scholarly journals Assessing Overall Diet Quality: Development and Evaluation of the Performance of a Short Self-Administrated Questionnaire SCASA

Nutrients ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 677
Author(s):  
Maaike Kruseman ◽  
Angeline Chatelan ◽  
Eddy Farina ◽  
Isabelle Carrard ◽  
Jeremy Cela ◽  
...  

Several tools assessing diet quality have been developed over the last decades, but their use in public health and clinical practice is limited because they necessitate detailed quantitative assessment of food intake. Our goal was to develop and validate a score (Score d’Alimentation Saine, SCASA) based on a short self-administrated online questionnaire to assess overall diet quality. SCASA targets the adult population in French-speaking Switzerland, but it was designed in a way enabling its adaptation for other regions. The choice of the items involved experts and lay volunteers. Construct validation and inter-method reliability were assessed by screening meal plans and by comparing the self-rated scores with food-record derived scores (kappa and Bland–Altman). SCASA (17 components) discriminated adequately balanced from imbalanced meal plans (93–95% and 44–46% of maximal score). Agreement between self-assessed and food record-based scores ranged between >90% (3 items), 80–89% (3 items), 70–79% (4 items), and <70% (5 items). The Bland–Altman plot showed a mean difference of −1.60 (95% CI −2.36 to −0.84), indicating a slight overestimation of the self-assessed diet quality compared to the food record. SCASA offers a reliable way to assess overall diet quality without requiring burdensome data collection or nutrient calculations.

2015 ◽  
Vol 115 (3) ◽  
pp. 517-526 ◽  
Author(s):  
Linde van Lee ◽  
Edith J. M. Feskens ◽  
Saskia Meijboom ◽  
Eveline J. C. Hooft van Huysduynen ◽  
Pieter van’t Veer ◽  
...  

AbstractGenerally, there is a need for short questionnaires to estimate diet quality in the Netherlands. We developed a thirty-four-item FFQ – the Dutch Healthy Diet FFQ (DHD-FFQ) – to estimate adherence to the most recent Dutch guidelines for a healthy diet of 2006 using the DHD-index. The objectives of the present study were to evaluate the DHD-index derived from the DHD-FFQ by comparing it with the index based on a reference method and to examine associations with participant characteristics, nutrient intakes and levels of cardiometabolic risk factors. Data of 1235 Dutch men and women, aged between 20 and 70 years, participating in the Nutrition Questionnaires plus study were used. The DHD-index was calculated from the DHD-FFQ and from a reference method consisting of a 180-item FFQ combined with a 24-h urinary Na excretion value. Ranking was studied using Spearman’s correlations, and absolute agreement was studied using a Bland–Altman plot. Nutrient intakes derived from the 180-item FFQ were studied according to quintiles of the DHD-index using DHD-FFQ data. The correlation between the DHD-index derived from the DHD-FFQ and the reference method was 0·56 (95 % CI 0·52, 0·60). The Bland–Altman plot showed a small mean overestimation of the DHD-index derived from the DHD-FFQ compared with the reference method. The DHD-index score was in the favourable direction associated with most macronutrient and micronutrient intakes when adjusted for energy intake. No associations between the DHD-index score and cardiometabolic risk factors were observed. In conclusion, the DHD-index derived from the DHD-FFQ was considered acceptable in ranking but relatively poor in individual assessment of diet quality.


2021 ◽  
Vol 40 (1) ◽  
Author(s):  
Makeda Sinaga ◽  
Melese Sinaga Teshome ◽  
Tilhun Yemane ◽  
Elsah Tegene ◽  
David Lindtsrom ◽  
...  

Abstract Background Application of advanced body composition measurement methods is not practical in developing countries context due to cost and unavailability of facilities. This study generated ethnic specific body fat percent prediction equation for Ethiopian adults using appropriate data. Methods A cross-sectional study was carried ifrom February to April 2015 among 704 randomly selected adult employees of Jimma University. Ethnic specific Ethiopian body fat percent (BF%) prediction equation was developed using a multivariable linear regression model with measured BF% as dependent variable and age, sex, and body mass index as predictor variables. Agreement between fat percent measured using air displacement plethysmography and body fat percent estimated using Caucasian prediction equations was determined using Bland Altman plot. Results Comparison of ADP measured and predicted BF% showed that Caucasian prediction equation underestimated body fat percent among Ethiopian adults by 6.78% (P < 0.0001). This finding is consistent across all age groups and ethnicities in both sexes. Bland Altman plot did not show agreement between ADP and Caucasian prediction equation (mean difference = 6.7825) and some of the points are outside 95% confidence interval. The caucasian prediction equation significantly underestimates body fat percent in Ethiopian adults, which is consistent across all ethnic groups in the sample. The study developed Ethnic specific BF% prediction equations for Ethiopian adults. Conclusion The Caucasian prediction equation significantly underestimates body fat percent among Ethiopian adults regardless of ethnicity. Ethiopian ethnic-specific prediction equation can be used as a very simple, cheap, and cost-effective alternative for estimating body fat percent among Ethiopian adults for health care provision in the prevention of obesity and related morbidities and for research purposes.


2013 ◽  
Vol 24 (7) ◽  
pp. 1133-1156 ◽  
Author(s):  
Linda A. Pruski ◽  
Sharon L. Blanco ◽  
Rosemary A. Riggs ◽  
Kandi K. Grimes ◽  
Chase W. Fordtran ◽  
...  

Author(s):  
Samaneh Sadat Ayoubi ◽  
Mohsen Nematy ◽  
Maryam Amini ◽  
Habibollah Esmaily ◽  
Sara Movahed ◽  
...  

BACKGROUND: The food frequency questionnaire (FFQ) is the method of choice for dietary assessment in epidemiological studies. FFQs focusing on mixed-dishes and simple food items are useful where mixed-dishes are an essential part of food consumption. OBJECTIVE: Regarding the fact that the nature of the Iranian diet is mixed-dish, the present study aimed to design and assess the validity and reproducibility of a dish-based semi-quantitative FFQ in the Iranian adult population. METHODS: A list of 302 food items was collected from four geographical areas around Iran. The validation study was conducted on 97 healthy adults. The FFQ was introduced at the beginning of the study and 10 months after; two three-day food records were collected during the study. Also, biomarkers including 24-hour urinary potassium and nitrogen, serum retinol, and alpha-tocopherol were measured. RESULTS: A 142-food-item FFQ was concluded. The correlation coefficient between the second FFQ and the second three-day food record ranged from 0.225 to 0.323 for macronutrients and 0.128 to 0.476 for micronutrients. The percentile agreements (same or adjacent quartile) between the two methods were more than 60%for all nutrients. The intraclass correlation coefficient between FFQs (except for vitamin E) ranged from 0.363 to 0.578. The correlation coefficient between the second FFQ and the second biomarker assessment was 0.241 for protein.


2018 ◽  
Vol 2018 ◽  
pp. 1-11 ◽  
Author(s):  
Zhiming Xiang ◽  
Zhu Ai ◽  
Jianke Liang ◽  
Guijin Li ◽  
Xiaolei Zhu ◽  
...  

Purpose. To evaluate the performance of an optimized ECG trigger diffusion weighted imaging (DWI) sequence in liver and its application in liver disease. Materials and Methods. Eighteen healthy volunteers underwent intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) scan of the liver twice in 1.5T MR scanner with signed informed consent approved by local ethic committees. A new method, called cardiac stationary phase based ECG trigger (CaspECG), and FB method were applied. The apparent diffusion coefficient (ADC) and the IVIM parameters, including pure diffusion coefficient (D), perfusion-related diffusion coefficient (D⁎), and perfusion fraction, (PF) were calculated, and then 18 region of interests were drawn on these parameter maps independently by two readers through whole hepatic lobe. The regional variability and reproducibility between two repeated scans were evaluated using interclass correlation coefficients (ICCs) and Bland-Altman plot, respectively, and compared between the CaspECG and FB methods. The signal-to-noise ratio (SNR) of DWI data was also evaluated. Result. Compared to the FB method, the proposed CaspECG method showed significant higher SNRs in DWI data, lower regional variability between left and right hepatic lobes, and higher reproducibility of ADC, PF, D, and D⁎ between repeat scans [left lobe, limit of agreement (LOA) of Bland-Altman plot: 10.1%, 18.3%, 19.8%, and 59.2%; right lobe, LOA: 10.25%, 14.15%, 16.45%, and 39.45%]. D⁎ showed the worst reproducibility in all parameters. Conclusion. The novel CaspECG method outperformed the FB method in compensating the cardiac motion induced artifacts in DWI data and generating more reliable quantitative parameters, with less regional variability and higher repeatability, especially in the left hepatic lobe.


Author(s):  
Marco Binotti ◽  
Francesco Cavallin ◽  
Pier Luigi Ingrassia ◽  
Nicolas J Pejovic ◽  
Alice Monzani ◽  
...  

BackgroundNeoTapAdvancedSupport (NeoTapAS) is a mobile application, based on a screen tapping method that calculates the heart rate (HR). We aimed to evaluate the accuracy of NeoTapAS in reliably determining HR from auscultation in a high-fidelity simulated newborn resuscitation scenario.MethodsPaediatric residents assessed HR by auscultation plus NeoTapAS in an asphyxiated term infant scenario and orally communicated the estimated HR. An external observer simultaneously documented the actual HR set in the manikin and the communicated HR.ResultsOne hundred and sixty HR measurements were recorded. The agreement between communicated and set HR was good (Cohen’s kappa 0.80, 95% CI 0.72 to 0.87; Bangdiwala’s weighted agreement strength statistic 0.93). Bland-Altman plot showed a mean difference between communicated and set HR values of 1 beats per minute (bpm) (95% agreement limits −9 to 11 bpm).ConclusionNeoTapAS showed a good accuracy in estimating HR and it could be an important resource in settings with limited availability of ECG monitor.


2021 ◽  
Vol 1 (1) ◽  
pp. 53-66
Author(s):  
Viorica Goras-Postica

The article presents the results of a pedagogical study, recently conducted on a group of over 8 thou- sand adolescents on the self-assessment of attitudes towards learning. As technologies have shifted many points of focus in addressing learning as an essential aspect of the educational process, the author intended to analyze the representations of adolescents from the knowledge and information century, administering an online questionnaire consisting of different types of questions. The results revealed diverse and mature perceptions, problems of teacher-student, student-student relations, of the institutional process of organization / culture of learning, but also of its results, as perceived by the main actors of the educational act.


2021 ◽  
Vol 8 ◽  
Author(s):  
Guilherme Falcão Mendes ◽  
Caio Eduardo Gonçalves Reis ◽  
Eduardo Yoshio Nakano ◽  
Renata Puppin Zandonadi

The use of extensive questionnaires has the limitation of filling time bias, related to the ability to focus and accurately respond to many items, justifying the necessity for a brief version. This study aimed to build a brief version of the Caffeine Expectancy Questionnaire in Brazil (B-CaffEQ-BR) composed of 21 items divided into seven factors, with as adequate consistency and reproducibility as the full version. Quantitative procedures using statistical modeling were applied using the CaffEQ-BR (full version) database keeping the Mean Absolute Error (MAE) (based on the full version) &lt;0.5 and Cronbach's α and Intraclass Correlation Coefficient (ICC) ≥0.7. The expert panel (n = 3), in a blind design, evaluated the semantic structuring within the options indicated by previous statistical modeling until the agreement of the expert panel. The participants (n = 62), Brazilian adults who were regular caffeine consumers (175.8 ± 94.4 mg/day), of whom 62.9% were women, 33.1 ± 9.7 years, 24.5 ± 3.8 kg/m2, and 62.9% of whom self-identified as white, were asked to respond twice to the online questionnaire in 48–72 h. The first sample (n = 40) tested interobserver reproducibility with the double application of B-CaffEQ-BR. Another sample (n = 22) answered the CaffEQ-BR (full version) and B-CaffEQ-BR, and the last sample (n = 18) performed the reverse process. The B-CaffEQ-BR presented excellent internal consistency (Cronbach's α ≥ 0.729) and overall reproducibility (ICC ≥ 0.915) for the entire questionnaire and its seven factors. The B-CaffEQ-BR can be a valuable tool in caffeine research with the Brazilian adult population.


Author(s):  
Aparajita Dasgupta ◽  
Foulisa Pyrbot ◽  
Bobby Paul ◽  
Soumit Roy ◽  
Pritam Ghosh ◽  
...  

Introduction: Hypertension is a major risk factor for cardiovascular and cerebrovascular diseases. Thus, regular and accurate measurement of Blood Pressure (BP) is essential for its early diagnosis and follow-up. There is a surge in popularity of digital sphygmomanometer due to its convenience of use and functionality. In contrast, the traditional universally accepted sphygmomanometer is aneroid type, hence there arise a need for comparison of digital and universally accepted Aneroid Sphygmomanometer in terms of agreement and correlation. Aim: To evaluate the agreement and correlation between blood pressure measurement by digital and aneroid sphygmomanometer. Materials and Methods: The clinic based cross-sectional study was conducted in the Out Patient Department (OPD) of Urban Heath Centre, All India Institute of Hygiene and Public Health, Kolkata, West Bengal, India. Adults visiting the OPD on two chosen days of the week, between June 2019 to July 2019 were selected using systematic random sampling. A total of 400 participants were included. Agreement and correlation between BP measurements by digital and aneroid sphygmomanometer was analysed by Cohen’s Kappa, Bland Altman Plot along with sensitivity, specificity and predictive values using Microsoft Excel and Statistical Package for the Social Sciences (SPSS) version 16.0. the p-value <0.05 was considered significant for the statistical test in the analysis. Results: Cohen’s Kappa value (0.59) revealed these two tools had moderate agreement in diagnosing hypertension. Sensitivity and specificity of digital sphygmomanometer taking aneroid sphygmomanometer as gold standard is 86% and 83.1% respectively. The BP readings of these two-tools showed moderate correlation as Intraclass Correlation Coefficient (ICC) for Systolic BP (SBP) and Diastolic BP (DBP) were 0.804 and 0.624, respectively. Bland Altman plot showed gross disagreement of SBP findings and disagreement between DBP findings was also noted. Conclusion: Digital device was found to be less accurate in detecting hypertension. Therefore, more similar research work is solicited to verify the accuracy of the very easy to use, the Digital BP monitor.


Sign in / Sign up

Export Citation Format

Share Document