scholarly journals Influence of Temperature Variation on the Vibrational Characteristics of Fused Silica Cylindrical Resonators for Coriolis Vibratory Gyroscopes

Sensors ◽  
2020 ◽  
Vol 20 (4) ◽  
pp. 1032
Author(s):  
Pengbo Xiao ◽  
Zhinan Qiu ◽  
Yiming Luo ◽  
Yao Pan ◽  
Tianliang Qu ◽  
...  

The fused silica cylindrical resonator is a type of axisymmetric resonator that can be used for Coriolis vibratory gyroscopes. Although the resonant frequency, frequency mismatch, and Q factor are natural properties of the resonator, they can change with temperature. Therefore, the temperature drift severely limits the detection accuracy and bias stability of the gyroscope. In this paper, the influence of temperature variation on the vibrational characteristics of fused silica cylindrical resonators was investigated. Experiments were performed on a fused silica cylindrical resonator coated with Cr/Au films. It was shown that at the temperature range from 253.15 K to 353.15 K, the resonant frequency linearly increased with temperature, the frequency mismatch remained unchanged, and the Q factor gradually increased till about 333.15 K, when it began to decrease. Meanwhile, the change of thermoelastic damping with temperature may dominate the variation of Q factor at the temperature range from 253.15 K to 353.15 K. This phenomenon was theoretically analyzed and the variation trends of results were consistent with the theoretical analysis. This study indicates that, for the fused silica cylindrical resonator, to discover the influence of temperature variation on the resonant frequency, frequency mismatch, and Q factor, there are certain rules to follow and repeat. The relationship between temperature and frequency can be established, which provides the feasibility of using self-calibration based on temperature characteristics of the resonator for temperature drift compensations. Additionally, there is an optimum temperature that may improve the performance of the Coriolis vibratory gyroscope with the fused silica cylindrical resonator.

Sensors ◽  
2020 ◽  
Vol 20 (1) ◽  
pp. 295 ◽  
Author(s):  
Pengbo Xiao ◽  
Zhinan Qiu ◽  
Yao Pan ◽  
Shaoliang Li ◽  
Tianliang Qu ◽  
...  

The Coriolis Vibratory Gyroscopes are a type of sensors that measure angular velocities through the Coriolis effect. The resonator is the critical component of the CVGs, the vibrational characteristics of which, including the resonant frequency, frequency mismatch, Q factor, and Q factor asymmetry, have a great influence on the performance of CVG. The frequency mismatch and Q factor of the resonator, in particular, directly determine the precision and drift characteristics of the gyroscope. Although the frequency mismatch and Q factor are natural properties of the resonator, they can change with external conditions, such as temperature, pressure, and external forces. In this paper, the influence of electrostatic forces on the vibrational characteristics of the fused silica cylindrical resonator is investigated. Experiments were performed on a fused silica cylindrical resonator coated with Cr/Au films. It was shown that the resonant frequency, frequency mismatch, and the decay time slightly decreased with electrostatic forces, while the decay time split increased. Lower capacitive gaps and larger applied voltages resulted in lower frequency mismatch and lower decay time. This phenomenon was theoretically analyzed, and the variation trends of results were consistent with the theoretical analysis. This study indicates that, for fused silica cylindrical resonator with electrostatic transduction, the electrostatic influence on the Q factor and frequency, although small, should be considered when designing the capacitive gap and choosing bias voltages.


Sensors ◽  
2019 ◽  
Vol 19 (13) ◽  
pp. 2928 ◽  
Author(s):  
Zhinan Qiu ◽  
Tianliang Qu ◽  
Yao Pan ◽  
Yonglei Jia ◽  
Zhenfang Fan ◽  
...  

Fused silica cylindrical resonant gyroscope (CRG) is a novel high-precision solid-wave gyroscope, whose performance is primarily determined by the cylindrical resonator’s frequency split and quality factor (Q factor). The laser Doppler vibrometer (LDV) is extensively used to measure the dynamic behavior of fused silica cylindrical resonators. An electrical method was proposed to characterize the dynamic behavior of the cylindrical resonator to enhance the measurement efficiency and decrease the equipment cost. With the data acquisition system and the designed signal analysis program based on LabVIEW software, the dynamic behavior of the fused silica cylindrical resonator can be analyzed automatically and quickly. We compared all the electrical measurement results with the optical detection by LDV, demonstrating that the fast Fourier transform (FFT) result of the resonant frequency measured by the electrical method was 0.12 Hz higher than that with the optical method. Thus, the frequency split measured by the electrical and optical methods was the same in 0.18 Hz, and the measurement of the Q factor was basically the same in 730,000. We conducted all measurements under the same operation condition, and the optical method was used as a reference, demonstrating that the electrical method could characterize the dynamic behavior of the fused silica cylindrical resonator and enhance the measurement efficiency.


Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6003
Author(s):  
Libin Zeng ◽  
Yiming Luo ◽  
Yao Pan ◽  
Yonglei Jia ◽  
Jianping Liu ◽  
...  

The cylindrical resonator is the core component of cylindrical resonator gyroscopes (CRGs). The quality factor (Q factor) of the resonator is one crucial parameter that determines the performance of the gyroscope. In this paper, the finite element method is used to theoretically investigate the influence of the thermoelastic dissipation (TED) of the cylindrical resonator. The improved structure of a fused silica cylindrical resonator is then demonstrated. Compared with the traditional structure, the thermoelastic Q (QTED) of the resonator is increased by 122%. In addition, the Q factor of the improved cylindrical resonator is measured, and results illustrate that, after annealing and chemical etching, the Q factor of the resonator is significantly higher than that of the cylindrical resonators reported previously. The Q factor of the cylindrical resonator in this paper reaches 5.86 million, which is the highest value for a cylindrical resonator to date.


Micromachines ◽  
2021 ◽  
Vol 12 (9) ◽  
pp. 1052
Author(s):  
Libin Zeng ◽  
Yunfeng Tao ◽  
Yao Pan ◽  
Jianping Liu ◽  
Kaiyong Yang ◽  
...  

For the axisymmetric shell resonator gyroscopes, the quality factor (Q factor) of the resonator is one of the core parameters limiting their performances. Surface loss is one of the dominating losses, which is related to the subsurface damage (SSD) that is influenced by the grinding parameters. This paper experimentally studies the surface roughness and Q factor variation of six resonators ground by three different grinding speeds. The results suggest that the removal of the SSD cannot improve the Q factor continuously, and the variation of surface roughness is not the dominant reason to affect the Q factor. The measurement results indicate that an appropriate increase in the grinding speed can significantly improve the surface quality and Q factor. This study also demonstrates that a 20 million Q factor for fused silica cylindrical resonators is achievable using appropriate manufacturing processes combined with post-processing etching, which offers possibilities for developing high-precision and low-cost cylindrical resonator gyroscopes.


2004 ◽  
Vol 14 (11) ◽  
pp. 1530-1536 ◽  
Author(s):  
Chihwan Jeong ◽  
Seonho Seok ◽  
Byeungleul Lee ◽  
Hyeonched Kim ◽  
Kukjin Chun

1982 ◽  
Vol IM-31 (1) ◽  
pp. 18-21 ◽  
Author(s):  
Rajani K. Pandrangi ◽  
Stanislaw S. Stuchly ◽  
Mariusz Barski

2018 ◽  
Vol 11 (4) ◽  
pp. 604-609
Author(s):  
蒋丽媛 JIANG Li-yuan ◽  
刘定权 LIU Ding-quan ◽  
马冲 MA Chong ◽  
蔡清元 CAI Qing-yuan ◽  
高凌山 GAO Ling-shan

Sensors ◽  
2019 ◽  
Vol 19 (3) ◽  
pp. 658 ◽  
Author(s):  
Víctor Ruiz-Díez ◽  
Javier Toledo ◽  
Jorge Hernando-García ◽  
Abdallah Ababneh ◽  
Helmut Seidel ◽  
...  

Cantilever resonators based on the roof tile-shaped modes have recently demonstrated their suitability for liquid media monitoring applications. The early studies have shown that certain combinations of dimensions and order of the mode can maximize the Q-factor, what might suggest a competition between two mechanisms of losses with different geometrical dependence. To provide more insight, a comprehensive study of the Q-factor and the resonant frequency of these modes in microcantilever resonators with lengths and widths between 250 and 3000 µm and thicknesses between 10 and 60 µm is presented. These modes can be efficiently excited by a thin piezoelectric AlN film and a properly designed top electrode layout. The electrical and optical characterization of the resonators are performed in liquid media and then their performance is evaluated in terms of quality factor and resonant frequency. A quality factor as high as 140 was measured in isopropanol for a 1000 × 900 × 10 µm3 cantilever oscillating in the 11th order roof tile-shaped mode at 4 MHz; density and viscosity resolutions of 10−6 g/mL and 10−4 mPa·s, respectively are estimated for a geometrically optimized cantilever resonating below 1 MHz.


2021 ◽  
Vol 99 (1) ◽  
pp. 18-23
Author(s):  
Charlie Joe Croxford ◽  
Rajpreet Kaur ◽  
Kultar Singh ◽  
Mandeep Singh Bakshi

Stable colloidal zein nanoparticles (NPs) were synthesized by using controlled precipitation method. They were made fluorescence active by incorporating a small amount of fluorescence quinolinium surfactant. The incorporation of fluorescence surfactant provided both the colloidal stability and the fluorescence ability to determine the phase transition in zein NPs under the effect of temperature variation. Maintaining colloidal stability under the effect of temperature variation is an essential aspect of zein NPs applicability as a source of vegetarian protein supplement in different food suspensions. Different techniques such as fluorescence, DLS size, zeta potential, and FTIR measurements were applied to determine the influence of temperature on the colloidal stability of zein NPs. Zein NPs undergo phase transition well above room temperature while maintaining their size in nanometer range, and the phase transition temperature decreased with the amount of zein used in the synthesis of zein NPs. The results highlighted the potential use of zein NPs as a vegetarian supplement protein in different food products.


Sign in / Sign up

Export Citation Format

Share Document