SLEEP LOSS EFFECTS ON AFFECTIVE RESPONSES OF WOMEN AND MEN USING ECG CHARACTERISTICS

2017 ◽  
Vol 29 (05) ◽  
pp. 1750032 ◽  
Author(s):  
Ateke Goshvarpour ◽  
Atefeh Goshvarpour ◽  
Ataollah Abbasi

Sleep deprivation adversely affects the psychological and physiological functions, but little information about the effects of poor sleeping on the emotional responses of individuals are available. In the present study, the effect of one night insufficient sleep on the emotional responses to visual stimuli was appraised using electrocardiogram (ECG) measures. We also tested the hypothesis that men and women differ in affective response, considering the sleep quantity. ECG signals of university students (20 men and 20 women) were recorded while viewing affective pictures. Images were selected from the International Affective Picture System and categorized as happy, fear, sadness, and relax. The data were characterized using 14 time- and frequency-based features. The Wilcoxon statistical test was applied to examine significant differences between two groups of insufficient and normal sleep. A significant effect of ECG parameters was observed in deficient sleep on the emotional responses. Mode, RMS, and mean power show the largest effect size in all affective states. Among the affective states, the most significant differences between the two groups were perceived while watching sad and relaxed pictures. In addition, analysis of affective ECG measures in men and women distinctly revealed that lack of sleeping is more pronounced in men. Sleep is associated with the emotional responses. Our results confirmed the effect of gender on affective physiological reactions.

2008 ◽  
Vol 67 (1) ◽  
pp. 41-50 ◽  
Author(s):  
Frithjof Staude-Müller ◽  
Thomas Bliesener ◽  
Stefanie Luthman

This study tests whether playing violent video games leads to desensitization and increased cardiovascular responding. In a laboratory experiment, 42 men spent 20 min playing either a high- or low-violence version of a “first-person shooter” game. Arousal (heart rate, respiration rate) was measured continuously. After playing the game, emotional responses to aversive and aggressive stimuli - pictures from Lang, Bradley, and Cuthbert’s (1999) International Affective Picture System - were assessed with self-ratings and physiological measurement (skin conductance). Results showed no differences in the judgments of emotional responses to the stimuli. However, different effects of game violence emerged in the physiological reactions to the different types of stimulus material. Participants in the high-violence condition showed significantly weaker reactions (desensitization) to aversive stimuli and reacted significantly more strongly (sensitization) to aggressive cues. No support was found for the arousal hypothesis. Post-hoc analyses are used to discuss possible moderating influences of gaming experience and player’s trait aggressiveness in terms of the General Aggression Model ( Anderson & Bushman, 2001 ) and the Downward Spiral Model ( Slater, Henry, Swaim, & Anderson, 2003 ).


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Elisa Mejía-Mejía ◽  
James M. May ◽  
Mohamed Elgendi ◽  
Panayiotis A. Kyriacou

AbstractHeart rate variability (HRV) utilizes the electrocardiogram (ECG) and has been widely studied as a non-invasive indicator of cardiac autonomic activity. Pulse rate variability (PRV) utilizes photoplethysmography (PPG) and recently has been used as a surrogate for HRV. Several studies have found that PRV is not entirely valid as an estimation of HRV and that several physiological factors, including the pulse transit time (PTT) and blood pressure (BP) changes, may affect PRV differently than HRV. This study aimed to assess the relationship between PRV and HRV under different BP states: hypotension, normotension, and hypertension. Using the MIMIC III database, 5 min segments of PPG and ECG signals were used to extract PRV and HRV, respectively. Several time-domain, frequency-domain, and nonlinear indices were obtained from these signals. Bland–Altman analysis, correlation analysis, and Friedman rank sum tests were used to compare HRV and PRV in each state, and PRV and HRV indices were compared among BP states using Kruskal–Wallis tests. The findings indicated that there were differences between PRV and HRV, especially in short-term and nonlinear indices, and although PRV and HRV were altered in a similar manner when there was a change in BP, PRV seemed to be more sensitive to these changes.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yanfei Yang ◽  
Mingzhu Xu ◽  
Aimin Liang ◽  
Yan Yin ◽  
Xin Ma ◽  
...  

AbstractIn this study, a wearable multichannel human magnetocardiogram (MCG) system based on a spin exchange relaxation-free regime (SERF) magnetometer array is developed. The MCG system consists of a magnetically shielded device, a wearable SERF magnetometer array, and a computer for data acquisition and processing. Multichannel MCG signals from a healthy human are successfully recorded simultaneously. Independent component analysis (ICA) and empirical mode decomposition (EMD) are used to denoise MCG data. MCG imaging is realized to visualize the magnetic and current distribution around the heart. The validity of the MCG signals detected by the system is verified by electrocardiogram (ECG) signals obtained at the same position, and similar features and intervals of cardiac signal waveform appear on both MCG and ECG. Experiments show that our wearable MCG system is reliable for detecting MCG signals and can provide cardiac electromagnetic activity imaging.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3668
Author(s):  
Chi-Chun Chen ◽  
Shu-Yu Lin ◽  
Wen-Ying Chang

This study presents a noncontact electrocardiogram (ECG) measurement system to replace conventional ECG electrode pads during ECG measurement. The proposed noncontact electrode design comprises a surface guard ring, the optimal input resistance, a ground guard ring, and an optimal voltage divider feedback. The surface and ground guard rings are used to reduce environmental noise. The optimal input resistor mitigates distortion caused by the input bias current, and the optimal voltage divider feedback increases the gain. Simulated gain analysis was subsequently performed to determine the most suitable parameters for the design, and the system was combined with a capacitive driven right leg circuit to reduce common-mode interference. The present study simulated actual environments in which interference is present in capacitive ECG signal measurement. Both in the case of environmental interference and motion artifact interference, relative to capacitive ECG electrodes, the proposed electrodes measured ECG signals with greater stability. In terms of R–R intervals, the measured ECG signals exhibited a 98.6% similarity to ECGs measured using contact ECG systems. The proposed noncontact ECG measurement system based on capacitive sensing is applicable for use in everyday life.


2021 ◽  
Vol 11 (3) ◽  
pp. 1125
Author(s):  
Htet Myet Lynn ◽  
Pankoo Kim ◽  
Sung Bum Pan

In this report, the study of non-fiducial based approaches for Electrocardiogram(ECG) biometric authentication is examined, and several excessive techniques are proposed to perform comparative experiments for evaluating the best possible approach for all the classification tasks. Non-fiducial methods are designed to extract the discriminative information of a signal without annotating fiducial points. However, this process requires peak detection to identify a heartbeat signal. Based on recent studies that usually rely on heartbeat segmentation, QRS detection is required, and the process can be complicated for ECG signals for which the QRS complex is absent. Thus, many studies only conduct biometric authentication tasks on ECG signals with QRS complexes, and are hindered by similar limitations. To overcome this issue, we proposed a data-independent acquisition method to facilitate highly generalizable signal processing and feature learning processes. This is achieved by enhancing random segmentation to avoid complicated fiducial feature extraction, along with auto-correlation to eliminate the phase difference due to random segmentation. Subsequently, a bidirectional recurrent neural network (RNN) with long short-term memory (LSTM) deep networks is utilized to automatically learn the features associated with the signal and to perform an authentication task. The experimental results suggest that the proposed data-independent approach using a BLSTM network achieves a relatively high classification accuracy for every dataset relative to the compared techniques. Moreover, it exhibited a significantly higher accuracy rate in experiments using ECG signals without the QRS complex. The results also revealed that data-dependent methods can only perform well for specified data types and amendments of data variations, whereas the presented approach can also be considered for generalization to other quasi-periodical biometric signal-based classification tasks in future studies.


2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
Manab Kumar Das ◽  
Samit Ari

Classification of electrocardiogram (ECG) signals plays an important role in clinical diagnosis of heart disease. This paper proposes the design of an efficient system for classification of the normal beat (N), ventricular ectopic beat (V), supraventricular ectopic beat (S), fusion beat (F), and unknown beat (Q) using a mixture of features. In this paper, two different feature extraction methods are proposed for classification of ECG beats: (i) S-transform based features along with temporal features and (ii) mixture of ST and WT based features along with temporal features. The extracted feature set is independently classified using multilayer perceptron neural network (MLPNN). The performances are evaluated on several normal and abnormal ECG signals from 44 recordings of the MIT-BIH arrhythmia database. In this work, the performances of three feature extraction techniques with MLP-NN classifier are compared using five classes of ECG beat recommended by AAMI (Association for the Advancement of Medical Instrumentation) standards. The average sensitivity performances of the proposed feature extraction technique for N, S, F, V, and Q are 95.70%, 78.05%, 49.60%, 89.68%, and 33.89%, respectively. The experimental results demonstrate that the proposed feature extraction techniques show better performances compared to other existing features extraction techniques.


Author(s):  
SAURAV MANDAL ◽  
NABANITA SINHA

This study aims to present an efficient model for autodetection of cardiac arrhythmia by the diagnosis of self-affinity and identification of governing processes of a number of Electrocardiogram (ECG) signals taken from MIT-BIH database. In this work, the proposed model includes statistical methods to find the diagnosis pattern for detecting cardiac abnormalities which is useful for the computer aided system for arrhythmia detection. First, the Rescale Range (R/S) analysis has been employed for ECG signals to understand the scaling property of ECG signals. The value of Hurst exponent identifies the presence of abnormality in ECG signals taken for consideration with 92.58% accuracy. In this study, Higuchi method which deals with unifractality or monofractality of signals has been applied and it is found that unifractality is sufficient to detect arrhythmia with 91.61% accuracy. The Multifractal Detrended Fluctuation Analysis (MFDFA) has been used over the present signals to identify and confirm the multifractality. The nature of multifractality is different for arrhythmia patients and normal heart condition. The multifractal analysis is useful to detect abnormalities with 93.75% accuracy. Finally, the autocorrelation analysis has been used to identify the prevalent governing process in the present arrhythmic ECG signals and study confirms that all the signals are governed by stationary autoregressive methods of certain orders. In order to increase the overall efficiency, this present model deals with analyzing all the statistical features extracted from different statistical techniques for a large number of ECG signals of normal and abnormal heart condition. Finally, the result of present analysis altogether possibly indicates that the proposed model is efficient to detect cardiac arrhythmia with 99.3% accuracy.


2020 ◽  
Author(s):  
Prihatin Oktivasari ◽  
S Imam ◽  
Riandini ◽  
Amy Hamidah Salman ◽  
Freddy Haryanto ◽  
...  

2021 ◽  
pp. 1-11
Author(s):  
Najmeh Pakniyat ◽  
Mohammad Hossein Babini ◽  
Vladimir V. Kulish ◽  
Hamidreza Namazi

BACKGROUND: Analysis of the heart activity is one of the important areas of research in biomedical science and engineering. For this purpose, scientists analyze the activity of the heart in various conditions. Since the brain controls the heart’s activity, a relationship should exist among their activities. OBJECTIVE: In this research, for the first time the coupling between heart and brain activities was analyzed by information-based analysis. METHODS: Considering Shannon entropy as the indicator of the information of a system, we recorded electroencephalogram (EEG) and electrocardiogram (ECG) signals of 13 participants (7 M, 6 F, 18–22 years old) in different external stimulations (using pineapple, banana, vanilla, and lemon flavors as olfactory stimuli) and evaluated how the information of EEG signals and R-R time series (as heart rate variability (HRV)) are linked. RESULTS: The results indicate that the changes in the information of the R-R time series and EEG signals are strongly correlated (ρ=-0.9566). CONCLUSION: We conclude that heart and brain activities are related.


Sign in / Sign up

Export Citation Format

Share Document