scholarly journals Calculation, modeling and description features of cascade systems in MATLAB

Author(s):  
Nikolay Bilfeld ◽  
Yulia Volodina

A simulation of a cascade system, during which the problem of determining the transfer function of a cascade system for analytical reception of the transient response occurred, is performed. It is proven that the equivalent object used in many modelling works and the cascade system are not the same. Transients obtained by using an equivalent object are different from real transients in a cascade control system. The analytical expression of the description of cascade system is received as a result of researches.

Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 704
Author(s):  
Sylwester Sobieraj ◽  
Grzegorz Sieklucki ◽  
Józef Gromba

The conversion of the electrical energy into the mechanical is usually realized by a motor, power electronics and cascade control. The relative stability (Θ-stability), i.e., the displacement of its eigenvalues of this system is analyzed for a drive with a BLDC motor. The influence of changing the basic parameters of the motor and power supply system on the drive operation is considered. 4th order closed-loop transfer-function of the cascade control is presented, where boundaries of the transfer-function coefficients are used. The cascade system which uncertainty of the resistance, inductance, flux and gain parameters is analyzed. Theoretical calculations for the cascade control, simulations and laboratory tests are included in the article.


2013 ◽  
Vol 846-847 ◽  
pp. 321-324 ◽  
Author(s):  
Le Peng Song ◽  
Hua Bin Wang

As liquid level cascade system has the character the issue of non-linearity ,time variability and the overshoot,tradition PID control can not meet the requirement of precise molding system. So devise a self-_ adaptive fuzzy PID control .A self-_ adaptive fuzzy PID control combined PID to control calculate way and faintness to control the advantage of method, this text permits water tank to carry on mathematics model to design the double permit a water tank liquid misty PID string class control system. Matlab/Simulink and fuzzy logic toolbox are simulated to the single loop PID control system,the cascade control system and the cascade control system based on fuzzy self-tuning PID were simulated with Simulink. The analysis and simulation results indicate that the character issue of non-linearity ,time variability and the overshoot of the liquid level cascade control system based on a self-_ adaptive fuzzy PID controller are superior to previous of two methods.


Author(s):  
Rangaswamy Karthikeyan ◽  
Sreekanth Pasam ◽  
Sandu Sudheer ◽  
Vallabhaneni Teja ◽  
Shikha Tripathi

Nanoscale ◽  
2020 ◽  
Vol 12 (44) ◽  
pp. 22615-22627
Author(s):  
Ao Hu ◽  
Xiaobing Chen ◽  
Qunjie Bi ◽  
Yang Xiang ◽  
Rongrong Jin ◽  
...  

A parallel and cascade controllable magnetofection system for synergistic tumor-association macrophage repolarization and tumor cell suppression in breast cancer treatment.


2019 ◽  
Vol 292 ◽  
pp. 01064 ◽  
Author(s):  
Donka Ivanova ◽  
Nikolay Valov ◽  
Martin Deyanov

In this article the application of genetic algorithm for tuning of HVAC cascade system is proposed. The tuning procedure for a cascade system is very time-consuming and practice shows that additional controller tuning is needed when classical method is used. The main problem in classical method is the interconnection between the parameters of the two controllers. The proposed optimal tuning procedure overcomes the disadvantages. It is based on the following criteria: minimum integral square error, minimum settling time and minimum overshoot. The best process quality is achieved with PI controller in the inner loop and a PID controller in the outer loop of the cascade HVAC system. The proposed method for simultaneous tuning of controller parameters in a cascade control system can be applied in different control systems.


Symmetry ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 379 ◽  
Author(s):  
Qian Zhang ◽  
Ya-Gang Wang ◽  
Fei-Fei Lee ◽  
Wei Zhang ◽  
Qiu Chen

Due to the fact that cascade control can improve the single-loop’s performance well and reduce the integral error from disturbance response, it has been one of the most important control strategies in industrial production, especially in thermal power plant and chemical engineering. However, most of the existing research is based on the Gaussian system and other few studies on the non-Gaussian cascade disturbance system also have obvious defects. In this paper, an effective control loop performance assessment (CPA) of cascade control system for many non-Gaussian distributions even the unknown mixture disturbance noise has been proposed. Compared to the minimum variance control (MVC) approach, the minimum entropy control (MEC) method can obtain a more accurate estimate. In this method, like MVC, the primary loop output and secondary loop output can be represented as invariant and dependent terms, then adopted estimated distribution algorithm (EDA) is used to achieve the system model and disturbances. In order to show the effectiveness of MEC, some simulation examples based on different perturbations are given.


Sign in / Sign up

Export Citation Format

Share Document