scholarly journals Effect of Pretreatment, Fermentation Medium and Solid Loading Rate on The Production of Bio- Ethanol from Fruit Waste Using Saccharomyces cerevisiae

2021 ◽  
Vol 2 (2) ◽  
pp. 121-131
Author(s):  

The rapid increase in world’s population and growing industrialization are major sources of energy consumption, therefore energy demand is expanding continuously. The first-generationfeedstocklike maize, sugarcane, wheat,etc.can be used to producebioethanol, but due to food and feed security issues,first-generation feedstockcannot beused to producebioethanol.To overcome the feed and food security issue related to first-generationfeedstock, waste fruitcan beused to produce bioethanol.In this experiment, firstly the effect of pretreatment technique on glucose generationisobserved. Simultaneous saccharification and fermentation(SSF)experiment carried outat a pH of 4.5 and temperature of 30°C for 48 hwithfermentation helping nutrientsusing Saccharomyces cerevisiae. A nearly equal amount of glucose concentration is observed from samplestreated with hot water, 1%H2SO4, 5%H2SO4,and without any pretreatment. SSF results also revealed that fermentation helping nutrientshasnosignificanteffecton the production of bioethanol at the same concentration. Second part of the experiment deals with the effect of solid loading rate, which is directly proportional to glucose concentration 10-20% (w/w) and time for fermentation (48-96 hours) on generation of bioethanolfrom fruit waste. Solid loadingrate and reaction time for SSF hada significant effect on the production of bioethanol. Optimized 41.19gL-1bioethanol concentration was observed with solid load rate of 20% (w/w) and fermentation period of 58.8 h.High yield ofbioethanolcan be achieved using fruit waste at domestic scale with minimum operational requirements

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Martin Pullinger ◽  
Jonathan Kilgour ◽  
Nigel Goddard ◽  
Niklas Berliner ◽  
Lynda Webb ◽  
...  

AbstractThe IDEAL household energy dataset described here comprises electricity, gas and contextual data from 255 UK homes over a 23-month period ending in June 2018, with a mean participation duration of 286 days. Sensors gathered 1-second electricity data, pulse-level gas data, 12-second temperature, humidity and light data for each room, and 12-second temperature data from boiler pipes for central heating and hot water. 39 homes also included plug-level monitoring of selected electrical appliances, real-power measurement of mains electricity and key sub-circuits, and more detailed temperature monitoring of gas- and heat-using equipment, including radiators and taps. Survey data included occupant demographics, values, attitudes and self-reported energy awareness, household income, energy tariffs, and building, room and appliance characteristics. Linked secondary data comprises weather and level of urbanisation. The data is provided in comma-separated format with a custom-built API to facilitate usage, and has been cleaned and documented. The data has a wide range of applications, including investigating energy demand patterns and drivers, modelling building performance, and undertaking Non-Intrusive Load Monitoring research.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 565
Author(s):  
Lucie Koštejnová ◽  
Jakub Ondráček ◽  
Petra Majerová ◽  
Martin Koštejn ◽  
Gabriela Kuncová ◽  
...  

Glucose belongs among the most important substances in both physiology and industry. Current food and biotechnology praxis emphasizes its on-line continuous monitoring and regulation. These provoke increasing demand for systems, which enable fast detection and regulation of deviations from desired glucose concentration. We demonstrated control of glucose concentration by feedback regulation equipped with in situ optical fiber glucose sensor. The sensitive layer of the sensor comprises oxygen-dependent ruthenium complex and preimmobilized glucose oxidase both entrapped in organic–inorganic polymer ORMOCER®. The sensor was placed in the laboratory bioreactor (volume 5 L) to demonstrate both regulations: the control of low levels of glucose concentrations (0.4 and 0.1 mM) and maintenance of the glucose concentration (between 2 and 3.5 mM) during stationary phase of cultivation of Saccharomyces cerevisiae. Response times did not exceed 6 min (average 4 min) with average deviation of 4%. Due to these regulation characteristics together with durable and long-lasting (≥2 month) sensitive layer, this feedback regulation system might find applications in various biotechnological processes such as production of low glucose content beverages.


2018 ◽  
Vol 4 (3) ◽  
pp. 25 ◽  
Author(s):  
Daniel Ferrández ◽  
Carlos Moron ◽  
Jorge Pablo Díaz ◽  
Pablo Saiz

ResumenEl actual Código Técnico de la Edificación (CTE) pone de manifiesto la necesidad de cubrir parte de la demanda energética requerida para el abastecimiento de agua caliente sanitaria y climatización de piscinas cubiertas mediante sistemas de aprovechamiento de la energía solar térmica. En este artículo se presenta una comparativa entre las dos principales tipologías de captadores solares térmicos que existen en el mercado: el captador de placa plana y el captador de tubo de vacío, atendiendo a criterios de fracción solar, diseño e integración arquitectónica. Todo ello a fin de discernir en qué circunstancias es más favorable el uso de uno u otro sistema, comparando los resultados obtenidos mediante programas de simulación con la toma de medidas in situ.AbstractThe current Technical Building Code (CTE) highlights the need to cover part of the energy demand required for the supply of hot water and heating of indoor swimming pools using solar thermal systems. This article presents a comparison between the two main types of solar thermal collectors that exist in the market: the flat plate solar collector and the vacuum tube solar collector, according to criteria of solar fraction, design and architectural integration. All of this in order to discern in what circumstances the use of one or the other system is more favourable, comparing the results obtained through simulation programs with the taking of measurements in situ.


2016 ◽  
Vol 861 ◽  
pp. 198-205
Author(s):  
Anton Pitonak ◽  
Martin Lopusniak

In the members states of the European Union, portion of buildings in the total consumption of energy represents 40%, and their portion in CO2 emissions fluctuates around 35%. The European Union is trying to protect the environment by reducing energy demand and releasing CO2 emissions into the air. Energy performance is the quantity of energy, which is necessary for heating and domestic hot water production, for cooling and ventilation and for lighting. Based on results of energy performance, individual buildings are classified into energy classes A to G. A global indicator (primary energy) is the decisive factor for final evaluation of the building. The new building must meet minimum requirements for energy performance, i.e. it must be classified to energy class A1 since 2016, and to energy class A0 since 2020. The paper analyses effect of the use of different resources of heat in a family house designed according to requirements valid since 2020, and its subsequent classification into an energy class.


2021 ◽  
Author(s):  
Rubén Vidal ◽  
Maarten W. Saaltink ◽  
Sebastià Olivella

<p>Aquifer Thermal Energy Storage (ATES) can help to balance energy demand and supply to make better use of infrastructures and resources. ATES consists of a pair or more wells that simultaneously inject or extract thermal energy into aquifers. The aim of ATES is to store the excess of energy during summer and to reuse it during winter, when there is an energy deficit. High-temperature Aquifer Thermal Energy Storage (HT-ATES) provides a good option to store water over 50°C, but it requires facing some problems, such as low efficiency recoveries and the uplift of the surface. Coupled thermo-hydro-mechanical (THM) modelling is a good tool to analyze the viability and cost effectiveness of the HT-ATES systems and understand the interaction of processes, such as heat flux, groundwater flow and ground deformation. We present the 3D THM modelling of a pilot HT-ATES system, inspired by one of the projects of HEATSTORE, which is a GEOTHERMICA ERA-NET co-funded project. The model aims to simulate the injection of hot water of 90°C in a central well and the extraction of water in four auxiliary wells during summer. In winter, the auxiliary wells inject water of 50°C and the central well extract water. The loading lasts longer than the unloading (8 months versus 4 months) and overall more heat is injected than extracted. We found that the system is more efficient in terms of energy recovery, the more years the system is operating. In the aquifer, both thermal loads and hydraulic loads have an important role in terms of displacements. At the surface, the vertical displacements are only a consequence of the hydraulic strains generated by the injection of water in the aquifer.</p>


Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 6026
Author(s):  
Sergio Gómez Melgar ◽  
Antonio Sánchez Cordero ◽  
Marta Videras Rodríguez ◽  
José Manuel Andújar Márquez

The construction sector is a great contributor to global warming both in new and existing buildings. Minimum energy buildings (MEBs) demand as little energy as possible, with an optimized architectural design, which includes passive solutions. In addition, these buildings consume as low energy as possible introducing efficient facilities. Finally, they produce renewable energy on-site to become zero energy buildings (ZEBs) or even plus zero energy buildings (+ZEB). In this paper, a deep analysis of the energy use and renewable energy production of a social dwelling was carried out based on data measurements. Unfortunately, in residential buildings, most renewable energy production occurs at a different time than energy demand. Furthermore, energy storage batteries for these facilities are expensive and require significant maintenance. The present research proposes a strategy, which involves rescheduling energy demand by changing the habits of the occupants in terms of domestic hot water (DHW) consumption, cooking, and washing. Rescheduling these three electric circuits increases the usability of the renewable energy produced on-site, reducing the misused energy from 52.84% to 25.14%, as well as decreasing electricity costs by 58.46%.


Resources ◽  
2019 ◽  
Vol 8 (2) ◽  
pp. 110 ◽  
Author(s):  
Camilla Tua ◽  
Laura Biganzoli ◽  
Mario Grosso ◽  
Lucia Rigamonti

The European packaging market is forecast to grow 1.9% annually in the next years, with an increasing use of returnable packages. In this context, it is important to assess the real environmental effectiveness of the packaging re-use practice in terms of environmental impacts. This life cycle assessment aims to evaluate the environmental performances of reusable plastic crates (RPCs), which are used for the distribution of 36% of fruit and vegetables in Italy. RPCs can be re-used several times after a reconditioning process, i.e., inspection, washing, and sanitization with hot water and chemicals. The analysis was performed considering 12 impact categories, as well as the cumulative energy demand indicator and a tailor-made water consumption indicator. The results show that when the RPCs are used for less than 20 deliveries, the impacts of the life cycle are dominated by the manufacturing stage. By increasing the number of deliveries, the contribution of the reconditioning process increases, reaching 30–70% of the overall impacts for 125 uses. A minimum of three deliveries of the RPCs is required in order to perform better than an alternative system where crates of the same capacity (but 60% lighter) are single-use. The same modeling approach can be used to evaluate the environmental sustainability of other types of returnable packages, in order to have a complete overview for the Italian context and other European countries.


2020 ◽  
Vol 160 ◽  
pp. 01004 ◽  
Author(s):  
Stanislav Chicherin ◽  
Lyazzat Junussova ◽  
Timur Junussov

Proper adjustment of domestic hot water (DHW) load structure can balance energy demand with the supply. Inefficiency in primary energy use prompted Omsk DH company to be a strong proponent of a flow controller at each substation. Here the return temperature is fixed to the lowest possible value and the supply temperature is solved. Thirty-five design scenarios are defined for each load deviation index with equally distributed outdoor temperature ranging from +8 for the start of a heating season towards extreme load at temperature of -26°C. All the calculation results are listed. If a flow controller is installed, the customers might find it suitable to switch to this type of DHW supply. Considering an option with direct hot water extraction as usual and a flow controller installed, the result indicates that the annual heat consumption will be lower once network temperatures during the fall or spring months are higher. The heat load profiles obtained here may be used as input for a simulation of a DH substation, including a heat pump and a tank for thermal energy storage. This design approach offers a quantitative way of sizing temperature levels in each DH system according to the listed methodology and the designer's preference.


Energies ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 3492 ◽  
Author(s):  
Crainz ◽  
Curto ◽  
Franzitta ◽  
Longo ◽  
Montana ◽  
...  

The design of multi-carrier energy systems (MESs) has become increasingly important in the last decades, due to the need to move towards more efficient, flexible, and reliable power systems. In a MES, electricity, heating, cooling, water, and other resources interact at various levels, in order to get optimized operation. The aim of this study is to identify the optimal combination of components, their optimal sizes, and operating schedule allowing minimizing the annual cost for meeting the energy demand of Pantelleria, a Mediterranean island. Starting from the existing energy system (comprising diesel generators, desalination plant, freshwater storage, heat pumps, and domestic hot water storages) the installation of solar resources (photovoltaic and solar thermal) and electrical storage were considered. In this way, the optimal scheduling of storage units injections, water desalination operation, and domestic hot water production was deduced. An energy hub model was implemented using MATLAB to represent the problem. All equations in the model are linear functions, and variables are real or integer. Thus, a mixed integer linear programming algorithm was used for the solution of the optimization problem. Results prove that the method allows a strong reduction of operating costs of diesel generators also in the existing configuration.


Sign in / Sign up

Export Citation Format

Share Document