Optical chemical sensors can yield distinctively different responses that are dependent on the method applied for readout and evaluation. We therefore present a comprehensive study on the pH determined non-continuously with optical sensors in real milk samples by either photometry or colorimetry (via the RGB-readout of digital images) compared to the pH values obtained electrochemically by potentiometry. Additionally, the photometric determination of pH was conducted with single-wavelength and a dual wavelength ratiometric evaluation of the absorbance. It was found that both the precision and accuracy of the pH determined by photometry benefit from lower concentrations of bromocresol purple, which served as the pH indicator inside the sensor membrane. A further improvement is obtained by the ratiometric evaluation of the photometric sensor response. The pH values obtained from the colorimetric evaluation, however, gain in precision and accuracy if a higher concentration of the indicator is immobilized inside the sensor membrane. This has a major impact on the future fabrication of optical pH sensor membranes because they can be better tuned to match to the most precise and accurate range of the planned detection method.

Proceedings ◽  
2018 ◽  
Vol 3 (1) ◽  
pp. 11 ◽  
Author(s):  
Nedal Y. Abu-Thabit

A polyelectrolyte complex (PEC) membrane based on sulfonated poly (ether ether ketone) and polyaniline (SPEEK-PANI) was developed for pH sensing applications. Aniline was polymerized in the presence of the SPEEK membrane by using in situ chemical oxidative polymerization to yield an ionically crosslinked SPEEK-PANI membrane. The fabricated membrane exhibited sensitivity in the physiological pH range of 2–8. The PEC membrane pH sensor showed good absorption properties in the near-infrared region (NIR). The membrane showed fast response during a de-doping process (≈90 s), while longer response times are essential for doping processes from the alkaline/neutral pH region to the acidic pH region, which is attributed to the presence of highly acidic sulfonic acid groups with a high buffering capacity in the PEC membrane. The SPEEK-PANI membrane exhibited slightly higher water uptake compared to the neat SPEEK membrane. The membrane exhibited good stability, as it was stored in 1M HCl solution for more than 2 years without physical or visual deterioration. A preconditioning step in 1M HCl ensured that the results were reproducible and allows the pH sensor to be used repeatedly. The PEC sensor membranes are suitable for applications that start at low pH values and move upwards to higher pH values in the 2–8 pH range.


2003 ◽  
Vol 57 (1) ◽  
pp. 73-79 ◽  
Author(s):  
Alan G. Ryder ◽  
Sarah Power ◽  
Thomas J. Glynn

We report a novel fluorescence-lifetime-based pH sensing method that utilizes acridine incorporated into Nafion (AcNaf) as the fluorescent indicator. The AcNaf sensor is excited using a 380 nm light emitting diode (LED) and the fluorescence lifetimes are measured at 450 and 500 nm. The fluorescence behavior of acridine as a function of pH in aqueous phosphate buffers and incorporated into the Nafion membrane has been investigated. The results show that incorporating acridine into Nafion changes the apparent ground-state pKa from ∼5.45 to ∼9, while the apparent excited-state pKa* is only slightly changed (∼9.4 in 0.1 M phosphate buffer). The AcNaf film shows a good pH response with a change in average lifetime of ∼19 ns (at an emission wavelength of 450 nm) over the pH 8 to 10 range. We also show that excited-state protonation does not occur in the AcNaf sensor film and that chloride quenching cannot occur because of the permselective nature of Nafion. We also discuss how the unique structure of Nafion affects the fluorescence behavior of acridine at various pH values and examine the impact of buffer concentration on apparent pKa and pH sensing ability.


2000 ◽  
Vol 628 ◽  
Author(s):  
Mark A. Clarner ◽  
Michael J. Lochhead

ABSTRACTOrganically modified silica gels and dye-doped silica gels have been patterned into micrometer-scale structures on a substrate using micro molding in capillaries (MIMIC). This approach is from a class of elastomeric stamping and molding techniques collectively known as soft lithography. Soft lithography and sol-gel processing share attractive features in that they are relatively benign processes performed at ambient conditions, which makes both techniques compatible with a wide variety of organic molecules, molecular assemblies, and biomolecules. The combination of sol-gel and soft lithography, therefore, holds enormous promise as a tool for microfabrication of materials with optical, chemical, or biological functionality that are not readily patterned with conventional methods. This paper describes our investigation of micro-patterned organic-inorganic hybrid materials containing indicator dyes for microfluidic sensor applications. Reversible colorimetric pH sensing via entrapped reagents is demonstrated in a prototype microfluidic sensor element. Patterned structures range from one to tens of micrometers in cross-section and are up to centimeters in length. Fundamental chemical processing issues associated with mold filling, cracking and sensor stability are discussed.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 42
Author(s):  
Shimrith Paul Shylendra ◽  
Wade Lonsdale ◽  
Magdalena Wajrak ◽  
Mohammad Nur-E-Alam ◽  
Kamal Alameh

In this work, a solid-state potentiometric pH sensor is designed by incorporating a thin film of Radio Frequency Magnetron Sputtered (RFMS) Titanium Nitride (TiN) working electrode and a commercial Ag|AgCl|KCl double junction reference electrode. The sensor shows a linear pH slope of −59.1 mV/pH, R2 = 0.9997, a hysteresis as low as 1.2 mV, and drift below 3.9 mV/h. In addition, the redox interference performance of TiN electrodes is compared with that of Iridium Oxide (IrO2) counterparts. Experimental results show −32 mV potential shift (E0 value) in 1 mM ascorbic acid (reducing agent) for TiN electrodes, and this is significantly lower than the −114 mV potential shift of IrO2 electrodes with sub-Nernstian sensitivity. These results are most encouraging and pave the way towards the development of miniaturized, cost-effective, and robust pH sensors for difficult matrices, such as wine and fresh orange juice.


2019 ◽  
Vol 43 (46) ◽  
pp. 18012-18017 ◽  
Author(s):  
Fangjian Cai ◽  
Fei Xia ◽  
Yingxin Guo ◽  
Weihua Zhu ◽  
Bo Fu ◽  
...  

We herein reported the synthesis and pH sensing property of a novel gallium corrole derivatives based on 8-hydroxyquinoline. Ga-corrole derivative showed good fluorescent response upon changing the pH values in the wide region of pH 1 to 12.


Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 709 ◽  
Author(s):  
Esther Tanumihardja ◽  
Wouter Olthuis ◽  
Albert van den Berg

A ruthenium oxide (RuOx) electrode is being developed as potentiometric pH sensor for organs-on-chip applications. Open-circuit potential (OCP) of the RuOx electrode showed a response of −58.05 mV/pH, with no cross-sensitivity to potentially interfering/complexing ions (tested were lithium, sulfate, chloride, and calcium ions). Similar response was observed in complex biological medium. The electrode stored in liquid had a long-term drift of −0.8 mV/hour (corresponding to ΔpH of 0.013/hour) and response time in complex biological medium was 3.7 s. Minimum cross-sensitivity to oxygen was observed as the OCP shifted ~3 mV going from deoxygenated to oxygenated solution. This response is one magnitude lower than previously reported for metal- oxide pH sensors. Overall, the RuOx pH sensor has proven to be a suitable pH sensor for organs- on-chip applications.


Author(s):  
Muhittin Yağmur Polat ◽  
Abdullah Beyaz ◽  
İbrahim Çilingir

Liquid chemical fertilizers are widely used in modern agriculture. The pH values of these fertilizers are important in terms of their effectiveness in the field application and their effect on the soil-water pH balance. Therefore, it is necessary to measure the pH and other properties of liquid fertilizers with fast, practical and inexpensive methods. With the advancing technology, pH value has been started to measure more accurately and efficiently with the help of low-cost devices. In this study, a low-cost pH meter was developed using a low-cost pH sensor, an Arduino UNO R3 microcontroller board, and a software written in the C/C++ programming language. The developed pH meter was used to measure the pH values of liquid chemical fertilizers. Close variations were observed between the values obtained from it and the values measured by an accredited, laboratory-type pH meter. According to the pH measurements of the two pH meters, R2 ranged 88.1% to 99.3%, average error range 0.14 to 0.28, and average error percentage ranged 1.56% to 6.81% for three different types of liquid fertilizers. In light of these results, it was shown that the developed low-cost pH meter can be useful for practical pH measurement applications.


Molecules ◽  
2021 ◽  
Vol 26 (21) ◽  
pp. 6747
Author(s):  
Beatričė Razmienė ◽  
Eva Řezníčková ◽  
Vaida Dambrauskienė ◽  
Radek Ostruszka ◽  
Martin Kubala ◽  
...  

A library of 2,4,6,7-tetrasubstituted-2H-pyrazolo[4,3-c]pyridines was prepared from easily accessible 1-phenyl-3-(2-phenylethynyl)-1H-pyrazole-4-carbaldehyde via an iodine-mediated electrophilic cyclization of intermediate 4-(azidomethyl)-1-phenyl-3-(phenylethynyl)-1H-pyrazoles to 7-iodo-2,6-diphenyl-2H-pyrazolo[4,3-c]pyridines followed by Suzuki cross-couplings with various boronic acids and alkylation reactions. The compounds were evaluated for their antiproliferative activity against K562, MV4-11, and MCF-7 cancer cell lines. The most potent compounds displayed low micromolar GI50 values. 4-(2,6-Diphenyl-2H-pyrazolo[4,3-c]pyridin-7-yl)phenol proved to be the most active, induced poly(ADP-ribose) polymerase 1 (PARP-1) cleavage, activated the initiator enzyme of apoptotic cascade caspase 9, induced a fragmentation of microtubule-associated protein 1-light chain 3 (LC3), and reduced the expression levels of proliferating cell nuclear antigen (PCNA). The obtained results suggest a complex action of 4-(2,6-diphenyl-2H-pyrazolo[4,3-c]pyridin-7-yl)phenol that combines antiproliferative effects with the induction of cell death. Moreover, investigations of the fluorescence properties of the final compounds revealed 7-(4-methoxyphenyl)-2,6-diphenyl-2H-pyrazolo[4,3-c]pyridine as the most potent pH indicator that enables both fluorescence intensity-based and ratiometric pH sensing.


2015 ◽  
Vol 146 (5) ◽  
pp. 343-356 ◽  
Author(s):  
Vladimir V. Cherny ◽  
Deri Morgan ◽  
Boris Musset ◽  
Gustavo Chaves ◽  
Susan M.E. Smith ◽  
...  

Part of the “signature sequence” that defines the voltage-gated proton channel (HV1) is a tryptophan residue adjacent to the second Arg in the S4 transmembrane helix: RxWRxxR, which is perfectly conserved in all high confidence HV1 genes. Replacing Trp207 in human HV1 (hHV1) with Ala, Ser, or Phe facilitated gating, accelerating channel opening by 100-fold, and closing by 30-fold. Mutant channels opened at more negative voltages than wild-type (WT) channels, indicating that in WT channels, Trp favors a closed state. The Arrhenius activation energy, Ea, for channel opening decreased to 22 kcal/mol from 30–38 kcal/mol for WT, confirming that Trp207 establishes the major energy barrier between closed and open hHV1. Cation–π interaction between Trp207 and Arg211 evidently latches the channel closed. Trp207 mutants lost proton selectivity at pHo >8.0. Finally, gating that depends on the transmembrane pH gradient (ΔpH-dependent gating), a universal feature of HV1 that is essential to its biological functions, was compromised. In the WT hHV1, ΔpH-dependent gating is shown to saturate above pHi or pHo 8, consistent with a single pH sensor with alternating access to internal and external solutions. However, saturation occurred independently of ΔpH, indicating the existence of distinct internal and external pH sensors. In Trp207 mutants, ΔpH-dependent gating saturated at lower pHo but not at lower pHi. That Trp207 mutation selectively alters pHo sensing further supports the existence of distinct internal and external pH sensors. Analogous mutations in HV1 from the unicellular species Karlodinium veneficum and Emiliania huxleyi produced generally similar consequences. Saturation of ΔpH-dependent gating occurred at the same pHo and pHi in HV1 of all three species, suggesting that the same or similar group(s) is involved in pH sensing. Therefore, Trp enables four characteristic properties: slow channel opening, highly temperature-dependent gating kinetics, proton selectivity, and ΔpH-dependent gating.


2021 ◽  
Author(s):  
Shaiful Bakhtiar Hashim ◽  
Zurita Zulkifli ◽  
Sukreen Hana Herman

Abstract A SPICE model for extended-gate field-effect transistor (EGFET) based pH sensor was developed using standard discrete components. Capacitors and resistors were used to represent the sensing and reference electrodes in the EGFET sensor system and the values of the discrete component were varied to see the output of the transistor. These variations were done to emulate the EGFET sensor output in different pH values. It was found that the experimental transfer and output characteristics of the EGFET were very similar to those from the SPICE simulation. Other than that, the changes of value components in the equivalent circuit did not affect the transfer and output characteristics graph, but the capacitor value produced significant output variation in the simulation. This can be related to the modification on the equivalent circuit was done with additional voltage, VSB (source to bulk) to produce the different VT values at different pH.