scholarly journals Effect of Adhesive Application Method on the Enamel Bond Durability of a Two-Step Adhesive System Utilizing a Universal Adhesive-Derived Primer

2021 ◽  
Vol 11 (16) ◽  
pp. 7675
Author(s):  
Toshiki Takamizawa ◽  
Munenori Yokoyama ◽  
Keiichi Sai ◽  
Sho Shibasaki ◽  
Wayne W. Barkmeier ◽  
...  

This study aimed to evaluate the effect of the adhesive application method on the durability of the enamel bond and the thickness of the adhesive layer. A new-generation two-step universal adhesive system, G2-Bond Universal, and two conventional two-step adhesive systems were utilized. The shear bond strength to bovine enamel was measured after thermal cycling in both etch-and-rinse and self-etch modes. Fifteen specimens were divided into three groups as follows: Group I, wherein a strong air stream was applied over the bonding agent for 5 s; Group II, wherein a gentle air stream was applied over the bonding agent for 5 s; and Group III, which was prepared as in Group II, followed by the application of a second layer of the bonding agent and a gentle air stream for 5 s. The durability of the enamel bond and thickness of the tested adhesives were influenced by the application method in both etching modes. The application method used in Group II appeared to be most suitable in terms of the bonding of the adhesives to the enamel. The new-generation two-step self-etch adhesive, comprising a universal adhesive-derived primer and a hydrophobic bonding agent, showed superior bond performance to the conventional two-step adhesive systems.

2021 ◽  
Vol 2 ◽  
Author(s):  
Takaaki Sato ◽  
Tomohiro Takagaki ◽  
Takashi Hatayama ◽  
Toru Nikaido ◽  
Junji Tagami

Optimal strategies for the application of an adhesive differ between enamel and dentin because of the differences in their composition. The development of adhesive systems has mainly focused on the bonding of dentin, rather than on the enamel, by etching with phosphoric acid (PA). Dental adhesive technologies continue to rapidly advance, and various adhesive systems have been developed since the study of Buonocore in 1955. He introduced the enamel acid-etch technique. Then, the etch-and-rinse (ER) system was developed, and subsequently, the self-etch (SE) system. Universal adhesives are a new generation of one-bottle SE adhesives that can be applied with either ER mode or SE mode, or a combined system involving selective enamel etching mode. Since the combination of PA etching and the SE system differs from conventional ER systems, the enamel bonding strategy should be carefully considered. This concise review of the literature on reliable enamel bonding strategies should prove helpful to clinicians to choose an appropriate adhesive system to achieve optimal clinical outcomes.


2017 ◽  
Vol 41 (3) ◽  
pp. 214-218 ◽  
Author(s):  
Tathiane Larissa Lenzi ◽  
Fabio Zovico Maxnuck Soares ◽  
Rachel de Oliveira Rocha

Objective: To evaluate the effect of bonding strategy on microtensile bond strength (μTBS) of a new universal adhesive system to primary tooth dentin. Study design: Flat dentin surfaces from 25 primary molars were assigned to 5 groups according to the adhesive and bonding approach: Adper Single Bond 2 (two-step etch-and-rinse adhesive) and Clearfil SE Bond (two-step self-etch system), as controls; Scotchbond Universal Adhesive–self-etch, dry or wet-bonding etch-and-rinse strategies. Composite buildups were constructed and the teeth were sectioned to obtain bonded sticks (0.8 mm2) to be tested under tension at 1mm/min. The μTBS means were analyzed by one-way ANOVA and Tukey's tests (α = 0.05). Failure mode was evaluated using a stereomicroscope (400×). Results: Universal adhesive applied following both dry and wet-bonding etch-and-rinse strategies showed similar bond strength compared with control adhesive systems. Self-etch approach resulted in the lowest μTBS values. For all groups, adhesive/mixed failure prevailed. The percentage of premature debonded specimens was higher when the universal adhesive was used as self-etch mode. Conclusion: The universal adhesive does not share the same versatility of being used in the etch-and-rinse and self-etch approaches; however, the use of the new adhesive following either wet or dry-bonding may be a suitable option as alternative to two-step etch-and-rinse adhesive protocol.


Scanning ◽  
2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
Yasmine Mendes Pupo ◽  
Cintia Fernanda de Freitas Bernardo ◽  
Francielly Fernanda de Freitas A. de Souza ◽  
Milton Domingos Michél ◽  
Camila Nunes de Morais Ribeiro ◽  
...  

The aim of this study was to evaluate in fibroblast cultures the direct cytotoxic effects of etch-and-rinse, self-etch, and universal adhesive systems. The sterile glass cover slips (n=3) were then immersed in culture medium to obtain the eluates for the experimental groups: (1) Adper™ Single Bond 2; (2) Ambar; (3) Adper™ Scotchbond™ Multi-Purpose; (4) Scotchbond™ Universal; (5) Ambar Universal; and (6) OptiBond All-In-One. As a negative control, sterile glass cover slips were immersed in culture medium only. After 24 h, the eluate obtained was applied on fibroblast culture. Cell viability and cell morphology were evaluated by MTT assay and SEM, respectively. Data were analyzed by Kruskal–Wallis and Mann–Whitney tests (α=0.05). All adhesive systems except universal reduced cell viability in 3T3 cells to between 26.04% and 56.57%, and Scotchbond Universal and Ambar Universal reduced cell viability to 2.13% and 3.57%, respectively, when compared to the negative control. Cytoplasmic membrane shrinkage and cell-free areas with residual membrane fragments from dead cells were observed. In conclusion, improvements in universal adhesive system formulations and their mechanisms of action are not accompanied by increased toxicity compared with those in other systems, warranting commitment to the use of these dentin-pulp complexes.


2019 ◽  
Vol 44 (5) ◽  
pp. 510-520 ◽  
Author(s):  
V Hass ◽  
AFM Cardenas ◽  
FSF Siqueira ◽  
RR Pacheco ◽  
PMW Zago ◽  
...  

SUMMARY Objective: This study investigated the bonding performance of three universal adhesive systems applied using etch-and-rinse (ER) or self-etch (SE) strategies on natural dentin caries. Materials and Methods: Sixty human third molars were selected for this study: 30 naturally carious (CAD) and 30 sound (SD) teeth. The dentin surfaces were exposed, and teeth were randomly assigned to each evaluated adhesive system: Scotchbond Universal (SBU), Futurabond U (FBU), and Prime&Bond Elect (PBE) and an adhesive strategy: ER or SE. The adhesive systems were applied following the manufacturer's instructions, and the teeth were restored using a resin composite (Filtek Supreme Ultra, 3M). After 24 hours (distilled water at 37°C), samples were sectioned and evaluated using microtensile bond strength analysis (μTBS), micro-Raman spectroscopy to evaluate the degree of conversion within the hybrid layer (DC), and scanning electronic microscopy (SEM) to describe the morphology of the hybrid layer. The μTBS and DC data were analyzed using three-way analysis of variance and Tukey's test for means comparison (α=0.05). The SEM images were analyzed qualitatively. Results: Reduced μTBS values were observed when comparing CAD with SD, regardless of adhesive system or strategy (p<0.0001). SBU showed statistically higher μTBS for both dentin substrates and strategies (p<0.0001). Furthermore, SBU showed greater integrity of the hybrid layer and resin tag formation compared with FBU and PBE. Mean μTBS values for FBU were higher for SD in the SE mode, whereas higher mean μTBS values were observed for CAD in the ER mode, both compared with PBE (p<0.001). Conclusion: Bonding performance is reduced on a caries-affected substrate. The ER strategy was not able to improve the bonding performance on natural CAD for universal adhesive systems. Improved bonding performance was obtained when using the Scotchbond Universal system.


2011 ◽  
Vol 493-494 ◽  
pp. 643-648
Author(s):  
Bilge Tarcin ◽  
Gulden Sinmazisik ◽  
Fusun Ozer ◽  
Turgut Gülmez

The purpose of this study was to evaluate the effect of different surface treatments and adhesive systems on bond strength of composite resin to porcelain when there is need to repair the restoration.Materials and methods: Rectangular discs (10mm x 12mm) with a height of 2mm were prepared from leucite-reinforced feldspathic ceramic CAD/CAM blocks (Vitablocs), embedded in acrylic resin, and bur cut porcelain surfaces were created. The specimens were divided into three groups (n=20) according to the surface treatments: Er:YAG laser at 2W for 20 seconds, air abrasion with 50µm Al2O3 at 2.5 bar for 15 seconds, and the last group left untreated as control. After silane (Monobond S) application on ten specimens from each group, composite rods (Aelite Flo LV) with 4.25mm diameter and 4mm height were bonded to ceramic surfaces with a self-etch adhesive system (All-Bond SE). The remaining ten specimens from each group were etched with 36% orthophosphoric acid (Blue Etch Dental Etching Gel), and after silane and bonding agent (One-Step Plus) application composite rods with the mentioned dimensions were bonded. All groups were stored in distilled water at 37°C for one day before mechanical testing. Shear testing of all groups were performed on a universal testing machine with a load cell of 50kg and at a crosshead speed of 1.5mm/min. Results were statistically analyzed using Mann Whitney U and Kruskall Wallis tests.Results: The bond strength values of the self-etch adhesive system in the lased and control groups were statistically higher in comparison to the other adhesive system (p<0.01, p<0.05, respectively). The highest bond strength values were obtained in the Er:YAG lased and self-etch adhesive applied group.Conclusions: When there is need to repair of a porcelain restoration, a self-etch adhesive application after Er:YAG laser treatment could be the method of choice.


2016 ◽  
Vol 17 (10) ◽  
pp. 820-825 ◽  
Author(s):  
Mateus R Tonetto ◽  
Ana CS Diniz ◽  
Larissa M Pinheiro ◽  
Lauber J dos Santosh Almeida ◽  
Carlos RG Torres ◽  
...  

ABSTRACT Introduction The adhesive systems and the techniques currently used are designed to provide a more effective adhesion with reduction of the protocol application. The objective of this study was to evaluate the bond strength of universal adhesive systems on enamel in different etching modes (self-etch and total etch). Materials and methods The mesial and distal halves of 52 bovine incisors, healthy, freshly extracted, were used and divided into seven experimental groups (n = 13). The enamel was treated in accordance with the following experimental conditions: FUE-Universal System – Futurabond U (VOCO) with etching; FUWE – Futurabond U (VOCO) without etching; SB-Total Etch System – Single Bond 2 (3M); SBUE-Universal System – Single Bond Universal (3M ESPE) with etching; SBUWE – Single Bond Universal (3M ESPE) without etching; CLE-Self-etch System – Clearfil SE Bond (Kuraray) was applied with etching; CLWE – Clearfil SE Bond (Kuraray) without etching. The specimens were made using the composite spectrum TPH (Dentsply) and stored in distilled water (37 ± 1°C) for 1 month. The microshear test was performed using the universal testing machine EMIC DL 2000 with the crosshead speed of 0.5 mm/minute. The bond strength values were analyzed using statistical tests (Kruskal–Wallis test and Mann–Whitney test) with Bonferroni correction. Results There was no statistically significant difference between groups (p < 0.05), where FUE (36.83 ± 4.9 MPa) showed the highest bond strength values and SBUWE (18.40 ± 2.2 MPa) showed the lowest bond strength values. The analysis of adhesive interface revealed that most failures occurred between the interface composite resin and adhesive. Conclusion The universal adhesive system used in dental enamel varies according to the trademark, and the previous enamel etching for universal systems and the self-etch both induced greater bond strength values. Clinical significance Selective enamel etching prior to the application of a universal adhesive system is a relevant strategy for better performance bonding. How to cite this article Diniz ACS, Bandeca MC, Pinheiro LM, dos Santos Almeida LJr, Torres CRG, Borges AH, Pinto SCS, Tonetto MR, De Jesus Tavarez RR, Firoozmand LM. Influence of Different Etching Modes on Bond Strength to Enamel using Universal Adhesive Systems. J Contemp Dent Pract 2016;17(10):820-825.


2017 ◽  
Vol 42 (3) ◽  
pp. 284-296 ◽  
Author(s):  
EC Martini ◽  
SO Parreiras ◽  
MF Gutierrez ◽  
AD Loguercio ◽  
A Reis

SUMMARY Objectives: The aim of this study was to investigate the effect of different protocols of 17% ethylene diamine tetra-acetic acid (EDTA) conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin. Methods and Materials: Forty bovine teeth with sclerotic dentin and 20 human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, two-minute EDTA conditioning manual application, 30-second EDTA manual application, 30-second EDTA sonic application) and adhesives systems (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bond specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests, respectively. The etching pattern produced on the unground enamel and the sclerotic dentin surfaces under the different protocols and adhesive systems was evaluated under scanning electron microscopy. Results: For enamel, only the main factor adhesive was significant (p&lt;0.0001), with SBU showing the highest μSBS. In sclerotic dentin, the lowest mean was observed for the group without EDTA application and the highest mean in the group with EDTA application with the sonic device for 30 seconds. Regardless of the EDTA protocol, the highest means of μTBS were observed for SBU (p&lt;0.05). Conclusions: EDTA conditioning improves the bonding performance of universal adhesives in the self-etch mode on sclerotic dentin, mainly when applied for 30 seconds with the aid of a sonic device. EDTA pretreatment also improves the retentive etching pattern of enamel, but it does not result in higher enamel bond strength.


2019 ◽  
Vol 10 (4) ◽  
pp. 275-282
Author(s):  
Niusha Golbar ◽  
Shahin Kasraei ◽  
Anahit Afrasiabi ◽  
Elahe Mostajir ◽  
Seyed Masoud Mojahedi

Introduction: Some studies have shown that laser irradiation on unpolymerized adhesives can improve composite-dentin adhesion. The aim of the present study was to evaluate the effect of the diode laser (810 nm) on the microleakage of multi-mode adhesive systems at enamel and dentin margins of composite restorations. Methods: Classic class V boxes were prepared on 48 sound premolar teeth and randomly divided into 6 groups (n=16). In the control groups, Scotchbond Universal (SBC), G-Premio (GBC), and Ambar U (AMC) were used by a self-etch mode. In the test groups (SBL, GBL, ABL), the 810 nm diode laser was irradiated (1 W) for 10 seconds before the polymerization of the adhesive. The boxes were restored by the resin composite. After finishing and polishing, the samples were thermocycled (5°C to 55°C) for 1000 cycles and then immersed in 0.1% methylene blue dye (48 hours). Dye penetration through the gingival and occlusal margins was measured by Stereomicroscope. The data were analyzed at the 5% significance level using Kruskal-Wallis and Mann-Whitney U tests. Results: Significant differences were found between the control and test groups (P<0.05). The occlusal margins of the SBL and GBL groups and the cervical margin of the SBL group exhibited the lowest microleakage (P<0.05). The AM control group showed maximum microleakage at cervical and occlusal margins. Conclusion: The irradiation of the 810 nm diode laser on the unpolymerized universal adhesive systems in a self-etch mode caused a significant reduction in enamel and dentin marginal microleakage of composite restorations.


2014 ◽  
Vol 62 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Ricardo Alves dos SANTOS ◽  
Eliane Alves de LIMA ◽  
Mônica Maria de Albuquerque PONTES ◽  
Alexandre Batista Lopes do NASCIMENTO ◽  
Marcos Antônio Japiassú Resende MONTES ◽  
...  

OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems.


Polymers ◽  
2020 ◽  
Vol 12 (2) ◽  
pp. 461 ◽  
Author(s):  
Joana Vasconcelos e Cruz ◽  
Mário Polido ◽  
José Brito ◽  
Luisa L. Gonçalves

Due to their polymerization characteristics, hyper-branched dendrimers have lately shown to be promising candidates for use in dental materials. In this study, a new dental adhesive system was prepared, using a dendrimer derived from 2-isocyanatoethyl methacrylate (G-IEMA), and its adhesive properties were investigated. The exposed dentin was treated with four universal adhesives (UAs): SBU (Scotchbond Universal™), FUT (Futurabond M+™), AE1 (experimental adhesive with Bis-GMA) and AE2 (experimental adhesive with G-IEMA), using Etch & Rinse (ER) or Self Etch (SE) protocols. Composite build-ups were prepared and stored for 24 h at 37 °C in distilled water. Composite/dentin beams were prepared with cross-sectional areas of 1 ± 0.3 mm2 and µTBS (Micro-tensile bond strength) test was performed at 0.5 mm/min. Failures modes were evaluated by stereomicroscopy, and bonding interfaces were observed by scanning electron microscopy (SEM). Statistical analysis of µTBS data was performed using General Linear (GLM) and Linear Mixed Models (LMM). The effect of adhesive type on µTBS was significant (p = 0.010), with AE1 presenting significantly higher µTBS than SBU (p = 0.019). No other differences between adhesives were observed. ER showed significantly better results than SE (p = 0.019), and no significant interactions between the adhesives and protocols were determined. Results obtained so far pinpoint the emergence of a new paradigm in the dental materials field, as G-IEMA can be used successfully as an alternative to Bis-GMA.


Sign in / Sign up

Export Citation Format

Share Document