with supporting experimental evidence, that as little as 0.5°, or less, knife clearance angle may be a critical factor in obtaining optimum quality ultrathin sections. The degree increments located on the knife holder provides the investigator with only a crude approximation of the angle at which the holder is set. With the increments displayed on the holder one cannot set the clearance angle precisely and reproducibly. The ability to routinely set this angle precisely and without difficulty would obviously be of great assistance to the operator. A device has been contrived to aid the investigator in precisely setting the clearance angle. This device is relatively simple and is easily constructed. It consists of a light source and an optically flat, front surfaced mirror with a minute black spot in the center. The mirror is affixed to the knife by placing it permanently on top of the knife holder.


Author(s):  
P.M. Houpt ◽  
A. Draaijer

In confocal microscopy, the object is scanned by the coinciding focal points (confocal) of a point light source and a point detector both focused on a certain plane in the object. Only light coming from the focal point is detected and, even more important, out-of-focus light is rejected.This makes it possible to slice up optically the ‘volume of interest’ in the object by moving it axially while scanning the focused point light source (X-Y) laterally. The successive confocal sections can be stored in a computer and used to reconstruct the object in a 3D image display.The instrument described is able to scan the object laterally with an Ar ion laser (488 nm) at video rates. The image of one confocal section of an object can be displayed within 40 milliseconds (1000 х 1000 pixels). The time to record the total information within the ‘volume of interest’ normally depends on the number of slices needed to cover it, but rarely exceeds a few seconds.


Author(s):  
H. Banzhof ◽  
I. Daberkow

A Philips EM 420 electron microscope equipped with a field emission gun and an external STEM unit was used to compare images of single crystal surfaces taken by conventional reflection electron microscopy (REM) and scanning reflection electron microscopy (SREM). In addition an angle-resolving detector system developed by Daberkow and Herrmann was used to record SREM images with the detector shape adjusted to different details of the convergent beam reflection high energy electron diffraction (CBRHEED) pattern.Platinum single crystal spheres with smooth facets, prepared by melting a thin Pt wire in an oxyhydrogen flame, served as objects. Fig. 1 gives a conventional REM image of a (111)Pt single crystal surface, while Fig. 2 shows a SREM record of the same area. Both images were taken with the (555) reflection near the azimuth. A comparison shows that the contrast effects of atomic steps are similar for both techniques, although the depth of focus of the SREM image is reduced as a result of the large illuminating aperture. But differences are observed at the lengthened images of small depressions and protrusions formed by atomic steps, which give a symmetrical contrast profile in the REM image, while an asymmetric black-white contrast is observed in the SREM micrograph. Furthermore the irregular structures which may be seen in the middle of Fig. 2 are not visible in the REM image, although it was taken after the SREM record.


2018 ◽  
Vol 32 (4) ◽  
pp. 182-190 ◽  
Author(s):  
Kenta Matsumura ◽  
Koichi Shimizu ◽  
Peter Rolfe ◽  
Masanori Kakimoto ◽  
Takehiro Yamakoshi

Abstract. Pulse volume (PV) and its related measures, such as modified normalized pulse volume (mNPV), direct-current component (DC), and pulse rate (PR), derived from the finger-photoplethysmogram (FPPG), are useful psychophysiological measures. Although considerable uncertainties exist in finger-photoplethysmography, little is known about the extent of the adverse effects on the measures. In this study, we therefore examined the inter-method reliability of each index across sensor positions and light intensities, which are major disturbance factors of FPPG. From the tips of the index fingers of 12 participants in a resting state, three simultaneous FPPGs having overlapping optical paths were recorded, with their light intensity being changed in three steps. The analysis revealed that the minimum values of three coefficients of Cronbach’s α for ln PV, ln mNPV, ln DC, and PR across positions were .948, .850, .922, and 1.000, respectively, and that those across intensities were .774, .985, .485, and .998, respectively. These findings suggest that ln mNPV and PR can be used for psychophysiological studies irrespective of minor differences in sensor attachment positions and light source intensity, whereas and ln DC can also be used for such studies but under the condition of light intensity being fixed.


Sign in / Sign up

Export Citation Format

Share Document