scholarly journals Incorporating Kinetic Modeling in the Development Stages of Hard Rock Mine Projects

Minerals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1306
Author(s):  
Youssef Toubri ◽  
Denys Vermette ◽  
Isabelle Demers ◽  
Nicholas Beier ◽  
Mostafa Benzaazoua

Weathering cell test, designed specifically to overcome material-limited constraints, yields prompt and efficient experimental assessment during the development stages of mining projects. However, it has barely benefited from geochemical modeling tools despite their ease of use. Accordingly, this paper aims to strengthen the upstream geochemical assessment via parametric analysis that simulates the effect of various mineral assemblages on leachate quality recovered from weathering cells. The main objective is to simulate the pH in presence of silicate neutralizing minerals and Mn release from carbonates based upon minimal characterization data. The public domain code PHREEQC was used for geochemical kinetic modeling of four weathering cells. The kinetic model utilized a water film concept to simulate diffusion of chemical elements from mineral surfaces to the pore water. The obtained results suggest that the presence of the silicate neutralizing minerals slightly affects the Mn release from carbonates. Furthermore, plagioclases could supply a significant neutralization potential when they predominate the mineral assemblage. Finally, coupling weathering cell test and parametric analyses illuminate the pH evolution for various mineral proportion scenarios.

Minerals ◽  
2018 ◽  
Vol 8 (10) ◽  
pp. 444 ◽  
Author(s):  
Pavlína Hájková

This work describes the role of chemical composition and curing conditions in geopolymer strength, leachability of chemical elements and porosity. The study focuses on geopolymer material prepared from calcined kaolinite claystone, which is not studied frequently as a raw material for geopolymer production, although it has a high application potential as it is easily commercially available and allows preparation of geopolymers with low viscosity. The composition of geopolymers and their curing methods were selected considering their ease of use in the praxis. Therefore, the potassium water glass itself was used as alkali activator without any KOH or NaOH addition. Chemical composition was changed only by the density of water glass in the range of 1.2 to 1.6 g·cm−3. Geopolymers were cured at a temperature within the range of 5 °C–70 °C to speed up the solidification process as well as by microwave radiation. High compressive strengths were obtained for geopolymers with the highest densities of the water glass (1.5 and 1.6 g·cm−3) in dependence on various curing conditions. Higher strengths were achieved in the case of samples where the solidification was not accelerated. The samples cured at lower temperatures (5 °C) showed lower porosity compared to the other curing types. The lowest leachability of Si and alkalis was reached for the samples with water glass density 1.5 g·cm−3.


2014 ◽  
Vol 64 ◽  
pp. 78-91 ◽  
Author(s):  
Nymphodora Papassiopi ◽  
Christina Zaharia ◽  
Anthimos Xenidis ◽  
Katerina Adam ◽  
Alexandros Liakopoulos ◽  
...  

2015 ◽  
Vol 26 (1) ◽  
pp. 29-42
Author(s):  
Subhro Mitra ◽  
Elvis Ndembe ◽  
Poyraz Kayabas

The purpose of this paper is to review logistics concepts used in macro freight transportation modeling by various planning agencies at the national, state and city level. The chronological development of freight modeling endeavors are studied here and the logistics component incorporated in the modeling is identified. The key modeling tools are identified and analyzed to identify the efficacy of the model, ease of use, and data required to implement the model. The conclusion was that European freight models were more developed than North American freight models. The tools most widely used are the aggregate-disaggregate-aggregate model, input-output model, artificial neural network model, matrix estimation method and PCOD model. This paper will give transportation modelers a better idea of the freight modeling tools available.


2012 ◽  
Vol 66 (7) ◽  
pp. 1502-1510 ◽  
Author(s):  
S. K. Singh ◽  
Prashant K. Srivastava ◽  
M. Gupta ◽  
S. Mukherjee

This research paper aims to determine the genetic origin of the chemical elements in groundwater. It deals with the results of physicochemical parameters, to evaluate the hydro-geochemistry of groundwater in rural-urban fringe of district Bareilly, India. Pre- and post-monsoon sampling has been carried out, which reveals inter-seasonal variability effect on the hydro-geochemical processes. Geochemical modeling especially computation of saturation index was undertaken using the WATEQ4F model. Majority of samples fall in the category of undersaturation, which further suggests that groundwater still has potential to dissolve more minerals. Chemical categorizations of groundwater samples were performed with the help of the Aquachem model. Grouping of groundwater on the Piper diagram reveals a common composition and origin. In most of the area, water facies is of Ca2+−HCO3− type in both the seasons. It also indicates that in pre-monsoon, ion exchange is the dominant process, whereas in post-monsoon, both ion exchanges as well as reverse ion exchanges are reported in the groundwater of the study area.


1976 ◽  
Vol 32 ◽  
pp. 169-182
Author(s):  
B. Kuchowicz

SummaryIsotopic shifts in the lines of the heavy elements in Ap stars, and the characteristic abundance pattern of these elements point to the fact that we are observing mainly the products of rapid neutron capture. The peculiar A stars may be treated as the show windows for the products of a recent r-process in their neighbourhood. This process can be located either in Supernovae exploding in a binary system in which the present Ap stars were secondaries, or in Supernovae exploding in young clusters. Secondary processes, e.g. spontaneous fission or nuclear reactions with highly abundant fission products, may occur further with the r-processed material in the surface of the Ap stars. The role of these stars to the theory of nucleosynthesis and to nuclear physics is emphasized.


Author(s):  
Gianluigi Botton ◽  
Gilles L'espérance

As interest for parallel EELS spectrum imaging grows in laboratories equipped with commercial spectrometers, different approaches were used in recent years by a few research groups in the development of the technique of spectrum imaging as reported in the literature. Either by controlling, with a personal computer both the microsope and the spectrometer or using more powerful workstations interfaced to conventional multichannel analysers with commercially available programs to control the microscope and the spectrometer, spectrum images can now be obtained. Work on the limits of the technique, in terms of the quantitative performance was reported, however, by the present author where a systematic study of artifacts detection limits, statistical errors as a function of desired spatial resolution and range of chemical elements to be studied in a map was carried out The aim of the present paper is to show an application of quantitative parallel EELS spectrum imaging where statistical analysis is performed at each pixel and interpretation is carried out using criteria established from the statistical analysis and variations in composition are analyzed with the help of information retreived from t/γ maps so that artifacts are avoided.


Author(s):  
Philippe Fragu

The identification, localization and quantification of intracellular chemical elements is an area of scientific endeavour which has not ceased to develop over the past 30 years. Secondary Ion Mass Spectrometry (SIMS) microscopy is widely used for elemental localization problems in geochemistry, metallurgy and electronics. Although the first commercial instruments were available in 1968, biological applications have been gradual as investigators have systematically examined the potential source of artefacts inherent in the method and sought to develop strategies for the analysis of soft biological material with a lateral resolution equivalent to that of the light microscope. In 1992, the prospects offered by this technique are even more encouraging as prototypes of new ion probes appear capable of achieving the ultimate goal, namely the quantitative analysis of micron and submicron regions. The purpose of this review is to underline the requirements for biomedical applications of SIMS microscopy.Sample preparation methodology should preserve both the structural and the chemical integrity of the tissue.


Author(s):  
Ray Keller

The amphibian embryo offers advantages of size, availability, and ease of use with both microsurgical and molecular methods in the analysis of fundamental developmental and cell biological problems. However, conventional wisdom holds that the opacity of this embryo limits the use of methods in optical microscopy to resolve the cell motility underlying the major shape-generating processes in early development.These difficulties have been circumvented by refining and adapting several methods. First, methods of explanting and culturing tissues were developed that expose the deep, nonepithelial cells, as well as the superficial epithelial cells, to the view of the microscope. Second, low angle epi-illumination with video image processing and recording was used to follow patterns of cell movement in large populations of cells. Lastly, cells were labeled with vital, fluorescent dyes, and their behavior recorded, using low-light, fluorescence microscopy and image processing. Using these methods, the details of the cellular protrusive activity that drives the powerful convergence (narrowing)


Author(s):  
Judith M. Brock ◽  
Max T. Otten

A knowledge of the distribution of chemical elements in a specimen is often highly useful. In materials science specimens features such as grain boundaries and precipitates generally force a certain order on mental distribution, so that a single profile away from the boundary or precipitate gives a full description of all relevant data. No such simplicity can be assumed in life science specimens, where elements can occur various combinations and in different concentrations in tissue. In the latter case a two-dimensional elemental-distribution image is required to describe the material adequately. X-ray mapping provides such of the distribution of elements.The big disadvantage of x-ray mapping hitherto has been one requirement: the transmission electron microscope must have the scanning function. In cases where the STEM functionality – to record scanning images using a variety of STEM detectors – is not used, but only x-ray mapping is intended, a significant investment must still be made in the scanning system: electronics that drive the beam, detectors for generating the scanning images, and monitors for displaying and recording the images.


Sign in / Sign up

Export Citation Format

Share Document