scholarly journals Quantitative X-ray Channel-Cut Crystal Diffraction Wavefront Metrology Using the Speckle Scanning Technique

Sensors ◽  
2020 ◽  
Vol 20 (22) ◽  
pp. 6660
Author(s):  
Lian Xue ◽  
Hongxin Luo ◽  
Qianshun Diao ◽  
Fugui Yang ◽  
Jie Wang ◽  
...  

A speckle-based method for the X-ray crystal diffraction wavefront measurement is implemented, and the slope errors of channel-cut crystals with different surface characteristics are measured. The method uses a speckle scanning technique generated by a scattering membrane translated using a piezo motor to infer the deflection of X-rays from the crystals. The method provides a high angular sensitivity of the channel-cut crystal slopes in both the tangential and sagittal directions. The experimental results show that the slope error of different cutting and etching processes ranges from 0.25 to 2.98 μrad. Furthermore, the results of wavefront deformation are brought into the beamline for simulation. This method opens up possibilities for new high-resolution applications for X-ray crystal diffraction wavefront measurement and provides feedback to crystal manufacturers to improve channel-cut fabrication.

2017 ◽  
Vol 890 ◽  
pp. 223-226 ◽  
Author(s):  
Rıdvan Durak ◽  
Ferdi Akman ◽  
Abdulhalik Karabulut

The Ll, Lα and Lβ X-ray production cross sections for Pr, Nd, Sm, Eu, Gd and Tb elements were determined using a reflection geometry. The excitation was performed with a 241Am radioactive annular source and the L X-rays emitted from targets were counted with a high-resolution Si (Li) detector. The experimental values were compared with other available experimental results and theoretical data. An agreement is observed between the measured and other experimental results or theoretical data.


2014 ◽  
Vol 92 (11) ◽  
pp. 1489-1493 ◽  
Author(s):  
P.V. Sreevidya ◽  
S.B. Gudennavar ◽  
Daisy Joseph ◽  
S.G. Bubbly

K shell X-rays of barium and thallium following internal conversion decay in Cs137 and Hg203, respectively, were detected using a Si(Li) X-ray detector coupled to PC-based 8k multichannel analyser employing the method suggested earlier by our group. The K shell X-ray intensity ratios and vacancy transfer probabilities for thallium and barium were calculated. The obtained results are compared with theoretical, semiempirical, and others’ experimental results obtained via photoionization as well as decay processes. The effects of beta decay and internal conversion on X-ray emission probabilities are discussed.


1998 ◽  
Vol 5 (3) ◽  
pp. 515-517 ◽  
Author(s):  
M. Frank ◽  
C. A. Mears ◽  
S. E. Labov ◽  
L. J. Hiller ◽  
J. B. le Grand ◽  
...  

Experimental results are presented obtained with a cryogenically cooled high-resolution X-ray spectrometer based on a 141 × 141 µm Nb-Al-Al2O3-Al-Nb superconducting tunnel junction (STJ) detector in an SR-XRF demonstration experiment. STJ detectors can operate at count rates approaching those of semiconductor detectors while still providing a significantly better energy resolution for soft X-rays. By measuring fluorescence X-rays from samples containing transition metals and low-Z elements, an FWHM energy resolution of 6–15 eV for X-rays in the energy range 180–1100 eV has been obtained. The results show that, in the near future, STJ detectors may prove very useful in XRF and microanalysis applications.


2007 ◽  
Vol 130 ◽  
pp. 7-14 ◽  
Author(s):  
Andrew N. Fitch

The highly-collimated, intense X-rays produced by a synchrotron radiation source can be harnessed to build high-resolution powder diffraction instruments with a wide variety of applications. The general advantages of using synchrotron radiation for powder diffraction are discussed and illustrated with reference to the structural characterisation of crystalline materials, atomic PDF analysis, in-situ and high-throughput studies where the structure is evolving between successive scans, and the measurement of residual strain in engineering components.


1991 ◽  
Vol 01 (03) ◽  
pp. 251-258 ◽  
Author(s):  
M. TERASAWA

K, L, and M X-rays in the wavelengths between 6Å and 130Å generated by the bombardment of 200 keV protons and other heavy ions were measured by means of a wavelength dispersive Bragg’s spectrometer. The X-ray peak intensity was fairly high in general, while the background was very low. The technique was favorably applied to a practical analysis of several light elements (Be, B, C, N, O, and F). Use of moderate-energy heavy ions considering the wavelength selectivity in X-ray generation was effective for the element analysis. The high-resolution spectrometry in the analytical application of ion-induced X-ray generation was found to be useful for the study of fine electronic structure, e.g. satellite and hypersatellite X-ray study, and of the chemical state of materials.


2016 ◽  
Vol 23 (6) ◽  
pp. 1462-1473 ◽  
Author(s):  
Sebastian Cartier ◽  
Matias Kagias ◽  
Anna Bergamaschi ◽  
Zhentian Wang ◽  
Roberto Dinapoli ◽  
...  

MÖNCH is a 25 µm-pitch charge-integrating detector aimed at exploring the limits of current hybrid silicon detector technology. The small pixel size makes it ideal for high-resolution imaging. With an electronic noise of about 110 eV r.m.s., it opens new perspectives for many synchrotron applications where currently the detector is the limiting factor,e.g.inelastic X-ray scattering, Laue diffraction and soft X-ray or high-resolution color imaging. Due to the small pixel pitch, the charge cloud generated by absorbed X-rays is shared between neighboring pixels for most of the photons. Therefore, at low photon fluxes, interpolation algorithms can be applied to determine the absorption position of each photon with a resolution of the order of 1 µm. In this work, the characterization results of one of the MÖNCH prototypes are presented under low-flux conditions. A custom interpolation algorithm is described and applied to the data to obtain high-resolution images. Images obtained in grating interferometry experiments without the use of the absorption grating G2are shown and discussed. Perspectives for the future developments of the MÖNCH detector are also presented.


2021 ◽  
Author(s):  
Md Inzamam Ul Haque ◽  
Abhishek K Dubey ◽  
Jacob D Hinkle

Deep learning models have received much attention lately for their ability to achieve expert-level performance on the accurate automated analysis of chest X-rays. Although publicly available chest X-ray datasets include high resolution images, most models are trained on reduced size images due to limitations on GPU memory and training time. As compute capability continues to advance, it will become feasible to train large convolutional neural networks on high-resolution images. This study is based on the publicly available MIMIC-CXR-JPG dataset, comprising 377,110 high resolution chest X-ray images, and provided with 14 labels to the corresponding free-text radiology reports. We find, interestingly, that tasks that require a large receptive field are better suited to downscaled input images, and we verify this qualitatively by inspecting effective receptive fields and class activation maps of trained models. Finally, we show that stacking an ensemble across resolutions outperforms each individual learner at all input resolutions while providing interpretable scale weights, suggesting that multi-scale features are crucially important to information extraction from high-resolution chest X-rays.


1984 ◽  
Vol 17 (5) ◽  
pp. 337-343 ◽  
Author(s):  
O. Yoda

A high-resolution small-angle X-ray scattering camera has been built, which has the following features. (i) The point collimation optics employed allows the scattering cross section of the sample to be directly measured without corrections for desmearing. (ii) A small-angle resolution better than 0.5 mrad is achieved with a camera length of 1.6 m. (iii) A high photon flux of 0.9 photons μs−1 is obtained on the sample with the rotating-anode X-ray generator operated at 40 kV–30 mA. (iv) Incident X-rays are monochromated by a bent quartz crystal, which makes the determination of the incident X-ray intensity simple and unambiguous. (v) By rotation of the position-sensitive proportional counter around the direct beam, anisotropic scattering patterns can be observed without adjusting the sample. Details of the design and performance are presented with some applications.


1990 ◽  
Vol 23 (5) ◽  
pp. 351-354
Author(s):  
D. Hohlwein ◽  
J. D. Axe

A photographic Weissenberg camera has been constructed which can be mounted on the 2θ arm of a four-circle diffractometer. At a distance of 0.5 m from the sample the 2θ resolution for a 100 μm crystal is 0.2 mrad (0.01°), allowing a high-resolution mapping of reciprocal space at a synchrotron source in an efficient way. As sample experimental results, a study is presented of the streak system around the 111 reflection of a perfect germanium crystal and the detection of a minute phase transformation in a single-powder grain of a high-Tc superconductor.


1981 ◽  
Vol 34 (2) ◽  
pp. 155 ◽  
Author(s):  
HJ Hay ◽  
LF Pender ◽  
PB Treacy

With a high-resolution Si(Li) X-ray detector, characteristic K X rays have been detected with targets of Cr, Fe, Cu, Ge and Se ombarded by 100 MeV Cu ions, equilibrated by passing through carbon. Cross sections for X-ray production, target-to-projectile vacancy-sharing ratios and K, to K, ratios were measured and compared with predictions of molecular-coupling theories. The results show little greement with existing models based on rotational coupling in molecular-orbital states.


Sign in / Sign up

Export Citation Format

Share Document