scholarly journals Analytical Model for Load–Slip Relationship of Perfobond Shear Connector Based on Push-Out Test

Materials ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 29 ◽  
Author(s):  
Shuangjie Zheng ◽  
Chen Zhao ◽  
Yangqing Liu

In composite structures, the perfobond connector is an alternative type of shear connector which consists of a steel plate with a certain number of holes. The load–slip relationship is critical for structural analysis and numerical simulation of composite structures using perfobond connectors. In this study, push-out tests were conducted on 72 specimens to obtain the load–slip behaviors of perfobond connectors. Based on the test results, parametric study was performed to analyze the effects of changing the hole geometry, the concrete strength, the configuration of the rebar in hole, the dimensions of the perfobond rib, and the size of the concrete slab. Furthermore, the characteristics and physical meanings of the load–slip curves were analyzed, and the limits and conditions for theoretical expressions were derived. Finally, an analytical model was proposed to express the load–slip relationship of perfobond connectors covering a wide range of design variables.

Materials ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 2958 ◽  
Author(s):  
Jun Chen ◽  
Wei Wang ◽  
Fa-Xing Ding ◽  
Ping Xiang ◽  
Yu-Jie Yu ◽  
...  

The high-strength bolt shear connector in prefabricated concrete slab has advantages in applications as it reduces time during the construction of steel-concrete composite building structures and bridges. In this research, an innovative and advanced bolt shear connector in steel-concrete composite structures is proposed. To investigate the fundamental mechanical behavior and the damage form, 22 static push-off tests were conducted with consideration of different bolt dimensions, the reserved hole constraint condition, and the dimension of slab holes. A finite element (FE) model was established and verified by using test results, and then the model was utilized to investigate the influence of concrete strength, bolt dimension, yield strength, bolt pretension, as well as length-to-diameter ratio of high strength bolts on the performances of shear connectors. On the basis of FE simulation and test results, new design formulas for the calculation of shear resistance behavior were proposed, and comparisons were made with current standards, including AISC, EN 1994-1-1, GB 50017-2017, and relevant references, to check the calculation efficiency. It is confirmed that the proposed equation is in better agreement with the experimental results.


2011 ◽  
Vol 250-253 ◽  
pp. 2396-2406
Author(s):  
Shu Tong Yang

Ground anchors have been very practical in a wide range of geotechnical structures. Good bond properties at the anchor-mortar and mortar-rock interfaces can ensure transmitting an applied tensile load to a load bearing structure efficiently. The bond performance between the mortar and rock is necessary to be studied. A push-out test of mortar from rock block can be used to analyze the interfacial properties between the two materials. In this paper, an analytical model is proposed to determine the push-out capacity of mortar from rock block. Based on the deformation compatibility at the interface, the compressive stress in the mortar and the interfacial shear stress at the mortar-rock interface are formulated at different loading stages. By modeling interfacial debonding as an interfacial shear crack, the push-out load is then expressed as a function of the interfacial crack length. In virtue of the Lagrange Multiplier Method, the maximum push-out load is determined. The validity of the proposed model is verified with the experimental results. It can be concluded that if the interfacial parameters at the mortar-rock interface are obtained, the push-out capacity of mortar from rock block can be accurately determined using the proposed model. The proposed solution in this paper would provide a good theoretical basis in evaluating the stability of ground anchors in practice.


2010 ◽  
Vol 163-167 ◽  
pp. 2137-2141
Author(s):  
Lin Xiao ◽  
Shi Zhong Qiang ◽  
Xun Xu

PBL shear connector is a recently developed shear connector for steel-concrete composite structure that making the two element work as a unique piece. In this work, model test has been carried out to investigate the mechanical characteristics of 21 specimens in 7 types of PBL connectors. Combining the model test with finite element simulation, the main work has been done as follows:Load transfer behavior, load-slippage rule and static load mechanical property of PBL have been analyzed. Research on main factors that could influence the mechanical characteristic of PBL has also been conducted. Based on comparison of results of model test and finite element analysis, the feasibility of push-out simulation by nonlinear FEM has been analyzed. Compared to typical push-out tests results in mainland China, recommendations of push-out test of PBL are presented.


2010 ◽  
Vol 163-167 ◽  
pp. 11-15
Author(s):  
Wen Qi Hou ◽  
Mei Xin Ye ◽  
Ye Zhi Zhang

Abstract. In the presented paper, reverse push-out test method was put forward and applied in the ultimate bearing capacity experiments of studs with concrete slab in tension. Ultimate bearing capacity experiments were carried out on 22 reverse push-out specimens composed of C50 or C40 concrete, 14MnNbq steel girder and Φ22studs. Results showed that ultimate bearing capacity of studs, pu, in tensile concrete slab is controlled by concrete failur, concrete strength, studs arragement and reinforcement ratio are the main influence factors of pu. Compared with that in compressive concrete, pu of Φ22 studs in tensile concrete is reduced about 30% averagely. According to the test results, a fitted load-slip relationship curve and a regression formula of pu for studs in tensile concrete were put forward, calculated results were in good agreement with the test results.


2012 ◽  
Vol 512-515 ◽  
pp. 1991-1994
Author(s):  
Yang Wang ◽  
Tian Li

A new stud—double-nut stud was present. The goals of the study were two fold, firstly to compare with traditional stud and secondly to search the affect factors of capacity, get calculation equations .We present an analysis of double-nut stud, include different concrete strength and different stud size. This study showed double-nut stud is better than traditional stud, for it has higher shearing stiffness and bearing capacity, makes steel beam and the concrete slab to work together. These results suggest that all equations of stud are not applicable computation double -nut stud, it should make 1.35-1.5 adjustment coefficient.


2019 ◽  
Vol 24 (2) ◽  
pp. 96
Author(s):  
Rahma Nindya Ayu Hapsari ◽  
Ilham Nurhuda ◽  
Nuroji Nuroji

Composite structures of concrete slabs and steel beams require shear connectors to transfer shear force between steel beams and concrete slabs. The strength of stud shear connector specified on SNI 03-1729-2013 only considers the effect of stud diameter, however the length of a stud may influence its behavior and strength. This research observes the effects of length and diameter (𝓁/𝒹) of shear connectors on the strength. This research was conducted using the push out method explain in AS-4347- Part I. The test specimens observed in this research were concrete and steel composites, composing IWF 350x175x11x14 mm and concrete blocks of size 450x225x160 mm. The studs were made of steel reinforcements with diameter (𝒹) of 10, 16 and 22 mm, were welded on IWF with 5 mm weld thickness. The length of studs for each stud diameter were 4d, 5d, and 6d. The results indicate that the increase in stud diameter will increase the load capacity of stud. The length of studs effect its load capacity. A slim stud experiences large bending moment at the base of the shear connector. The results show that the highest value of load capacity is measured at specimens with 𝓁/𝒹 ratio of 5.


2018 ◽  
Vol 7 (3.10) ◽  
pp. 54
Author(s):  
T Subramani ◽  
A Periasamy

Composite plays a vital role in replacing the existing mild steel in reinforcement and exterior truss structure. This study proposed to design shear connector for joining concrete slab and steel section. Shear connectors has analyzed and predict the best connector for a particular composite beam with respect to static load and the amount of steel in the connector as a common aspect. The use of composite structures is increasingly present in civil construction works nowadays. Composite beams, especially, are structures which include substances, a metal phase placed in particular inside the tension region and a concrete phase, positioned in the compression go sectional location, both are related with the aid of steel gadgets called shear connectors. The main features of this connector are to permit the weight for the joint the beam-column, to restriction longitudinal slipping and uplifting on the factors interface the shear forces. Our project paper presents 3D numerical models of steel-concrete composite beams to simulate their structural behaviour, with emphasis on the beam column interface using Simulations software ANSYS 18.1 based on the Finite Element Method. Mostly these type of structures are widely used in the dynamic loading structures like bridges and high rise buildings.  


1992 ◽  
Vol 19 (1) ◽  
pp. 1-10 ◽  
Author(s):  
M. R. Veldanda ◽  
M. U. Hosain

This paper summarizes the results of tests performed on 48 push-out specimens to investigate the feasibility of using perfobond rib type shear connectors in composite beams with ribbed metal decks placed parallel to the steel beams. The perfobond rib shear connector is a flat steel plate containing a number of holes. The results indicate that perfobond rib connectors can be effectively used in composite beams with ribbed metal decks placed parallel to the steel beams. An appreciable improvement in performance was observed in test specimens when additional reinforcing bars were passed through the perfobond rib holes. Shank shear was the principal mode of failure in specimens with headed studs. In specimens with perfobond rib, failure was triggered by the longitudinal splitting of the concrete slab, followed by the crushing of concrete in front of the perfobond rib. Key words: composite beam, shear connector, perfobond rib, headed stud, push-out test, metal deck.