scholarly journals Optimal Planning of On-Grid Hybrid Microgrid for Remote Island Using HOMER Software, Kish in Iran

2019 ◽  
Vol 3 (2) ◽  
pp. 13 ◽  
Author(s):  
Mehdi Jahangiri

HOMER software functions as a tool for modeling and optimization of an energy generation micropower system based on renewable technologies. In this paper for the first time the monthly real load data have been used in HOMER to design a renewable-based microgrid in grid-connected mode for Kish Island, Iran. The calculations were performed in a way that the designed system could supply the load demand of the studied area with the lowest cost, least pollution, and highest reliability. To overcome the intermittency of renewable energy sources such as wind and solar, a combination of these sources in a hybrid system and installation of battery storage systems were considered. The solar radiation and wind speed data required by the software were obtained from the country’s meteorology and NASA website and used in the software. The analysis results of four scenarios, including national grid/diesel generator, national grid/diesel generator/solar cell, national grid/diesel generator/wind turbine, and national grid/diesel generator/solar cell/wind turbine, showed the prices per kWh of $0.483, $0.505, $0.472, $0.537, respectively. In these scenarios, the share of renewable energies was 0%, 8%, 11%, and 26%, respectively. The highest amount of electricity sold to the national grid was 1597095 kWh/y for the fourth scenario which had also the lowest rate of CO2 emissions by 4128650 kg/y.

2020 ◽  
Vol 184 ◽  
pp. 01070
Author(s):  
Ayani Nandi ◽  
Vikram Kumar Kamboj

Daily load demand for industrial, residential and commercial sectors are changing day by day. Also, inclusion of e-mobility has totally effected the operations of realistic power sector. Hence, to meet this time varying load demand with minimum production cost is very challenging. The proposed research work focuses on the mathematical formulation of profit based unit commitment problem of realistic power system considering the impact of battery electric vehicles, hybrid electric vehicles and plug in electric vehicles and its solution using Intensify Harris Hawks Optimizer (IHHO). The coordination of plants with each other is named as Unit commitment of plants in which the most economical patterns of the generating station is taken so as to gain low production cost with higher reliability. But with the increase in industrialization has affected the environment badly so to maintain the balance between the generation and environment a new thinking of generating low cost power with high reliability by causing less harm to environment i.e. less emission of flue gases is adopted by considering renewable energy sources.


2020 ◽  
Vol 12 (7) ◽  
pp. 2880 ◽  
Author(s):  
Hasan Masrur ◽  
Harun Or Rashid Howlader ◽  
Mohammed Elsayed Lotfy ◽  
Kaisar R. Khan ◽  
Josep M. Guerrero ◽  
...  

Following a rise in population, load demand is increasing even in the remote areas and islands of Bangladesh. Being an island that is also far from the mainland of Bangladesh, St. Martin’s is in need of electricity. As it has ample renewable energy resources, a renewable energy-based microgrid system seems to be the ultimate solution, considering the ever-increasing price of diesel fuel. This study proposes a microgrid system and tests its technical and economic feasibility in that area. All possible configurations have been simulated to try and find the optimal system for the island, which would be eco-friendly and economical with and without considering renewable energy options. The existing power supply configuration has also been compared to the best system after analyzing and investigating all technical and economic feasibility. Sensitivity and risk analysis between different cases provide added value to this study. The results show that the current diesel-based system is not viable for the island’s people, but rather a heavy burden to them due to the high cost of per unit electricity and the net present cost. In contrast, a PV /Wind/Diesel/Battery hybrid microgrid appeared to be the most feasible system. The proposed system is found to be around 1.5 times and 28% inexpensive considering the net present cost and cost of energy, respectively, with a high (56%) share of renewable energy which reduces 23% carbon dioxide.


Author(s):  
P. Venkaiah ◽  
B. K. Sarkar

Abstract The advantages of renewable energy sources are available freely in nature, inexhaustible, produce either no or little pollution and low gestation period. Among all renewable energy sources, wind energy has become one of the leading resources for power production in the world as well as in the India. According to WWEA, the wind turbine installation capacity in the world has been reached over 539.291GW by the end of 2017. The entire wind power installed capacity by the end of 2017 covers more than 5% of global demand of electricity. In India, the present wind power installation capacity on October, 2017 was over 32.7GW and wind energy contribution is 55% of the total renewable energy capacity in the country. Inspite of having sharp growth rate in wind in India, only a fraction of wind energy has been tapped until now out of 302 GW wind potential which is available above 100 m height on shore. Practical horizontal axis wind turbine converts kinetic energy in the wind into useful energy by using airfoil blades. Blade element momentum (BEM) theory becomes very popular due to its simplicity in mathematical calculation as well as accuracy. Hydraulic pitch actuation system has certain advantages due to its versatility, ability to produce constant force and torque irrespective of the disturbances outside of the system, ease and accuracy of control, simplicity, safety and economy. In the present study a semi rotary actuator has been utilized for turbine pitch actuation. In order to extract maximum power from available wind, fractional order PID controller (FOPID) has been developed for pitch control of wind turbine rotor blade. The performances of PID as well as FOPID controller have been compared with available wind data. The performance of FOPID controller was satisfactory compare to PID controller.


2014 ◽  
Vol 1008-1009 ◽  
pp. 179-182
Author(s):  
Iveta Gressová

Our planet gives us many mineral sources, but they have a big disadvantage. They are finite. Non-renewable energy sources are enough only for decades, exceptionally for centuries. Current generation is aware of the importance of using other energy sources, such as sunlight, wind, rain, tides, waves and geothermal heat. These energy sources are renewable. It means that they come from sources, which are naturally replenished on a human timescale. One of these sources is wind energy. Use of this kind of energy source needs an initial investment, but it can reduce cost of running a household and other sectors. This article is about Savonius wind turbine and its use for the needs of public lighting.


2015 ◽  
Author(s):  
Sayem Zafar ◽  
Mohamed Gadalla

A renewable energy harvesting system is designed and tested for micro power generation. Such systems have applications ranging from mobile use to off-grid remote applications. This study analyzed the use of micro power generation for small unmanned aerial vehicle (UAV) flight operations. The renewable energy harvesting system consisted of a small wind turbine, flexible type PV panels and a small fuel cell. Fuel cell is considered the stable source while PV and wind turbine produced varying power output. The load of around 250 W is simulated by a small motor. The micro wind turbine with the total length of 4.5 m and the disk diameter of 1.8 m is tested. The micro wind turbine dimensions make it big enough to be used to charge batteries yet small enough to be installed on rooftops or easily transportable. The wind turbine blades are installed at an angle of 22°, with respect to the disk plane, as it gives the highest rotation. The voltage and current output for the corresponding RPM and wind speeds are recorded for the wind turbine. Two 2 m and a single 1 m long WaveSol Light PV panels are tested. The PV tests are conducted to get the current and voltage output with respect to the solar flux. The variation in solar flux represented the time of day and seasons. A 250 W PEM fuel cell is tested to run the desired load. Fuel cell’s hydrogen pressure drop is recorded against the output electrical power and the run time is recorded. System performance is evaluated under different operating and environmental conditions. Data is collected for a wide range of conditions to analyze the usability of renewable energy harvesting system. This energy harvesting method significantly improves the usability and output of the renewable energy sources. It also shows that small renewable energy systems have existing applications.


2021 ◽  
Vol 18 (1) ◽  
pp. 39-46
Author(s):  
M. Shuaibu ◽  
A.S. Abubakar ◽  
A.F. Shehu

Renewable energy sources (RES) are being integrated to electrical grid to complement the conventional sources to meet up with global electrical energy demand. Among other RES, Wind Energy Conversion Systems (WECS) with Doubly Fed Induction Generator (DFIG) have gained global electricity market competitiveness because of the flexible regulation of active and reactive power, higher power quality, variable speed operation, four quadrant converter operation and better dynamic performance. Grid connected DFIG-based WECS are prone to disturbances in the network because of direct connection of stator windings to grid. The ability of the Wind Turbine (WT) to remain connected during grid faults is termed the Fault Ride-Through (FRT) capability. The grid code requirement for integrating the DFIG-based WTs to power networks specified that they must remain connected and support the grid stability during grid disturbances of up to 1500 ms. The use of compensation devices offers the best FRT compliance thereby protecting the DFIG and the converters from voltage fluctuations and over currents during the grid fault. The paper presents a review of techniques employed in ensuring FRT compliance. The article also proposes the state-of-the-art techniques for compensating voltage sag/swell and limiting the fault short-circuit current. Keywords: Renewable energy sources, DFIG, wind turbine system, fault ride-through, grid codes, dual-functional DVR


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6655
Author(s):  
Ning Zhang ◽  
Nien-Che Yang ◽  
Jian-Hong Liu

Power system scheduling of renewable energy sources has been studied extensively due to the severe increase in pollution caused by conventional energy sources. In this study, a multi-objective scheduling model of a hybrid microgrid is proposed to minimize the cost of hybrid microgrids and maximize the power supply reliability. The main power generation units such as the wind turbines, photovoltaic (PV) cells, and battery banks are used in this hybrid microgrid. In this study, the optimal sizing of PV panels and battery banks are obtained using multi-objective particle swarm optimization (MOPSO) for the proposed multi-objective scheduling model. The lifetime of battery banks is considered in the energy storage system (ESS) model. Finally, the practicality of the scheduling model proposed in this study is verified by four examples.