scholarly journals OVERALL QUALITY CONTROL OF 1:10000 ORTHOPHOTO PRODUCTS IN THE THIRD NATIONAL LAND SURVEY

Author(s):  
Q. Q. Yan ◽  
Y. S. Zhao ◽  
C. Liu ◽  
X. Ma ◽  
X. Wu

Abstract. Orthographic image is an important reference data source for the third national land survey, as well as the positioning benchmark and statistical basis of the national land survey, which determines the accuracy of the third national land survey results and the progress of follow-up work, and is also an important component of the third national land survey results. In order to ensure that the production of 1:10000 high-resolution orthophoto images meets the needs of the third national land survey work, and meets the relative requirements to the production of orthophoto products, it is really necessary to carry out quality control of orthophoto products.Based on the checking and accepting of 1:10000 orthophoto images at the national level, this paper discusses the quality control method of 1:10000 orthophoto products from the overall inspection. First of all, this paper studies and analyzes the key nodes of quality control in the overall inspection and clarifies the quality control requirements of each quality control key node;On the basis of carefully sorting out the typical problems found in the overall inspection of orthophoto products, carry out in-depth analysis of the causes and give corresponding solutions.This paper provides a technical reference for the quality inspection of other scale orthophoto products, and also provides a solution to the quality improvement of 1:10000 orthophoto products.

Sensors ◽  
2019 ◽  
Vol 19 (20) ◽  
pp. 4524 ◽  
Author(s):  
Minfeng Song ◽  
Xiufeng He ◽  
Xiaolei Wang ◽  
Ye Zhou ◽  
Xueyong Xu

A GNSS station, located on the shore of sea and inland waters, and equipped with standard geodetic receivers and antennas, can be used to measure water levels using a technique called GNSS Interferometric Reflectometry (GNSS-IR). The classical GNSS-IR method is based on SNR data and LSP spectrum analysis method. In order to promote the application of GNSS-IR, the accuracy of the results needs to be further improved, and quality control needs to be achieved better. Classical quality control methods include denoising filtering based on data source SNR; post-processing filtering based on results; morphological analysis based on parameters, such as the ratio of the maximum peak value to the background noise mean, the ratio of the maximum peak to the sub-peak, and the amplitude of the maximum peak. All three methods have the problem of correct frequency extraction under multiple approximate peak conditions. This paper focuses on the performance analysis of three methods of quality control for two situations with real examples, summarizes the advantages and disadvantages of each method, and discusses the measures in applications. Considering the limitations in the threshold setting for the third method, a new quality control method combining multiple parameters and external constraints is proposed. This method is more flexible, especially in dealing with a periodogram with multiple similar peaks, breaking through the premise that the frequency corresponding to the maximum peak is the correct frequency, and validated in two different environments. The experimental results show that the proposed method can improve the accuracy of the measured water level while ensuring the amount of the results. It eliminates the gross errors effectively and uses the data efficiently.


Author(s):  
X. Ma ◽  
Q. Q. Yan ◽  
X. Wu

Abstract. The third national land survey is based on the orthophotos products. Only by providing 1:10000 orthophoto products that meet the quality requirements can the third national land survey be carried out smoothly, and the third national land survey products can be guaranteed to be accurate and reliable. Positional accuracy as an important quality element of 1:10000 orthophoto products is a key factor affecting the quality of 1:10000 orthophoto products, and directly affects the quality of the third national land survey products.This paper introduces the content of the positional accuracy quality inspection in the 1:10000 orthophoto products of the third national land survey.The mean square error in plane position and the image edge match are two important test entries in the quality control of positional accuracy . The paper specifically elaborates on the quality control of the above two important test entries. The quality control indexes of mean square error in plane position and the image edge match are introduced in detail, and the quality inspection method and quality evaluation method of position accuracy are proposed. And, the main quality problems found in the positional accuracy checking are illustrated by way of case analysis. At the same time, the cause analysis was carried out for these specific quality problems, and corresponding improvement suggestions were also proposed.This paper provides technical support and reference for the quality inspection of 1:10000 orthophoto products, and also has some positive effects on quality improvement.


JEMAP ◽  
2020 ◽  
Vol 3 (1) ◽  
Author(s):  
Albertus Reynaldo Kurniawan ◽  
Bayu Prestianto

Quality control becomes an important key for companies in suppressing the number of defective produced products. Six Sigma is a quality control method that aims to minimize defective products to the lowest point or achieve operational performance with a sigma value of 6 with only yielding 3.4 defective products of 1 million product. Stages of Six Sigma method starts from the DMAIC (Define, Measure, Analyze, Improve and Control) stages that help the company in improving quality and continuous improvement. Based on the results of research on baby clothes products, data in March 2018 the percentage of defective products produced reached 1.4% exceeding 1% tolerance limit, with a Sigma value of 4.14 meaning a possible defect product of 4033.39 opportunities per million products. In the pareto diagram there were 5 types of CTQ (Critical to Quality) such as oblique obras, blobor screen printing, there is a fabric / head cloth code on the final product, hollow fabric / thin fabric fiber, and dirty cloth. The factors caused quality problems such as Manpower, Materials, Environtment, and Machine. Suggestion for consideration of company improvement was continuous improvement on every existing quality problem like in Manpower factor namely improving comprehension, awareness of employees in producing quality product and improve employee's accuracy, Strength Quality Control and give break time. Materials by making the method of cutting the fabric head, the Machine by scheduling machine maintenance and the provision of needle containers at each employees desk sewing and better environtment by installing exhaust fan and renovating the production room.


2020 ◽  
Vol 16 (7) ◽  
pp. 831-843
Author(s):  
Yuwen Wang ◽  
Shuping Li ◽  
Liuhong Zhang ◽  
Shenglan Qi ◽  
Huida Guan ◽  
...  

Background and Objective: Kang Fu Xin liquid (KFX) is an official preparation made from the ethanol extract product from P. Americana. The present quality control method cannot control the quality of the preparation well. The aim of the present study is to establish a convenient HPLC method for multicomponents determination combined with fingerprint analysis for quality control of KFX. Methods: An HPLC-DAD method with gradient elution and detective wavelength switching program was developed to establish HPLC fingerprints of KFX, and 38 batches of KFX were compared and evaluated by similarity analysis (SA), hierarchical clustering analysis (HCA), and principal component analysis (PCA). Meanwhile, six nucleosides and three amino acids, including uracil, hypoxanthine, uric acid, adenosine, xanthine, inosine, tyrosine, phenylalanine and tryptophan in KFX were determined based on the HPLC fingerprints. Results: An HPLC method assisted with gradient elution and wavelength switching program was established and validated for multicomponents determination combined with fingerprint analysis of KFX. The results demonstrated that the similarity values of the KFX samples were more than 0.845. PCA indicated that peaks 4 (hypoxanthine), 7 (xanthine), 9 (tyrosine), 11, 13 and 17 might be the characteristic contributed components. The nine constituents in KFX, uracil, hypoxanthine, uric acid, adenosine, xanthine, inosine, tyrosine, phenylalanine and tryptophan, showed good regression (R2 > 0.9997) within test ranges and the recoveries of the method for all analytes were in the range from 96.74 to 104.24%. The limits of detections and quantifications for nine constituents in DAD were less than 0.22 and 0.43 μg•mL-1, respectively. Conclusion: The qualitative analysis of chemical fingerprints and the quantitative analysis of multiple indicators provide a powerful and rational way to control the KFX quality for pharmaceutical companies.


2014 ◽  
Vol 4 (2) ◽  
pp. 54-78
Author(s):  
Petr Adamec ◽  
Marián Svoboda

This paper deals with the results of sociological survey focused on identification of the attitudes of elderly people to further education. The research was carried out in September 2010. Experience of elderly people with further education, their readiness (determination) for further education as well as their motivation and barriers in further education were also subjects of this research. Detecting elderly population’s awareness of universities of the third age and finding out their further education preferences were an integral part of the research. Research sample consisted of citizens over 55 years living in the South Moravian region. The survey results are structured by socio-demographic features e.g.: age, sex, educational attainment etc. and provide an interesting insight into the attitudes of the target group to one of the activities that contributes to improvement of their quality of life.


Author(s):  
Henk Addink

The pivotal aim of this book is to explain the creation, development, and impact of good governance from a conceptual, principal perspective and in the context of national administrative law. Three lines of reasoning have been worked out: developing the concept of good governance; specification of this concept by developing principles of good governance; and implementation of these principles of good governance on the national level. In this phase of further development of good governance, it is important to have a clear concept of good governance, presented in this book as the third cornerstone of a modern state, alongside the concepts of the rule of law and democracy. That is a rather new national administrative law perspective which is influenced by regional and international legal developments; thus, we can speak about good governance as a multilevel concept. But the question is: how is this concept of good governance further developed? Six principles of good governance (which in a narrower sense also qualify as principles of good administration) have been further specified in a systematic way, from a legal perspective. These are the principles of properness, transparency, participation, effectiveness, accountability, and human rights. Furthermore, the link has been made with integrity standards. The important developments of each of these principles are described on the national level in Europe, but also in countries outside Europe (such as Australia, Canada, and South Africa). This book gives a systematic comparison of the implementation of the principles of good governance between countries.


2021 ◽  
Vol 14 (3) ◽  
pp. 188
Author(s):  
Ines Katzschmann ◽  
Heike Marx ◽  
Klaus Kopka ◽  
Ute Hennrich

For the PET imaging of prostate cancer, radiotracers targeting the prostate-specific membrane antigen (PSMA) are nowadays used in clinical practice. [18F]PSMA-1007, a radiopharmaceutical labeled with fluorine-18, has excellent properties for the detection of prostate cancer. Essential for the human use of a radiotracer is its production and quality control under GMP-compliance. For this purpose, all analytical methods have to be validated. [18F]PSMA-1007 is easily radiosynthesized in a one-step procedure and isolated using solid phase extraction (SPE) cartridges followed by formulation of a buffered injection solution and for the determination of its chemical and radiochemical purity a robust, fast and reliable quality control method using radio-HPLC is necessary. After development and optimizations overcoming problems in reproducibility, the here described radio-HPLC method fulfills all acceptance criteria—for e.g., specificity, linearity, and accuracy—and is therefore well suited for the routine quality control of [18F]PSMA-1007 before release of the radiopharmaceutical. Recently a European Pharmacopeia monograph for [18F]PSMA-1007 was published suggesting a different radio-HPLC method for the determination of its chemical and radiochemical purity. Since the here described method has certain advantages, not least of all easier technical implementation, it can be an attractive alternative to the monograph method. The here described method was successfully validated on several radio-HPLC systems in our lab and used for the analysis of more than 60 batches of [18F]PSMA-1007. Using this method, the chemical and radiochemical purity of [18F]PSMA-1007 can routinely be evaluated assuring patient safety.


Polymers ◽  
2021 ◽  
Vol 13 (3) ◽  
pp. 340
Author(s):  
Elisa Chiodi ◽  
Francesco Damin ◽  
Laura Sola ◽  
Lucia Ferraro ◽  
Dario Brambilla ◽  
...  

The manufacture of a very high-quality microarray support is essential for the adoption of this assay format in clinical routine. In fact, poorly surface-bound probes can affect the diagnostic sensitivity or, in worst cases, lead to false negative results. Here we report on a reliable and easy quality control method for the evaluation of spotted probe properties in a microarray test, based on the Interferometric Reflectance Imaging Sensor (IRIS) system, a high-resolution label free technique able to evaluate the variation of the mass bound to a surface. In particular, we demonstrated that the IRIS analysis of microarray chips immediately after probe immobilization can detect the absence of probes, which recognizably causes a lack of signal when performing a test, with clinical relevance, using fluorescence detection. Moreover, the use of the IRIS technique allowed also to determine the optimal concentration of the probe, that has to be immobilized on the surface, to maximize the target recognition, thus the signal, but to avoid crowding effects. Finally, through this preliminary quality inspection it is possible to highlight differences in the immobilization chemistries. In particular, we have compared NHS ester versus click chemistry reactions using two different surface coatings, demonstrating that, in the diagnostic case used as an example (colorectal cancer) a higher probe density does not reflect a higher binding signal, probably because of a crowding effect.


Sign in / Sign up

Export Citation Format

Share Document