scholarly journals Comparison of Fracture Load of the Four Translucent Zirconia Crowns

Molecules ◽  
2021 ◽  
Vol 26 (17) ◽  
pp. 5308
Author(s):  
Suchada Kongkiatkamon ◽  
Kittipong Booranasophone ◽  
Apichat Tongtaksin ◽  
Valailuck Kiatthanakorn ◽  
Dinesh Rokaya

Recently, translucent zirconia has become the most prevalent material used as a restorative material. This study aimed to compare the crown fracture load of the four most common different translucent zirconia brands available in the market at 1.5 mm thickness. Standardized tooth preparations for a full ceramic crown were designed digitally with software (AutoCAD) by placing a 1.0 mm chamfer margin and 1.5 mm occluso-cervical curvature for the crown sample manufacturing. Stylized crowns were chosen to control the thickness of the crown. The axial and occlusal thickness were standardized to 1.5 mm thickness except at the central pit, which was 1.3 mm thick. The STL file for the tooth dies was prepared using software (3Shape TRIOS® Patient Monitoring, Copenhagen, Denmark). The tooth dies were printed with a resin material (NextDent Model 2.0, Vertex-Dental B.V., Soesterberg, The Netherlands) using a 3D printing software (3D Sprint® Client Version 3.0.0.2494) from a 3D printer (NextDent™ 5100, Vertex-Dental B.V., Soesterberg, The Netherlands). The printing layer thickness was 50 µm. Then, a total of twenty-eight (N = 28) stylized crowns were milled out of AmannGirrbach (Amann Girrbach GmbH, Pforzheim, Germany) (n = 7), Cercon HT (Dentsply Sirona, Bensheim, Germany) (n = 7), Cercon XT (Dentsply Sirona, Bensheim, Germany) (n = 7), and Vita YZ XT (Zahnfabrik, Bäd Sackingen, Germany) (n = 7). Following sintering the crowns, sandblasting was performed and they were bonded to the tooth dies with the resin cement (RelyX U-200, 3M ESPE, Seefeld, Germany) and permitted to self-cure under finger pressure for 6 min. The crowns were loaded on the occlusal surface in a universal testing machine (MTS Centurion) with a stainless-steel ball indenter (7 mm radius) with a loading rate of 1 mm/min to contact the stylized crowns on each of the four cusps until failure. A rubber sheet (1.5 mm thickness) was positioned between the crown and indenter, which helped with the load distribution. Statistical analysis was done using SPSS version 20 (IBM Company, Chicago, USA). The fracture loads were analyzed using Dunnett’s T3 test, and the number of cracks was analyzed using the Mann–Whitney U test among the groups. The significant level was set at p value = 0.05. The mean fracture loads were 3086.54 ± 441.74 N, 4804.94 ± 70.12 N, 3317.76 ± 199.80 N, and 2921.87 ± 349.67 N for AmannGirrbac, Cercon HT, Cercon XT, and Vita YZ XT, respectively. The mean fracture loads for the surfaces with the greatest number of cracks (excluding the occlusal surfaces) were on the lingual surface for AmannGirrbach and Cercon HT, on the distal and mesial for Cercon XT, and on the buccal for Vita YZ XT. We found that the AmannGirrbach had the most overall cracks. Cercon XT had the greatest number of occlusal cracks and appeared to be the most shattered. Cercon HT had the least number of cracks. In conclusion, Cercon HT presented the best strength properties, the highest fracture load, and no visible cracks. AmannGirrbach presented the lowest strength properties.

2003 ◽  
Vol 11 (1) ◽  
pp. 61-67 ◽  
Author(s):  
Osvaldo Daniel Andreatta Filho ◽  
Marco Antonio Bottino ◽  
Renato Sussumu Nishioka ◽  
Luiz Felipe Valandro ◽  
Fabíola Pessoa Pereira Leite

The aim of the present study was to evaluate the effect of thermocycling on the bond strength between the surface of the glass-infiltrated alumina ceramic In-Ceram (VITA) and the Panavia F resin cement (Kuraray CO.). Four 5x6x6mm In-Ceram blocks were obtained. One of the 6x6mm faces of each block was conditioned with Cojet - System (tribochemical silica coating, ESPE-3M) and then luted under a constant 750g pressure with Panavia F cement to another identical face of a resin composit block (Clearfil AP-X, Kuraray) obtained by reproduction of the ceramic one from Express (3M) addition curing silicone impressions. The four sets so formed by ceramic, luting cement and resin have been each one serially sectioned in 20 sticks so that the adhesive surface in each presented 1mm² of area. The samples were divided in 2 groups (n=10): G1- stored for 7 days in deionized water at 36 ± 2ºC; G2 - thermocycled 1500 times between 5 and 55ºC dwell times. The microtensile tests were accomplished in an universal testing machine (EMIC) at a crosshead speed of 0,5 mm/min. The results showed that the mean tensile bond strength values (MPa) for the group G2: (22,815 ± 5,254) had not statistically differ of the values of group G1: (25,628 ± 3,353) (t = 1,427; gl = 18; p-value = 0,171), at the level of a= 5%. It can be concluded that the thermocycling technique used in the present experiment had not produced statistically significant differences between the bond strength results of the specimens obtained by the two used techniques.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Niwut Juntavee ◽  
Sasiprapa Kornrum

Introduction. Monolithic zirconia is able to achieve certain aesthetic, but its durability in resisting fracture has been questioned, as fractures often originate from margins of restoration. This study determined fracture resistance of highly translucent monolithic zirconia crowns with different margin designs in terms of marginal thickness and collar height. Materials and Methods. Zirconia blanks (Ceramill® Zolid HT+) were selected for the fabrication of zirconia crowns according to different designs, including varying margin thicknesses (light chamfer, CL; heavy chamfer, CH) and collar heights (no collar, NC; low collar, LC; high collar, HC), which resulted in CLNC, CLLC, CLHC, CHNC, CHLC, and CHHC groups (15 crowns each). The crowns were seated on a metal die and loaded vertically through round end punch (θ = 10 mm), contacting with inclined planes of cusp in a testing machine with crosshead speed of 0.2 mm/min until fracture. Videos with a rate of 50 frames/second were used to record fracture. Fracture load (N) and durable period (s) were compared for significant differences using ANOVA and Bonferroni test (α = 0.05). Results. The mean ± sd of fracture load (N) and durable time (s) were 3211 ± 778 and 212 ± 47 for CLNC; 3041 ± 1370 and 188 ± 53 for CLLC; 2913 ± 828 and 192 ± 27 for CLHC; 4226 ± 905 and 245 ± 35 for CHNC; 4486 ± 807 and 228 ± 29 for CHLC; and 4376 ± 1043 and 227 ± 37 for CHHC. This indicated that marginal thickness had a significant influence on load-bearing capacity and durable time (p<0.05). No significant impact of collar height was shown, either on load-bearing capacity or durable time (p>0.05). No interaction between two factors was presented (p>0.05). Conclusions. Heavy chamfer margin provided stronger zirconia crown than light chamfer, but both were capable of withstanding fracture load higher than maximum masticatory force. Neither presence nor absence of collar indicated any impact on strength. Fabrication of zirconia crowns with either heavy or light chamfer margin and either presence or absence of collar, with the consideration of emergence profile, should be considered.


2020 ◽  
Vol 14 (02) ◽  
pp. 245-249
Author(s):  
Haider Hasan Jasim ◽  
Meelad Basil Findakly ◽  
Nada Ali Mahdi ◽  
Mustafa Tariq Mutar

Abstract Objectives The aim of this study was to compare the effects of two margin designs (shoulderless and slight chamfer) with two occlusal thicknesses on fracture resistance and failure mode of the monolithic zirconia crowns. Materials and Methods Forty nickel–chromium dies were duplicated from the previous two prepared teeth using a three-dimensional optical scanner. Nickel–chromium supporting dies were divided into two main groups (n = 20) according to the type of margin design: group A, slight chamfer margin design and group B, shoulderless margin design. These groups were further divided into two subgroups according to the occlusal thicknesses (0.5 and 1 mm). The digital imaging of each die was done using a three-dimensional optical scanner, then zirconia blocks were milled by 5-axis machine. The crowns were cleaned by alcohol, air dried, and cemented by resin cement. Next, the crowns were subjected to 500 hot and cold cycles (30 seconds for each cycle). The samples were subjected to a static load until failure using an electronic universal testing machine and fracture resistance was recorded in Newton (N). Statistical Analysis Data were analyzed using the test of normality (Shapiro–Wilk test) and two-way analysis of variance (ANOVA) test. Results  The highest mean fracture load was recorded by the shoulderless (1 mm occlusal thickness) subgroup (3,992.5 N), followed by shoulderless (0.5 mm occlusal thickness) subgroup (3,244.4 N), and the slight chamfer (1 mm occlusal thickness) subgroup (2,811 N). The lowest mean of fracture load was recorded by slight chamfer (0.5 mm occlusal thickness) subgroup (1,632.9 N). The two-way ANOVA test revealed a significant difference between the four subgroups. Regarding the fracture mode, the slight chamfer subgroups showed a severe fracture of the restoration while the shoulderless subgroups showed a fracture through the midline of the restoration. Conclusion Within the limitation of the comparative study, shoulderless margin design has a more favorable outcome than a slight chamfer design in all thicknesses. Although the restoration with reduced occlusal thickness has lower fracture resistance than 1 mm occlusal thickness, the 0.5 mm restorations still can tolerate occlusal forces.


2016 ◽  
Vol 41 (5) ◽  
pp. E118-E130 ◽  
Author(s):  
ETP Bergamo ◽  
WJ da Silva ◽  
PF Cesar ◽  
AA Del Bel Cury

SUMMARY Monolithic zirconia crowns have many favorable properties and may potentially be used to solve dental problems such as chipping. However, monolithic zirconia crown resistance can be affected by its phase transformation when subjected to low temperatures, humidity, and stress. This study evaluated the fracture load and phase transformation of monolithic zirconia crowns submitted to different thermal and mechanical aging tests. Seventy monolithic zirconia crowns were randomly divided into the following five groups: control, no treatment; hydrothermal aging at 122°C, two bar for one hour; thermal fatigue, 104 cycles between 5°C and 55°C, dwell time, 30 seconds; and mechanical fatigue, 106 cycles with a load of 70 N, sliding of 1.5 mm at 1.4 Hz; and combination of mechanical plus thermal fatigue. Fracture load was measured with a universal testing machine. Surface changes and fracture mode and origin were examined with a scanning electron microscope. Monoclinic phase content was evaluated by x-ray diffraction. The fracture load was analyzed using one-way analysis of variance at a level of 5%, and Weibull distribution was performed. No statistically significant differences were observed in the mean fracture load and characteristic fracture load among the groups (p&gt;0.05). The Weibull modulus ranged from 6.2 to 16.6. The failure mode was similar for all groups with the crack origin located at the contact point of the indenter. Phase transformation was shown at different surfaces of the crown in all groups (1.9% to 8.9%). In conclusion, monolithic zirconia crowns possess high fracture load, structural reliability, and low phase transformation.


2021 ◽  
Vol 24 (4) ◽  
Author(s):  
Ayman Sabbah ◽  
Mostafa Kamel

Objective: This study aimed to assess the fracture resistance of primary molars restored with endocrowns compared to prefabricated zirconia crowns. Methods: Twelve sound, defect-free primary second molars were selected and divided into two groups: group I included 6 molars restored with zirconia crowns, while group II included 6 teeth restored with endocrowns. For both groups access cavity was prepared for the teeth to open pulp chamber. Fracture resistance of both groups was tested using a universal testing machine. Results: Zirconia crown showed statistically significantly higher mean fracture resistance than Endocrown (P-value = 0.001, Effect size = 2.72). Conclusion: Pulpotomized primary molars restored with Zirconia crowns showed significantly higher mean fracture resistance compared to primary molars restored with endocrowns, meanwhile both restorations have shown higher mean fracture resistance than the maximum biting force in children. Keywords  Composite resins; Endocrown; Fracture strength; Zirconia crowns.


2015 ◽  
Vol 09 (02) ◽  
pp. 218-223 ◽  
Author(s):  
Ebru Kucukyilmaz ◽  
Bilal Yasa ◽  
Merve Akcay ◽  
Selcuk Savas ◽  
Fevzi Kavrik

ABSTRACT Objective: The aim of this study was to investigate the effect of cavity design and the type of pulp capping materials on the fracture resistance of Class II composite restorations. Materials and Methods: Sixty freshly extracted, sound molar teeth were selected for the study. A dovetail cavity on the mesio-occlusal and a slot cavity on disto-occlusal surfaces of each tooth were prepared, and the teeth were divided 4 groups which one of them as a control group. The pulp capping materials (TheraCal LC, Calcimol LC, Dycal) applied on pulpo-axial wall of each cavity, and the restoration was completed with composite resin. The teeth were subjected to a compressive load in a universal mechanical testing machine. The surfaces of the tooth and restoration were examined under a stereomicroscope. The data were analyzed using factorial analysis of variance and Tukey's test. Results: For pulp capping materials, the highest fracture load (931.15 ± 203.81 N) and the lowest fracture load (832.28 ± 245.75 N) were calculated for Control and Dycal group, respectively. However, there were no statistically significant differences among all groups (P > 0.05). The fracture load of the dovetail groups was significantly higher than those of the slot cavity groups (P < 0.05). Conclusion: Dovetail cavity design shows better fracture resistance in Class II composite restorations, independent of used or not used pulp capping materials.


Polymers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 3761
Author(s):  
Simone Shah Abhay ◽  
Dhanraj Ganapathy ◽  
Deepak Nallaswamy Veeraiyan ◽  
Padma Ariga ◽  
Artak Heboyan ◽  
...  

Recently, polyetheretherketone (PEEK) has been introduced to the dental market as a high-performance and chemically inert biomaterial. This study aimed to compare the wear resistance, abrasiveness, color stability, and displacement resistance of zirconia and PEEK milled crowns. An ideal tooth preparation of a first maxillary molar was done and scanned by an intraoral scanner to make a digital model. Then, the prosthetic crown was digitally designed on the CAD software, and the STL file was milled in zirconia (CaroZiir S, Carol Zircolite Pvt. Ltd., Gujarat, India) and PEEK (BioHpp, Bredent GmbH, Senden, Germany) crowns using five-axis CNC milling machines. The wear resistance, color stability, and displacement resistance of the milled monolithic zirconia with unfilled PEEK crowns using a chewing simulator with thermocyclic aging (120,000 cycles) were compared. The antagonist wear, material wear, color stability, and displacement were evaluated and compared among the groups using the Wilcoxon–Mann–Whitney U-test. Zirconia was shown to be three times more abrasive than PEEK (p value < 0.05). Zirconia had twice the wear resistance of PEEK (p value < 0.05). Zirconia was more color stable than PEEK (p value < 0.05). PEEK had more displacement resistance than zirconia (p value < 0.05). PEEK offers minimal abrasion, better stress modulation through plastic deformation, and good color stability, which make it a promising alternative to zirconia crown.


2017 ◽  
Vol 43 (2) ◽  
pp. 87-93 ◽  
Author(s):  
Marcos Alexandre Fadanelli ◽  
Flávia Lucisano Botelho do Amaral ◽  
Roberta Tarkany Basting ◽  
Cecilia Pedroso Turssi ◽  
Bruno Salles Sotto-Maior ◽  
...  

The purpose of this study was to evaluate the effects of steam autoclave sterilization on the tensile strength of two types of resin cements used to bond customized CAD/CAM zirconia abutments onto titanium bases. Forty sets of zirconia abutments cemented to screwed titanium bases of implants analogs were divided into 4 groups (n = 10). Two groups were treated with a conventional chemically activated resin cement (ML, Multilink Ivoclar Vivadent) and the other two groups with a self-adhesive dual resin cement (RelyX U200, 3M ESPE). One group from each cement was submitted to steam autoclaving. The autoclave sterilization cycle was performed after 72 hours of cementation for 15 minutes at 121°C and 2.1 Kgf/cm2. The samples were subjected to tensile strength testing in a universal testing machine (200 Kgf, 0.5 mm/min), from which the means and standard deviations were obtained in Newtons. Results showed (via ANOVA and Tukey's test; α = 0.05) that in the absence of steam autoclaving, no difference was observed in tensile strength between the cements tested: ML: 344.87 (93.79) and U200: 280 (92.42) (P = .314). Steam autoclaving, however, significantly increased tensile strength for the ML: 465.42 (87.87) compared to U200: 289.10 (49.02) (P &lt; .001). Despite the significant increase in the ML samples (P = .013), autoclaving did not affect the tensile strength of the U200 samples (P &gt; 0.05). The authors concluded that steam autoclaving increases the mean tensile strength of the chemically activated cement compared to the dual-cure self-adhesive cement. The performance of both cements evaluated was similar if the sterilization step was disconsidered.


2020 ◽  
Vol 14 (02) ◽  
pp. 200-205 ◽  
Author(s):  
Noor Nawafleh ◽  
Abdel Raheem Bibars ◽  
Elina Al Twal ◽  
Andreas Öchsner

Abstract Objective This study investigates the influence of the most commonly used indenter materials on fatigue survival and fracture resistance of zirconia crowns. Materials and Methods A total of 40 zirconia crowns were prepared using computer-aided design (CAD)/computer-aided manufacturing (CAM) technology: 30 crowns were divided into three experimental groups of 10 specimens and the last 10 specimens acted as the control group. The experimental groups were subjected to chewing simulation with simultaneous thermocycling. Three indenter materials (steatite ceramic, stainless steel, and tungsten carbide) with identical diameter were used to load the specimens. All crowns were then subjected to single load to fracture test in universal testing machine. Load was applied vertically with a crosshead speed of 1 mm/min until failure, and fracture load was recorded. Statistical Analysis Normal distribution of data was confirmed using the Shapiro–Wilk test. Descriptive statistics including means and standard deviations were determined for all groups. Differences between groups were tested using Dunnett’s test and paired sample t-test. Results Chewing simulation for 1.2 million cycles resulted in 100% survival. The highest mean fracture load was recorded for the control group and the lowest one was for the group fatigued with stainless steel indenter. Chewing simulation statistically significantly (p < 0.05) reduced the mean fracture load of the crowns fatigued with stainless steel and steatite ceramic indenter. However, the mean fracture load for the crowns fatigued with tungsten carbide was not significantly different from that of the control group. Conclusion Steatite ceramic and stainless steel indenters produced close results and significantly reduced fracture load of zirconia crowns. However, tungsten carbide indenter caused nonsignificant reduction in the fracture load of zirconia crowns.


Cerâmica ◽  
2018 ◽  
Vol 64 (370) ◽  
pp. 284-287
Author(s):  
A. C. Piccoli ◽  
M. Borba

Abstract Different methods are available to produce all-ceramic dental prosthesis. Each processing step may introduce flaws to the material, which compromises its properties and reliability. The objective of this study was to evaluate the effect of fabrication method on the fracture behavior of prosthetic crowns produced with an alumina-based glass-infiltrated zirconia-reinforced ceramic. Two groups of all-ceramic crowns were produced according to the fabrication method of the infrastructure (IS) (n=30): IZC - IS produced by CAD-CAM; IZS - IS produced by slip-casting. The IS were veneered with porcelain and cemented to fiber-reinforced composite dies with resin cement. Crowns were loaded in compression to failure using a universal testing machine, at 1 mm/min crosshead speed and 37 ºC distilled water. Fractography was performed using stereomicroscope and SEM. Data were statistically analyzed with Student’s t test (α=0.05) and Weibull analysis. There were no significant differences among the experimental groups for fracture load (p=0.481) and Weibull modulus. For both groups, the failure mode was catastrophic failure involving IS and porcelain. It was concluded that the fabrication methods evaluated resulted in all-ceramic crowns with similar fracture behavior and reliability.