Determination of Unsaturation in Butyl Rubber

1945 ◽  
Vol 18 (4) ◽  
pp. 887-895 ◽  
Author(s):  
John Rehner ◽  
Priscilla Gray

Abstract In a recent publication on unsaturation in Butyl rubber it was pointed out that, of the various methods that had been examined, ozone degradation at the double bonds appears to give the most reliable unsaturation data, the values based on the limiting viscosity of the degraded polymer being in reasonably good agreement with those determined by end-group analyses. This paper describes in some detail the analytical method, together with certain modifications that have been introduced with the aim of facilitating routine work. It was recognized that the earlier procedure had the disadvantage of being too time-consuming, owing mainly to the steps in which the degraded polymer solution is evaporated to dryness, and the residue redissolved in diisobutylene before the viscosity measurement. An obvious possible improvement was to develop a procedure whereby the polymer solution could be ozonized and the viscosity of the degraded solution determined directly, thus eliminating evaporation and transfer to a second solvent. It was first necessary, however, to perform the experiments described below; their significance will be explained in the sequel. A further simplification was introduced through the use of carbon tetrachloride of ordinary reagent grade instead of the highly purified solvent. While this substitution usually leads to viscosity-time curves displaying a small negative slope in the region where the purified solvent gives unchanged viscosity values, a simple extrapolation to zero time gives viscosity data that are satisfactory within the limits inherent in the method. In view of the practical requirements of the method and the magnitude of the experimental error, the extra time and effort involved in further purification of the solvent appear to be unwarranted.

Author(s):  
Brice Calvignac ◽  
Elisabeth Rodier ◽  
Jean-Jacques Letourneau ◽  
Jacques Fages

This work is focused on the development of new characterization techniques of physical and thermodynamic properties. These techniques have been validated using the binary system DMSO-CO2 for which several studies of characterization have been well documented. We focused on the DMSO-rich phase and we carried out measurements of volumetric expansion, density, viscosity and CO2 solubility at 298.15, 308.15 and 313.15 K and pressures up to 9 MPa. The experimental procedures were compared and validated with the available literature data on SC-CO2-DMSO system. We made density and CO2 solubility measurements, using respectively the vibrating tube technology and two static analytical methods. Lastly, we developed an innovative falling body viscosimeter for high pressure measurements. All the measurements made are in good agreement with the already published data in spite of very different experimental techniques. This work is a contribution to the understanding of the DMSO-CO2 binary as it implements new viscosity data. Moreover, it opens new perspectives about the determination of the properties of other systems such as polymers-CO2 and fats-CO2, which are essential for supercritical process design such as extraction, crystallization, chromatography and synthesis reaction.


1993 ◽  
Vol 39 (3) ◽  
pp. 472-476 ◽  
Author(s):  
A B Pereira ◽  
S K Nishida ◽  
J G Vieira ◽  
M T Lombardi ◽  
M S Silva ◽  
...  

Abstract Retinol-binding protein (RBP) is a low-molecular-mass protein (21 kDa), easily filtered in renal glomeruli and very efficiently reabsorbed by the proximal convoluted tubules (PCTs). In PCT dysfunction, high concentrations of RBP are found in urine. Several methods have been used to determine RBP in serum or urine. We describe the production, selection, labeling, and utilization of anti-RBP monoclonal antibodies in two- or one-step immunoenzymometric assays for the determination of RBP. The one-step assay has good precision, with within-run and between-run CVs < 6.6% and 5.9%, respectively. Comparison with radial immunodiffusion (x) showed good agreement: y = 0.068 mg/L + 0.899x (n = 24). Comparison between the one-step (y) and two-step (x) versions of the assay also showed a very good correlation: y = 212 micrograms/L + 0.910x. The one-step assay has been adopted for routine work; it detects transthyretin-bound as well as free RBP and may have clinical usefulness in evaluating the functional status of PCTs.


1969 ◽  
Vol 62 (4) ◽  
pp. 663-670 ◽  
Author(s):  
Lars Carlborg

ABSTRACT Oestrogens administered in lower doses than necessary to induce full cornification of the mouse vagina induce mucification. It was shown previously that the degree of mucification could be estimated by quantitative determination of sialic acids. A suitable parameter for oestrogen assay was the measurement of vaginal sialic acid concentration which exhibited a clear cut dose response curve. Eleven assays of various oestrogens were performed with this method. Their estimated relative potencies were in good agreement with other routine oestrogen assays. A statistically sufficient degree of precision was found. The sensitivity was of the same order, or slightly higher, than the Allen-Doisy test.


1992 ◽  
Vol 57 (9) ◽  
pp. 1879-1887 ◽  
Author(s):  
Zdeněk Palatý

The applicability of the equation derived for calculating the dynamic viscosity of ternary non-electrolyte mixtures, to the correlation of viscosity data of the H2O- K2CO3/KHCO3 system is verified in this work. It was found out that the values of dynamic viscosity obtained experimentally are in good agreement with the viscosity values calculated from this equation. The equation constants - interaction coefficients - were determined from the measurements of dynamic viscosity on mixing the basic solutions of K2CO3 and KHCO3 of known concentration. The correlation equation makes it possible to calculate viscosity of the K2CO3/KHCO3 solutions in the K2CO3 and KHCO3 concentration range from 0 to about 2.0 kmol m-3.


1967 ◽  
Vol 13 (6) ◽  
pp. 515-520 ◽  
Author(s):  
Genevieve Farese ◽  
Janice L Schmidt ◽  
Milton Mager

Abstract A completely automated analysis is described for the determination of serum calcium with glyoxal bis (2-hydroxyanil) solution (GBHA). The method is simple and precise, and the data obtained are in good agreement with results obtained by the manual GBHA procedure.


Author(s):  
Emre Kahramanoglu ◽  
Silvia Pennino ◽  
Huseyin Yilmaz

The hydrodynamic characteristics of the planing hulls in particular at the planing regime are completely different from the conventional hull forms and the determination of these characteristics is more complicated. In the present study, calm water hydrodynamic characteristics of planing hulls are investigated using a hybrid method. The hybrid method combines the dynamic trim and sinkage from the Zarnick approach with the Savitsky method in order to calculate the total resistance of the planing hull. Since the obtained dynamic trim and sinkage values by using the original Zarnick approach are not in good agreement with experimental data, an improvement is applied to the hybrid method using a reduction function proposed by Garme. The numerical results obtained by the hybrid and improved hybrid method are compared with each other and available experimental data. The results indicate that the improved hybrid method gives better results compared to the hybrid method, especially for the dynamic trim and resistance. Although the results have some discrepancies with experimental data in terms of resistance, trim and sinkage, the improved hybrid method becomes appealing particularly for the preliminary design stage of the planing hulls.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3567
Author(s):  
Beata Szymanska ◽  
Zenon Lukaszewski ◽  
Beata Zelazowska-Rutkowska ◽  
Kinga Hermanowicz-Szamatowicz ◽  
Ewa Gorodkiewicz

Human epididymis protein 4 (HE4) is an ovarian cancer marker. Various cut-off values of the marker in blood are recommended, depending on the method used for its determination. An alternative biosensor for HE4 determination in blood plasma has been developed. It consists of rabbit polyclonal antibody against HE4, covalently attached to a gold chip via cysteamine linker. The biosensor is used with the non-fluidic array SPRi technique. The linear range of the analytical signal response was found to be 2–120 pM, and the biosensor can be used for the determination of the HE4 marker in the plasma of both healthy subjects and ovarian cancer patients after suitable dilution with a PBS buffer. Precision (6–10%) and recovery (101.8–103.5%) were found to be acceptable, and the LOD was equal to 2 pM. The biosensor was validated by the parallel determination of a series of plasma samples from ovarian cancer patients using the Elecsys HE4 test and the developed biosensor, with a good agreement of the results (a Pearson coefficient of 0.989). An example of the diagnostic application of the developed biosensor is given—the influence of ovarian tumor resection on the level of HE4 in blood serum.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 930
Author(s):  
Fahimeh Hadavimoghaddam ◽  
Mehdi Ostadhassan ◽  
Ehsan Heidaryan ◽  
Mohammad Ali Sadri ◽  
Inna Chapanova ◽  
...  

Dead oil viscosity is a critical parameter to solve numerous reservoir engineering problems and one of the most unreliable properties to predict with classical black oil correlations. Determination of dead oil viscosity by experiments is expensive and time-consuming, which means developing an accurate and quick prediction model is required. This paper implements six machine learning models: random forest (RF), lightgbm, XGBoost, multilayer perceptron (MLP) neural network, stochastic real-valued (SRV) and SuperLearner to predict dead oil viscosity. More than 2000 pressure–volume–temperature (PVT) data were used for developing and testing these models. A huge range of viscosity data were used, from light intermediate to heavy oil. In this study, we give insight into the performance of different functional forms that have been used in the literature to formulate dead oil viscosity. The results show that the functional form f(γAPI,T), has the best performance, and additional correlating parameters might be unnecessary. Furthermore, SuperLearner outperformed other machine learning (ML) algorithms as well as common correlations that are based on the metric analysis. The SuperLearner model can potentially replace the empirical models for viscosity predictions on a wide range of viscosities (any oil type). Ultimately, the proposed model is capable of simulating the true physical trend of the dead oil viscosity with variations of oil API gravity, temperature and shear rate.


Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3627
Author(s):  
Nikola Sakač ◽  
Dubravka Madunić-Čačić ◽  
Dean Marković ◽  
Lucija Hok ◽  
Robert Vianello ◽  
...  

A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a crucial contribution of the C–H∙∙∙π contacts for the optimal complex formation. The DHBI-TPB sensor potentiometric response showed excellent analytical properties and Nernstian slope for SDS (60.1 mV/decade) with LOD 3.2 × 10−7 M; and DBS (58.4 mV/decade) with LOD 6.1 × 10−7 M was obtained. The sensor possesses exceptional resistance to different organic and inorganic interferences in broad pH (2–10) range. DMIC used as a titrant demonstrated superior analytical performances for potentiometric titrations of SDS, compared to other tested cationic surfactants (DMIC > CTAB > CPC > Hyamine 1622). The combination of DHBI-TPB sensor and DMIC was successfully employed to perform titrations of the highly soluble alkane sulfonate homologues. Nonionic surfactants (increased concentration and number of EO groups) had a negative impact on anionic surfactant titration curves and a signal change. The DHBI-TPB sensor was effectively employed for the determination of technical grade anionic surfactants presenting the recoveries from 99.5 to 101.3%. The sensor was applied on twelve powered samples as well as liquid-gel and handwashing home care detergents containing anionic surfactants. The obtained results showed good agreement compared to the outcomes measured by ISE surfactant sensor and a two-phase titration method. The developed DHBI-TPB surfactant sensor could be used for quality control in industry and has great potential in environmental monitoring.


Sign in / Sign up

Export Citation Format

Share Document