scholarly journals Electrochemical Immunosensor for the Early Detection of Rheumatoid Arthritis Biomarker: Anti-Cyclic Citrullinated Peptide Antibody in Human Serum Based on Avidin-Biotin System

Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 124
Author(s):  
Somasekhar R. Chinnadayyala ◽  
Sungbo Cho

Rheumatoid arthritis (RA) is a chronic autoimmune disease that produces a progressive inflammatory response that leads to severe pain, swelling, and stiffness in the joints of hands and feet, followed by irreversible damage of the joints. The authors developed a miniaturized, label-free electrochemical impedimetric immunosensor for the sensitive and direct detection of arthritis Anti-CCP-ab biomarker. An interdigitated-chain-shaped microelectrode array (ICE) was fabricated by taking the advantage of microelectromechanical systems. The fabricated ICE was modified with a self-assembled monolayer (SAM) of Mercaptohexanoic acid (MHA) for immobilization of the synthetic peptide bio-receptor (B-CCP). The B-CCP was attached onto the surface of SAM modified ICE through a strong avidin-biotin bio-recognition system. The modified ICE surface with the SAM and bio-molecules (Avidin, B-CCP, Anti-CCP-ab and BSA) was morphologically and electrochemically characterized. The change in the sensor signal upon analyte binding on the electrode surface was probed through the electrochemical impedance spectroscopy (EIS) property of charge-transfer resistance (Rct) of the modified electrodes. EIS measurements were target specific and the sensor response was linearly increased with step wise increase in target analyte (Anti-CCP-ab) concentrations. The developed sensor showed a linear range for the addition of Anti-CCP-ab between 1 IU mL−1 → 800 IU mL−1 in phosphate buffered saline (PBS) and Human serum (HS), respectively. The sensor showed a limit of detection of 0.60 IU mL−1 and 0.82 IU mL−1 in the PBS and HS, respectively. The develop bio-electrode showed a good reproducibility (relative standard deviation (RSD), 1.52%), selectivity and stability (1.5% lost at the end of 20th day) with an acceptable recovery rate (98.0% → 101.18%) and % RSD’s for the detection of Anti-CCP-ab in spiked HS samples.

Biomedicines ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 10
Author(s):  
Hien T. Ngoc Le ◽  
Sungbo Cho

The development of an electrochemical biosensor for the detection of phosphorylated-tau threonine 231 (p-tau231), a biomarker of Alzheimer’s disease (AD), has yet to be achieved. Therefore, in this study, we developed a simple, small size, cheap, and sensitive electrochemical biosensor based on an interdigitated wave-shaped electrode via an activated self-assembled monolayer to preserve a specific anti–p-tau231 antibody (IWE/SAM/EDC-NHS/anti–p-tau231). Detection of p-tau231 in human serum (HS) using the biosensor was undertaken using electrochemical impedance spectroscopy (EIS). The change in charge-transfer resistance (Rct) in the EIS analysis of the biosensor indicated the detection of p-tau231 in HS within a wide linear range of detection (10−4–101 ng mL−1), and a low limit of detection (140 pg mL−1). This lower limit is less than the detection level of p-tau231 in cerebrospinal fluid (CSF) (700 pg mL−1) of AD patients and the level of CSF p-tau231 of patients with mild cognitive impairment (501 pg mL−1), demonstrating the possibility of using the biosensor in detection of p-tau231 at early stage AD. A high binding affinity and low dissociation constant (Kd) between anti–p-tau231 and p-tau231 in HS was demonstrated by using a biosensor and Kd was 7.6 pM, demonstrating the high specific detection of p-tau231 by the biosensor. The good selectivity of the biosensor for the detection of p-tau231 with differential analytes was also examined in this study.


2020 ◽  
Vol 16 ◽  
Author(s):  
Nadereh Rahbar ◽  
Fatemeh Ahmadi ◽  
Zahra Ramezani ◽  
Masoumeh Nourani

Background: Sample preparation is one of the most challenging phases in pharmaceutical analysis, especially in biological matrices, affecting the whole analytical methodology. Objective: In this study, a new Ca(II)/Cu(II)/alginate/CuO nanoparticles hydrogel fiber (CCACHF) was synthesized through a simple, green procedure and applied for fiber micro solid phase extraction (FMSPE) of diazepam (DIZ) and oxazepam (OXZ) as model drugs prior to high-performance liquid chromatography-UV detection (HPLC-UV). Methods: Composition and morphology of the prepared fiber were characterized and the effect of main parameters on the fiber fabrication and extraction efficiency have been studied and optimized. Results: In optimal conditions, calibration curves were linear ranging between 0.1–500 µg L−1 with regression coefficients of 0.9938 and 0.9968. Limit of detection (LOD) (S/N=3) and limit of quantification (LOQ) (S/N=10) of the technique for DIZ and OXZ were 0.03 to 0.1 µg L−1. Within-day and between-day relative standard deviations (RSDs) for DIZ and OXZ were 6.0–12.5% and 3.3–9.4%, respectively. Conclusion: The fabricated adsorbent has been substantially employed to extraction of selected benzo-diazepines (BZDs) from human serum real specimens and the obtained recoveries were also satisfactory (82.1-109.7%).


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 1929
Author(s):  
Alexander Rodríguez ◽  
Francisco Burgos-Flórez ◽  
José D. Posada ◽  
Eliana Cervera ◽  
Valtencir Zucolotto ◽  
...  

Neuronal damage secondary to traumatic brain injury (TBI) is a rapidly evolving condition, which requires therapeutic decisions based on the timely identification of clinical deterioration. Changes in S100B biomarker levels are associated with TBI severity and patient outcome. The S100B quantification is often difficult since standard immunoassays are time-consuming, costly, and require extensive expertise. A zero-length cross-linking approach on a cysteamine self-assembled monolayer (SAM) was performed to immobilize anti-S100B monoclonal antibodies onto both planar (AuEs) and interdigitated (AuIDEs) gold electrodes via carbonyl-bond. Surface characterization was performed by atomic force microscopy (AFM) and specular-reflectance FTIR for each functionalization step. Biosensor response was studied using the change in charge-transfer resistance (Rct) from electrochemical impedance spectroscopy (EIS) in potassium ferrocyanide, with [S100B] ranging 10–1000 pg/mL. A single-frequency analysis for capacitances was also performed in AuIDEs. Full factorial designs were applied to assess biosensor sensitivity, specificity, and limit-of-detection (LOD). Higher Rct values were found with increased S100B concentration in both platforms. LODs were 18 pg/mL(AuES) and 6 pg/mL(AuIDEs). AuIDEs provide a simpler manufacturing protocol, with reduced fabrication time and possibly costs, simpler electrochemical response analysis, and could be used for single-frequency analysis for monitoring capacitance changes related to S100B levels.


2011 ◽  
Vol 76 (3) ◽  
pp. 159-176 ◽  
Author(s):  
Ibrahim Hüdai Taşdemir ◽  
Orhan Çakirer ◽  
Nevin Erk ◽  
Esma Kiliç

Electrochemical properties and diffusion-adsorption behavior of risperidone (RPN), an antiphyscotic drug, on hanging mercury drop electrode (HMDE) were carried out in Britton–Robinson (BR) buffer. Some electrochemical parameters such as diffusion coefficient, number of transferred electrons and proton participated to its reduction mechanism and surface coverage coefficient were calculated from the results of cyclic voltammetry, square-wave voltammetry and constant potential electrolysis. RPN was found to be reduced with single two-electron/two-proton quasi-reversible mechanism controlled mainly by adsorption with some diffusion contribution at the potential about –1.58 V (vs Ag|AgCl electrode). Experimental parameters were optimized to develop a new, accurate, rapid, selective and simple square-wave cathodic adsorptive stripping voltammetric (SWCAdSV) method for direct determination of RPN in pharmaceutical dosage forms, spiked human urine and human serum samples without time-consuming steps prior to drug assay. This method was based on the relation between the peak current and the concentration of RPN and it was recognized that peak current of reduction wave linearly changes with the concentration of RPN in the concentration range of 1.5–150 nM, when optimum preconcentration potential –0.65 V and optimum preconcentration time 60 s were applied. In this method, limit of detection (LOD) was found as 5.18 nM (2.12 ppb). The method was successfully applied to determine the RPN content of commercial pharmaceutical preparations, spiked human serum and spiked human urine. The method was found to be highly accurate and precise, having a relative standard deviation of less than 4.80% for all applications.


2003 ◽  
Vol 68 (8-9) ◽  
pp. 691-698 ◽  
Author(s):  
Milena Jelikic-Stankov ◽  
Predrag Djurdjevic ◽  
Dejan Stankov

In this work a new enzymatic method for the determination of uric acid in human serum has been developed. The method is based on the oxidative coupling reaction between the N-methyl-N-(4-aminophenyl)-3-methoxyaniline (NCP) reagent and the hydrogen ? donor reagent N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (TOOS), in the system involving three enzymes: uricase, peroxidase and ascorbate oxidase. Using this method uric acid could be determined in concentrations up to 1.428 mmol/L, with a relative standard deviation of up to 1.8 %. The effect of the medium pH and the NCP concentration on the linearity of the chromogen absorbance versus the uric acid concentration curve was investigated. The influence of the uricase activity on the maximum rate of uric acid oxidation was also examined. The use of the NCP reagent demonstrated a more precise and more sensitive determination of the uric acid compared to the determination with 4-aminoantipyrine (4-AA) as the coupling regent. The sensitivity of the method determined from the calibration curve was 0.71 absorbance units per mmol/L of uric acid; the limit of detection was LOD = 0.0035 mmol/L and the limit of quantification was LOQ = 0.015 mmol/L of uric acid.


2012 ◽  
Vol 2012 ◽  
pp. 1-5
Author(s):  
Jiangman Liu ◽  
Huan Yang ◽  
Yun Zhang ◽  
Min Wu ◽  
Haixiang Zhao ◽  
...  

A sensitive chemiluminescence (CL) method, based on the inhibitory effect of roxithromycin (ROX) on the CL reaction between luminol and dissolved oxygen in a flow-injection system, was first proposed for the determination of ROX at picogram levels. The decrement of CL intensity was linearly proportional to the logarithm of ROX concentrations ranging from 0.1 to 100 pg mL-1, giving the limit of detection (LOD) of 0.03 pg mL-1 (3σ). At a flow rate of 2.0 mL min-1, a complete analytical procedure including sampling and washing could be performed within 0.5 min, with relative standard deviations (RSDs) of less than 5.0% (n=5). The proposed procedure was applied successfully to the determination of ROX in pharmaceutical, human serum, and urine with the recoveries ranging from 90.0 to 110.0%.


2019 ◽  
Vol 0 (0) ◽  
Author(s):  
T. Venu Gopal ◽  
Tukiakula Madhusudana Reddy ◽  
P. Shaikshavali ◽  
G. Venkataprasad ◽  
P. Gopal

Abstract A small scale of environmentally hazardous 4-aminophenol can show significant impact on human health. Hence, in the present work, we have designed L-Valine film (Vf) modified carbon paste electrode (Vf/CPE) for the determination of 4-aminophenol. Herein, a facile in-situ L-Valine film was developed by electrochemical polymerization method onto the surface of bare carbon paste electrode (BCPE) with the help of cyclic voltammetry (CV) technique. A two-folds of electrochemical peak current enhancement was achieved at Vf/CPE in comparison with BCPE towards the determination of 4-aminophenol in optimum pH 7.0 of phosphate buffer solution (PBS). This was achieved due to the large surface area and conductive nature of Vf/CPE, which was concluded through the techniques of cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The effect of pH of buffer and scan rate studies were successfully studied. Morphological changes of BCPE and Vf/CPE was studied with the help of scanning electron microscopy (SEM). The formation of Vf on CPE was also analyzed by Fourier transform infrared (FTIR) spectra. Under the optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) values of 4-aminophenol were estimated with the aid of chronoamperometry (CA) technique and was found to be 9.8 μM and 32 μM, respectively. Finally the proposed method was found to have satisfactory repeatability, reproducibility and stability results with low relative standard deviation (RSD) values.


Sensors ◽  
2019 ◽  
Vol 19 (24) ◽  
pp. 5560 ◽  
Author(s):  
Somasekhar R. Chinnadayyala ◽  
Jinsoo Park ◽  
Young Hyo Kim ◽  
Seong Hye Choi ◽  
Sang-Myung Lee ◽  
...  

An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum (HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (ΔC) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in ΔC with the addition of CRP concentrations over a range of 0.01–10,000 ng mL−1. The electrode showed detection limits of 0.025 ng mL−1 and 0.23 ng mL−1 (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 °C in 1× PBS.


Author(s):  
Rui Zhang ◽  
Qiannan You ◽  
Mingming Cheng ◽  
Mingfeng Ge ◽  
Qian Mei ◽  
...  

Circulating tumor cells (CTCs) are metastatic tumor cells that shed into the blood from solid primary tumors, and their existence significantly increases the risk of metastasis and recurrence. The timely discovery and detection of CTCs are of considerable importance for the early diagnosis and treatment of metastasis. However, the low number of CTCs hinders their detection. In the present study, an ultrasensitive electrochemical cytosensor for specific capture, quantitative detection, and noninvasive release of EpCAM-positive tumor cells was developed. The biosensor was manufactured using gold nanoparticles (AuNPs) to modify the electrode. Three types of AuNPs with controllable sizes and conjugated with a targeting molecule of monoclonal anti-EpCAM antibody were used in this study. Electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) of the cytosensors were performed to evaluate the cell capture efficiency and performance. The captured 4T1 cells by the AuNPs hindered electron transport efficiency, resulting in increased EIS responses. The cell capture response recorded using EIS or DPV indicated that the optimal AuNPs size should be 17 nm. The cell capture response changed linearly with the concentration range from 8.0 × 10 to 1 × 107 cells/mL, and the limit of detection was 50 cells/mL. After these measurements, glycine-HCl (Gly-HCl) was used as an antibody eluent to destroy the binding between antigen and antibody to release the captured tumor cells without compromising their viability for further clinical research. This protocol realizes rapid detection of CTCs with good stability, acceptable assay precision, significant fabrication reproducibility with a relative standard deviation of 2.09%, and good recovery of cells. Our results indicate that the proposed biosensor is promising for the early monitoring of CTCs and may help customize personalized treatment options.


Sensors ◽  
2020 ◽  
Vol 20 (17) ◽  
pp. 4738 ◽  
Author(s):  
Tatiana Kulikova ◽  
Vladimir Gorbatchuk ◽  
Ivan Stoikov ◽  
Alexey Rogov ◽  
Gennady Evtugyn ◽  
...  

The determination of antibiotics in food is important due to their negative effect on human health related to antimicrobial resistance problem, renal toxicity, and allergic effects. We propose an impedimetric aptasensor for the determination of kanamycin A (KANA), which was assembled on the glassy carbon electrode by the deposition of carbon black in a chitosan matrix followed by carbodiimide binding of aminated aptamer mixed with oligolactide derivative of thiacalix[4]arene in a cone configuration. The assembling was monitored by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. In the presence of the KANA, the charge transfer resistance of the inner interface surprisingly decreased with the analyte concentration within 0.7 and 50 nM (limit of detection 0.3 nM). This was attributed to the partial shielding of the negative charge of the aptamer and of its support, a highly porous 3D structure of the surface layer caused by a macrocyclic core of the carrier. The use of electrostatic assembling in the presence of cationic polyelectrolyte decreased tenfold the detectable concentration of KANA. The aptasensor was successfully tested in the determination of KANA in spiked milk and yogurt with recoveries within 95% and 115%.


Sign in / Sign up

Export Citation Format

Share Document