Effect of Humidity on Condensation in Vapour Compression Refrigeration System for Fresh Foods Transport Vehicles

Author(s):  
Nagarajan Sendrayaperumal ◽  
Ganesh Rathinavel ◽  
Arunagirinathan Vijayarangan ◽  
Kannan Natarajan

In today’s world the developed countries rely on the refrigerated container (reefer) vehicles for the transportation of cold chain products such as fresh foods. In India this technology was introduced in late 1980s but the growth was very slow compared to other countries and failed to match the international trends. However recently, with fast development of roadways, urbanisation and connectivity the reefers get a massive response. The reefers have several advantages but they consume considerable amount of electrical energy to operate. Reefer works based on vapour compression refrigeration cycle in which condenser is an important device. This condenser uses fan-blown atmospheric air over it to remove vaporization heat from refrigerant. The temperature of refrigerant after condensation has effects on Coefficient of performance (COP) of the refrigeration system. This temperature can be altered by the relative humidity of air. The result of our project shows that the increase in air humidity by 18.60% increases the COP by 11.37% and also it reduces the power consumption.

Author(s):  
B Sairamakrishna ◽  
◽  
T Gopala Rao ◽  
N Rama Krishna ◽  
◽  
...  

This experimental investigation exemplifies the design and testing of diffuser at compressor inlet and nozzle at condenser outlet in vapour compression refrigeration system with the help of R134a refrigerant. The diffuser with divergence angle of 12°,14° and the nozzle with convergent angle 12°,14° are designed for same inlet and outlet diameters. Initially diffusers are tested at compressor inlet diffuser is used with inlet diameter equal to exit tube diameter of evaporator and outlet tube diameter is equal to suction tube diameter of the compressor. Diffuser helps to increases the pressure of the refrigerant before entering the compressor it will be helps to reduces the compression work and achieve higher performance of the vapour compression refrigeration system. Then nozzles are testing at condenser outlet, whereas nozzle inlet diameter equal to discharging tube diameter of condenser and outlet diameter equal to inlet diameter of expansion valve. Additional pressure drop in the nozzle helped to achieve higher performance of the vapour compression refrigeration system. The system is analyzes using the first and second laws of thermodynamics, to determine the refrigerating effect, the compressor work input, coefficient of performance (COP).


Nano Hybrids ◽  
2015 ◽  
Vol 9 ◽  
pp. 33-43 ◽  
Author(s):  
A. Manoj Babu ◽  
S. Nallusamy ◽  
K. Rajan

This paper investigates the reliability and performance of a refrigeration system using nanolubricant with 1, 1, 1, 2-Tetrafluoroethane (HFC-134a) refrigerant. Mineral Oil (MO) is mixed with nanoparticles such as Titanium Dioxide (TiO2) and Aluminium Oxide (Al2O3). These mixtures were used as the lubricant instead of Polyolester (POE) oil in the HFC-134a refrigeration system as HFC-134a does not compatible with raw mineral oil. An investigation was done on compatibility of mineral oil and nanoparticles mixture at 0.1 and 0.2 grams / litre with HFC-134a refrigerant. To carry out this investigation, an experimental setup was designed and fabricated in the lab. The refrigeration system performance with the nanolubricant was investigated by using energy consumption test. The results indicate that HFC-134a and mineral oil with above mentioned nanoparticles works normally and safely in the refrigeration system. The refrigeration system performance was better than the HFC-134a and POE oil system. Thus nanolubricant (Mixture of Mineral Oil (MO) and nanoParticles) can be used in refrigeration system to considerably reduce energy consumption and better Coefficient of Performance (COP).


2014 ◽  
Vol 984-985 ◽  
pp. 1174-1179
Author(s):  
N. Austin ◽  
P.M. Diaz ◽  
D.S. Manoj Abraham ◽  
N. Kanthavelkumaran

Study on environment friendly mixed refrigerant to replace R134a in vapour compression refrigeration (VCR) System. The mixed refrigerants investigated are propane (R290), butane (R600), isobutene (R600a) and R134a. Even though the ozone depletion potentials of R134a relative to CFC-11 are very low; the global warming potentials are extremely high and also expensive. For this reason, the production and use of R134a will be terminated in the near future. Hydrocarbons are free from ozone depletion potential and have negligible global warming potential. The results showed that, mixed refrigerant with charge of 80 g satisfy the required freezer air temperature when R134a with a charge of 110 g is used as refrigerant. The actual COP of refrigerator using mixed refrigerant was almost nearer that of the system using R134a as refrigerant. The coefficient of performance of the vapour compression refrigeration system using mixed refrigerant MR-3 [R134a/R290/ R600a/ R600 (20/35/40/5)] is having very close value with R134a and the Global warming potential of MR-3 is negligible when compared with R134a. Hence the mixed refrigerant MR-3 is chosen as an environmental friendly alternate refrigerant to R134a. The exergy analysis of the vapour compression refrigeration system using R134a and all the above mixtures are investigated. The effect of evaporator temperature on exergy efficiency and exergy destruction ratio of the system are experimentally studied. The exergy defect in the compressor, condenser, expansion device and evaporator are also obtained. Key words: R134a, Mixed refrigerant, Chlorofluorocarbons, Propane, Butane, Isobutene, REFPROP, COP, ODP, GWP, Exergy, VCR System.


2014 ◽  
Vol 25 (4) ◽  
pp. 23-36 ◽  
Author(s):  
Vaibhav Jain ◽  
Gulshan Sachdeva Sachdeva ◽  
Surendra S Kachhwaha

In a present study, the performance of a vapour compression–absorption cascaded refrigeration system (CRS) under fouled conditions was analysed. The main effect of fouling is to decrease the effectiveness of the heat exchanger. Thus, the overall conductance (UA) of the heat exchanger is decreased. Hence, another interpretation of fouling is to reduce the effective size of the heat exchanger. In the present work, the percentage decrease in the overall conductance value (UA) of evaporator and condenser due to their fouling is varied from 0 to 50% and its consequences on various aspects of CRS are generated to ascertain any possible patterns. The detailed first law analysis reveals that for a clean evaporator and condenser, the electricity consumption is 67.5% less than vapour compression system (VCS) for the same cooling capacity. CRS is able to save only 61.3% of electrical energy when evaporator and condenser conductance is reduced by 50% due to fouling. Evaporator and condenser fouling decreased the COP and rational efficiency of the system by 4.7% and 10.5% respectively. It is also important to note that irreversibility in the evaporator and condenser is increased by 42.4% and 62.1% respectively, when their individual performance is degraded by 50% due to fouling.


2020 ◽  
Vol 39 (3) ◽  
pp. 776-784
Author(s):  
T.S. Mogaji ◽  
A. Awolala ◽  
O.Z. Ayodeji ◽  
P.B. Mogaji ◽  
D.E. Philip

This study focused on development of an improved vapour compression refrigeration system (IVCR system). Dedicated mechanical subcooling cycle is employed in attaining the developed IVCR system. The system is composed of two cycles cascade refrigeration system working with R134a. It consists of a rectangular shape with total storage space of 0.582 m3, made of galvanized mild steel and internally insulated with 0.05 m polystyrene foam. Tests under a wide range operating temperature conditions were carried out on the developed IVCR system. Performance evaluation of the system was characterized in terms of cooling capacity and coefficient of performance (COP). Experimental results showed that the COP of the subcooled system improved better than that of the main system from 18.0% to about 33.5% over an evaporating temperature range of -10 to 30oC. It can be concluded that the use of dedicated sub cooling cycle in VCR system is more efficient and suitable for the betterment of thermal system performance. Keywords: Vapour compression Refrigeration system, Coefficient of performance, dedicated subcooled system, Condensation temperature, Evaporation temperature.


Author(s):  
P. Kesavulu ◽  
K. Prahlada Rao

The present work is to analyse the performance of VCRS system with two condensers i.e., Serpentine and Spiral tube using Isobutane (R600a) refrigerant. These two condensers are kept in parallel with other components of refrigerating unit while construction. The performance of refrigeration system is checked for each condenser at various cooling loads. The performance of the condenser is measured for whole refrigeration unit in terms of C.O.P, compressor work, Efficiency of the system, Heat Rejection Ratio, and Heat Rejected from Condenser. The result will show that for both condensers for refrigerant R600a, coefficient of performance increases with increase in heating load, increase in refrigerating effect and decrease in compressor work. From the analysis of two condensers, coefficient of performance of refrigeration system using serpentine and spiral condenser VCRS is more compared to conventional VCRS. Also, R600a gives better cooling effect than tetrafluroethane (R134a). The substitution of R134a by R600a is useful in order to generate a good thermo-economic output, zero ODP (Ozone Depletion Potential) and very low GWP (Global Warming Potential).


2014 ◽  
Vol 18 (suppl.2) ◽  
pp. 363-374 ◽  
Author(s):  
Kolandavel Mani ◽  
Vellappan Selladurai ◽  
Natarajan Murugan

In this paper mathematical models were developed using design of experiments technique for the performance prediction of refrigeration system parameters such as refrigerating capacity, power consumption and coefficient of performance. The models developed were checked for their adequacy using F-test. The performances of vapour compression refrigeration system with different refrigerants R12, R134a and R290/R600a were compared. The R290/R600a mixture showed 10.7-23.6% higher coefficient of performance than that with R12 and R134a and it was found that the hydrocarbon mixture with 68% propane and 32% iso-butane could be used as a substitute for R12 and R134a.


2016 ◽  
Vol 78 (9-2) ◽  
Author(s):  
Mohd Yusoff Senawi ◽  
Farah Wahidah Mahmod

A computerized simulation of a simple single-stage vapour-compression refrigeration system has been made. The steady-state simulation uses the accurate property correlations developed by Cleland for refrigerant R134a. The inputs to the program are: evaporator pressure, condenser pressure, superheating at evaporator outlet, subcooling at condenser outlet and compressor isentropic efficiency. The program outputs are: refrigerating effect, compressor work input, coefficient of performance (COP) and suction vapour flow rate per kW of refrigeration. An increase in the evaporator pressure from 150 to 250 kPa improves the COP by 40%. The COP is decreased by 35% when the condenser pressure is increased from 1000 to 1500 kPa. Increasing the superheat at the evaporator outlet from 0 to 160C improves the COP by 2.6%. An increase in subcooling at the condenser outlet from 0 to 160C increases the COP by 20%. The COP is improved by 150% when the compressor isentropic efficiency is increased from 0.4 to 1.


Author(s):  
J S Tiedeman ◽  
S A Sherif

This paper presents the results of an optimization study for a two-stage vapour compression refrigeration system based on the coefficient of performance (COP) and exergetic efficiency. Traditional studies have focused on the first-law performance, while those studies dealing with the second law have primarily been limited to performance analysis as opposed to performance optimization. The results of this study indicate that the use of the common approximation of the geometric mean to find the optimum interstage pressure can lead to significant errors in interstage pressure. However, an optimum COP or exergetic efficiency based on the same interstage pressure has relatively little error. This trend is valid as long as the isentropic compressor efficiencies are ‘reasonable’. Second-law optimization revealed that the optimum data curves themselves have a maxima for each set of conditions tested. This leads to the conclusion that for a given system there is an optimum set of conditions that lead to the lowest amount of exergy destruction for that system. This is shown to occur consistently for reasons that are, as yet, undetermined. Finally, polynomial equations have been fitted to the resultant optimum data for the interstage pressure, COP and exergetic efficiency. These equations allow for the reproduction of optimum points based on high-and low-pressure compressor efficiencies and condenser and evaporator pressures.


2013 ◽  
Vol 388 ◽  
pp. 91-95 ◽  
Author(s):  
Henry Nasution ◽  
Abdul Latiff Zulkarnain ◽  
Azhar Abdul Aziz ◽  
Mohd Rozi Mohd Perang

An experimental study to evaluate the energy consumption of a split type air conditioning is presented. The compressor works with the fluids R-22 and HCR-22 and has been tested varying the internal heat load 0, 500, 700 and 1000 W. The measurements taken during the one hour experimental periods at 10-minutes interval times for temperature setpoint of 20oC. The performance data considered where the evaporator cooling load, the condenser heat rejection, the electrical energy consumption, the refrigeration system temperatures, and the room temperature. And hence the Coefficient of Performance (COP) could be determined. The final results of this study show an overall better energy consumption of the HFC-22 compared with the R-22.