scholarly journals Fire-resistance Rating of Square Steel Tubes and Concrete-filled Square Steel Tubular Columns Protected with Ultra-thin Fire-retardant Coating

2020 ◽  
Vol 71 (6) ◽  
pp. 437-451
Author(s):  
Ansheng Wu ◽  
Bo Zhang ◽  
Le Tian

To promote and criterionize the application of ultra-thin the fireproof coating s to building structures, four concrete-filled square steel tubular (CFSST) pillars as well as two square steel tubes, each protected along with ultra-thin the fireproof coating , were subjected to full-scale fire tests to investigate their fireproof level on the basis of the ISO 834 criterion time�degrees curve. Test results revealed not only the temperature variation characteristics of specimens suffered from inconsistent fire exposure, but also effects of the steel ratio of the test specimen and the number of fire-exposed sides on the fire-refractory level of the test specimen. Test results demonstrated that when protected with an ultra-thin the fireproof coating , the heating rate of the specimens was considerably lower than that of the test furnace, suggesting that the ultra-thin the fireproof coating exhibits good thermal insulation performance. The test results were compared with China�s current criterions for the fire-refractory level of square steel tubes and CFSST pillars, indicating that the criterions would lead to a relatively conservative fire-safe design for four-side fire exposure.

2014 ◽  
Vol 638-640 ◽  
pp. 197-201
Author(s):  
Yan Chong Pan ◽  
Guo Hui Wang ◽  
Kai Xiang

Fire safety is one of the most important performances index to evaluate building structures. The property of building members after exposure to fire involved with the safety of buildings after fire, and it will be necessary to estimate the post-fire residual strength of the structure in order to decide the appropriate strategy for repair. This paper summarizes the research progress of concrete-filled steel tubular (CFST) columns. Basic mechanical properties of conventional CFST columns after exposure to fire, CFST columns after the whole fire exposure process under sustained axial load, and CFST columns with special forms after exposure to fire are discussed.


2010 ◽  
Vol 163-167 ◽  
pp. 749-753
Author(s):  
Yao Ji ◽  
Xin Tang Wang ◽  
Ming Zhou ◽  
Wan Zhen Wang

In order to look into the causes of fire response and post-fire bearing capacity of the steel tubular columns protected with different materials, the fire test was conducted for a set of circular steel tubes protected with different materials such as gypsum fireproof panel, bamboo plywood and the ordinary lumber core plywood, and the steel tube without any protective material. The fire response temperature of surface of steel tubes is measured and the axial compressive bearing capacity of the specimens after fire are tested and analyzed. The test results show that gypsum fireproof panel has the best fire protection characteristics, the ordinary lumber core plywood and bamboo plywood can also retard rising of the surface temperature of the steel tubes during the initial 35min although they are combustible materials. It is found that the post-fire bearing capacity of the steel tubes protected with different materials varies evidently, and the maximum value of response temperature has the greatest effect.


2021 ◽  
Vol 11 (6) ◽  
pp. 2521
Author(s):  
Feng Jiang ◽  
Jianyong Liu ◽  
Wei Yuan ◽  
Jianbo Yan ◽  
Lin Wang ◽  
...  

Improving the fire resistance of the key cables connected to firefighting and safety equipment is of great importance. Based on the engineering practice of an oil storage company, this study proposes a modification scheme that entails spraying fire-retardant coatings on the outer surface of a cable tray to delay the failure times of the cables in the tray. To verify the effect, 12 specimens were processed using five kinds of fire-retardant coatings and two kinds of fire-resistant cotton to coat the cable tray. The specimens were installed in the vertical fire resistance test furnace. For the ISO 834 standard fire condition, a fire resistance test was carried out on the specimens. The data for the surface temperature and the insulation resistance of the cables in trays were collected, and the fireproof effect was analyzed. The results showed that compared with the control group, the failure time of the cable could be delayed by 1.57–14.86 times, and the thicker the fire-retardant coatings were, the better the fireproof effect was. In general, the fire protection effect of the fire-retardant coating was better than that of the fire-resistant cotton.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1429
Author(s):  
Ismael García ◽  
Miguel A. Serrano ◽  
Carlos López-Colina ◽  
Fernando L. Gayarre ◽  
Jesús M. Suárez

The use of Rectangular Hollow Sections (RHS) as columns in steel construction includes important advantages like higher mechanical strength and fire resistance. However, the practical demountable bolted joints between beams and columns are not easy to execute, due to impossibility of access to the inner part of the tube. The use of threaded studs welded to the face of the tube and bolted to the beam by means of angle cleats is one of the cheaper and most efficient solutions to obtain beam–column joints with a semi-rigid behavior, as is usually sought in building structures. Nevertheless, it is important to point out that the stud-diameter and the stud-class selection may affect the mechanical properties of the welded parts of the joint. In this paper, 8MnSi7 (with a commercial designation K800) and 4.8 threaded studs were welded to RHS steel tubes and mechanical properties on the weld, the Heat Affected Zones (HAZ), and the base metal were obtained in two different ways: through a correlation with the Vickers hardness and by means of the Small Punch Test (SPT). A study of the microstructure and tensile tests on the threaded studs and in the columns was also carried out. The research involved different types of stud qualities, tube wall thicknesses, and stud diameters. The work presented in this paper proved that in most cases, the welded joint between these studs and the RHS steel tubes present a reasonable static behavior that fulfils the requirements for the beam–column joints under static loading.


2014 ◽  
Vol 919-921 ◽  
pp. 1794-1800
Author(s):  
Xin Zhi Zheng ◽  
Xin Hua Zheng

Abstract: 7 square steel tubular columns were tested to discuss the ultimate axial bearing capacity, ductility performance and the steel consumption under stiffened by steel belts and binding bars of different cross-sections. Test results indicate that only by increasing fewer amounts of steel usage, stiffened square CFST columns with binding bars can not only improve the overall effects of restraint and alleviate regional local buckling between the binding bars, but also improve the bearing capacity of concrete filled square steel tubular columns. The utility benefits and the economical benefit is considerable, deserving extensive use.


Crystals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1434
Author(s):  
Muhammmad Faisal Javed ◽  
Haris Rafiq ◽  
Mohsin Ali Khan ◽  
Fahid Aslam ◽  
Muhammad Ali Musarat ◽  
...  

This experimental study presents concrete-filled double-skin tubular columns and demonstrates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10% strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004).


2021 ◽  
Vol 2021 ◽  
pp. 1-20
Author(s):  
Xianglong Liu ◽  
Jicheng Zhang ◽  
Hailin Lu ◽  
Ning Guan ◽  
Jiahao Xiao ◽  
...  

The mechanical properties of T-shaped concrete-filled steel tubular (TCFST) short columns under axial compression after elevated temperature are investigated in this paper. A total of 30 TCFST short columns with different temperature (T), steel ratio (α), and duration of heating (t) were tested. The TCFST column was directly fabricated by welding two rectangular steel tubes together. The study mainly investigated the failure modes, the ultimate bearing capacity, the load-displacement, and the load-strain performance of the TCFST short columns. Experimental results indicate that the rectangular steel tubes of the TCFST column have deformation consistency, and the failure mode consists of local crack, drum damage, and shear failure. Additionally, the influence of high temperature on the residual bearing capacity of the TCFST is significant, e.g., a higher temperature can downgrade the ultimate bearing capacity. Finally, a finite element model (FEM) is developed to simulate the performance of the TCFST short columns under elevated temperature, and the results agree with experimental values well. Overall, this investigation can provide some guidance for future studies on damage assessment and reinforcement of the TCFST columns.


2013 ◽  
Vol 785-786 ◽  
pp. 191-198
Author(s):  
Li Jun Li ◽  
Feng Li ◽  
Ze Jiang Zhang

Different flame retardant contents of polyurethane rigid foam (PRF) were prepared in this paper. Combustion performances of PRF were tested by cone calorimeter (CONE). Fire risk of PRF was evaluated based on Analytic Hierarchy Process (AHP). The evaluation results were compared with the traditional LOI results. It was found that the evaluation method based on AHP combined with CONE test results for evaluating fire hazard of thermal insulation material for exterior walls of buildings is more accurate and objective compared with the method of the traditional LOI.