scholarly journals Study on the Nanosensor Based on a MIM Waveguide with a Stub Coupled with a Horizontal B-Type Cavity

Photonics ◽  
2021 ◽  
Vol 8 (4) ◽  
pp. 125
Author(s):  
Shubin Yan ◽  
Haoran Shi ◽  
Xiaoyu Yang ◽  
Jing Guo ◽  
Wenchang Wu ◽  
...  

Due to their compact size and high sensitivity, plasmonic sensors have become a hot topic in the sensing field. A nanosensor structure, comprising the metal–insulator–metal (MIM) waveguide with a stub and a horizontal B-Type cavity, is designed as a refractive index sensor. The spectral characteristics of proposed structure are analyzed via the finite element method (FEM). The results show that there is a sharp Fano resonance profile, which is excited by a coupling between the MIM waveguide and the horizontal B-Type cavity. The normalized HZ field is affected by the difference value between the outer radii R1 and R2 of the semi-circle of the horizontal B-Type cavity greatly. The influence of every element of the whole system on sensing properties is discussed in depth. The sensitivity of the proposed structure can obtain 1548 nm/RIU (refractive index unit) with a figure of merit of 59. The proposed structure has potential in nanophotonic sensing applications.

Nanomaterials ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 2097
Author(s):  
Yuan-Fong Chou Chau ◽  
Chung-Ting Chou Chao ◽  
Siti Zubaidah Binti Haji Jumat ◽  
Muhammad Raziq Rahimi Kooh ◽  
Roshan Thotagamuge ◽  
...  

This work proposed a multiple mode Fano resonance-based refractive index sensor with high sensitivity that is a rarely investigated structure. The designed device consists of a metal–insulator–metal (MIM) waveguide with two rectangular stubs side-coupled with an elliptical resonator embedded with an air path in the resonator and several metal defects set in the bus waveguide. We systematically studied three types of sensor structures employing the finite element method. Results show that the surface plasmon mode’s splitting is affected by the geometry of the sensor. We found that the transmittance dips and peaks can dramatically change by adding the dual air stubs, and the light–matter interaction can effectively enhance by embedding an air path in the resonator and the metal defects in the bus waveguide. The double air stubs and an air path contribute to the cavity plasmon resonance, and the metal defects facilitate the gap plasmon resonance in the proposed plasmonic sensor, resulting in remarkable characteristics compared with those of plasmonic sensors. The high sensitivity of 2600 nm/RIU and 1200 nm/RIU can simultaneously achieve in mode 1 and mode 2 of the proposed type 3 structure, which considerably raises the sensitivity by 216.67% for mode 1 and 133.33% for mode 2 compared to its regular counterpart, i.e., type 2 structure. The designed sensing structure can detect the material’s refractive index in a wide range of gas, liquids, and biomaterials (e.g., hemoglobin concentration).


2020 ◽  
Vol 12 (1) ◽  
pp. 1 ◽  
Author(s):  
Muhammad Ali ALI Butt ◽  
Nikolay Kazanskiy

We studied the metal-insulator-metal square ring resonator design incorporated with nano-dots that serve to squeeze the surface plasmon wave in the cavity of the ring. The E-field enhances at the boundaries of the nano-dots providing a strong interaction of light with the surrounding medium. As a result, the sensitivity of the resonator is highly enhanced compared to the standard ring resonator design. The best sensitivity of 907 nm/RIU is obtained by placing seven nano-dots of radius 4 nm in all four sides of the ring with a period (ᴧ)= 3r. The proposed design will find applications in biomedical science as highly refractive index sensors. Full Text: PDF References:Z. Han, S. I. Bozhevolnyi. "Radiation guiding with surface plasmon polaritons", Rep. Prog. Phys. 76, 016402 (2013). [CrossRef]N.L. Kazanskiy, S.N. Khonina, M.A. Butt. "Plasmonic sensors based on Metal-insulator-metal waveguides for refractive index sensing applications: A brief review", Physica E 117, 113798 (2020). [CrossRef]D.K. Gramotnev, S.I. Bozhevolnyi. "Plasmonics beyond the diffraction limit", Nat. Photonics 4, 83 (2010). [CrossRef]A.N.Taheri, H. Kaatuzian. "Design and simulation of a nanoscale electro-plasmonic 1 × 2 switch based on asymmetric metal–insulator–metal stub filters", Applied Optics 53, 28 (2014). [CrossRef]P. Neutens, L. Lagae, G. Borghs, P. V. Dorpe. "Plasmon filters and resonators in metal-insulator-metal waveguides", Optics Express 20, 4 (2012). [CrossRef]M.A. Butt, S.N. Khonina, N. L. Kazanskiy. "Metal-insulator-metal nano square ring resonator for gas sensing applications", Waves in Random and complex media [CrossRef]M.A.Butt, S.N.Khonina, N.L.Kazanskiy. "Hybrid plasmonic waveguide-assisted Metal–Insulator–Metal ring resonator for refractive index sensing", Journal of Modern Optics 65, 1135 (2018). [CrossRef]M.A.Butt, S.N. Khonina, N.L. Kazanskiy, "Highly sensitive refractive index sensor based on hybrid plasmonic waveguide microring resonator", Waves in Random and complex media [CrossRef]Y. Fang, M. Sun. "Nanoplasmonic waveguides: towards applications in integrated nanophotonic circuits", Light:Science & Applications 4, e294 (2015). [CrossRef]H. Lu, G.X. Wang, X.M. Liu. "Manipulation of light in MIM plasmonic waveguide systems", Chin Sci Bull [CrossRef]J.N. Anker et al. "Biosensing with plasmonic nanosensors", Nature Materials 7, 442 (2008). [CrossRef]M.A.Butt, S.N. Khonina, N.L. Kazanskiy. Journal of Modern Optics 66, 1038 (2019).[CrossRef]Z.-D. Zhang, H.-Y. Wang, Z.-Y. Zhang. "Fano Resonance in a Gear-Shaped Nanocavity of the Metal–Insulator–Metal Waveguide", Plasmonics 8,797 (2013) [CrossRef]Y. Yu, J. Si, Y. Ning, M. Sun, X. Deng. Opt. Lett. 42, 187 (2017) [CrossRef]B.H.Zhang, L-L. Wang, H-J. Li et al. "Two kinds of double Fano resonances induced by an asymmetric MIM waveguide structure", J. Opt. 18,065001 (2016) [CrossRef]X. Zhao, Z. Zhang, S. Yan. "Tunable Fano Resonance in Asymmetric MIM Waveguide Structure", Sensors 17, 1494 (2017) [CrossRef]J. Zhou et al. "Transmission and refractive index sensing based on Fano resonance in MIM waveguide-coupled trapezoid cavity", AIP Advances 7, 015020 (2017) [CrossRef]V. Perumal, U. Hashim. "Advances in biosensors: Principle, architecture and applications", J. Appl. Biomed. 12, 1 (2014)[CrossRef]H.Gai, J. Wang , Q. Tian, "Modified Debye model parameters of metals applicable for broadband calculations", Appl. Opt. 46 (12), 2229 (2007) [CrossRef]


2020 ◽  
Vol 10 (15) ◽  
pp. 5096
Author(s):  
Hao Su ◽  
Shubin Yan ◽  
Xiaoyu Yang ◽  
Jing Guo ◽  
Jinxi Wang ◽  
...  

In this article, a novel refractive index sensor composed of a metal–insulator–metal (MIM) waveguide with two rectangular stubs coupled with an elliptical ring resonator is proposed, the geometric parameters of which are controlled at a few hundreds of nanometer size. The transmission feature of the structure was studied by the finite element method based on electronic design automation (EDA) software COMSOL Multiphysics 5.4 (Stockholm, Sweden). The rectangular stub resonator can be thought of as a Fabry–Perot (FP) cavity, which can facilitate the Fano resonance. The simulation results reveal that the structure has a symmetric Lorentzian resonance, as well as an ultrasharp and asymmetrical Fano resonance. By adjusting the geometrical parameters, the sensitivity and figure of merit (FOM) of the structure can be optimized flexibly. After adjustments and optimization, the maximum sensitivity can reach up to 1550 nm/RIU (nanometer/Refractive Index Unit) and its FOM is 43.05. This structure presented in this article also has a promising application in highly integrated medical optical sensors to detect the concentration of hemoglobin and monitor body health.


2020 ◽  
Vol 44 (3) ◽  
pp. 295-318 ◽  
Author(s):  
N.L. Kazanskiy ◽  
M.A. Butt ◽  
S.A. Degtyarev ◽  
S.N. Khonina

Optical sensors are widely used in the biomedical, chemical and food industries. They provide high sensitivity to changes in the refractive index of the environment due to a specific distribution of resonances across the field. The sensitivity of the sensor is highly dependent on its material and structure. In this review, we focused on the analysis of silicon waveguides as a promising component for optical sensor miniaturization, and plasmon refractive index sensors without fluorescent labeling. We presented the latest developments of special types of plasmon structures, such as metal-insulator-metal waveguides, and their application in refractive index sensors. We analyzed numerous types of plasmon waveguides, their geometry, materials and manufacturing processes, as well as possible energy losses. A discussion of the spectral characteristics of recently proposed refractive index sensors, with an emphasis on their sensitivity and quality indicators, is an important part of the review.


Electronics ◽  
2021 ◽  
Vol 10 (8) ◽  
pp. 973
Author(s):  
N. L. Kazanskiy ◽  
S. N. Khonina ◽  
M. A. Butt ◽  
A. Kaźmierczak ◽  
R. Piramidowicz

Optical sensors for biomedical applications have gained prominence in recent decades due to their compact size, high sensitivity, reliability, portability, and low cost. In this review, we summarized and discussed a few selected techniques and corresponding technological platforms enabling the manufacturing of optical biomedical sensors of different types. We discussed integrated optical biosensors, vertical grating couplers, plasmonic sensors, surface plasmon resonance optical fiber biosensors, and metasurface biosensors, Photonic crystal-based biosensors, thin metal films biosensors, and fiber Bragg grating biosensors as the most representative cases. All of these might enable the identification of symptoms of deadly illnesses in their early stages; thus, potentially saving a patient’s life. The aim of this paper was not to render a definitive judgment in favor of one sensor technology over another. We presented the pros and cons of all the major sensor systems enabling the readers to choose the solution tailored to their needs and demands.


2020 ◽  
Vol 12 (3) ◽  
pp. 82
Author(s):  
Muhammad Ali Butt

In this paper, miniaturized design of a plasmonic Bragg grating filter is investigated via the finite element method (FEM). The filter is based on a plasmonic metal-insulator-metal waveguide deposited on a quartz substrate. The corrugated Bragg grating designed for near-infrared wavelength range is structured on both sides of the waveguide. The spectral characteristics of the filter are studied by varying the geometric parameters of the filter design. As a result, the maximum ER and bandwidth of 36.2 dB and 173 nm is obtained at λBragg=976 nm with a filter footprint of as small as 1.0 x 8.75 µm2, respectively. The ER and bandwidth can be further improved by increasing the number of grating periods and the strength of the grating, respectively. Moreover, the Bragg grating structure is quite receptive to the refractive index of the medium. These features allow the employment of materials such as polymers in the metal-insulator-metal waveguide which can be externally tuned or it can be used for refractive index sensing applications. The sensitivity of the proposed Bragg grating structure can offer a sensitivity of 950 nm/RIU. We believe that the study presented in this paper provides a guideline for the realization of small footprint plasmonic Bragg grating structures which can be employed in filter and refractive index sensing applications. Full Text: PDF ReferencesJ. W. Field et al., "Miniaturised, Planar, Integrated Bragg Grating Spectrometer", 2019 Conference on Lasers and Electro-Optics Europe and European Quantum Electronics Conference (CLEO/Europe-EQEC), Munich, Germany, 2019, CrossRef L. Cheng, S. Mao, Z. Li, Y. Han, H.Y. Fu, "Grating Couplers on Silicon Photonics: Design Principles, Emerging Trends and Practical Issues", Micromachines, 11, 666 (2020). CrossRef J. Missinne, N. T. Beneitez, M-A. Mattelin, A. Lamberti, G. Luyckx, W. V. Paepegem, G. V. Steenberge, "Bragg-Grating-Based Photonic Strain and Temperature Sensor Foils Realized Using Imprinting and Operating at Very Near Infrared Wavelengths", Sensors, 18, 2717 (2018). CrossRef M. A. Butt, S.N. Khonina, N.L. Kazanskiy, "Numerical analysis of a miniaturized design of a Fabry–Perot resonator based on silicon strip and slot waveguides for bio-sensing applications", Journal of Modern Optics, 66, 1172-1178 (2019). CrossRef H. Qiu, J. Jiang, P. Yu, T. Dai, J. Yang, H. Yu, X. Jiang, "Silicon band-rejection and band-pass filter based on asymmetric Bragg sidewall gratings in a multimode waveguide", Optics Letters, 41, 2450 (2016). CrossRef M. A. Butt, S.N. Khonina, N.L. Kazanskiy, "Optical elements based on silicon photonics", Computer Optics, 43, 1079-1083 (2019). CrossRef N. L. Kazanskiy, S.N. Khonina, M.A. Butt, "Plasmonic sensors based on Metal-insulator-metal waveguides for refractive index sensing applications: A brief review", Physica E, 117, 113798 (2020). CrossRef L. Lu et al, "Mode-Selective Hybrid Plasmonic Bragg Grating Reflector", IEEE Photonics Technology Letters, 22, 1765-1767 (2012). CrossRef R. Negahdari, E. Rafiee, F. Emami, "Design and simulation of a novel nano-plasmonic split-ring resonator filter", Journal of Electromagnetic Waves and Applications, 32, 1925-1938 (2018). CrossRef M. Janfaza, M. A. Mansouri-Birjandi, "Tunable plasmonic band-pass filter based on Fabry–Perot graphene nanoribbons", Applied Physics B, 123, 262 (2017). CrossRef C. Wu, G. Song, L. Yu, J.H. Xiao, "Tunable narrow band filter based on a surface plasmon polaritons Bragg grating with a metal–insulator–metal waveguide", Journal of Modern Optics, 60, 1217-1222 (2013). CrossRef J. Zhu, G. Wang, "Sense high refractive index sensitivity with bragg grating and MIM nanocavity", Results in Physics, 15, 102763 (2019). CrossRef Y. Binfeng, H. Guohua, C. Yiping, "Design of a compact and high sensitive refractive index sensor base on metal-insulator-metal plasmonic Bragg grating", Optics Express, 22, 28662-28670 (2014). CrossRef A.D. Simard, Y. Painchaud, S. Larochelle, "Small-footprint integrated Bragg gratings in SOI spiral waveguides", International Quantum Electronics Conference Lasers and Electro-Optics Europe, IEEE, Munich, Germany (2013). CrossRef C. Klitis, G. Cantarella, M. J. Strain, M. Sorel, "High-extinction-ratio TE/TM selective Bragg grating filters on silicon-on-insulator", Optics Letters, 42, 3040 (2017). CrossRef J. Ctyroky et al., "Design of narrowband Bragg spectral filters in subwavelength grating metamaterial waveguides", Optics Express, 26, 179 (2018). CrossRef M.A. Butt, N.L. Kazanskiy, S.N. Khonina, "Hybrid plasmonic waveguide race-track µ-ring resonator: Analysis of dielectric and hybrid mode for refractive index sensing applications", Laser Phys., 30, 016202 (2020). CrossRef M. A. Butt, N.L. Kazanskiy, S.N. Khonina, "Label-free detection of ambient refractive index based on plasmonic Bragg gratings embedded resonator cavity sensor", Journal of Modern Optics, 66, 1920-1925 (2019). CrossRef N. L. Kazanskiy, M.A. Butt, Photonics Letters of Poland, 12, 1-3 (2020). CrossRef Z. Guo, K. Wen, Q. Hu, W. Lai, J. Lin, Y. Fang, "Plasmonic Multichannel Refractive Index Sensor Based on Subwavelength Tangent-Ring Metal–Insulator–Metal Waveguide", Sensors, 18, 1348 (2018). CrossRef


2022 ◽  
Author(s):  
Haowen Chen ◽  
Yunping Qi ◽  
Jinghui Ding ◽  
Yujiao Yuan ◽  
Zhenting Tian ◽  
...  

Abstract A plasmonic resonator system consisting of a metal-insulator-metal waveguide and a Q-shaped resonant cavity is proposed in this paper. The transmission properties of surface plasmon polaritons in this structure are investigated using the finite difference in time domain (FDTD) method, and the simulation results contain two resonant dips. And the physical mechanism is studied by the multimode interference coupled mode theory (MICMT), the theoretical results are in highly consistent with the simulation results. Furthermore, the parameters of the Q-shaped cavity can be controlled to adjust two dips respectively. The refractive index sensor with a sensitivity of 1578nm/RIU and figure of merit (FOM) of 175, performs better than most of the similar structures. Therefore, the results of the study are instructive for the design and application of high sensitivity nanoscale refractive index sensors.


Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3181 ◽  
Author(s):  
Kunhua Wen ◽  
Li Chen ◽  
Jinyun Zhou ◽  
Liang Lei ◽  
Yihong Fang

In this paper, multiple Fano resonances preferred in the refractive index sensing area are achieved based on sub-wavelength metal-insulator-metal (MIM) waveguides. Two slot cavities, which are placed between or above the MIM waveguides, can support the bright modes or the dark modes, respectively. Owing to the mode interferences, dual Fano resonances with obvious asymmetrical spectral responses are achieved. High sensitivity and high figure of merit are investigated by using the finite-difference time-domain (FDTD) method. In view of the development of chip-scale integrated photonics, two extra slot cavities are successively added to the structure, and consequently, three and four ultra-sharp Fano peaks with considerable performances are obtained, respectively. It is believed that this proposed structure can find important applications in the on-chip optical sensing and optical communication areas.


2020 ◽  
Vol 34 (16) ◽  
pp. 2050173
Author(s):  
Yihong Fang ◽  
Kunhua Wen ◽  
Zhengfeng Li ◽  
Bingye Wu ◽  
Zicong Guo

A multi-channel Fano resonant structure is proposed and analyzed based on subwavelength metal–insulator–metal (MIM) waveguides. First, two MIM output ports associated with specific side-coupled cavities are designed to locate at the center and quarter positions of an end-coupled cavity, respectively. Since the interference between the dark and bright modes, dual-channel Fano resonances with asymmetrical lines shapes are obtained at both ports, respectively. High sensitivity and figure of merits are investigated. Besides, phase shifts are also investigated leading to positive and negative group delays available at the Fano peaks and dips, respectively. Likewise, two extra output ports with identical resonant cavities are placed on the other side of the end-coupled cavity. In this case, four-channel Fano resonances with considerable performances are obtained. The proposed structure is analyzed by the coupled mode theory and the finite difference time domain method. It is believed this device can be used as a chip-scale refractive index sensor and optical filter.


Sign in / Sign up

Export Citation Format

Share Document