Model for Heat Pipe Position Optimization of Transformers Cooled by Heat Pipes

2011 ◽  
Vol 347-353 ◽  
pp. 3765-3771
Author(s):  
Xi Zhang ◽  
Jun Bao Yang ◽  
Min Deng

In the view of heat pipe position optimization of transformers cooled by heat pipes, using the thermal equilibrium equation and the empirical formula of heat transfer coefficient of the evaporation and condensation section, applying Newton Iteration, computing the optimal condensation section area, the optimal computation of heat pipes’ position is implemented and the model of heat pipe position optimization of transformers cooled by heat pipes is set up.

2018 ◽  
Vol 1 (1) ◽  
pp. 298-304
Author(s):  
Maroua Mekcem

Given the high efficiency of heat pipes as heat transfer devices, which work with phase changing principle (evaporation and condensation) and without requiring any external energy input, the heat pipes have been utilized for many years in several areas. However, heat transfer in heat pipes is limited by physical phenomena which appear during its operation, called heat pipe limitations; these can limit and reduce its performance. At this state, the use of nanofluids instead of conventional fluids come a solution after that Choi and Eastman (1995) confirmed the feasibility of enhancing the thermal conductivity of fluids by adding nanoparticles. This paper represents a general description of heat pipes, including a brief historical perspective, principle of operation and explanation of main heat transfer limitations. The work shows the contribution of nanofluids in pushing back the heat pipe limitations.


Author(s):  
Jiaxiang Yang ◽  
Jiancai Wang ◽  
Chuntian Chen ◽  
Changsheng Yu

A heat pipe model of electrohydrodynamical (EHD) enhancement heat transfer has been designed and made. The insulating liquid was selected as working fluid and the copper wire whose diameter was 1mm was used as the high voltage electrode. The temperature in the inlet and outlet of both the vaporization section and the condensation section, the saturation vapor pressure inside this model were measured respectively under different applied dc voltage and different tilt angle, that is, the vaporization section was placed higher than the condensation section. The experiment results indicate that the circumfluence between the condensation section and the vaporization section was improved with the increase of the applied dc voltage. Such EHD enhancement heat transfer technology can be practically employed in the heat transfer engineering, and has some reference values for the investigation of heat pipes used in the case of anti-gravity.


Author(s):  
Tarigonda Hari Prasad ◽  
Pol Reddy Kukutla ◽  
P. Mallikarjuna Rao ◽  
R. Meenakshi Reddy

Pulsating heat pipes (PHP) receives heat from the working fluid distributes itself naturally in the form of liquid–vapor system, i.e., receiving heat from one end and transferring it to other end by a pulsating action of the liquid–vapor system. Pulsating heat pipes have more advantages than other heat pipes. The problem identified is, to calculate the performance of the pulsating heat pipes with respect to different inclinations using various parameters. In this paper, experiment on performance of closed single loop pulsating heat pipe (CLPHP) using water as a working fluid is considered. The parameters such as thermal resistance (Rth), heat transfer coefficient (h), and variation of temperature with respect to time for the given input at different inclinations such as 0°, 45°, and 90° are taken for the present work. Water is used as the working fluid and is subjected to 50% filling ratio and vacuumed at a pressure of 2300Pa. The performance is calculated at different inclinations of the CLPHP with single turn/loop. The factors such as heat transfer coefficient, thermal resistance, time taken for heating the pulsating heat pipe with the given input are calculated. Finally, it has been concluded that is preferable orientation for PHP and it was found be at vertical orientation i.e., at 90° inclination, because more pulsating action is taken place at this inclination and henceforth, heat transfer rate is faster at this inclination.


2021 ◽  
Vol 11 (9) ◽  
pp. 4100
Author(s):  
Rasa Supankanok ◽  
Sukanpirom Sriwong ◽  
Phisan Ponpo ◽  
Wei Wu ◽  
Walairat Chandra-ambhorn ◽  
...  

Evacuated-tube solar collector (ETSC) is developed to achieve high heating medium temperature. Heat transfer fluid contained inside a copper heat pipe directly affects the heating medium temperature. A 10 mol% of ethylene-glycol in water is the heat transfer fluid in this system. The purpose of this study is to modify inner structure of the evacuated tube for promoting heat transfer through aluminum fin to the copper heat pipe by inserting stainless-steel scrubbers in the evacuated tube to increase heat conduction surface area. The experiment is set up to measure the temperature of heat transfer fluid at a heat pipe tip which is a heat exchange area between heat transfer fluid and heating medium. The vapor/ liquid equilibrium (VLE) theory is applied to investigate phase change behavior of the heat transfer fluid. Mathematical model validated with 6 experimental results is set up to investigate the performance of ETSC system and evaluate the feasibility of applying the modified ETSC in small-scale industries. The results indicate that the average temperature of heat transfer fluid in a modified tube increased to 160.32 °C which is higher than a standard tube by approximately 22 °C leading to the increase in its efficiency by 34.96%.


Open Physics ◽  
2020 ◽  
Vol 18 (1) ◽  
pp. 751-760
Author(s):  
Lei Lei

AbstractTraditional testing algorithm based on pattern matching is impossible to effectively analyze the heat transfer performance of heat pipes filled with different concentrations of nanofluids, so the testing algorithm for heat transfer performance of a nanofluidic heat pipe based on neural network is proposed. Nanofluids are obtained by weighing, preparing, stirring, standing and shaking using dichotomy. Based on this, the heat transfer performance analysis model of the nanofluidic heat pipe based on artificial neural network is constructed, which is applied to the analysis of heat transfer performance of nanofluidic heat pipes to achieve accurate analysis. The experimental results show that the proposed algorithm can effectively analyze the heat transfer performance of heat pipes under different concentrations of nanofluids, and the heat transfer performance of heat pipes is best when the volume fraction of nanofluids is 0.15%.


2021 ◽  
Vol 68 (1) ◽  
Author(s):  
R. Vidhya ◽  
T. Balakrishnan ◽  
B. Suresh Kumar

AbstractNanofluids are emerging two-phase thermal fluids that play a vital part in heat exchangers owing to its heat transfer features. Ceramic nanoparticles aluminium oxide (Al2O3) and silicon dioxide (SiO2) were produced by the sol-gel technique. Characterizations have been done through powder X-ray diffraction spectrum and scanning electron microscopy analysis. Subsequently, few volume concentrations (0.0125–0.1%) of hybrid Al2O3–SiO2 nanofluids were formulated via dispersing both ceramic nanoparticles considered at 50:50 ratio into base fluid combination of 60% distilled water (W) with 40% ethylene glycol (EG) using an ultrasonic-assisted two-step method. Thermal resistance besides heat transfer coefficient have been examined with cylindrical mesh heat pipe reveals that the rise of power input decreases the thermal resistance and inversely increases heat transfer coefficient about 5.54% and 43.16% respectively. Response surface methodology (RSM) has been employed for the investigation of heat pipe experimental data. The significant factors on the various convective heat transfer mechanisms have been identified using the analysis of variance (ANOVA) tool. Finally, the empirical models were developed to forecast the heat transfer mechanisms by regression analysis and validated with experimental data which exposed the models have the best agreement with experimental results.


1968 ◽  
Vol 90 (4) ◽  
pp. 547-552 ◽  
Author(s):  
E. K. Levy

A one-dimensional analysis of a compressible vapor flowing within the evaporator section of a heat pipe is presented. Comparisons between the theoretical results and existing heat pipe data show that the presence of gasdynamic choking can limit the heat transfer capacity of a heat pipe operating at sufficiently low vapor pressures.


2021 ◽  
Vol 2119 (1) ◽  
pp. 012088
Author(s):  
A. A. Litvintceva ◽  
N. I. Volkov ◽  
N. I. Vorogushina ◽  
V. A. Moskovskikh ◽  
V. V. Cheverda

Abstract Heat pipes are a good solution for temperature stabilization, for example, of microelectronics, because these kinds of systems are without any moving parts. Experimental research of the effect of operating parameters on the heat transfer in a cylindrical heat pipe has been conducted. The effect of the working fluid properties and the porous layer thickness on the heat flux and temperature difference in the heat pipe has been investigated. The temperature field of the heat pipe has been investigated using the IR-camera and K-type thermocouples. The data obtained by IR-camera and K-type thermocouples have been compared. It is demonstrated the power transferred from the evaporator to the condenser is a linear function of the temperature difference between them.


Author(s):  
Alberto Mucci ◽  
Foster Kwame Kholi ◽  
Man Yeong Ha ◽  
Jason Chetwynd-Chatwin ◽  
June Kee Min

Abstract The Pulsating Heat Pipe (PHP) is a promising device in the family of heat pipes. With no need for a wick, they exhibit a high heat transfer to weight ratio. Moreover, the wickless design removes limits commonly associated with conventional heat pipes, increasing the maximum power transfer per single heat pipe. These peculiarities make it an ideal candidate for many high power applications. Nonetheless, there is though only partial knowledge on the driving mechanism, which restricts prediction accuracy. Most Pulsating Heat Pipe studies rely on experiments to test configurations, while simulations usually depend on semi-empirical correlations or adaptations of reduced theoretical models. Experiments provide detailed data for a particular geometry in lab fixed conditions, but it offers limited flexibility to test alternative configurations. Semi-empirical models use previous experimental data to create non-dimensional formulations. Though approaching an increased set of conditions, correlations apply with reasonable accuracy only to a small range, outside of which the prediction ability progressively falls. High order numerical analysis such as Computational Fluid Dynamics (CFD) modeling could potentially provide full visualization, but due to the complex flow behavior, previous studies used this method only in simple configurations with a small number of turns. The present research will expand the potential of this modeling technique by presenting the CFD analysis of a complex Pulsating Heat Pipe configuration. The importance of this study lies in the fact that this configuration, with a number of turns greater than a critical parameter, shows a reduced sensitivity to gravity and is therefore particularly important for applications where restrictions on installations make the positioning sub-optimal. The research simulates using a CFD commercial software a two-dimensional Pulsating Heat Pipe with sixteen turns. The heat pipe, with a 2 mm internal diameter, is filled with water at 50% of mass. To visualize the oscillation pattern of liquid and vapor slugs and plugs inside the Pulsating Heat Pipe, the model performs a transient analysis on the device. A Volume of Fluid (VOF) solver for multiphase analysis, coupled with the Lee model for evaporation and condensation mass transfer, calculates the interactions between the liquid and the gas phase inside the tube. The study follows the geometric and operational conditions from previous experiments. The analysis regards a Pulsating Heat Pipe operating in a vertical position with the condenser section placed in the upper sector. During the initial operations, the system flow distribution fluctuates between different flow modes as the fluid slugs and plugs structure forms. After stabilizing the heat transfer results well agree with the tested values. Moreover, the increased resolution allows us to fully visualize the internal operation, retrieving additional information on the temperature and ratio of liquid and gas phase along the heat pipe.


Sign in / Sign up

Export Citation Format

Share Document