Purification Effect of Lolium multiflorum Ecological Floating Beds System in Urban Malodorous River at Low Temperature

2012 ◽  
Vol 518-523 ◽  
pp. 2686-2689
Author(s):  
Yu Hong Chai ◽  
Wen Yao Yan ◽  
Ming Xin Wang

An ecological floating beds system was constructed to treat natural urban malodorous river in Changzhou at low temperature. Taking Lolium multiflorum as an example of water plant, the characteristics and contribution of its uptake to total nitrogen (TN), NH4+-N, total phosphorus (TP) and chemical oxygen demand (CODMn) in the system were studied in a period of 80 days. Significant growth of the plant Lolium multiflorum was observed with total biomass ranging from 53 g to 785 g, and the highest growth rates were 8.82 and 9.23 for biomass of above water and under water part, respectively. Different concentrations of TN, NH4+-N, TP and COD were found between in the floating beds and out the floating beds. The highest removal rates of TN, NH4+-N, TP and CODMn using Lolium multiflorum ecological floating beds system were 16.8%, 33.0%,10.8% and 17.8%, respectively. The purification effect of ecological floating beds shows it can be well applied to cleaning natural rivers at low temperatures.

Water ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 21
Author(s):  
Ilaria Piccoli ◽  
Giuseppe Virga ◽  
Carmelo Maucieri ◽  
Maurizio Borin

Constructed wetlands (CWs) represent a green technology for digestate liquid fraction (DLF) treatment. However, previous research has warned about their performance when treating wastewater with high suspended solid and organic loads. In addition, the high NH4-N concentration typical of this wastewater can compromise vegetation establishment and activity. In view of this, a digestate pretreatment is needed. This study aimed to test the performance of filters filled with recovery materials, such as brick and refractory material, for DLF pretreatment. The effect on DLF physical (electrical conductivity, pH, dissolved oxygen, and temperature) and chemical (total nitrogen, ammonia–nitrogen, nitrate–nitrogen, total phosphorus, soluble phosphorus, and chemical oxygen demand) characteristics was monitored during eight weekly cycles. The effect of filtration on total nitrogen and ammonia–nitrogen removal began after about one month of loading, suggesting that an activation period is necessary for bacteria. For effective N removal, the presence of multiple digestate recirculations per day through the filters appears mandatory to guarantee the alternation of nitrification and denitrification conditions. For P removal, filling material particle size appeared to be more important than its composition. Unclear performances were observed considering chemical oxygen demand. Further studies on filling media and microbial community interactions, and the long-term efficiency of filters, are desirable.


Author(s):  
Isabela Pires da Silva ◽  
Gabriela Barbosa da Costa ◽  
João Gabriel Thomaz Queluz ◽  
Marcelo Loureiro Garcia

   This study evaluated the effect of hydraulic retention time on chemical oxygen demand (COD) and total nitrogen (TN) removal in an intermittently aerated constructed wetlands. Two horizontal subsurface-flow constructed wetlands were used: one without aeration and the other aerated intermittently (1 hour with aeration/7 hours without aeration). Both systems were evaluated treating domestic wastewater produced synthetically. The flow rate into the two CWs was 8.6 L day-1 having a hydraulic retention time of 3 days. The results show that the intermittently aerated constructed wetland were highly efficient in removing COD (98.25%), TN (83.60%) and total phosphorus (78.10%), while the non-aerated constructed wetland showed lower efficiencies in the removal of COD (93.89%), TN (48.60%) and total phosphorus (58.66). These results indicate, therefore, that intermittent aeration allows the simultaneous occurrence of nitrification and denitrification processes, improving the removal of TN in horizontal subsurface-flow constructed wetlands. In addition, the use of intermittent aeration also improves the performance of constructed wetlands in removing COD and total phosphorus.


2013 ◽  
Vol 12 (1) ◽  
pp. 196-209 ◽  
Author(s):  
H. S. Lim ◽  
L. Y. Lee ◽  
S. E. Bramono

This paper examines the impact of community-based water treatment systems on water quality in a peri-urban village in Yogyakarta, Indonesia. Water samples were taken from the wastewater treatment plants (WWTPs), irrigation canals, paddy fields and wells during the dry and wet seasons. The samples were tested for biological and chemical oxygen demand, nutrients (ammonia, nitrate, total nitrogen and total phosphorus) and Escherichia coli. Water quality in this village is affected by the presence of active septic tanks, WWTP effluent discharge, small-scale tempe industries and external sources. We found that the WWTPs remove oxygen-demanding wastes effectively but discharged nutrients, such as nitrate and ammonia, into irrigation canals. Irrigation canals had high levels of E. coli as well as oxygen-demanding wastes. Well samples had high E. coli, nitrate and total nitrogen levels. Rainfall tended to increase concentrations of biological and chemical oxygen demand and some nutrients. All our samples fell within the drinking water standards for nitrate but failed the international and Indonesian standards for E. coli. Water quality in this village can be improved by improving the WWTP treatment of nutrients, encouraging more villagers to be connected to WWTPs and controlling hotspot contamination areas in the village.


2012 ◽  
Vol 66 (10) ◽  
pp. 2243-2250 ◽  
Author(s):  
Wen-yi Dong ◽  
Xian-bing Zhang ◽  
Hong-jie Wang ◽  
Fei-yun Sun ◽  
Tong-zhou Liu

Three parallel biological anoxic filters (BaFs) were operated to investigate the denitrification kinetics of methanol, brewery wastewater and bakery wastewater. The experiment was conducted within the temperature range of 15–20 °C, with an influent nitrate and carbon dosage of 30 mg/L and 150 mg COD/L (COD: chemical oxygen demand). The denitrification efficiencies of brewery wastewater, bakery wastewater and methanol were 84, 66 and 74%, specific denitrification rates were 1.44, 1.11 and 1.24 kg NO3-N/m3 d, and total nitrogen (TN) removal rates were 74, 62 and 66%, respectively. The volatile attached solid (VAS) tests reveal that methanol has the minimum net biomass yield, so it needs the least carbon to nitrogen (expressed in COD to nitrate, C/N) ratio for complete denitrification. While the brewery wastewater and bakery wastewater need higher C/N ratio to remove all nitrate nitrogen, and they both may need pretreatment to remove phosphate when used as external carbon sources.


2016 ◽  
Author(s):  
◽  
Mathews Simon Mthembu

Many households in developing countries are still without proper sanitation systems. The problems are even more prevalent in rural communities where there are no septic systems in place for the treatment of wastewater. This has resulted in the urgent need for the development and implementation of innovative wastewater treatment systems that are inexpensive, environmental friendly and are able to reduce contaminants to levels that pose no harm to the communities. Constructed rhizofiltration systems have been explored for this purpose. They have been used for many decades in many countries with varying degrees of success at the primary, secondary and tertiary levels of wastewater treatment. Poor optimization of this technology has been due to limited information available about the roles played by the whole system as well as by each component involved in the treatment technology. The current work elucidates the role played by macrophytes and microbial biofilms in the removal of nutrients in the rhizofiltration system. Factors affecting waste removal as well as environmental friendliness of the system were also investigated. The rhizofiltration system was constructed in Durban and was divided into planted (planted with Phragmites australis and Kyllinga nemoralis) and unplanted (reference) section. Dissolved oxygen (DO), pH, water temperature, total dissolved solids (TDS), electrical conductivity (EC) and salinity were monitored. The removal efficiency of nutrients was measured using spectrophotometric methods by measuring the concentration of ammonia, nitrate, nitrite, phosphate and orthophosphate in the wastewater pre- and post-treatment. The total organic carbon, chemical oxygen demand (COD), total Kehldjahl nitrogen, biological oxygen demand (BOD), ammonia, nitrate and the flow rate of wastewater into the system from the settling tank were used for the estimation of carbon dioxide, methane and nitrous oxide emitted from the rhizofilter using the 2009 EPA formulae. Both the planted and reference sections of the system removed nutrients with varying efficiencies. The reduction of nutrients in the rhizofilter was found to be seasonal, with most nutrients removed during the warm seasons. The system also retained more nutrients when wastewater containing low levels of nutrients was used. The unpaired t-test was used to determine the differences between nutrient removals between planted and reference sections. Higher reduction efficiencies of nutrients were obtained in the planted section. Up to 65% nitrite and 99% nitrate were removed while up to 86% total phosphorus was removed in a form of orthophosphate (86%). Removal of total nitrogen was shown to increase under high temperature conditions, while the same conditions decreased the total phosphorus removal. High temperatures also increased the performance of the system. The reduction of nutrients in the system corresponded to reduction of the chemical oxygen demand which also positively correlated to the dissolved oxygen concentration. Considering the discharge limits for all nutrients, the discharges in the effluent of the planted section were within the allowable limits as per South Africa’s Department of Water affairs and Forestry in 2012 but not in 2013. The results obtained in 2013 were due to increased nutrient loading introduced into the system. Diverse microbial communities occurred in the treatment system, with more diversity in the planted section. These organisms were supported by macrophytes in the planted section, and were responsible for nitrogen and phosphorus transformation. This explains why total nitrogen and phosphorus reduction was higher in the planted compared to the reference section. Both the planted and the reference sections of the rhizofiltration system produced the greenhouse gases. When the two sections were compared, the planted section produced more gases. Gases emitted by both sections were lower when compared to emission from sludge treatment reed beds and other conventional systems of wastewater treatments. These findings indicated that constructed rhizofiltration is a cleaner form of waste treatment, producing significantly less greenhouse gases and affecting less of a climate change. Findings of this work have revealed that rhizofiltration technology can be used as a low-cost alternative technology for the treatment of wastewater, using the combination of macrophytes and microbial biofilms. Macrophytes accumulated nitrogen and phosphorus as well as supported diverse microorganisms that metabolized and reduced nutrients in the rhizofiltration unit.


1994 ◽  
Vol 30 (10) ◽  
pp. 179-187 ◽  
Author(s):  
I. T. Miettinen ◽  
P. J. Martikainen ◽  
T. Vartiainen

Transformations in the amount and quality of organic matter (humus) during bank filtration of surface water were studied by analyzing the changes in total organic carbon (TOC), non-purgeable organic carbon (NPOC), chemical oxygen demand (COD), color of water, and UV absorbing humus fractions. The amount of organic matter expressed as TOC, NPOC, and COD depended on temperature and filtration distance from lake water. The color of water and the UV absorbing humus peaks presenting different humus molecule fractions decreased more effectively than other parameters measuring the amount of organic matter in water. The ratio of COD to TOC decreased when the filtration distance of water increased. Our observations indicated that bank filtration of humus-rich lake water changed more the quality of organic matter than its total amount.


2002 ◽  
Vol 45 (1) ◽  
pp. 49-53 ◽  
Author(s):  
C.T. Zanotelli ◽  
W. Medri ◽  
P. Belli Filho ◽  
C.C. Perdomo ◽  
M.R. Mulinari ◽  
...  

This paper shows the performance of a baffled facultative pond for the treatment of piggery wastes. The full-scale system is composed of an equalizer, one decanter (DP), two anaerobic ponds (LA1 and LA2), one facultative pond (LF), with five baffles, and one maturation pond with water hyacinths (LAG). The studies were conducted over a 12 month period in the west region of Santa Catarina, Brazil. The system was supplied daily with a volume of 3 m3/day of farm wastes. A good performance of the treatment system was obtained with average removal efficiencies of 98% for chemical oxygen demand, 93% for total solids, 98% for total phosphorus, 92% for total nitrogen, 7 log units of faecal coliforms and 5 log units of total coliforms. The facultative pond performed well, removing 43% of the chemical oxygen demand, 47% of total nitrogen and 54% of total phosphorus. It was found that the first baffle in the facultative pond was mainly responsible for the efficiency of this pond, and compared with another study the introduction of the baffles improved the removal efficiency by 20% for total phosphorus.


1993 ◽  
Vol 28 (7) ◽  
pp. 125-131 ◽  
Author(s):  
H. H. P. Fang ◽  
C. L. Y. Yeong ◽  
K. M. Book ◽  
C. M. Chiu

An 11-litre sequencing batch reactor (SBR) filled with fibrous packing was found to be very effective for the removal of not only Chemical Oxygen Demand (COD), but also nitrogen from synthetic wastewaters with 250-1034 mg/l of COD and 22-114 mg/l of nitrogen. As compared to the conventional SBR, mis system had a shorter cycle time by skipping the settling step. In addition, denitrification was efficiently conducted in the interior of the ‘bio-pompons', which were formed by the attached growth of biomass on the fibrous packings, even though the bulk of the reactor was under constant aeration. The system was tested at 12 loading conditions, ranging from 0.56 to 4.51 kg-COD/m3-day and from 0.04 to 0.49 kg-NH3−N/m3-day. On average, 95% of COD was removed within 2 h of aeration, while 57% of total nitrogen was removed after a retention time of 4-8 h.


Author(s):  
K. Bernat ◽  
M. Zaborowska ◽  
M. Zielińska ◽  
I. Wojnowska-Baryła ◽  
W. Ignalewski

Abstract The aim of this study was to determine the effectiveness of pollutant removal in sequencing batch biofilm reactors (with floating or submerged carriers) when treating nitrogen- and organic-rich real leachate generated during aerobic stabilization of the biodegradable municipal solid waste. A control reactor contained suspended activated sludge. The share of leachate in synthetic wastewater was 10%, which resulted in ratios of chemical oxygen demand and biochemical oxygen demand to total Kjeldahl nitrogen in the influent of ca. 11 and ca. 8.5, respectively. Regardless of whether the reactors contained carriers or not, the effectiveness of nitrification (84.2–84.3%) and of the removal of chemical oxygen demand (86.5–87.0%), biochemical oxygen demand (95.5–98.0%) and ammonium (88.9–89.3%) did not differ. However, the presence of carriers and their type determined in which phase of the cycle denitrification occurred. In the control reactor, denitrification took place during mixing phase with the effectiveness of ca. 43.2% (57.7% of the total nitrogen removal). During aeration, the oxygen content increased rapidly, thus reduced the possibility of simultaneous denitrification. In reactors with carriers, in the aeration phase, not only nitrification but also denitrification occurred. The increase in oxygen content in wastewater was slower, which could have caused dissolved oxygen gradients and anoxic zones in deeper layers of the biofilm and flocks. In the reactor with floating carriers, the effectiveness of denitrification and total nitrogen removal increased 1.23- and 1.10-times, respectively, as compared to the control reactor. The highest efficiencies (67.7% and 73.0%, respectively) were observed in the reactor with submerged carriers.


Sign in / Sign up

Export Citation Format

Share Document