The Shear and Durability of CFRP Reinforced Concrete Beams

2011 ◽  
Vol 368-373 ◽  
pp. 1500-1504
Author(s):  
Ruo Dong Ge ◽  
Zheng Zhuo Yin ◽  
Ji Hong Zhang

At present, the research on the performance of the shear and durability of CFRP reinforced concrete beams is few, the destruction of the curved and scissor section is often much subtle and suddenly. Based on the experimental investigation on the durableness of the CFRP concrete beams which has been shear reinforced and non-reinforced in the chloride ion erode, a comparative analysis on the fissure development, deflection, electrochemistry index and strain of the concrete beam were given under load. The results indicate that carbon fiber could limit the fissure development efficiently, and there were not the shear failure after loading, the beams with carbon could improve its shear capacity and durability efficiently, But The increase of durability is more depends on the reinforcement way.

2018 ◽  
Vol 4 (7) ◽  
pp. 1501 ◽  
Author(s):  
Ali Ammar Hameed ◽  
Mohannad Husain Al-Sherrawi

The shear failure in a concrete beam is a brittle type of failure. The addition of steel fibers in a plain concrete mix helps to bridge and restrict the cracks formed in the brittle concrete under applied loads, and enhances the ductility of the concrete. In this research an attempt was made to investigate the behavior and the ultimate shear strength of hooked end steel fiber reinforced concrete beams without traditional shear reinforcement. Four simply-supported reinforced concrete beams with a shear span-to-depth ratio of about 3.0 were tested under two-point loading up to failure. Steel fibers volumetric fractions that used were 0.0, 0.5, 0.75 and 1.0%. Test results indicated that using 1.0% volume fraction of hooked steel fiber led to exclude shear failure and enhanced the use of steel fibers as shear reinforcement in concrete beams. The results also showed that a concrete beam with hooked steel fiber provided higher post-flexural-cracking stiffness, an increase in the shear capacity and energy absorption and an increase in the maximum concrete and steel reinforcement strains.


2014 ◽  
Vol 584-586 ◽  
pp. 899-903
Author(s):  
Wei Chen ◽  
Xiang Peng Li ◽  
Ting Ting Chen ◽  
Xiao Yang Wang ◽  
Chao Chao Ma

In order to research the influence of the shear capacity of reinforced concrete beam with the incorporation of basalt fiber, four basalt fiber reinforced concrete beams with parameters of length and volume ratio were designed and made. The fiber lengths were 12mm and 30mm, and the volume ratios were 1‰ and 2‰. The test data of basalt fiber reinforced concrete was obtained through the shear experiments and comparison with the common reinforced concrete beam. The results of the experiment show that the cracking load of the basalt fiber reinforced concrete beam increase obviously with the growing of fiber characteristic parameters, and effectively reduce the diagonal crack width.


2020 ◽  
Author(s):  
◽  
Hoosen Ahmed Jajbhay

Research to accurately predict the shear capacity of reinforced concrete beams without shear reinforcement has been ongoing since the early 20th century. Aggregate interlock of the coarse aggregates at the shear crack interface is one of the internal mechanisms of shear transfer and a major contributor to the shear capacity of slender beams. It is plausible, therefore, to investigate if the coarse aggregate itself influences the shear capacity of a concrete beam. The influence of the type of coarse aggregate on the shear capacity of beams without shear reinforcement was investigated in this study. From the literature study an understanding of the properties of coarse aggregates was gained, the internal mechanisms of shear transfer in reinforced concrete beams without shear reinforcement were determined, and the parameters influencing shear strength were identified. Based on this information an experimental program was designed. Eighteen reinforced concrete beams without shear reinforcement were cast. The beams were cast from three different types of coarse aggregates commonly used in the Durban area, i.e., dolerite, quartzite and tillite. For each type of coarse aggregate two variations were tested, i.e., 13 mm and 19 mm maximum aggregate sizes. For each size of coarse aggregate, three concrete strengths were tested. The beams were loaded in a beam press, by applying an increasing point load offset from midspan to induce cracking on the shorter side, until shear failure of the beam occurred. For the three concrete strengths, beams cast from dolerite had the highest shear capacity while beams cast from tillite had less shear capacity than beams cast from quartzite coarse aggregate. Furthermore, beams cast from 13 mm maximum size coarse aggregate had higher shear capacity than beams cast from 19 mm aggregate. The conclusion may be drawn that the type and size of coarse aggregate does influence the shear strength of a reinforced concrete beam without shear reinforcement.


2015 ◽  
Vol 744-746 ◽  
pp. 283-287
Author(s):  
Can Liu

Inner transverse prestressed bars were used to enhance the shear capacity of concrete beams in this paper, which can be used in transformer beams to reduce the sectional size. Two transversely prestressed one ordinary concrete beams were tested and calculated by finite element method, and the following conclusions can be drawn: (a)The shear capacity of transversely prestressed concrete beam increase rapidly with the increase of the prestressing force level, which means that prestressing force level has a great influence on the shear capacity of transversely prestressed concrete beam. (b) The transverse prestressing bars can efficiently enhance the anti-crack performance of the reinforced concrete beams.


2018 ◽  
Vol 183 ◽  
pp. 02038
Author(s):  
Yingqian Fu ◽  
Xinlu Yu ◽  
Xinlong Dong ◽  
Fenghua Zhou

This paper presents an experimental program of reinforced concrete beam without stirrups tested by impact three-point-bending under different initial velocity (drop height). As the results shown, for the static events, the failure mode is bending firstly, and then translates to shearing. the longitudinal reinforcements play an important role for the increasing of loading during bending stage. For the impact events, reinforced concrete beams failed in a flexural failure model at slow rates of loading and in shear failure model at high impact loading rate relatively. Moreover, the shear failure and bending failure have developed during the peak stage of Force-deflection curves. That is different with the emergence sequence of cracks under static tests. So the mechanical parameters of peak stage should be considered for the resistance of concrete beam under impact loading.


2011 ◽  
Vol 368-373 ◽  
pp. 108-113
Author(s):  
Can Liu ◽  
Bo Wu ◽  
Kai Yan Xu

This paper presents a method that using inner transverse prestressing bars to enhance the shear capacity of concrete beams, which can be used in new transformer beams to decrease the sectional dimensions. Four transversely prestressed concrete beams and one ordinary reinforced concrete beam were tested. The nonlinear finite element method was applied to analyze them, and the following conclusions can be drawn: (a) The transverse prestressing bars can efficiently increase the shear capacity and failure load of the reinforced concrete beam, the improvement effect is more obvious when exerting the prestressing force on them properly. (b) On the whole, the simulated load-deflection relationships and failure loads of the five specimens agree well with the corresponding tested load-deflection relationships and failure loads. It indicated that the FE models used in this paper predict the structural behavior of the transversely prestressed concrete beams satisfactorily. (c) From the contour of first principal stress, it can be seen that the transverse prestressing bars can efficiently enhance the shear crack resistance of the reinforced concrete beams, if the area of transversely prestressing bars is almost same, the transverse bars with smaller diameter and smaller spacing will be better. It agrees well with the test results.


2014 ◽  
Vol 578-579 ◽  
pp. 164-167 ◽  
Author(s):  
Peng Li ◽  
Xian Tang Zhang ◽  
Ming Ping Wang

To investigate the influence of shear span ratio for the shear behavior of reinforced concrete beam with HRBF500 high strength rebars as stirrups, an experiment was carried out, which included 8 simply supported beams with HRBF500 rebars as stirrups. Under concentrated loads, the crack, deflection, strain of rebars, bearing capacity and failure mode are observed under different shear span ratios. Some comparisons are made between test results and calculated outcome. It shows that the shear span ratio has very important influent on the shear behavior of reinforced concrete beam with HRBF500 high strength bars as stirrups. Formula in code for design of concrete structures can be used to calculate its shear capacity with enough safety.


Sign in / Sign up

Export Citation Format

Share Document