scholarly journals Rebars for Durable Concrete Construction: Points to Ponder

2021 ◽  
Author(s):  
Anil K. Kar

Reinforced concrete is the number one medium of construction. It is important to have good quality concrete and reinforcing bar (rebar). It is equally important to have competent bond between rebar and concrete. About six decades ago ribbed rebars of high strength steel started replacing plain round bars of mild steel, the use of which had made reinforced concrete constructions durable. It was overlooked that ribbed rebars of carbon steel would be highly susceptible to corrosion at accelerated rates. That would not only make reinforced concrete constructions reach states of distress early, that could also destroy or reduce bond between ribbed rebars and concrete. The continued use of ribbed rebars of high strength carbon steel demonstrates a widespread lack of understanding of the phenomenon of bond between rebars and concrete. This lack of understanding of bond has led to the introduction of epoxy coated ribbed rebars, ribbed stainless steel bars and glass fiber reinforced and granite reinforced polymer rebars, all of which permit reinforced concrete carry static loads because of engagement between such rebars and concrete. But the load-carrying capacity of reinforced concrete elements is impaired, and such elements become vulnerable to local or even total failure during vibratory loads. The use of PSWC-BAR, characterized by its plain surface and wave-type configuration, permits the use of medium strength and high strength steel. In the absence of ribs, the rate of corrosion is greatly reduced. The use of PSWC-BARs, at no added effort or cost, in lieu of conventional ribbed bars, leads to enhancement of effective bond or engagement between such rebars and concrete, thereby leading to increased load-carrying capacity, several-fold higher life span, ductility and energy-absorbing capacity, and great reduction in life cycle cost and adverse impact of construction on the environment and the global climate. In keeping with a lack of understanding of bond between rebars and concrete, there is arbitrariness in the selection of the required level of percent elongation and ductility of rebars.

2015 ◽  
Vol 2 (1) ◽  
Author(s):  
N. Aravind ◽  
Amiya K. Samanta ◽  
Dilip Kr. Singha Roy ◽  
Joseph V. Thanikal

AbstractStrengthening the structural members of old buildings using advanced materials is a contemporary research in the field of repairs and rehabilitation. Many researchers used plain Glass Fiber Reinforced Polymer (GFRP) sheets for strengthening Reinforced Concrete (RC) beams. In this research work, rectangular corrugated GFRP laminates were used for strengthening RC beams to achieve higher flexural strength and load carrying capacity. Type and dimensions of corrugated profile were selected based on preliminary study using ANSYS software. A total of twenty one beams were tested to study the load carrying capacity of control specimens and beams strengthened with plain sheets and corrugated laminates using epoxy resin. This paper presents the experimental and theoretical study on flexural strengthening of Reinforced Concrete (RC) beams using corrugated GFRP laminates and the results are compared. Mathematical models were developed based on the experimental data and then the models were validated.


Author(s):  
Aizoh Kubo

Some typical examples of failure of gears made from very high strength steel are shown and its trigger and whose causes are discussed: Many of such failure are triggered by tooth side edge contact or tooth tip edge contact and meshing-in of the wear debris. The limit of validity of the traditional methods for load carrying capacity of gears exists in the fact that they are based on the theory of contact of tooth flanks that realize conjugate or almost conjugate action of gears. To be able to design reliable gears made from very high strength steel, a principle is shown that suggests a new method for tooth form modification and of longitudinal crowing modification to avoid such failure. Metallurgical problem of gear material and special heat treatment aiming high surface hardness is also discussed.


2019 ◽  
Vol 22 (13) ◽  
pp. 2771-2784 ◽  
Author(s):  
Yang Wei ◽  
Xunyu Cheng ◽  
Gang Wu ◽  
Maojun Duan ◽  
Libin Wang

The use of high-strength steel wires is proposed to provide external confinement for concrete-filled steel tubular columns. This article presents an experimental study on high-strength steel-wire-confined concrete-filled steel tubular columns with various high-strength steel wire spacings and steel tube thicknesses and diameters. As observed from the experimental results, high-strength steel wires can effectively constrain and delay the local buckling of the steel tube in concrete-filled steel tubular columns. As a result, the load-carrying capacity and the post-peak stiffness of concrete-filled steel tubular columns are significantly increased by the high-strength steel wire confinement. When the spacing of the high-strength steel wires decreases, the load–axial strain response can evolve from a softening behavior to a hardening behavior for the concrete-filled steel tubular columns. Moreover, theoretical models were developed to predict the load-carrying capacity of the externally confined concrete-filled steel tubular columns, taking into account the mechanical mechanism and the triaxial stress state of the inner concrete. The analytical results are generally in reasonable agreement with the experimental results.


Author(s):  
Paolo Foraboschi

Renovation, restoration, remodeling, refurbishment, and retrofitting of build-ings often imply modifying the behavior of the structural system. Modification sometimes includes applying forces (i.e., concentrated loads) to beams that before were subjected to distributed loads only. For a reinforced concrete structure, the new condition causes a beam to bear a concentrated load with the crack pattern that was produced by the distributed loads that acted in the past. If the concentrated load is applied at or near the beam’s midspan, the new shear demand reaches the maximum around the midspan. But around the midspan, the cracks are vertical or quasi-vertical, and no inclined bar is present. So, the actual shear capacity around the midspan not only is low, but also can be substantially lower than the new demand. In order to bring the beam capacity up to the demand, fiber-reinforced-polymer composites can be used. This paper presents a design method to increase the concentrated load-carrying capacity of reinforced concrete beams whose load distribution has to be changed from distributed to concentrated, and an analytical model to pre-dict the concentrated load-carrying capacity of a beam in the strengthened state.


2021 ◽  
Vol 28 (1) ◽  
pp. 71-83
Author(s):  
Mazin Abdulrahman ◽  
Shakir Salih ◽  
Rusul Abduljabbar

In this research, an experimental study is conducted to investigate the behavior and strength of high strength reinforced concrete corbels externally bonded with CFRP fabric sheets and Plates with different patterns taking into account the effect of adopted variables in enhancing the ultimate strength; the effect of shear span to effective depth (a/d), configuration, type and amount of bonding. Eleven high strength reinforced corbels were cast and tested under vertical loads. Test results showed there was an improvement in the behavior and load carrying capacity of all strengthened corbels. An increasing in the ultimate strength of strengthened corbel by inclined CFRP strips reached to (92.1%) while the increasing reached to (84.21%) for using one horizontal CFRP Plates compared to un-strengthened reference specimen. Also, it can be conducted that the increase of (a/d) ratio from (0.6 to 0.8) resulted in decreasing by 21.05% in ultimate load capacity of corbels and from (0.4 to 0.6) by 31.25% and 58.69% in cracking and ultimate loads respectively Using CFRP .