scholarly journals Hydraulic performance Analysis of water supply distribution network using water GEM v8i

2021 ◽  
Author(s):  
Dessalegn Geleta Ebsa ◽  
Fekadu Fufa

Abstract. The study evaluates the hydraulic analysis of water supply distribution network using water GEMS v8i. which used for modeling and Simulation of hydraulic parameters in the distribution networks. The hydraulic parameters which analyzed by using this software were junction pressure, velocity of water in networking system, and nodal demands and the overall result of water supply did not satisfied demand. The water distribution system has been analyzed for steady state and extended period simulation for the present population scenario for intermittent water supply using water Gems v8i. About 14 percent of the total number of nodes analyzed had negative pressures while 68 percent of the nodes had pressures less than the adopted pressure for the analysis. These negative pressures indicate that there is inadequate head within the distribution network for water conveyance to all the sections. In the same manner 85.6 percent of flow velocities in the pipes were within the adopted velocity while around 14.4 percent of the velocities exceeded the adopted velocity. The results in this study revealed that the performance of the water distribution system of under current demand is inefficient.

The study presents the hydraulic design and analysis of Rural Water Distribution System (WDS) for Nava shihora region of zone 1 of the state of Gujarat, India. Water supply distribution system is designed for this study for population estimated for future 30 years. LOOP 4.0 and Water Gems v8i software have been used and the results are compared to determine the economical size of pipes for water distribution system. The economical size of pipes of water supply distribution system is designed by considering the constraints; residual pressure at each node, velocity of flow in pipe, head loos in pipes, material of pipes, elevated service reservoir level, peak factor and available commercial pipe diameters. Further water distribution system has been analyzed for extended period simulation (EPS) for the present population scenario for intermittent water supply using Water Gems v8i. Further water supply system is analyzed the residual chlorine concentration at nodes and in the pipe links and also the total cost of water supply system of rural region is estimated.


2014 ◽  
Vol 909 ◽  
pp. 428-432 ◽  
Author(s):  
Ioan Sarbu ◽  
Gabriel Ostafe

Distribution networks are an essential part of all water supply systems. Distribution system costs within any water supply scheme may be equal to or greater than 60% of the entire cost of the project. The reliability of supply is much greater in the case of looped networks. The pipe networks have concentrated outflows or uniform outflow along the length of each pipe. In some pipes with variable discharge of a looped distribution network, water velocity could be reversed between its extremities. Thus, it is a water stall point denominated neutral point in which the discharge is null. In this paper a mathematical model for the determination of water stall point location in the pipes with distributed consumption is developed. This model has been implemented in a computer program for PC microsystems. Numerical example will be presented to demonstrate the accuracy and efficiency of the proposed model.


2018 ◽  
Vol 8 (3) ◽  
pp. 459-467 ◽  
Author(s):  
J. C. Agunwamba ◽  
O. R. Ekwule ◽  
C. C. Nnaji

Abstract Population explosion in urban settings usually exerts enormous pressure on existing water supply systems. The result is that overall water demand is usually not satisfied. This study evaluated the performance of Wadata sub-zone water distribution system with respect to pressure, velocity, hydraulic head loss and nodal demands using WaterCAD and Epanet. There was no statistical difference between the results of Epanet and WaterCAD, however, Epanet produced slightly higher results of pressure and velocity in about 60% of all cases examined. About 19 percent (18.52%) of the total number of nodes analyzed had negative pressures while 69 percent (69%) of the nodes had pressures less than the adopted pressure for the analysis. These negative pressures indicate that there is inadequate head within the distribution network for water conveyance to all the sections. About 88 percent (87.7%) of flow velocities in the pipes were within the adopted velocity while around 12 percent (12.3%) of the velocities exceeded the adopted velocity. These excess velocities are partly responsible for the leakages and pipe bursts observed at some points within the system. The results in this study revealed that the performance of the water distribution system of Wadata sub-zone under current demand is inefficient.


2020 ◽  
Vol 21 (2) ◽  
pp. 227-235
Author(s):  
Muhammad Rizki Apritama ◽  
I Wayan Koko Suryawan ◽  
Yosef Adicita

ABSTRACTThe clean water supply system network on Lengkang Kecil Island was developed in 2019. A small portion of the community's freshwater comes from harvesting rainwater and dug wells, which are only obtained during the rainy season. The primary source of clean water used by the community comes from underwater pipelines with a daily discharge of 0.86 l/sec. The water supply of the Lengkang Kecil Island community is 74.3 m3/day, with 146 House Connections (HCs) and to serve public facilities such as elementary schools, primary health centers, and mosques. Hydraulic evaluation of clean water distribution using EPANET 2.0 software on flow velocity shows the lowest rate of 0.29 m/s and the highest of 1.21 m/s. The lowest pressure value in the distribution system is 6.94-6.96 m and headloss units in the range 0.08-0.25 m/km. These three criteria are still within the distribution network design criteria (feasible). A carbon footprint can be calculated from each activity from the analysis of the evaluation of clean water distribution networks. The most massive emissions came from pumping activities with 131 kg CO2-eq, followed by emissions from wastewater 62.5 kgCO2-eq. Further research is needed to determine the quality of wastewater and the design for a centralized wastewater treatment plant (IPALT) to improve Lengkang Kecil Island residents' living standards.Keywords: Lengkang Kecil Island, water, EPANET, carbon footprintABSTRAKJaringan sistem penyediaan air bersih pada Pulau Lengkang Kecil dimulai pada tahun 2019. Sebagian kecil air bersih yang digunakan masyarakat berasal dari pemanenan air hujan dan sumur gali yang hanya didapat pada musim hujan. Sumber air bersih utama yang digunakan masyarakat berasal dari pengaliran perpipaan bawah laut dengan debit harian 0,86 l/detik. Kebutuhan air masyarakat Pulau Lengkang Kecil adalah 74,3 m3/hari dengan 146 Sambungan Rumah (SR) serta untuk melayani fasilitas umum seperti sekolah dasar (SD), puskesmas, dan masjid. Evaluasi hidrolis distribusi air bersih dengan menggunakan software EPANET 2.0 terhadap kriteria kecepatan aliran menunjukkan nilai terendah 0,29 m/s dan tertinggi 1,21 m/s. Nilai sisa tekan dalam sistem distribusi adalah 6,94–6,96 m dan unit headloss pada kisaran 0,08–0,25 m/km. Ketiga kriteria ini masih berada dalam kriteria desain jaringan distribusi (layak). Dari analisis evaluasi jaringan distribusi air bersih, dapat dihitung jejak karbon yang dihasilkan dari setiap kegiatannya. Emisi terbesar berasal dari kegiatan pemompaan dengan nilai 131 kgCO2-eq, diikuti dengan emisi yang berasal dari air limbah dengan nilai 62,5 kgCO2-eq. Penelitian lanjutan diperlukan untuk mengetahui kualitas dari air limbah dan desain untuk instalasi pengolahan air limbah terpusat (IPALT) untuk meningkatkan taraf hidup penduduk Pulau Lengkang Kecil.Kata kunci: Pulau Lengkang Kecil, air, EPANET, jejak karbon


2005 ◽  
Vol 5 (2) ◽  
pp. 31-38
Author(s):  
A. Asakura ◽  
A. Koizumi ◽  
O. Odanagi ◽  
H. Watanabe ◽  
T. Inakazu

In Japan most of the water distribution networks were constructed during the 1960s to 1970s. Since these pipelines were used for a long period, pipeline rehabilitation is necessary to maintain water supply. Although investment for pipeline rehabilitation has to be planned in terms of cost-effectiveness, no standard method has been established because pipelines were replaced on emergency and ad hoc basis in the past. In this paper, a method to determine the maintenance of the water supply on an optimal basis with a fixed budget for a water distribution network is proposed. Firstly, a method to quantify the benefits of pipeline rehabilitation is examined. Secondly, two models using Integer Programming and Monte Carlo simulation to maximize the benefits of pipeline rehabilitation with limited budget were considered, and they are applied to a model case and a case study. Based on these studies, it is concluded that the Monte Carlo simulation model to calculate the appropriate investment for the pipeline rehabilitation planning is both convenient and practical.


2009 ◽  
Vol 9 (1) ◽  
pp. 67-74 ◽  
Author(s):  
Elise Corbi ◽  
Valérie Jacquemet ◽  
Alain Quendo ◽  
Francine Manciot ◽  
Adeline Lamy ◽  
...  

Lyon, France has the opportunity to distribute in abundance a groundwater resource with a good quality for drinking water. However, the length and the complexity of the distribution network can lead to consumer complaints in some areas of the water distribution system. In order to improve the organoleptic quality of distributed water, the water supplier wants to get a better understanding of potential taste and odour formation and to succeed in controlling it. Since 2006, activities have been taken with targeted analyses and sensory evaluation of water, taking into account both the consumers' private networks and the citywide distribution network. The first results were focused on the occurrence of bromophenols along the water distribution system, the understanding of the mechanisms of formation of such compounds, as well as their incidence on taste-and-odour events at the consumer's home.


Symmetry ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 2096
Author(s):  
Samayan Narayanamoorthy ◽  
Veerappan Annapoorani ◽  
Samayan Kalaiselvan ◽  
Daekook Kang

Every country’s influence and livelihood is centered on that country’s water source. Therefore, many studies are being conducted worldwide to improve and sustain water resources. In this research paper, we have selected and researched the water scheme for groundwater recharge and drinking water supply of drought prone areas. The water project is aimed at connecting the drought prone areas of the three districts of Tamil Nadu to filling up the ponds in their respective villages and raising the ground water level and meeting the drinking water requirement. We have chosen a multi-criteria decision method to select the best alternative in a complex situation. When reviewing the implementation of this water project, many experts and people who will benefit from this project may have some hesitation and ambiguity in their suggestion on choosing the best water distribution system.We believe that the benefits of this project can be fully availed of if we choose a water distribution system. Our contribution in this article is to choose the best water distribution system for this project by use of our proposed multi-criteria decision making (MCDM) methods, hesitant fuzzy standard deviation with multi-objective optimization method by ratio analysis (HFSDV-MOORA), hesitant fuzzy standard deviation with technique, for order preference by similarity to an ideal solution (HFSDV-TOPSIS) and hesitant fuzzy standard deviation with VIsekriterijumsko Kompromisno Rangiranje (HFSDV-VIKOR), which will provide the best solution for improving the water resource for the drought-prone areas of three districts. Finally, we have identified and compared the correlation coefficient between proposed methods. As a result of the study, it has been found that the best water supply system is closed concrete pipes laid along agricultural land through the rural areas.


2004 ◽  
Vol 2 (3) ◽  
pp. 137-156 ◽  
Author(s):  
M. M. Aral ◽  
J. Guan ◽  
M. L. Maslia ◽  
J. B. Sautner ◽  
R. E. Gillig ◽  
...  

In a recently completed case-control epidemiological study, the New Jersey Department of Health and Senior Services (NJDHSS) with support from the Agency for Toxic Substances and Disease Registry (ATSDR) documented an association between prenatal exposure to a specific contaminated community water source and leukaemia in female children. An important and necessary step in the epidemiological study was the reconstruction of the historical water supply strategy of the water distribution system serving the Dover Township area, New Jersey. The sensitivity of solutions to: (1) pressure and pattern factor constraints, (2) allowable operational extremes of water levels in the storage tanks, and (3) the non-uniqueness of the water supply solution are analysed in detail. The computational results show that the proposed approach yields satisfactory results for the complete set of monthly simulations and sensitivity analyses, providing a consistent approach for identifying the historical water supply strategy of the water distribution system. Sensitivity analyses indicated that the alternative strategy obtained from the revised objective function and the variation of constraints did not yield significantly different water supply characteristics. The overall analysis demonstrates that the progressive optimality genetic algorithm (POGA) developed to solve the optimization problem is an effective and efficient algorithm for the reconstruction of water supply strategies in water distribution systems.


2012 ◽  
Vol 17 (4) ◽  
pp. 688-699
Author(s):  
Marina Valentukevičienė ◽  
Gytautas Ignatavičius ◽  
Auksė Amosenkienė

Drinking water distribution system takes a significant place in sustainable urban development. In order to solve some environmental issues it is necessary to improve the maintenance of the environmental impact of chemical compounds which can come in contact with water. The aim of the research is to complete the analysis of the sustainable development of drinking water pipelines in Lithuania as well as to structure the chemical content of pipelines for further increase of supplied water quality and simplification of maintenance. Analytical and descriptive methods were used in the research process. The investigation included 150 samples that were obtained in different water stagnation times in lab-scaled pipelines. During the research the following indicators were set: total iron, manganese, ammonium ions, nitrate and nitrite concentrations, turbidity and chemical oxygen demand (CODCr). To ensure sustainability of drinking water distribution system in the end of this research the appliance of a certain model of actions was considered. This model says that material of potable water network must be chosen depending on water chemical indicators, water reaction with pipeline material and scale formation causes. Consequently, to reduce a negative effect of chemical processes on the drinking water supply measures of sustainable ecological development have to be taken. Santrauka Geriamojo vandens tiekimo sistema yra labai svarbus darnios miesto plėtros objektas. Siekiant išspręsti tam tikras aplinkosaugos problemas, būtina padidinti cheminių junginių, kurie gali kontaktuoti su vandeniu, kontrolę, taip užtikrinant tinkamą poveikio aplinkai priežiūrą. Šio mokslinio tyrimo tikslas – atlikti geriamojo vandens vamzdyno Lietuvoje analizę darnaus vystymosi aspektu, struktūrizuoti cheminę vamzdynų sudėtį, siekiant pagerinti tiekiamo vandens kokybę ir supaprastinti tolesnę vandentiekio vamzdynų priežiūrą. Mokslinio darbo metu buvo taikomi analitiniai ir eksperimentiniai tyrimo metodai. Buvo ištirta 150 mėginių, paimtų iš laboratorijoje sukonstruoto vamzdyno. Mėginiai tirti atsižvelgiant į vandens išbuvimo vamzdyne trukmę. Tyrimo metu buvo nustatomi šie cheminiai indikatoriai: bendroji geležis, mangano koncentracija, amonio jonų kiekis, nitritų ir nitratų koncentracijos, drumstumas ir cheminis deguonies suvartojimas (ChDSCr). Siekiant užtikrinti geriamojo vandens tiekimo sistemos tvarumą, tyrimo pabaigoje buvo pasiūlytas tam tikras veiksmų modelis. Jis rodo, kad vandentiekio vamzdynų medžiaga turi būti parinkta pagal tiekiamo vandens cheminius indikatorius, vandens sąveikos su vamzdyno medžiaga ir nuosėdų formavimosi priežastis. Todėl būtina imtis darnaus vystymo priemonių, mažinant neigiamą cheminių procesų įtaką tiekiamo vandens kokybei.


Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6221
Author(s):  
Jedrzej Bylka ◽  
Tomasz Mróz

The water supply system is one of the most important elements in a city. Currently, many cities struggle with a water deficit problem. Water is a commonly available resource and constitutes the majority of land cover; however, its quality, in many cases, makes it impossible to use as drinking water. To treat and distribute water, it is necessary to supply a certain amount of energy to the system. An important goal of water utility operators is to assess the energy efficiency of the processes and components. Energy assessments are usually limited to the calculation of energy dissipation (sometimes called “energy loss”). From a physical point of view, the formulation of “energy loss” is incorrect; energy in water transport systems is not consumed but only transformed (dissipated) into other, less usable forms. In the water supply process, the quality of energy—exergy (ability to convert into another form)—is consumed; hence, a new evaluation approach is needed. The motivation for this study was the fact that there are no tools for exergy evaluation of water distribution systems. A model of the exergy balances for a water distribution system was proposed, which was tested for the selected case studies of a water supply system and a water treatment station. The tool developed allows us to identify the places with the highest exergy destructions. In the analysed case studies, the highest exergy destruction results from excess pressure (3939 kWh in a water supply system and 1082 kWh in a water treatment plant). The exergy analysis is more accurate for assessing the system compared to the commonly used energy-based methods. The result can be used for assessing and planning water supply system modernisation.


Sign in / Sign up

Export Citation Format

Share Document