scholarly journals Issues relating to the efficient application of passive solar protection in multi-family residential buildings

2020 ◽  
pp. 1-16
Author(s):  
Justyna Kobylarczyk ◽  
Janusz Marchwiński ◽  
Katarzyna Zielonko-Jung

The following article is intended to discuss the issues concerning the introduction of passive measures aimed at improving solar protection in multi-family buildings. A system of classifying these methods into two groups of solutions (architectural and material-building) was applied. The first group includes issues concerning facade design, the spatial features of which (such as loggias, balconies and other overhangs) can be treated as one of the solar protection methods. The authors’ own studies are presented and expressed in a sequence of formulas. The formulas enable assessment of the effectiveness of the above elements, depending on external conditions. As far as the second group is concerned, material-construction solutions for building facades and roofs are discussed. The solutions mentioned include solar-control glazing, spatial shading elements (such as venetian blinds, roller blinds), roof and façade vegetation, and the thermal mass of the building. The essence of the functioning of the analysed solutions in relation to the characteristic functional specificity of multi-family buildings is discussed. Problematic areas of application of the above methods are indicated. As shown in the study, problematic areas may include a group of utilitarian-operating, economic and aesthetic issues, in the case of which the use of passive solutions encounters limitations. In conclusion, the possibilities for alleviating these limitations are highlighted. The authors’ own solutions presented in the following paper can contribute to energy savings and may thus prove beneficial for environmental reasons, thereby serving the aims of sustainable development.

Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 6068
Author(s):  
Remy Carlier ◽  
Mohammad Dabbagh ◽  
Moncef Krarti

This paper evaluates the potential energy savings when switchable insulation systems (SIS) are applied to walls of residential buildings located in Belgium and other locations in Europe. The study considers two low-energy prototypical dwellings (an apartment and a detached house) that are representative of post-2010 constructions and renovations in Belgium. Using an 3R2C-based analysis tool, the performance of both dwellings is evaluated with static and dynamic wall insulation systems. First, the switchable insulating system is described along with its associated simple 2-step rule-based control strategy. Then the modeling strategy and simulation analysis tools are presented. In Belgium, it was found that SIS-integrated walls allow energy savings up to 3.7% for space heating and up to 98% for cooling. Moreover, it was found that to further reduce the energy consumption of SIS-integrated buildings in various European climates, thermal mass placement needs to be considered. By optimizing the placement and the parameters of the various wall layers, it is possible to increase the space heating savings by up to a factor of 4 and those of cooling by up to a factor of 2.5.


Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 6025 ◽  
Author(s):  
Erik Schmerse ◽  
Charles A. Ikutegbe ◽  
Amar Auckaili ◽  
Mohammed M. Farid

A characteristic feature of lightweight constructions is their low thermal mass which causes high internal temperature fluctuations that require high heating and cooling demand throughout the year. Phase change materials (PCMs) are effective in providing thermal inertia to low-thermal-mass buildings. This paper aims to analyse the thermal behaviour of two proposed lightweight buildings designed for homeless people and to investigate the potential benefit achievable through the use of different types of PCM in the temperate climatic conditions of Christchurch, New Zealand. For this purpose, over 300 numerical simulations were conducted using DesignBuilder® simulation software. The bulk of the simulations were carried out under the assumption that the whole opaque building envelope is equipped with PCM. The results showed significant energy saving and comfort enhancement through the application of PCMs. The integration of PCM in single-structure components led to substantial energy savings between 19% and 27% annually. However, occupant behaviour in terms of ventilation habits, occupancy of zones, etc. remains one of the biggest challenges in any simulation work due to insufficient data.


2019 ◽  
Vol 111 ◽  
pp. 03051
Author(s):  
Daria Zukowska ◽  
Myrto Ananida ◽  
Jakub Kolarik ◽  
Mandana Sarey Khanie ◽  
Toke Rammer Nielsen

Advancing energy efficient renovation solutions in residential buildings necessitate adopting high-insulation and airtightness to avoid heat loss through transmission and infiltration, which can result in overheating. Elevated indoor temperatures have been proved to have a highly negative effect on occupants’ health and well-being. Energy efficient solutions to the problem with overheating include limiting the solar heat gains through the glazed parts of the facade and effective ventilation. A typical Danish residential apartment building from 1850-1900 recently refurbished, was modelled with five different solar shading devices and three typical ventilation solutions. External solar shading could efficiently reduce overheating below the limits specified by the national building regulations in all tested cases. The marquisolette reduced the number of occupied hours with temperature above 27 °C by min. 85%, the external venetian blinds by min. 81%, and the drop arm awning by min. 74% compared to the situation without solar shading. The internal solar shading as venetian blinds and roller blind could reduce the overheating hours by 20-40%, which was efficient only in combination with mechanical ventilation in case of south and east building orientations.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4117
Author(s):  
Tadeusz Kuczyński ◽  
Anna Staszczuk ◽  
Piotr Ziembicki ◽  
Anna Paluszak

The main objective of this paper is to demonstrate the effectiveness of increasing the thermal capacity of a residential building by using traditional building materials to reduce the risk of its excessive overheating during intense heat waves in a temperate climate. An additional objective is to show that the use of this single passive measure significantly reduces the risk of overheating in daytime rooms, but also, though to a much lesser extent, in bedrooms. Increasing the thermal mass of the room from light to a medium heavy reduced the average maximum daily temperature by 2.2K during the first heat wave and by 2.6K during the other two heat waves. The use of very heavy construction further reduced the average maximum temperature for the heat waves analyzed by 1.4K, 1.2K and 1.7K, respectively, giving a total possible reduction in maximum daily temperatures in the range of 3.6 °C, 3.8 °C and 4.3 °C. A discussion of the influence of occupant behavior on the use of night ventilation and external blinds was carried out, finding a significant effect on the effectiveness of the use of both methods. The results of the study suggest that in temperate European countries, preserving residential construction methods with heavy envelopes and partitions could significantly reduce the risk of overheating in residential buildings over the next few decades, without the need for night ventilation or external blinds, whose effectiveness is highly dependent on individual occupant behavior.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3876
Author(s):  
Sameh Monna ◽  
Adel Juaidi ◽  
Ramez Abdallah ◽  
Aiman Albatayneh ◽  
Patrick Dutournie ◽  
...  

Since buildings are one of the major contributors to global warming, efforts should be intensified to make them more energy-efficient, particularly existing buildings. This research intends to analyze the energy savings from a suggested retrofitting program using energy simulation for typical existing residential buildings. For the assessment of the energy retrofitting program using computer simulation, the most commonly utilized residential building types were selected. The energy consumption of those selected residential buildings was assessed, and a baseline for evaluating energy retrofitting was established. Three levels of retrofitting programs were implemented. These levels were ordered by cost, with the first level being the least costly and the third level is the most expensive. The simulation models were created for two different types of buildings in three different climatic zones in Palestine. The findings suggest that water heating, space heating, space cooling, and electric lighting are the highest energy consumers in ordinary houses. Level one measures resulted in a 19–24 percent decrease in energy consumption due to reduced heating and cooling loads. The use of a combination of levels one and two resulted in a decrease of energy consumption for heating, cooling, and lighting by 50–57%. The use of the three levels resulted in a decrease of 71–80% in total energy usage for heating, cooling, lighting, water heating, and air conditioning.


Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

A humidity-sensitive demand-controlled ventilation system is known for many years. It has been developed and commonly applied in regions with an oceanic climate. Some attempts were made to introduce this solution in Poland in a much severe continental climate. The article evaluates this system's performance and energy consumption applied in an 8-floor multi-unit residential building, virtual reference building described by the National Energy Conservation Agency NAPE, Poland. The simulations using the computer program CONTAM were performed for the whole hating season for Warsaw's climate. Besides passive stack ventilation that worked as a reference, two versions of humidity-sensitive demand-controlled ventilation were checked. The difference between them lies in applying the additional roof fans that convert the system to hybrid. The study confirmed that the application of demand-controlled ventilation in multi-unit residential buildings in a continental climate with warm summer (Dfb) leads to significant energy savings. However, the efforts to ensure acceptable indoor air quality require hybrid ventilation, which reduces the energy benefits. It is especially visible when primary energy use is analyzed.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2021 ◽  
Author(s):  
Omar Siddiqui

The applicability of utilizing a variety of thermal mass including phase change materials with commonly used building materials is investigated through the use of simulations and physical testing. The thermal performance and occupant comfort potential of a novel solid-solid phase change material, known as Dal HSM, is compared and contrasted to commonly available forms of thermal mass. Detailed experimentation is conducted to successfully integrate Dal HSM with gypsum and concrete. The measurement of physical characteristics such as compressive strength and modulus of rupture is conducted to ensure that the PCM-composite compound retains the structural integrity to be utilized in a typical building. The use of thermal mass in the Toronto Net Zero house was found to contribute to energy savings of 10-15% when different types of thermal mass were used. The comfort level of the indoor occupants was also found to increase. The performance of Dal HSM was found to be comparable to a commercially available PCM known as Micronal in the heating mode. The cooling mode revealed that Dal HSM provided slightly lower energy savings when compared to Micronal due to a lower phase transition temperature and latent heat. The performance of physical test revealed a decrease in the compressive strength as the concentration of Dal HSM was increased in the PCM-gypsum specimens. Tests were also performed to analyze the impact of increasing the PCM concentration on the flexural strength of PCM-gypsum composite.


2018 ◽  
Vol 164 ◽  
pp. 01007
Author(s):  
Dany Perwita Sari ◽  
Yun-shang Chiou

There are some architectural factors in the energy saving design of residential houses in Taiwan. In addition, in rural area, window glazing is a key factor to reducing electricity. For these purposes, a simulation model of exterior shading has been done in this study. Various types of shading devices have been analysed and compared in terms of energy savings. Simulation analysis by DesignBuilder reveals that shading devices has substantial impact to minimizing energy consumption. The results derived in this paper could provide useful suggestions for the shading design of residential buildings at rural area in Taiwan.


Sign in / Sign up