Pipeline Frequency Test Bed Design

2012 ◽  
Vol 569 ◽  
pp. 477-481
Author(s):  
Jie Wang ◽  
Yu Min He

For the production of high reliability, wide use range, low cost of pipeline frequency test rig, the design scheme is determined, the structural design. Design of experiment platform to meet the requirement of experiment, and has practical application value.

2012 ◽  
Vol 192 ◽  
pp. 83-88
Author(s):  
Jie Wang ◽  
Yu Min He

For the production of high reliability, wide use range, low cost of the bending deflection of pipe test bed, the design of test program was optimized, the structural design. Design of experiment platform to meet the requirement of experiment, and has practical application value.


2014 ◽  
Vol 536-537 ◽  
pp. 786-790
Author(s):  
Bo Yuan ◽  
Wen Bing Lu ◽  
Kai Yue Xu

Taking the power distribution network situation in China into consideration, this paper proposes a communication circuit applied in street lamp control system. It first summarizes the overall design scheme of the control system. And then it demonstrates the high reliability of outbound Two Way Automatic Communication System (TWACS) within one transformer area and the low-cost characteristics of corresponding circuit. Finally, it proposes the design scheme of the communication circuit which can process Power Line Carrier communication (PLC) signals and outbound TWACS signals simultaneously, and it is based on single MCU. This design scheme is conducive to improving the communication efficiency and success rate of the street lamp control system to a great extent.


2021 ◽  
Vol 2095 (1) ◽  
pp. 012064
Author(s):  
Shilong Li ◽  
Yue Wang ◽  
Xing Zhuang

Abstract Standing-up motion assistant machine is a new type of assistant device for the care and motion of the semi-disabled, which can replace the manual motion mode to a great extent and reduce the workload of the care-givers. After a detailed analysis of shortcomings of the structural design of the existing standing-up motion assistant machine in the practical application in elderly institutions, this paper proposes a design scheme and mechanical structure of the hanger. The optimized product is verified based on ergonomics theory. Results show that the design scheme and structure of the hanger of the motion assistant machine proposed in this paper can satisfy the requirements of occupant comfort on the premise of ensuring safety, as well as effectively expand the application of the standing-up motion assistant machine in elderly institutions of varied facility levels.


2003 ◽  
Vol 3 (4) ◽  
pp. 169-175 ◽  
Author(s):  
S. Barbagallo ◽  
F. Brissaud ◽  
G.L. Cirelli ◽  
S. Consoli ◽  
P. Xu

In arid and semiarid regions the reclamation and reuse of municipal wastewater can play a strategic role in alleviating water resources shortages. Public awareness is growing about the need to recycle and reuse water for increasing supply availability. Many wastewater reuse projects have been put in operation in European and Mediterranean countries adopting extensive treatment systems such as aquifer recharge, lagooning, constructed wetlands, and storage reservoirs, mainly for landscape and agricultural irrigation. In agricultural reuse systems, there is an increasing interest in extensive technologies because of their high reliability, and easy and low cost operation and maintenance. Wastewater storage reservoirs have become the option selected in many countries because of the advantages they present in comparison with other treatment alternatives, namely the coupling of two purposes, stabilization and seasonal regulation. This paper describes an example of a wastewater storage system, built in Caltagirone (Sicily, Italy). The storage results in a tertiary treatment of a continuous inlet flow of activated sludge effluents. The prediction of the microbiological water quality has been evaluated by means of a non-steady-state first-order kinetic model. Single and multiple regressions were applied to determine the main variables that most significantly affected die-off coefficients. The proposed model has been calibrated using the results of a field monitoring carried out during a period from March to October 2000.


2021 ◽  
Vol 11 (6) ◽  
pp. 2803
Author(s):  
Jae-Woo Kim ◽  
Dong-Seong Kim ◽  
Seung-Hwan Kim ◽  
Sang-Moon Shin

A quad, small form-factor pluggable 28 Gbps optical transceiver design scheme is proposed. It is capable of transmitting 50 Gbps of data up to a distance of 40 km using modulation signals with a level-four pulse-amplitude. The proposed scheme is designed using a combination of electro-absorption-modulated lasers, transmitter optical sub-assembly, low-cost positive-intrinsic-native photodiodes, and receiver optical sub-assembly to achieve standard performance and low cost. Moreover, the hardware and firmware design schemes to implement the optical transceiver are presented. The results confirm the effectiveness of the proposed scheme and the performance of the manufactured optical transceiver, thereby confirming its applicability to real industrial sites.


2021 ◽  
Author(s):  
Jingjing Yu ◽  
Bihao Hu ◽  
Chuanlan Xu ◽  
Jiazhi Meng ◽  
Shu Yang ◽  
...  

Nickel is widely researched in the electrooxidation of borohydride due to its low cost and abundant reserves, but it’s catalytic activity and stability need to be improved for practical application....


2021 ◽  
Vol 6 (51) ◽  
pp. eaaz5796
Author(s):  
I. D. Sîrbu ◽  
G. Moretti ◽  
G. Bortolotti ◽  
M. Bolignari ◽  
S. Diré ◽  
...  

Future robotic systems will be pervasive technologies operating autonomously in unknown spaces that are shared with humans. Such complex interactions make it compulsory for them to be lightweight, soft, and efficient in a way to guarantee safety, robustness, and long-term operation. Such a set of qualities can be achieved using soft multipurpose systems that combine, integrate, and commute between conventional electromechanical and fluidic drives, as well as harvest energy during inactive actuation phases for increased energy efficiency. Here, we present an electrostatic actuator made of thin films and liquid dielectrics combined with rigid polymeric stiffening elements to form a circular electrostatic bellow muscle (EBM) unit capable of out-of-plane contraction. These units are easy to manufacture and can be arranged in arrays and stacks, which can be used as a contractile artificial muscle, as a pump for fluid-driven soft robots, or as an energy harvester. As an artificial muscle, EBMs of 20 to 40 millimeters in diameter can exert forces of up to 6 newtons, lift loads over a hundred times their own weight, and reach contractions of over 40% with strain rates over 1200% per second, with a bandwidth over 10 hertz. As a pump driver, these EBMs produce flow rates of up to 0.63 liters per minute and maximum pressure head of 6 kilopascals, whereas as generator, they reach a conversion efficiency close to 20%. The compact shape, low cost, simple assembling procedure, high reliability, and large contractions make the EBM a promising technology for high-performance robotic systems.


2017 ◽  
Vol 17 (6) ◽  
pp. 881-885 ◽  
Author(s):  
Luigi Guerriero ◽  
Giovanni Guerriero ◽  
Gerardo Grelle ◽  
Francesco M. Guadagno ◽  
Paola Revellino

Abstract. Continuous monitoring of earth flow displacement is essential for the understanding of the dynamic of the process, its ongoing evolution and designing mitigation measures. Despite its importance, it is not always applied due to its expense and the need for integration with additional sensors to monitor factors controlling movement. To overcome these problems, we developed and tested a low-cost Arduino-based wire-rail extensometer integrating a data logger, a power system and multiple digital and analog inputs. The system is equipped with a high-precision position transducer that in the test configuration offers a measuring range of 1023 mm and an associated accuracy of ±1 mm, and integrates an operating temperature sensor that should allow potential thermal drift that typically affects this kind of systems to be identified and corrected. A field test, conducted at the Pietrafitta earth flow where additional monitoring systems had been installed, indicates a high reliability of the measurement and a high monitoring stability without visible thermal drift.


Sign in / Sign up

Export Citation Format

Share Document