scholarly journals The comparison of cyclic fatigue resistance of two different reciprocal files according to different access angles into the root canal

2021 ◽  
Vol 11 (Suppl. 1) ◽  
pp. 114-121
Author(s):  
Mehmet Dundar ◽  
Özkan Adıgüzel ◽  
Sadullah Kaya

Aim: Root canal preparation is one of the most important steps of root canal treatment. Preparation procedure includes disinfection and shaping protocols. Ni-Ti rotary file systems are usually used for shaping. The biggest disadvantage of the usage of Ni-Ti rotary file systems is that the file gets broken during the treatment. There are many reasons for the breakage of files. One of the reasons may be the increase in the access angle. The purpose of this study is to compare the cyclic fatigue of reciprocating Reciproc and WaveOne Gold rotary systems according to different angles of accessing the root canal of Ni-Ti files. Methodology: In our study, 90 root canal files were used, 45 of which is Reciproc R25 (VDW GmbH, Munich, Germany) and the other 45 of which is WaveOne Gold Primary 25/07 (Dentsply, Maillefer, Ballaigues, Switzerland). Specially designed and manufactured stainless steel artificial roots whose curvature angle is 60° and curvature radius is 5 mm, which replicates the clinical conditions, were arranged. By enabling the files access the roots at 0°- 15°- 30° degrees, the lap numbers that they do till they break due to cyclic fatigue were examined. Results: When looking at the lap numbers that the Reciproc and WaveOne Gold root canal files do till they break, at accessing the roots at the same angles WaveOne Gold root canal file makes more lap numbers at all angles when compared with the Reciproc root canal file. Significant results were found when the groups were compared within one another and between groups and among all numeric data in the statistical analysis performed. It was also found that WaveOne Gold root canal file had more cyclic fatigue resistance. When the groups were compared within one another, it was found that the increase in the root access angle decreases the cyclic fatigue resistance of the files (p<0.05). No significant difference was found in the statistical analysis for comparison of the length of the broken file pieces (p=0.01). It was analyzed that when the broken files were examined via scanning electron microscope, file breakages occurred due to cyclic fatigue. Conclusion: Not only do the design features and production technology affect the breakage resistance due to cyclic fatigue of the root canal, the access angle to the roots affects the cyclic fatigue of the root canal files, as well.   How to cite this article: Adıgüzel Ö, Dundar M, Kaya S. The comparison of cyclic fatigue resistance of two different reciprocal files according to different entry angles into the root canal. Int Dent Res 2021;11(Suppl.1):114-21. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.18   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.

2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Pooja D. Khandagale ◽  
Prashant P. Shetty ◽  
Saleem D. Makandar ◽  
Pradeep A. Bapna ◽  
Mohmed Isaqali Karobari ◽  
...  

Introduction. The main aims of root canal instrumentation are to provide an environment that will lead to healing and to provide a root canal shape that is comfortable to clean and seal. When working with rotary endodontic instruments, the most significant concerns are that the instrument might fracture in the root canal, thus affecting the treatment outcome. Hence, it is of immense importance to know which file systems have more cyclic fatigue resistance. Methodology. This study evaluated the effect of the curved segment length of the artificial canal (the arch), and the number of cycles necessary in fracture of Hyflex EDM, Twisted files, and ProTaper Gold were recorded. Sixty NiTi rotary instruments of 25 mm length (Hyflex EDM (20), Twisted files (20), and ProTaper Gold (20)) were tested in a metal block with simulated canal having 90° angle of curvature. The study was performed with a specific radius and degree of curvature, i.e., 8 mm radius and 90⁰ angle of curvature, and data obtained were subsequently subjected to statistical evaluation using one-way analysis of variance and Tukey’s post hoc test. Result. The Hyflex EDM (774.29) exhibited the maximum cyclic fatigue resistance compared to Twisted files (654.875) and ProTaper Gold (375.575). A statistically significant difference was observed between the tested groups. Conclusion. The Hyflex EDM files showed the highest cyclic fatigue resistance, followed by Twisted files and ProTaper Gold files.


2015 ◽  
Vol 03 (01) ◽  
pp. 012-019
Author(s):  
Ankita Sood ◽  
Varun Jindal ◽  
Ajay Chhabra ◽  
Arvind Arora ◽  
Ankur Vats

Abstract Aim: The aim of this study was to evaluate the apical transportation, centering ability and cyclic fatigue resistance of Hero shaper, Twisted file, Hyflex file and RACE rotary file systems. Methods: Mesiobuccal roots of eighty maxillary molars were divided into four groups and instrumented with Hero shaper, Twisted file, Hyflex file and RACE rotary file systems with a final apical size being 25/.04. Apical deviation was assessed by the radiographic platform method that enables obtaining superimposed images of the first and last instrument used in root canal preparation in the same radiograph. Apical transportation was measured in millimeters with the aid of the AUTOCAD 2008 software. Forty canals were sectioned at 7mm from the apex and stereomicroscopic Images were taken at 6x magnification before and after instrumentation for evaluation of centering ability. The cyclic fatigue testing was conducted with the instrumentrotating freely at angles of curvature of 45 degree. Total 10 instruments were tested in each group. The instruments were rotated at 400rpm using the X-smart motor (Dentsply, Maillefer) until fracture occurred. Results: There was no statistically significant difference between the four groups in apical transportation and centering ability whereas twisted files showed the maximum cyclic fatigue resistance. Conclusion: The different rotary file systems provided minimum canal transportation and the twisted file performed significantly better in terms of cyclic fatigue resistance.


2019 ◽  
Vol 13 (1) ◽  
pp. 57-60
Author(s):  
Damla Özsu Kırıcı ◽  
Ertuğrul Karataş ◽  
Ahmet Demirhan Uygun ◽  
Ezgi Doğanay Yıldız ◽  
Kezban Meltem Çolak ◽  
...  

Background. The aim of the present study was to compare the cyclic fatigue resistance of novel nickel titanium rotary pathfinding instruments. Methods. Twenty instruments were selected for each file system. A simulated stainless steel root canal, with a 90° angle of curvature and a curvature radius of 3 mm, was used for cyclic fatigue test of the ProGlider (#16, progressive taper: 0.02‒ 0.085), PathGlider (#15, taper: .03), and One G (#14, taper: .03) instruments. Statistical analyses were performed with oneway ANOVA (P=0.05). Post hoc Tukey tests were used to determine any statistically significant differences between the groups. Results. The ProGlider instruments exhibited significantly more cyclic fatigue resistance than both PathGlider and One G instruments (P<0.001). One G instruments had significantly more resistance to fracture than PathGlider instruments (P<0.05). Conclusion. ProGlider instruments had better cyclic fatigue resistance than PathGlider and One G instruments.


2021 ◽  
Vol 11 (Suppl. 1) ◽  
pp. 67-73
Author(s):  
Ahmet Akay ◽  
Özkan Adıgüzel ◽  
Seda Erkan Akay ◽  
Sadullah Kaya

Aim: The purpose of this in vitro study is to compare the cyclic fatigue resistance of Reciproc Nickel-Titanium (Ni-Ti) rotary files while operating root canals using in three different reciprocal angles. Methodology: Forty-five pieces of Reciproc R25 canal files were tested using artificial canals with a 60° angle of curvature, 5 mm curvature radius, and 1.5 mm diameter carved into a stainless steel block. The Ni-Ti files were checked with a stereomicroscope and then randomly separated into 3 groups. Group 1 consisted of reciprocal angles CCW 150°–CW 30°, Group 2 consisted of CCW 180°–CW 60°, and Group 3 consisted of CCW 210°–CW 90°. The duration of the cyclic fatigue being measured, elapsed time until a file fractured was determined with a chronometer. The lengths of the fractured pieces were measured with a digital caliper. After the cyclic fatigue test, two samples from each group were examined with a Scanning Electron Microscope (SEM) to determine the signs of cyclic fatigue. Results: One-way analysis of variance (ANOVA) was applied to the normally distributed groups (p<0,05). Since there was a significant statistical difference of file’s cyclic fatigue resistance (p=0,001) between the groups, Tukey’s honestly significant difference (HSD) post-hoc pairwise comparison test were used for determine to between which groups. While there were statistically significant differences between Group 1 and Group 2 (p=0,001), and between Group 1 and Group 3 (p=0,001), there was no significant difference between Group 2 and Group 3 (p=0,376). Group 1 displayed the highest resistance to cyclic fatigue. There were no statistically significant differences between the lengths of the fractured files within the three groups according to the one-way analysis of variance (p=0,847). Conclusion: In our study, it was observed that the reciprocal angles of CCW 150°–CW 30°, which were also suggested by the file manufacturer firms, had the highest fracture resistance against cyclic fatigue.   How to cite this article: Akay A, Adıgüzel Ö, Erkan Akay S, Kaya S. Comparison of cyclic fatigue of a reciprocating file system at different angles of rotation. Int Dent Res 2021;11(Suppl.1):67-72. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.11   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2256
Author(s):  
Giusy Rita Maria La Rosa ◽  
Valeria Shumakova ◽  
Gaetano Isola ◽  
Francesco Indelicato ◽  
Calogero Bugea ◽  
...  

Background: To compare the influence of different temperatures and curvature radii on the cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC) single file nickel-titanium rotary instruments. Methods: A total of 120 instruments of F6ST and OC #25.06 were evaluated in 5 mm and 3 mm curvature radii at two temperatures (20 °C ± 1 °C and 37 °C ± 1 °C) in 16 mm stainless steel artificial canals associated with a curvature of 60°. The cyclic fatigue of tested files was assessed by employing a customized testing apparatus and expressed as times to fracture (TtF). A statistical analysis was performed with the significance level set at 95%. Results: All instruments decreased their TtF at 37 °C except for OC in the 3 mm radius, in which no significant difference was detected between 20 °C and 37 °C. A 3 mm curvature radius negatively affected TtF of all tested instruments, except for F6ST at 20 °C. F6ST had higher TtF than OC in the 3 mm radius at 20 °C, with no significant difference between them in the other tested conditions. Conclusions: Under the limits of the present in vitro study, body temperature impaired cyclic fatigue resistance of all files, except for OC in the 3 mm curvature radius. All instruments exhibited lower times to fracture in the 3 mm radius, excluding F6ST at 20 °C.


2021 ◽  
Vol 11 (1) ◽  
pp. 16-22
Author(s):  
Neslihan Büşra Keskin ◽  
Selen İnce Yusufoğlu

Aim: To compare the effectiveness of two preparation systems and two irrigation techniques in calcium hydroxide removal from straight root canals. Methodology: Forty-four mandibular premolar teeth were included in this study. The teeth were filled with a calcium hydroxide-based paste and randomly divided into two different preparation groups (Reciproc 50 (R50; VDW, Munich, Germany and ProTaper Universal F5 (PTU; Dentsply Maillefer, Ballaigues, Switzerland). Subsequently, the groups were divided into two subgroups and irrigated using EDDY (VDW, Munich, Germany) and CanalBrush (CB; Roeko, Langenau, Germany) irrigation activation systems. The percentage of calcium hydroxide removed from the canal walls was analyzed using a dental operating microscope (DOM) at 25× magnification. An independent samples t-test, a Mann–Whitney U, Wilcoxon’s tests were used for statistical analysis. Results: There was no significant difference in calcium hydroxide removal throughout the root canal using the R50 and PTU F5 preparation systems (P = 0.847). Both activation systems significantly increased the amount of calcium hydroxide removed from the root canal. Conclusions: EDDY and CB significantly improved calcium hydroxide removal. There was no significant difference between the R50 and PTU F5 systems in calcium hydroxide removal. How to cite this article: Keskin NB, İnce Yusufoğlu S. Evaluation of the effectiveness of reciprocal and conventional shaping systems and EDDY and CanalBrush activation systems in calcium hydroxide removal. Int Dent Res 2021;11(1):16-22. https://doi.org/10.5577/intdentres.2021.vol11.no1.4   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


2020 ◽  
Vol 10 (2) ◽  
pp. 55-59
Author(s):  
Mehmet Adıgüzel ◽  
Faruk Öztekin

Aim: To evaluate the fracture resistance to cyclic fatigue of One Curve (Micro-Mega, Besancon, Cedex, France), One Shape (Micro-Mega), 2Shape (Micro-Mega) and EdgeFile X3 (EdgeEndo, Albuquerque, NM) files in simulated root canals. Methodology: One hundred and sixty nickel-titanium endodontic files were tested in simulated canals with single and s-shaped (double) curvatures. The One Curve (25/.06), One Shape (25/.06), 2Shape (25/.06) and EdgeFile X3 (25/.06) files were assessed (n=20 for each test). All the files were rotated up to fracture occurred. The number of cycles to fracture (NCF) was determined and also, the length of the fractured file part was measured. For statistical analysis, one-way analysis of variance and Tukey HSD tests were used (p < 0.05).   Results: NCF for all instrument groups were significantly higher in the single curvature canal compared to the s-shaped curvature canal (p < 0.05). The EdgeFile X3 had the highest fatigue resistance in both curvature groups. The NCF of the One Curve were higher than that of the One Shape and 2Shape files (p < 0.05). In the s-shaped curvature canal, the files inclined to fracture more often in the apical curvature compared to the coronal curvature. There was no statistically considerable difference in the length of the fractured parts among the four experiment groups in either the single or s-shaped canal curvatures (p > 0.05). Conclusion: Within the limitations of this study, fracture resistance to cyclic fatigue was the highest for the EdgeFile X3 group followed by the One Curve group and lowest for the 2Shape and One Shape group.   How to cite this article: Adıgüzel M, Öztekin F. Comparison of the resistance to cyclic fatigue of One Curve, One Shape, 2Shape and EdgeFile X3 Files in simulated single and S-shaped (double) curvatures. Int Dent Res 2020;10(2):55-59. https://doi.org/10.5577/intdentres.2020.vol10.no2.5   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


2019 ◽  
Vol 18 ◽  
pp. e191208
Author(s):  
Luís César Brisighello ◽  
George Táccio de Miranda Candeiro ◽  
Luiza Riomar Paz ◽  
Hermano Camelo Paiva ◽  
Giulio Gavini

Aim: The aim of present study was to evaluate if the cross-section and the number of use have influence in cyclic fatigue resistance of rotary files. Methods: K3 Endo (group K) and EndoSequence (group E) files, 25/.04, 25 mm, were subdivided into 3 subgroups (n=12) according to the number of uses, 1, 3 and 5 uses, totalizing 72 files. The files were submitted to dynamic assays device moved by an electric engine, using 300 rpm of speed that permitted the reproduction of pecking motion. The files run within a temperate steel ring’s groove, simulating an instrumentation of a curved root canal with 40-degrees and 5-mm of curvature radius. The fracture of file was detected by sensor of device and the time and the number of cycles was acquired. The data were analyzed statistically by two-way ANOVA (p<0.05). Results: There were no statistical significant differences in regard to the number of uses (p>0.05). K3 Endo files showed greater resistance to cyclic fatigue than EndoSequence instruments (p<0.01). Conclusion: It may be concluded that the cross-section of instruments presented significant influence in cyclic fatigue resistance and the number of uses up to 5 times had no influence in cyclic fatigue resistance in both NiTi rotation systems evaluated.


2021 ◽  
Vol 19 ◽  
pp. 228080002098740
Author(s):  
Haiyun Liu ◽  
Yanfeng Li ◽  
Guangquan Chai ◽  
Yuan Lv ◽  
Changjian Li ◽  
...  

Objective: To evaluate the effect of synchronous water irrigation on the fatigue resistance of nickel-titanium instrument. Methods: A standardized cyclic fatigue test models were established, and five types of nickel-titanium instruments (PTU F1, WO, WOG, RE, and M3) were applied. Each instrument was randomly divided into two groups ( N = 12). There was synchronous water irrigation in the experimental group, and no water irrigation in the control group. Besides, ProTaper Universal F1 was randomly divided into 10 groups ( N = 20). In the static group, nickel-titanium instruments were divided into one control group (no irrigation, N = 20) and six experimental group (irrigation, N = 20) based on different flow rate, angle and position; while in the dynamic group, instruments were divided into one control group (no irrigation, N = 20) and two experimental group (irrigation, N = 20) based on different flow rate. The rotation time (Time to Failure, TtF) of instruments was recorded and analyzed. Results: According to the static experiments, the TtF of instruments in all experimental groups was significantly higher than that in the static control group. Besides, the dynamic tests of PTU F1 showed that the TtF in the experimental group was significantly higher than that in the dynamic control group. Compared with control group, the TtF in the experimental groups increased by at least about 30% and up to 160%. The static and dynamic tests of PTU F1 showed that the TtF of nickel-titanium instrument in all experimental groups was significantly higher than that in the control group. However, there was no significant difference between any two experimental groups. Conclusion: Regardless of dynamic or static model, TtF with irrigation was longer than that with non-irrigation, indicating that synchronous irrigation can increase the fatigue resistance of nickel-titanium instrument. However, different irrigation conditions may have the same effect on the fatigue resistance.


Author(s):  
L.S. Priyanka ◽  
Lakshmi Nidhi Rao ◽  
Aditya Shetty ◽  
Mithra N. Hegde ◽  
Chitharanjan Shetty

Abstract Introduction The outcomes of oral health conditions and therapy for those conditions are described by the term “oral health-related quality of life.” Oral health-related quality of life is recognized by the World Health Organization as an important part of the Global Oral Health Program. The study aims to compare the impact of three root canal preparation systems on patients’ quality of life and correlate postoperative pain with the impact on the quality of life. Materials and Methods A survey was performed in which 90 patients were randomly assigned to three groups based on the root canal preparation system: (1) ProTaper Gold (Dentsply, Tulsa Dental Specialties, Tulsa, Oklahoma, United States), (2) Neoendo flex (Neoendo, India),and (3) Hyflex EDM/CM (Coltene Whaledent) that included 30 participants in each group. Data collection included the implementation of a demographic data questionnaire, Oral Health Impact Profile 14 (quality of life), and visual analogue scale(pain). The questionnaire was given after root canal treatment in the first 24 hours. The data obtained were statistically analyzed. Results No significant differences were found in the quality of life among study groups. Group 1 demonstrated a highly significant difference in the postoperative pain with p value of 2.67. Conclusion Within the limitations of the present study, Protaper Gold showed a highly significant difference in postoperative pain when compared with other file systems. No significant differences were found in the quality of life among the study groups.