scholarly journals Performance of Fluid Viscous Dampers on Seismic Response of RCC Structures

Structures are mainly subjected to various types of loading conditions such as dead loads, live loads and dynamic loads such as earthquake and wind loads etc. The earthquake creates vibration at the base of the structure. In modern seismic design, the damping devices are used to reduce the seismic energy and enable the control of the structural response of the structure. In the present study, the seismic behavior of a structure connected with and without Fluid Viscous Dampers (FVD) has been describes. The software ETABS 2016 is used to perform the modeling and analysis of G +10 storey building by considering seismic zone IV. For analysis IS codes have been referred. The response of the RCC building is evaluated using Push-over and Time history analyses. Fluid Viscous Dampers are suggested to the structure, to control the seismic response and increase the stiffness of the structure.

2021 ◽  
Author(s):  
Hu Daohang ◽  
Zhao Xin

<p>This paper introduces a new idea in the reconstruction and continuation projects. By arranging damping devices, the additional damping of the structure is increased, thereby reducing the dynamic response of the structure under the new seismic precautionary criterion. This paper focuses on the study of viscous dampers which one of the damping device, introduces the energy dissipation principle of viscous dampers, and combines a two-story plane frame case to analyze and compare the dynamic response between non-damping structure and damping structure. The location and quantity of the arrangement were compared with multiple models. Through analysis, it can be seen that by equipping with viscous dampers, seismic energy can be effectively dissipated, thereby reducing the workload of structural reinforcement and having less impact on the original structure. Finally, two commonly analysis methods in damping structures are studied, direct integration method and fast nonlinear analysis (FNA), the main differences between the two analysis methods are introduced, and the calculation results of the two methods are compared and analyzed.</p>


2020 ◽  
Vol 156 ◽  
pp. 05026
Author(s):  
Fauzan ◽  
Afdhalul Ihsan ◽  
Mutia Putri Monika ◽  
Zev Al Jauhari

The amount of potential investment in Padang City, Indonesia since 2017 attracted many investors to contribute to the city. One of the investments is a 12-story hotel that will be constructed in By Pass Street of the city. The hotel is located in a high seismic zone area, so the seismic base isolation has been proposed to be used in the hotel building. The main aim of using a seismic base isolation device is to reduce the inertia forces introduced in the structure due to earthquakes by shifting the fundamental period of the structure out of dangerous resonance range and concentration of the deformation demand at the isolation system. An analytical study on the Reinforced Concrete (RC) hotel building with and without rubber bearing (RB) base isolation is carried out using the response spectrum and time history analysis methods. The results show that internal forces and inter-story drift of the building with high damping rubber bearing (HDRB) are lower than that of the fixed base with a remarkable margin. From this study, it is recommended to use the HDRB base isolation for medium and high rise buildings with soft soil in Padang City, Indonesia.


2016 ◽  
Vol 10 (12) ◽  
pp. 245
Author(s):  
Solmaz Yaghobzadeh

Explained ways to strengthen structures against lateral dynamic loads can be divided into two broad categories. The first part is the structural systems for controlling seismic displacement and second part is the use of applying systems of control forces. Response mechanism of structures using control systems are improved and greatly reduce the risks of damage caused by earthquakes.Today the use of these control systems in buildings have been increased and it’s important to reduce vibration of structures is felt more than ever. As well as to improve the dynamic behavior of nearby buildings, control systems can be installed between adjacent buildings as activated, semi-active and inactivated systems. The main purpose of this study is the use of control systems in two similar adjacent buildings to reduce the entire system response which will be the analytical study of the impact of viscous dampers to control system performance.In order to analysis of modeling to improve the dynamic behavior of different adjacent buildings connected with dampers, two models of the original sample will be examined in this article. All examples are different from each other and to elicit response analysis and time history software SAP 2000was used. According to the results the effect of fluid viscous dampers for tall buildings compared shorter building, is less. Also, these dampers for adjacent buildings with different heights than buildings with same height are more effective.


2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Xiongjun He ◽  
Yongchao Yang ◽  
Xiang Xiao ◽  
Yulin Deng

To optimize the aseismic performance of nonlinear fluid viscous dampers (FVD) of cable-stayed bridge in the highly seismic zone, Xigu Yellow River Bridge in northwest China is taken as an example. Nonlinear time-history analysis method is used to research on the relation among the internal forces, displacements, and damping parameters of the 650 tonnage FVD. The method of getting the minimum of binary functions is used to obtain the optimal parameters of FVD. Also, the 1 : 1 full-scale FVD model is made and used in the constitutive relation test. Then the test result of the damping parameters can be got by normal equation method. The optimized method to obtain the damping parameters is further verified. The results indicate that seismic response in key positions of the cable-stayed bridge can be reduced by installing longitudinal nonlinear FVD between the towers and girders if choosing reasonable damping parameters C and ξ. The optimal damping parameters can be calculated accurately by the proposed method of optimizing damping parameters of nonlinear FVD, and the constitutive relation test verifies the correctness of the optimization analysis method. Conclusions concerned can be applied to the design of nonlinear FVD for cable-stayed bridges.


Base isolation is an effective way to protect large structures from earthquake damage. It is a costly approach, as the entire structure must be supported on elastomeric or sliding bearings. Viscous dampers distributed throughout an otherwise conventional structure can achieve the same result at a significantly lower cost. Dampers are used to resist lateral forces coming on the structure. Dampers are the energy dissipating devices which also resist displacement of Reinforced Concrete (RC) buildings during an earthquake. These dampers help the structure to reduce buckling of columns thereby increasing the stiffness of the structure. During earthquakes, multi-storeyed buildings get damaged and as a result, large deformation occurs. Dampers reduce vibration and deformation of structural elements during an earthquake. Retrofitting buildings with fluid viscous dampers (FVDs) can improve Interstorey drifts and floor accelerations. In the present study, an RC framed building is modelled and analysed under Southern Sumatra and Chile earthquakes to evaluate the performance of the structure and its elements with and without energy dissipators. For the study, a model (G+19) with and without energy dissipators is modelled in ETABS. The seismic force is applied based on the time history data of the models pertaining to Southern Sumatra and Chile Earthquake. Response Spectrum analysis has been carried out to find the lateral displacements, storey shear and Base shear for the model with and without dampers. The lateral displacement, storey drift, storey shear and Base shear are found to less for the model with Linear FVDs when compared to the model with Non-Linear FVDs and without FVDs.


2011 ◽  
Vol 27 (3) ◽  
pp. 719-744 ◽  
Author(s):  
Matthew R. Eatherton ◽  
Jerome F. Hajjar

There has been widespread interest in the development and use of self-centering (SC) lateral resisting systems that eliminate residual drifts after large earthquakes. SC systems often include a restoring force component and a component that dissipates seismic energy. Typically, it is assumed that the criterion for self-centering is satisfied if the restoring force is proportioned to be greater than the force required to yield the energy dissipating component. A parametric SDOF study was conducted using time-history analyses on several prototype buildings to quantify the effect of varying system parameters on structural response including residual drifts. The ambient resistance of the rest of the building was considered, as well as proportioning the system with less restoring force than the yield capacity of the dissipative component. In addition, the probabilistic mechanism that creates a propensity for reducing residual drifts in systems with little or no restoring force is explored and quantified. It was found that a restoring force that is at least one-half of the force required to yield the dissipative component will still reliably eliminate residual drifts in a non-softening system.


2020 ◽  
Vol 6 ◽  
pp. 98-118
Author(s):  
Manisha V. Waghmare ◽  
Suhasini N. Madhekar ◽  
Vasant A. Matsagar

The numerical investigation on the seismic response of RC elevated liquid storage tanks installed with viscous dampers is presented. A discrete two-mass model for the liquid and multi-degree of freedom system for staging, installed with the dampers are developed for Reinforced Concrete (RC) elevated liquid storage tanks. The elevated tank is assessed for seismic response reduction when provided with Linear Viscous Damper (LVD) and Nonlinear Viscous Damper (NLVD), installed in the staging. The RC elevated liquid storage tanks are analyzed for two levels of liquid containment in the tank, 100% and 25% of the tank capacity. Three Configurations of placements of dampers viz. dampers at alternate levels (Configuration I and Configuration II) and dampers at all the panels of the staging of the tank (Configuration III) are considered. To study the effect of peak ground acceleration, eight real earthquake time histories with accelerations varying from 0.1 g to 0.93 g are considered. The nonlinearity in the viscous damper is modified by taking force proportional to various velocity exponents. It is found that the nonlinear viscous dampers with lower damping constant result in a comparable reduction in the response of RC elevated liquid storage tank, to that of linear viscous dampers with higher damping constant. A lower damping constant signifies compact the size of the damper. Doi: 10.28991/cej-2020-SP(EMCE)-09 Full Text: PDF