scholarly journals Malaria PCR Detection in Cambodian Low-Transmission Settings: Dried Blood Spots Versus Venous Blood Samples

2015 ◽  
Vol 92 (3) ◽  
pp. 573-577 ◽  
Author(s):  
Lydie Canier ◽  
Nguon Chea ◽  
Malen Ken ◽  
Philippe Bosman ◽  
Nimol Khim ◽  
...  
2015 ◽  
Vol 8 (1) ◽  
Author(s):  
Jansen Fernandes Medeiros ◽  
Tatiana Amaral Pires Almeida ◽  
Lucyane Bastos Tavares Silva ◽  
Jose Miguel Rubio ◽  
James Lee Crainey ◽  
...  

Blood ◽  
1998 ◽  
Vol 92 (5) ◽  
pp. 1807-1813 ◽  
Author(s):  
James D. Cook ◽  
Carol H. Flowers ◽  
Barry S. Skikne

Abstract The present study was undertaken to assess the feasibility of using ferritin and transferrin receptor measurements on dried capillary blood spots to identify iron deficiency (ID) in public health surveys. Measurements on serum and blood spots prepared from venous blood were performed in 71 healthy subjects, 41 of whom were iron-replete and 30 who had ID, either without (n = 20) or with (n = 10) anemia. Parallel measurements were performed on hemolyzed whole blood and washed hemolyzed red blood cells to assess the erythrocyte contribution of ferritin and transferrin receptor to dried blood samples. The concentration of ferritin in dried blood samples was threefold higher than serum assays due to the release of ferritin from hemolyzed erythrocytes, which diminished the usefulness of ferritin measurements for detecting ID. On the other hand, there was negligible erythrocyte contribution to the measurement of transferrin receptor in dried blood spots. The most sensitive parameter in dried blood spots was the ratio of receptor/ferritin, which was suitable for identifying iron-deficiency anemia (IDA), but less reliable than serum assays for detecting milder ID without anemia. We conclude that tandem measurements of serum ferritin and transferrin receptor in dried blood spots can be used to facilitate the identification of IDA in epidemiologic studies. © 1998 by The American Society of Hematology.


Metabolites ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 680
Author(s):  
Dorothea Haas ◽  
Jana Hauke ◽  
Kathrin V. Schwarz ◽  
Lucia Consalvi ◽  
Friedrich K. Trefz ◽  
...  

Monitoring phenylalanine (Phe) concentrations is critical for the management of phenylketonuria (PKU). This can be done in dried blood spots (DBS) or in EDTA plasma derived from capillary or venous blood. Different techniques are used to measure Phe, the most common being flow-injection analysis tandem mass spectrometry (FIA-MS-MS) and ion exchange chromatography (IEC). Significant differences have been reported between Phe concentrations in various sample types measured by different techniques, the cause of which is not yet understood. We measured Phe concentrations in 240 venous blood samples from 199 patients with hyperphenylalaninemia in dried blood spots, EDTA plasma and erythrocytes by FIA-MS-MS and IEC. Phe concentrations were significantly lower in erythrocytes than in plasma leading to about 19% lower Phe DBS concentrations compared with plasma independent from the method used for quantification. As most therapy recommendations for PKU patients are based on plasma concentrations reliable conversion of DBS into plasma concentrations is necessary. Variances of Phe concentrations in plasma and DBS are not linear but increases with higher concentrations indicating heteroscedasticity. We therefore suggest the slope of the 75th percentile from quantile regression as a correction factor.


Blood ◽  
1998 ◽  
Vol 92 (5) ◽  
pp. 1807-1813
Author(s):  
James D. Cook ◽  
Carol H. Flowers ◽  
Barry S. Skikne

The present study was undertaken to assess the feasibility of using ferritin and transferrin receptor measurements on dried capillary blood spots to identify iron deficiency (ID) in public health surveys. Measurements on serum and blood spots prepared from venous blood were performed in 71 healthy subjects, 41 of whom were iron-replete and 30 who had ID, either without (n = 20) or with (n = 10) anemia. Parallel measurements were performed on hemolyzed whole blood and washed hemolyzed red blood cells to assess the erythrocyte contribution of ferritin and transferrin receptor to dried blood samples. The concentration of ferritin in dried blood samples was threefold higher than serum assays due to the release of ferritin from hemolyzed erythrocytes, which diminished the usefulness of ferritin measurements for detecting ID. On the other hand, there was negligible erythrocyte contribution to the measurement of transferrin receptor in dried blood spots. The most sensitive parameter in dried blood spots was the ratio of receptor/ferritin, which was suitable for identifying iron-deficiency anemia (IDA), but less reliable than serum assays for detecting milder ID without anemia. We conclude that tandem measurements of serum ferritin and transferrin receptor in dried blood spots can be used to facilitate the identification of IDA in epidemiologic studies. © 1998 by The American Society of Hematology.


Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 4566-4566
Author(s):  
Olga Sala Torra ◽  
Lan Beppu ◽  
Susan Branford ◽  
Linda Fletcher ◽  
Gooley Ted ◽  
...  

Abstract In many parts of the world, diagnosis and monitoring of CML patients is limited by the availability and cost of molecular testing. In countries without molecular diagnostic capabilities, blood samples can be shipped to central labs, but this is both hampered by sample degradation, and the high costs of shipping. This study explores the method of directly spotting peripheral blood onto a paper template (dried blood spots), with subsequent shipping, RNA extraction, and BCR-ABL testing. Methods: Blood Spots and Shipment. We received dried blood spots from Australia and African countries by mail or courier, and blood from CML patients from our institution were also used for these experiments. 200μL of blood (PB) was pipetted onto Whatman 503 Protein Saver Cards (PSC; Sigma-Aldrich), where each card contains four 50μL spots. Cards were allowed to dry for at least 24 hours at room temperature. For mailing, PSCs were sealed into glassine envelopes with a packet of desiccant, and then placed inside a mailing envelope following DOT and IATA regulation for shipping non-regulated, exempt human specimens. RNA Extraction from Cards and %BCR-ABL determination. Blood spots were incubated with proteinase K followed by RNA isolation using RNeasy Mini Kits (Qiagen). Extracted RNA was quantified using a NanoDrop spectrometer (Thermo Scientific). %BCR-ABL was determined using the automated Cepheid GeneXpert platform or manual two-step quantitative RT-PCR on the 7900HT Fast Real-Time PCR System (Applied Biosystems). Results: Bench top time course: To test for effects of long transit times on RNA quality, we performed a time course study of cards at room temperature (RT) with 5 samples. For each sample, multiple cards were spotted with PB. The cards were then allowed to sit at RT for predetermined amounts of time, up to 42 days, before extracting RNA. We measured RNA integrity for one of the specimens (CML # 5) and found rapid degradation with the RIN number going from 8.7 for the fresh blood to 2.8 after 28 days on the card. However the amplification for both BCR-ABL and ABL differed less than one cycle between the fresh blood and the last time point by manual qRT-PCR (BCR-ABL Ct = 23.63 for fresh blood and 24.06 for day 28 PSC; ABL Ct = 26.69 for fresh blood and 27.64 for day 28 PSC). Figure 1 shows the results of the time course experiment for the 5 samples as a plot of ΔCt versus time in days. BCR-ABL qRT-PCR concordance studies: We compared the %BCR-ABL results obtained in fresh specimen at the institution sending the sample with the %BCR-ABL results we obtained from RNA extracted from PSC using the Cepheid GeneXpert. Paired evaluable results were available for 9 samples with a median WBC = 9.8 x 109/L (range: 3.37x109/L – 85.5x109/L). Samples were 8 to 49 days old at the time of extraction. The amount of RNA input into the GeneXpert reaction ranged from 38.75ng to 1μg. The %BCR-ABL detected ranged from 0.37% to 27% (see Table). The mean absolute difference between fresh blood and PSC BCR-ABL% is 2%; the relative mean percent change for BCR-ABL, using fresh blood as the reference is 13.1% (S.D., 31.2), P = 0.24. Conclusions and future directions: Dried blood spots are relatively inexpensive method to transport blood that preserves enough RNA stability to allow highly accurate BCR-ABL detection, when compared to results performed on an identical platform using fresh peripheral blood samples. Further studies are undergoing to accurately determine the sensitivity of this method and the feasibility of using regular mail for inexpensive transport of specimens. Table 1IDWBC (1000/μL)Sample Age at Spotting (Days)Sample Age at RNA extraction (Days)RNA ng/μlVolume GeneXPert (μL)Paper %BCR-ABL (IS)GeneXpertFresh Blood % BCR-ABL (IS) GeneXpertI1na010426349naI224.101311092745I38009181544naI47.4285102.4*3.1I55.50495241.92I63.61307.4225912I785.5130102102439I812.212912.415128.8I9na1281.5250.37*0.71I103.370273257.85.7I1115.912731102325I126.612714.415na2.3 *%BCR-ABL was manually calculated due to late ABL Cts because of low starting material. Figure 1 Figure 1. Disclosures No relevant conflicts of interest to declare.


2020 ◽  
Author(s):  
yanyun wang ◽  
yun Sun ◽  
yu-guo Wang ◽  
tao Jiang

Abstract Background: Phenylketonuria is the most common inherited metabolism disease in China. This study aimed to identify a new, sensitive, simple, and easy method of screening maternal Phenylketonuria in the fetal stage.Methods: Samples of amniotic fluid, dried blood spots, and blood collected on the same day were obtained from women in the second-trimester (16–28 weeks). Women had to meet the following criteria: (i) isolated high risk of quadruple marker screening or cell-free DNA screening, (ii) women who gave birth to at least one child with intellectual disability of unknown etiology, and (iii) women who gave birth to a child who died young from unknown etiology. The exclusion criteria were as follows: clinically evident chorioamnionitis, multiple gestation, and laboratory signs of infection in the amniotic fluid sample. Phenylalanine levels were measured using tandem mass spectrometry. Women who met criterion (i) served as controls whose results were used to set reference values of Phenylalanine in amniotic fluid. Women who met criteria (ii) and (iii) served as the case group whose results were used to check for maternal Phenylketonuria. The Spearman rank correlation test was used to analyze the correlation of Phenylalanine in amniotic fluid and in venous blood. Results: We analyzed 365 samples of amniotic fluid. Among them, 345 were included in the control group, with reference values of Phenylalanine in amniotic fluid of 10.79–48.47 µmol/L. Twenty cases were included in the case group. One woman in the case group was diagnosed with hyperphenylalaninemia whose fetus was diagnosed with maternal Phenylketonuria by comprehensive analysis of Phenylalanine in dried blood spots and in amniotic fluid, head circumference in fetal ultrasound, and a previous history of adverse pregnancy. The correlation between Phenylalanine concentrations in venous blood and in amniotic fluid was weak.Conclusions: Phenylalanine can be readily measured in amniotic fluid. Relative to controls, amniotic fluid levels of Phenylalanine was increased in maternal Phenylketonuria. These results can support the use of Phenylalanine as a screening tool for maternal Phenylketonuria. The significance of these change requires further study.


Life ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1125
Author(s):  
Alexandre Marchand ◽  
Ingrid Roulland ◽  
Florian Semence ◽  
Olof Beck ◽  
Magnus Ericsson

To combat the COVID-19 pandemic, vaccines against SARS-CoV-2 are now given to protect populations worldwide. The level of neutralizing antibodies following the vaccination will evolve with time and vary between individuals. Immunoassays quantifying immunoglobulins against the viral spike (S) protein in serum/plasma have been developed, but the need for venous blood samples could limit the frequency and scale of control in populations. The use of a quantitative dried blood spot (DBS) that can be self-collected would simplify this monitoring. The objective of this study was to determine whether a quantitative DBS device (Capitainer qDBS 10 µL) could be used in combination with an Elecsys anti-SARS-CoV-2 S immunoassay from Roche to follow the development and persistence of anti-S antibodies. This objective was carried out through two clinical studies. The first study investigated 14 volunteers who received two doses of the Comirnaty (Pfizer) vaccine. The levels of anti-S antibodies and the progression over time post-vaccination were studied for three months. The level of produced antibodies varied between subjects, but a similar trend was observed. The anti-S antibodies were highly stimulated by the second dose (×100) and peaked two weeks later. The antibody levels subsequently decreased and three months later were down to 65%. DBS proved to be sufficiently sensitive for use in evaluating the immune status against SARS-CoV-2 over a prolonged time. The second cohort was composed of 200 random patients from a clinical chemistry department in Stockholm. In this cohort, we had no information on previous COVID-19 infections or vaccination. Nevertheless, 87% of the subjects had anti-S immunoglobulins over 0.8 U/mL, and the bias between plasma and DBS proved to be variable, as was also seen in the first vaccination study.


Sign in / Sign up

Export Citation Format

Share Document