scholarly journals Recycling of Alum from Water Treatment Residue and Reuse It as a Flocculating Agent for Raw Water Treatment

2018 ◽  
Vol 06 (12) ◽  
pp. 216-226
Author(s):  
Pascaline Sanga ◽  
Yves Iradukunda ◽  
Jean Claude Munyemana
2021 ◽  
Author(s):  
Muhammad Amin Rois ◽  
Willy Dharmawan

Abstract Banyu Urip reservoir management heavily rely on river-sourced water as water injection to meet Voidage Replacement Ratio target of 1. The treatment facility which consist of Raw Water Basin, Clarifiers, Multi Media Fine (MMF) Filters and Cartridge Filters, is sensitive to seasonal transition and river condition. This paper shares lesson learnt in operating such facility and troubleshooting guidance to overcome challenges of high turbidity during rainy season and lack of river water volume during drought season. To maintain the design intent of Banyu Urip (BU) water treatment facility in achieving water injection quality and quantity at reasonable cost, following activities were undertaken: [1] Critical water parameters data gathering & analysis across each unit; [2] Clarifier Chemical injection dosage verification based on laboratory test; [3] MMF Media coring inspection to assess the filtering media condition; [4] MMF Filters backwash parameters optimization; [5] MMF Filter on-off valve sequencing optimization to address water hammering issue; [6] Water injection rate management to deal with river water source availability along the year. Critical water parameters analysis revealed that chemical dosages were in-adequate to treat the five times higher turbidity coming into Clarifiers during early rain 2019. On top of this, low Raw Water Basin level at the end of long drought further contributed to jeopardize Clarifier's operation. Although in-adequate chemicals injection was resolved at early 2020, the treatment cost remained high, especially on filtration section. Media coring result on MMF Filters confirmed that the filtering media have been poisoned by carried-over mud from Clarifiers during upset. The operation of MMF Filters required extensive optimization on backwash parameters to successfully recover the MMF Filters performance without media replacement. Latest media coring on the worst MMF Filter showed that there was no more top mud layer and the amount of trapped mud had been decreased significantly. Cartridge Filter replacement interval was improved from 38 hours to 186 hours, therefore water treatment cost dropped with quite significant margin. Additionally, the availability of each MMF Filters was also improved. At the same time, the high water injection rate during 2020 rainy season, had successfully increased reservoir pressure buffer up to its maximum point as the anticipation of prolonged drought season. This paper provides the troubleshooting guidance for MMF Filter application in season-prone water treatment facility including insights on interpretation of media coring result and linking it back to optimization strategy on the MMF Filters drain down time for effective backwash process without having excessive media loss.


Author(s):  
Gloria Naa Dzama Addico ◽  
Jörg D. Hardege ◽  
Jiri Kohoutek ◽  
Kweku Amoaku Atta DeGraft-Johnson ◽  
Pavel Babica

<p>Although cyanobacterial blooms and cyanotoxins represent a worldwide-occurring phenomenon, there are large differences among different countries in cyanotoxin-related human health risk assessment, management practices and policies. While national standards, guideline values and detailed regulatory frameworks for effective management of cyanotoxin risks have been implemented in many industrialized countries, the extent of cyanobacteria occurrence and cyanotoxin contamination in certain geographical regions is under-reported and not very well understood. Such regions include major parts of tropical West and Central Africa, a region constisting of more than 25 countries occupying an area of 12 million km<sup>2</sup>, with a total population of 500 milion people. Only few studies focusing on cyanotoxin occurrence in this region have been published so far, and reports dealing specifically with cyanotoxin contamination in drinking water are extremely scarce. In this study, we report seasonal data on cyanobacteria and microcystin (MC) contamination in drinking water reservoirs and adjacent treatment plants located in Ghana, West Africa. During January-June 2005, concentrations of MCs were monitored in four treatment plants supplying drinking water to major metropolitan areas in Ghana: the treatment plants Barekese and Owabi, which serve Kumasi Metropolitan Area, and the plants Kpong and Weija, providing water for Accra-Tema Metropolitan Area. HPLC analyses showed that 65% samples of raw water at the intake of the treatment plants contained intracellular MCs (maximal detected concentration was 8.73 µg L<sup>-1</sup>), whereas dissolved toxins were detected in 33% of the samples. Significant reduction of cyanobacterial cell counts and MC concentrations was achieved during the entire monitoring period by the applied conventional water treatment methods (alum flocculation, sedimentation, rapid sand filtration and chlorination), and MC concentration in the final treated water never exceeded 1 µg L<sup>-1</sup> (WHO guideline limit for MCs in drinking water). However, cyanobacterial cells (93-3,055 cell mL<sup>-1</sup>) were frequently found in the final treated water and intracellular MCs were detected in 17% of the samples (maximal concentration 0.61 µg L<sup>-1</sup>), while dissolved MCs were present in 14% of the final treated water samples (maximal concentration 0.81 µg L<sup>-1</sup>). It indicates a borderline efficiency of the water treatment, thus MC concentrations in drinking water might exceed the WHO guideline limit if the treatment efficiency gets compromised. In addition, MC concentrations found in the raw water intake might represent significant human health risks for people living in areas with only a limited access to the treated or underground drinking water.</p>


2020 ◽  
Vol 22 (2) ◽  
pp. 139-148
Author(s):  
Ilham Tri Purnomo ◽  
M. Zaky Alfarisi ◽  
Mutioro Sukmono

Curah hujan yang tinggi di Jakarta merupakan potensi yang luar biasa dan perlu dimanfaatkan. Pemanfaatan air hujan menjadi air siap minum di Gedung Dinas Pendidikan Provinsi DKI Jakarta merupakan sebuah terobosan penerapan konsep bangunan green building di daerah Ibukota DKI Jakarta. Perencanaan diawali dengan menghitung kebutuhan air minum untuk karyawan di kantor dengan kebutuhan air minum sebanyak 480 liter/hari atau 132.480 liter/tahun. Air hujan difilter dua kali untuk memenuhi standar air minum, sehingga air dapat dikonsumsi. Eksisting raw water tank digunakan untuk menampung air baku hasil filter awal (pretreatment). Sistem pengaliran airnya menggunakan sistem gabungan, air dipompakan dari bak penampung menuju rooftank atau reservoir dengan kapasitas volume sebesar 2550 m3, kemudian air didistribusikan ke lokasi tempat air minum. Pemilihan filter akhir (treatment) dipilih dari perbandingan antara sistem reverses osmosis, sistem depot air minum, dengan sistem dispenser (galon) dan dihasilkan metode reverse osmosis lebih baik dari segi kualitas air serta menguntungkan dari segi ekonomis. Pada tahun ke-2 modal awal yang telah dikeluarkan pada tahun pertama telah kembali. Kemudian pada tahun berikutnya penghematan biaya meningkat. Dibutuhkan biaya keseluruhan pelaksanaan sebesar Rp. 496.636.000,00. Kata Kunci: air hujan, air siap minum, reverse osmosis, water treatment


2021 ◽  
Vol 9 (01) ◽  
pp. 512-524
Author(s):  
Konan Lopez Kouame ◽  
◽  
Nogbou Emmanuel Assidjo ◽  
Andre Kone Ariban ◽  
◽  
...  

This article presents an optimization of the drinking water treatment process at the SUCRIVOIRE treatment station. The objective is to optimize the coagulation and flocculation process (fundamental process of the treatment of said plant)by determining the optimal dosages of the products injected and then proposes a program for calculating the optimal dose of coagulant in order to automatically determine the optimal dose of the latter according to the raw water quality. This contribution has the advantage of saving the user from any calculations the latter simply enters the characteristics of the raw effluent using the physical interface of the program in order to obtain the optimum corresponding coagulant concentration. For the determination of the optimal coagulant doses, we performed Jar-Test flocculation tests in the laboratory over a period of three months. The results made it possible to set up a polynomial regression model of the optimal dose of alumina sulfate as a function of the raw water parameters. A program for calculating the optimal dose of coagulant was carried out on Visual Basic. The optimal doses of coagulant obtained vary from 25, 35, 40 and 45 mg/l depending on the characteristics of the raw effluent. The model obtained is: . Finally, verification tests were carried out using this model on the process. The results obtained meet the WHO drinkability standards for all parameters for a settling time of two hours.


2012 ◽  
Vol 610-613 ◽  
pp. 2483-2487
Author(s):  
Xiao Dan Zhao ◽  
Chun Hua Wu ◽  
Zhen Zhou

Distribution and transformation of molecular weight of organic matters in canal raw water, primary coagulated water, secondary coagulated water, enhanced coagulated water and water filtered by activated carbon were monitored by ultrafiltration membrane method. The results show that organics on the fraction of molecular weight less than 2kDa has the largest ratio in total organics of outlets of coagulation and activated carbon tank. Removal rate of total organics is about 73% by secondary coagulation, but which of micromolecule organics of molecular weight less than 2kDa is only 10%, which can be removed by activated carbon more than 80%.


2018 ◽  
Vol 13 (3) ◽  
pp. 461-468
Author(s):  
Tomáš Kučera ◽  
Veronika Hanušová

Abstract This paper presents the results of the first phase of research that evaluates options for the optimization of waste-water management during water treatment. The research was conducted in a specific treatment plant, with surface-water sources, to verify the option of recirculating part of the sludge-water back to the beginning of the technological line and mixing this with a portion of raw water. An evaluation of risk factors is necessary for such treatment, as they could render the recirculation of the backwashing water impossible. The motivation behind this research lies in the potential savings of operating costs, particularly the costs of pumping raw water from a watercourse. This research evaluated data regarding the quality of both raw and processed water, focusing on six indicators – turbidity, color, chemical oxygen demand, and concentrations of aluminum, iron and manganese. The evaluation established through these factors indicates that the plan for returning a certain volume of sludge-water back into the process is possible and should cause no problems regarding the quality of drinking water produced. Based on the results of the first phase of this research, it is possible to recirculate up to 6% of overall raw-water volume back into the process.


2007 ◽  
Vol 7 (18) ◽  
pp. 2651-2655 ◽  
Author(s):  
M.A. Zazouli ◽  
S. Nasseri . ◽  
A.H. Mahvi . ◽  
A.R. Mesdaghinia . ◽  
M. Younecian . ◽  
...  