scholarly journals EXPERIMENTAL INVESTIGATION OF CYLINDRICAL FOOD PRODUCT DURING FORCED CONVECTION COOLING

2021 ◽  
Vol 23 (04) ◽  
pp. 102-116
Author(s):  
Taliv Hussain ◽  
◽  
Zafar Alam ◽  
Adnan Hafiz ◽  
◽  
...  

The objective of this work is to study the transient heat transfer behavior during precooling of cylindrical food product at different air flow rates. Temperature measurement is carried out at the center of the specimen at different air flow rates (3.8, 4.0, 4.2 & 4.5 m/s). These temperature distributions are plotted with time. The terms of Fourier equation were evaluated and thermal diffusivity was plotted against the temperature variation during cooling of the cylindrical food product.Surface film conductance values is also calculated in present work, at different air flow rates. These values are effective values, which included the additional cooling effect due to moisture evaporation from the exposed product surface. Variation of Reynolds number and Nusselt number is also plotted with different air velocities and it is found that more favorable results of thermal conductivity and thermal diffusivity is obtain at 3.8 m/s. Which ultimately saves energy and provide optimum cooling for the specimen at the given air velocity.

2021 ◽  
Vol 23 (11) ◽  
pp. 574-582
Author(s):  
Taliv Hussain ◽  
◽  
Ashish Kumar ◽  
Ashad Ahmad ◽  
◽  
...  

Using pre-cooling technique, food products of perishable nature are desired to be conserved from spoiling. Fruits and vegetables and are suggested to be precooled just after harvesting to avoid any food decay. The precooling enhance their storage life and keeps up quality of vegetables and fruits. Thus, an experimental analysis has been carried out to study temperature variation of spherical food product, i.e. mosambi, during the precooling process. In the current study, the effect of three different air velocities, i.e. 4.3, 4.8 and 5.0 m/s, during precooling of spherical food product has been observed in a forced convection environment. Also, determination of the thermophysical properties of the spherical food product for three different radial positions, i.e. XC= 0.042 m (centre), XM= 0.028 mm (middle) and XS= 0.014 m (surface), has been carried out. The effect of different air velocities and different radial positions on temperature profile of food product was detected. It has been noticed that proper choice of cold air velocity can decrease cooling time of spherical food product, hence resulting in energy saving.


1984 ◽  
Vol 19 (1) ◽  
pp. 87-100
Author(s):  
D. Prasad ◽  
J.G. Henry ◽  
P. Elefsiniotis

Abstract Laboratory studies were conducted to demonstrate the effectiveness of diffused aeration for the removal of ammonia from the effluent of an anaerobic filter treating leachate. The effects of pH, temperature and air flow on the process were studied. The coefficient of desorption of ammonia, KD for the anaerobic filter effluent (TKN 75 mg/L with NH3-N 88%) was determined at pH values of 9, 10 and 11, temperatures of 10, 15, 20, 30 and 35°C, and air flow rates of 50, 120, and 190 cm3/sec/L. Results indicated that nitrogen removal from the effluent of anaerobic filters by ammonia desorption was feasible. Removals exceeding 90% were obtained with 8 hours aeration at pH of 10, a temperature of 20°C, and an air flow rate of 190 cm3/sec/L. Ammonia desorption coefficients, KD, determined at other temperatures and air flow rates can be used to predict ammonia removals under a wide range of operating conditions.


Designs ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 4
Author(s):  
Dillon Alexander Wilson ◽  
Kul Pun ◽  
Poo Balan Ganesan ◽  
Faik Hamad

Microbubble generators are of considerable importance to a range of scientific fields from use in aquaculture and engineering to medical applications. This is due to the fact the amount of sea life in the water is proportional to the amount of oxygen in it. In this paper, experimental measurements and computational Fluid Dynamics (CFD) simulation are performed for three water flow rates and three with three different air flow rates. The experimental data presented in the paper are used to validate the CFD model. Then, the CFD model is used to study the effect of diverging angle and throat length/throat diameter ratio on the size of the microbubble produced by the Venturi-type microbubble generator. The experimental results showed that increasing water flow rate and reducing the air flow rate produces smaller microbubbles. The prediction from the CFD results indicated that throat length/throat diameter ratio and diffuser divergent angle have a small effect on bubble diameter distribution and average bubble diameter for the range of the throat water velocities used in this study.


2021 ◽  
Vol 99 (Supplement_1) ◽  
pp. 134-135
Author(s):  
Michaela B Braun ◽  
Kara M Dunmire ◽  
Michael Sodak ◽  
Jerry Shepherd ◽  
Randy Fisher ◽  
...  

Abstract This study was performed to evaluate hammermill tip speed, assistive airflow and screen hole diameter on hammermill throughput and characteristics of ground corn. Corn was ground using two Andritz hammermills (Model: 4330–6, Andritz Feed & Biofuel, Muncy,PA) measuring 1-m in diameter each equipped with 72 hammers and 300 HP motors. Treatments were arranged in a 3 × 3 × 3 factorial design with 3 tip speeds (3,774, 4,975, and 6,176 m/min), 3 screen hole diameters (2.3, 3.9 and 6.3 mm), and 3 air flow rates (1,062, 1,416, and 1,770 fan RPM). Corn was ground on 3 separate days to create 3 replications and treatments were randomized within day. Samples were collected and analyzed for moisture, particle size, and flowability characteristics. Data were analyzed using the GLIMMIX procedure of SAS 9.4 with grinding run serving as the experimental unit and day serving as the block. There was a 3-way interaction for standard deviation (Sgw), (linear screen hole diameter × linear hammer tip speed × linear air flow, P = 0.029). There was a screen hole diameter × hammer tip speed interaction (P < 0.001) for geometric mean particle size dgw (P < 0.001) and composite flow index (CFI) (P < 0.001). When tip speed increased from 3,774 to 6,176 m/min the rate of decrease in dgw was greater as screen hole diameter increased from 2.3 to 6.3 mm resulting in a 67, 111, and 254 µm decrease in dgw for corn ground using the 2.3, 3.9, and 6.3 mm screen hole diameter, respectively. For CFI, increasing tip speed decreased the CFI of ground corn when ground using the 3.9 and 6.3 mm screen. However, when grinding corn using the 2.3 mm screen, there was no evidence of difference in CFI when increasing tip speed. In conclusion, the air flow rate did not influence dgw of corn but hammer tip speed and screen size were altered and achieved a range of dgw from 304 to 617 µm.


Solar Energy ◽  
1986 ◽  
Vol 37 (5) ◽  
pp. 363-374 ◽  
Author(s):  
C. Karakatsanis ◽  
M.N. Bahadori ◽  
B.J. Vickery

Desalination ◽  
2009 ◽  
Vol 236 (1-3) ◽  
pp. 135-142 ◽  
Author(s):  
Julie Lebegue ◽  
M. Heran ◽  
A. Grasmick
Keyword(s):  
Air Flow ◽  

Author(s):  
Ari Kettunen ◽  
Timo Hyppa¨nen ◽  
Ari-Pekka Kirkinen ◽  
Esa Maikkola

The main objective of this study was to investigate the load change capability and effect of the individual control variables, such as fuel, primary air and secondary air flow rates, on the dynamics of large-scale CFB boilers. The dynamics of the CFB process were examined by dynamic process tests and by simulation studies. A multi-faceted set of transient process tests were performed at a commercial 235 MWe CFB unit. Fuel reactivity and interaction between gas flow rates, solid concentration profiles and heat transfer were studied by step changes of the following controllable variables: fuel feed rate, primary air flow rate, secondary air flow rate and primary to secondary air flow ratio. Load change performance was tested using two different types of tests: open and closed loop load changes. A tailored dynamic simulator for the CFB boiler was built and fine-tuned by determining the model parameters and by validating the models of each process component against measured process data of the transient test program. The know-how about the boiler dynamics obtained from the model analysis and the developed CFB simulator were utilized in designing the control systems of three new 262 MWe CFB units, which are now under construction. Further, the simulator was applied for the control system development and transient analysis of the supercritical OTU CFB boiler.


2021 ◽  
Vol 13 (9) ◽  
pp. 4748
Author(s):  
Edwin Villagran ◽  
Carlos Bojacá ◽  
Mohammad Akrami

The use of covered structures is an alternative increasingly used by farmers to increase crop yields per unit area compared to open field production. In Latin American countries such as Colombia, productive areas are located in with predominantly hillside soil conditions. In the last two decades, farmers have introduced cover structures adapted to these soil conditions, structures for which the behavior of factors that directly affect plant growth and development, such as microclimate, are still unknown. Therefore, in this research work, a CFD-3D model successfully validated with experimental data of temperature and air velocity was implemented. The numerical model was used to determine the behavior of air flow patterns and temperature distribution inside a Colombian passive greenhouse during daytime hours. The results showed that the slope of the terrain affects the behavior of the air flow patterns, generating thermal gradients inside the greenhouse with values between 1.26 and 16.93 °C for the hours evaluated. It was also found that the highest indoor temperature values at the same time were located in the highest region of the terrain. Based on the results of this study, future researches on how to optimize the microclimatic conditions of this type of sustainable productive system can be carried out.


2014 ◽  
Vol 627 ◽  
pp. 153-157
Author(s):  
Nawadee Srisiriwat ◽  
Chananchai Wutthithanyawat

The temperature distribution of hot air flow in heating zone of a rectangular duct has been investigated for drying application. The experimental set-up consists of a heater and a fan to generate the hot air flow in the range of temperature from 40 to 100°C and the range of air velocity between 1.20 and 1.57 m/s. An increase of the heater power supply increases the hot air temperature in the heating zone while an increase of air velocity forced by fan decreases the initial temperature at the same power supply provided to generate the hot air flow. The temperature distribution shows that the hot air temperature after transferring through air duct decreases with an increase of the length of the rectangular duct. These results are very important for the air flow temperature and velocity control strategy to apply for heating zone design in the drying process.


2004 ◽  
Vol 67 (3) ◽  
pp. 493-498 ◽  
Author(s):  
R. Y. MURPHY ◽  
K. H. DRISCOLL ◽  
L. K. DUNCAN ◽  
T. OSAILI ◽  
J. A. MARCY

Chicken leg quarters were injected with 0.1 ml of the cocktail culture per cm2 of the product surface area to contain about 7 log(CFU/g) of Salmonella. The inoculated leg quarters were processed in an air/steam impingement oven at an air temperature of 232°C, an air velocity of 1.4 m/s, and a relative humidity of 43%. The endpoint product temperatures were correlated with the cooking times. A model was developed for pathogen thermal lethality up to 7 log(CFU/g) reductions of Salmonella in correlation to the product mass (140 to 540 g) and cooking time (5 to 35 min). The results from this study are useful for validating thermal lethality of pathogens in poultry products that are cooked via impingement ovens.


Sign in / Sign up