Evaluation of Roofing Systems in Malaysia Based on MS 1553 BS 6399, EC1-1-4 and IS 875 Wind Codes

2014 ◽  
Vol 567 ◽  
pp. 577-582
Author(s):  
Kang Seavhai ◽  
S.P. Narayanan

This paper evaluates the performance of different roofing sheet systems for different roof types using four different codes namely MS 1553, EC1-1-4, IS 875 and BS 6399. The maximum roof pressures using different codes (MS 1553, EC1-1-4, IS 875 and BS 6399) on critical and general area of the different roof types considering buildings with non-dominant opening, dominant opening and canopies have been evaluated. The maximum recommended wind speed in MS 1553 namely 33.5 m/s has been used as the reference for the numerical comparison. The major differences in the codes include averaging time for wind speed, terrain, reference height, and pressure coefficients. The study examines the conservativeness or not of the codes if used in the Malaysian context, even though they have been developed for a different wind climate and region. Further, the results of static test on different steel roofing sheets used in Malaysia using AS 1562.1 available as the limit state wind pressure capacities in the technical brochures are compared with design wind pressures for critical and interior regions of the roof for different wind zones. The suitability of a particular roofing sheet system for a particular wind zone is then assessed.

2020 ◽  
Vol 2020 ◽  
pp. 1-24
Author(s):  
Fu-Bin Chen ◽  
Xiao-Lu Wang ◽  
Yun Zhao ◽  
Yuan-Bo Li ◽  
Qiu-Sheng Li ◽  
...  

High-rise buildings are very sensitive to wind excitations, and wind-induced responses have always been the key factors for structural design. Facade openings have often been used as aerodynamic measures for wind-resistant design of high-rise buildings to meet the requirement of structural safety and comfort. Obvious wind speed amplifications can also be observed inside the openings. Therefore, implementing wind turbines in the openings is of great importance for the utilization of abundant wind energy resources in high-rise buildings and the development of green buildings. Based on numerical simulation and wind tunnel testing, the wind loads and wind speed amplifications on high-rise buildings with openings are investigated in detail. The three-dimensional numerical simulation for wind effects on high-rise building with openings was firstly carried out on FLUENT 15.0 platform by SST k − ε model. The mean wind pressure coefficients and the wind flow characteristics were obtained. The wind speed amplifications at the opening were analyzed, and the distribution law of wind speed in the openings is presented. Meanwhile, a series of wind tunnel tests were conducted to assess the mean and fluctuating wind pressure coefficients in high-rise building models with various opening rates. The variation of wind pressure distribution at typical measuring layers with wind direction was analyzed. Finally, the wind speed amplifications in the openings were studied and verified by the numerical simulation results.


2011 ◽  
Vol 94-96 ◽  
pp. 1026-1030
Author(s):  
Yue Ming Luo ◽  
Yue Yin ◽  
Xi Liang Liu

Due to the increasing of wind disaster, structural wind engineering arouses more and more attention recently, with rapid development on spatial structure and continuous innovation of structural style. The main purpose of structural wind engineering is to calculate the wind pressure coefficients of structure. In this paper, the numerical wind tunnel method (NWTM), based on the Computational Fluid Dynamics (CFD), is applied to study wind load. The wind pressure coefficients of reticulated spherical shell with the 4.6m high wall were first determined, using the NWTM. The results are then compared with the wind tunnel test (WTT) and good agreement is found. The feasibility and reliability of NWTM were then verified. As the second example, NWTM is carried out to predict wind-induced pressure on reticulated spherical shell without wall. Further the distribution behavior of wind pressures on this kind of structures is discussed which could provide professionals the reference for the design of structure.


2013 ◽  
Vol 639-640 ◽  
pp. 515-522
Author(s):  
Yong Gui Li ◽  
Q.S. Li

Wind tunnel test of 1:500 rigid model of tall building with atrium was carried out. Based on the experimental results, characteristics of wind pressures on atrium facades and wind loads on the structure were investigated in detail. The results show that the formation of flow separation on the building top plays a critical role in the generation of wind pressures on the atrium facades. Meanwhile, wind pressure coefficient distributions on the atrium facades are found to be relatively uniform. Moreover, the horizontal and vertical correlations of pressure coefficient exhibit high at most locations on atrium facades. With the increasing of the opening ratio, the mean wind pressure coefficients first decreased and then stabilized, and the fluctuating wind pressure coefficients first decreased and then increased. A design guideline for the wind-resistant design of atrium facades was proposed, and the results predicted by the proposed guideline were in good agreement with those from the wind tunnel tests, indicating that the proposed guideline can be used in engineering applications. When the opening ratio is no more than 5.33%, the effect of the facade pressures within the atrium on the wind loads on the structure can be ignored. For such cases, the wind-resistant design for a tall building with atrium can refer to that of a similar shape tall building without atrium.


Author(s):  
Neelam Rani ◽  
Ashok Kumar Ahuja

The present study gives information related to wind pressure distribution on single span and multi span circular canopy roofs. The experiments are carried out in an open circuit boundary layer wind tunnel. Wind pressure is measured on both upper and lower roof surfaces of circular canopy roof model made of Perspex sheet. Models are tested under varying wind incidence angles between 0° and 90° at an interval of 15° on isolated model and 0° to 180° at an interval of 30° on models with multi-span canopy roof. Values of mean wind pressure coefficients are evaluated from the measured values of wind pressures. Results of the study are presented in the form of contours, cross sectional variation and face average values of pressure coefficients. The results of the study are of great use for the structural designers for designing circular canopy roofs.


Author(s):  
Astha Verma ◽  
Ashok Kumar Ahuja

Present paper describes details of the experimental study carried out on the models of industrial building with north-light roof in order to generate the information about wind pressure distribution on it. The models are tested in a closed circuit boundary layer wind tunnel to measure values of wind pressures on roof surface. Four cases namely one, two, three and four spans are considered. The side of Perspex sheet model in case of multi-span study places plywood models. Wind is made to hit the models at 13 wind incidence angles from 0° to 180° at an interval of 15°. Values of mean wind pressure coefficients are evaluated from the measured values of wind pressures and contours are plotted.


2008 ◽  
Vol 400-402 ◽  
pp. 935-940 ◽  
Author(s):  
Ying Ge Wang ◽  
Zheng Nong Li ◽  
Bo Gong ◽  
Qiu Sheng Li

Heliostat is the key part of Solar Tower power station, which requires extremely high accuracy in use. But it’s sensitive to gust because of its light structure, so effect of wind load should be taken into account in design. Since structure of heliostat is unusual and different from common ones, experimental investigation on rigid heliostat model using technology of surface pressure mensuration to test 3-dimensional wind loads in wind tunnel was conducted. The paper illustrates distribution and characteristics of reflector’s mean and fluctuating wind pressure while wind direction angle varied from 0° to 180° and vertical angle varied from 0° to 90°. Moreover, a finite element model was constructed to perform calculation on wind-induced dynamic response. The results show that the wind load power spectral change rulers are influenced by longitudinal wind turbulence and vortex and are related with Strouhal number; the fluctuating wind pressures between face and back mainly appear positive correlation, and the correlation coefficients at longitudinal wind direction are smaller than those at lateral direction; the fluctuating wind pressures preferably agree with Gaussian distribution at smaller vertical angle and wind direction angle. The wind-induced response and its spectrums reveal that: when vertical angle is small, the background responsive values of reflector’s different parts are approximately similar; in addition, multi-phased resonant response occurring at the bottom. With the increase of , airflow separates at the near side and reunites at the other, as produces vortex which enhances dynamic response at the upper part.


2021 ◽  
Vol 11 (15) ◽  
pp. 7121
Author(s):  
Shouke Li ◽  
Feipeng Xiao ◽  
Yunfeng Zou ◽  
Shouying Li ◽  
Shucheng Yang ◽  
...  

Wind tunnel tests are carried out for the Commonwealth Advisory Aeronautical Research Council (CAARC) high-rise building with a scale of 1:400 in exposure categories D. The distribution law of extreme pressure coefficients under different conditions is studied. Probability distribution fitting is performed on the measured area-averaged extreme pressure coefficients. The general extreme value (GEV) distribution is preferred for probability distribution fitting of extreme pressure coefficients. From the comparison between the area-averaged coefficients and the value from GB50009-2012, it is indicated that the wind load coefficients from GB50009-2012 may be non-conservative for the CAARC building. The area reduction effect on the extreme wind pressure is smaller than that on the mean wind pressure from the code. The recommended formula of the area reduction factor for the extreme pressure coefficient is proposed in this study. It is found that the mean and the coefficient of variation (COV) for the directionality factors are 0.85 and 0.04, respectively, when the orientation of the building is given. If the uniform distribution is given for the building’s orientation, the mean value of the directionality factors is 0.88, which is close to the directionality factor of 0.90 given in the Chinese specifications.


2013 ◽  
Author(s):  
Robel Kiflemariam ◽  
Cheng-Xian Lin

Mean wind pressure coefficient (Cp) is one of the major input data for natural ventilation study using building energy simulation approach. Due to their importance, they need to be accurately determined. In current engineering practice, tables and analytical Cp models only give mostly averaged results for simpler models and configurations. Considering the limitation of tables and analytical models, Computational Fluid Dynamics (CFD) could provide a means for an accurate and detailed assessment of Cp. In this paper, we make use of a relatively high resolution, detailed experiments done at Florida Intentional University to validate a CFD modeling of the pressure coefficients Cp. The results show that existing CFD model has a good agreement with experimental results and gives important information of distribution of Cp values over the surface. The local values of the Cp are investigated. In addition, the CFD derived Cp and discharge coefficient (Cd) values are utilized in semi-analytical ventilation models in order to get a more accurate value of ventilation rates.


Author(s):  
V. P. Evstigneev ◽  
◽  
N. A. Lemeshko ◽  
V. A. Naumova ◽  
M. P. Evstigneev ◽  
...  

The paper deals with assessing an impact of wind climate change on the wind energy potential of the Azov and Black Sea coast region. A lower estimate of operating time for wind power installation and a potential annual energy output for the region are given for the case of Vestas V117-4.2MW. Calculation has been performed of a long-term mean wind speed for two adjacent climatic periods (1954–1983 and 1984–2013) based on data from meteorological stations of the Black and Azov Sea region. The results show a decrease in wind speed at all meteorological stations except for Novorossiysk. The wind climate change is confirmed by comparing two adjoined 30-year periods and by estimating linear trends of the mean annual wind speed for the period 1954–2013, which are negative and significant for almost all meteorological stations in the region (α = 1 %). The trend values were estimated by the nonparametric method of robust linear smoothing using the Theil – Sen function. In the present study, the uncertainty of wind energy resource induced by a gradual wind climate change is estimated for perspective planning of this branch of energy sector. Despite the observed trends in the wind regime, average wind speeds in the Azov and Black Sea region are sufficient for planning the location of wind power plants.


Sign in / Sign up

Export Citation Format

Share Document