scholarly journals Effect of Different Food Coloring Additives on the Color Stability of Microabraded, at-Home Bleached and Resin Infiltrated Tooth

Author(s):  
B. Nilopher Sherin ◽  
Thendral Began ◽  
I. Anand Sherwood ◽  
Bennett T. Amaechi ◽  
A. Andamuthu Sivakumar ◽  
...  

Objective: Color stability of at-home bleaching and resin infiltration is one of the main goals of these procedures. The primary aim of present study was to evaluate color stability of at-home bleaching and resin infiltration to four common colorants present in Indian foods (turmeric, beetroot, coffee and artificial food colorants). Materials and Methods: 128 human maxillary central incisors were used in this study. Teeth were randomly divided into groups as (i) subjected and (ii) not-subjected to microabrasion. Further, the teeth in each group (abraded/non-abraded) were randomly distributed to four subgroups (16 teeth/subgroup). Subgroups were control, bleached, combined treatment with at-home bleaching followed by resin infiltration and infiltrated. After treatment procedures the teeth were immersed in the four different food colorants. Objective photographic color change evaluation from pre-/ post staining was done using the CIEDE2000 formula. Statistical Analyses: Data were analyzed using parametric and nonparametric tests (α =0.05). Results: Turmeric solution caused significantly (P < 0.05) highest post-staining values b*and ΔE values in Combine-Rx group and Infiltration groups. Conclusions: Subsequent discoloration of esthetically treated teeth does not necessarily depend on the type of treatment but on the coloring additives present in the diet, of which turmeric has the highest discoloration potential. Clinical Significance: Turmeric is one of the essential ingredients in Indian foods therefore, both patients and operator must be aware that resin infiltrated teeth can discolored from regular diets that contains turmeric as coloring additives.

2016 ◽  
Vol 17 (5) ◽  
pp. 377-381 ◽  
Author(s):  
Priyanshi Ritwik ◽  
Christopher M Jones ◽  
Yuwei Fan ◽  
Nikhil K Sarkar

ABSTRACT Aims Resin infiltration is an emerging technique for management of noncavitated lesions. This study evaluated the in vitro hydrolytic and color stability of the ICON® resin infiltration system (IC) in 42 extracted human teeth. Materials and methods ICON® resin infiltration system was compared with dental adhesive (DA) and dental sealant (DS). The products were applied according to manufacturer's instructions. The baseline weight and color of the samples were recorded. Color was recorded by spectoral colorimeter. The samples were subjected to four experimental conditions: (1) group 1: Stored in lactic acid solution (pH 4.9) for 24 hours; (2) group 2: Thermocycled for 100 cycles (temperatures: 5°C, 55°C, and dwell time of 15 seconds); (3) group 3: Stored in 0.1 N sodium hydroxide solution (pH 12.48) for 14 days at 60°C; (4) group 4: Stored in phosphate-buffered saline solution (pH 7.2) at 37°C for 4 months. The weight and color were recorded again after removal of the samples from the experimental conditions. Two-factor analysis of variance models and Tukey's Honestly Significant Difference were performed to assess statistical differences among the groups. Scanning electron microscopy imaging was performed for samples from groups 1, 3, and 4. Results All the samples showed loss of material and change in color. In the demineralizing solution, IC showed significantly greater weight loss (p = 0.032) and color change (p = 0.038) compared with DA. Dental Sealant showed significantly greater weight loss than IC (p = 0.027) after thermocycling. Teeth in group 3 exhibited the greatest weight loss (p < 0.001). Teeth in group 2 exhibited the greatest color change (p < 0.001). Conclusion All tested materials showed loss of retention and color change in the experimental conditions. Infiltration system exhibited greatest weight loss and color change in demineralizing solution. Dental sealant exhibited greatest weight loss upon thermocycling. Clinical significance Clinicians should be cautious about the limitations of retention and color stability when considering resin infiltration for incipient lesions. How to cite this article Ritwik P, Jones CM, Fan Y, Sarkar NK. Hydrolytic and Color Stability of Resin Infiltration: A Preliminary in vitro Trial. J Contemp Dent Pract 2016;17(5):377-381.


2016 ◽  
Vol 41 (4) ◽  
pp. 388-396 ◽  
Author(s):  
M Rezende ◽  
L Ferri ◽  
S Kossatz ◽  
AD Loguercio ◽  
A Reis

SUMMARY Objectives: The aim of this study was to evaluate the efficacy, color stability, risk, and intensity of tooth sensitivity (TS) of combined bleaching techniques performed with 20% or 35% hydrogen peroxide for an in-office protocol. Methods: Thirty patients were randomly divided into two groups and submitted to a single 45-minute in-office bleaching session with 35% hydrogen peroxide or 20% hydrogen peroxide. At-home bleaching was performed with 10% carbamide peroxide for two hours daily over the course of two weeks. The color was evaluated with the value-oriented shade guide Vita Classical at different periods up to 12 months after bleaching. Patients recorded the intensity of TS using a five-point verbal scale. Color change data were submitted to a two-way repeated-measures analysis of variance and Tukey test (α=0.05). The absolute risk and intensity of TS were compared with the Fisher exact test and Mann-Whitney test, respectively (α=0.05). Results: On average, an effective and similar whitening of three units in shade guide was observed for both groups, which remained stable for 12 months. When both protocols were compared, the one with hydrogen peroxide 35% showed a higher risk (p=0.02) and intensity of TS (p=0.04). In regard to the TS intensity, no significant difference was observed up to 48 hours after in-office bleaching (p=0.09) and during the at-home bleaching phase of the study (p=0.71). Conclusion: The combined bleaching technique using at-home bleaching associated with in-office bleaching was effective and stable over the course of 12 months, regardless of the concentration of the hydrogen peroxide used for in-office bleaching. However, the protocol with 20% hydrogen peroxide produced lower risk and intensity of TS.


2014 ◽  
Vol 39 (4) ◽  
pp. 433-440 ◽  
Author(s):  
AB Borges ◽  
TMF Caneppele ◽  
M Luz ◽  
CR Pucci ◽  
CRG Torres

SUMMARY Purpose The aim of this study was to investigate the staining behavior of demineralized enamel infiltrated by low-viscosity resin. Methods and Materials Bovine enamel/dentin cylindrical samples (3 × 2 mm) were assigned into four groups (n=45) according to the enamel treatment: sound enamel (control), demineralization + artificial saliva, demineralization + daily application of 0.05% NaF, demineralization + resin infiltration (Icon, DMG). Artificial white spot lesions were produced in groups with demineralization. After the treatments, color was assessed by spectrophotometry, using the CIE L*a*b* system. The specimens (n=15) were then immersed in deionized water, red wine, or coffee for 10 minutes daily for eight days. Color was measured again, and the specimens were repolished with sandpaper discs. The final color was assessed. Data were analyzed by two-way analysis of variance and Tukey tests (α=0.05). A paired t-test was used for comparison between staining and repolishing conditions. Results There were significant differences for surface treatment and dye after staining and repolishing. Immersion in wine and coffee resulted in significantly increased color alteration (ΔE) compared with water (p=0.001). The resin-infiltrated group exhibited the highest staining values (p=0.001). The repolishing procedures resulted in significantly decreased color change. Conclusion The exposure of specimens to colored solutions resulted in significant color alteration. The demineralized enamel treated with resin infiltration showed significantly higher staining than all other tested groups; however, the repolishing of the specimens minimized the staining effect.


2014 ◽  
Vol 1 (1) ◽  
pp. 24-34
Author(s):  
Alireza K. ◽  
Hossein Ahmadi ◽  
Mohsen Mohammadi

Lubricants and leather dressings are the most common treatments of dry and water logged historical leathers. Color change has a great importance during the time and treatment process, due to visual and aesthetic values of historic leather relics. Polyethylene glycol (PEG) and silicone oil (SiO) are frequently used leather dressings in the conservation procedures. Therefore, color stability of treated leathers with PEG and SiO were investigated before and after heat accelerated aging. Moreover, application of ascorbic acid was evaluated as an antioxidant additive for PEG (PEG+AA).Color change after treatment and aging were studied by colorimetry technique in the CIE *L*a*b system. Results indicated to severe color alteration in PEG treated and aged leathers with or without ascorbic acid. Whereas, SiO treated samples showed better stability and minimum color shift after aging. Silicone oil was characterized as the best dressing for historical leathers with compared to PEG and PEG+AA, due to its high stability and aesthetical properties.


2015 ◽  
Vol 44 (5) ◽  
pp. 262-267 ◽  
Author(s):  
José Vitor Quinelli Mazaro ◽  
Luiz Miguel Minani ◽  
Adriana Cristina Zavanelli ◽  
Caroline Cantieri de Mello ◽  
Cleidiel Aparecido Araújo Lemos

AbstractIntroductionTemporary restorative materials are widely used, however, little is know about their color stability.Objectiveto evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage.Material and methodFour materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) and 30 test specimens (15 mm in diameter and 2 mm thick) per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee) and storage time intervals (2, 5, 7 and 15 days). Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%.ResultAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767). As regards solutions tested, coffee showed the highest color change values (p<0.001), and the longer the storage time interval, the greater was the color change in all the temporary restorative materials analyzed (p<0.001).ConclusionAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.


2014 ◽  
Vol 20 (4) ◽  
pp. 1234-1239 ◽  
Author(s):  
Ana Luísa Botta Martins de Oliveira ◽  
Ana Carolina Botta ◽  
Juliana Álvares Duarte Bonini Campos ◽  
Patrícia Petromilli Nordi Sasso Garcia

AbstractThis study evaluated the influence of fluoride mouth rinses and repolishing on the superficial morphology and color stability of nanofilled resin. About 150 specimens were prepared and polished using aluminum oxide discs for 15 s with a pressure of 2 kg. The experimental groups were divided according to the immersion medium (artificial saliva, 0.5% sodium fluoride, Fluordent Reach, Oral B, Fluorgard) and repolishing procedure (without and with). The specimens were continuously immersed for 1 week. Thereafter, half of each sample was repolished. A color reading was performed after 24 h of immersion in the artificial saliva baseline, after continuous immersion, and after repolishing. The superficial morphology was examined using scanning electron microscopy (SEM) in a qualitative way. Color change (∆E) data were submitted to a mixed analysis of variance using a Shapiro–Wilk test (p>0.05 for the different immersion media) and Sidak’s test (p<0.05 for the differences between groups). In the interaction between the repolishing and the immersion media, Fluorgard showed a statistical difference between the ∆E values with and without repolishing (p<0.0001). On the SEM observations, both Fluordent Reach and Fluorgard caused degradation of the superficial resinous matrix of the composite after continuous immersion. This matrix was removed after repolishing.


2020 ◽  
Vol 14 (01) ◽  
pp. 085-091
Author(s):  
Sedighe Sadat Hashemikamangar ◽  
Farnoosh Hoseinpour ◽  
Nazanin Kiomarsi ◽  
Mehrzad Gholampour Dehaki ◽  
Mohammad Javad Kharazifard

Abstract Objectives This study aimed to assess the effect of an optical whitening toothpaste on color stability of microhybrid, nanofilled, and microfilled composite resins and resin-modified glass ionomer (RMGI) cement in comparison of two other toothpastes. Materials and Methods In this experimental study, disc-shaped composite samples were fabricated. The samples were then polished using silicon carbide papers. Twenty-seven samples of each material were fabricated and subjected to colorimetry using a spectrophotometer. Each group of material was then divided into three subgroups for the application of conventional whitening and whitening containing blue covarine toothpastes. One operator brushed the samples with an electric soft toothbrush with circular motion twice a day, each time for 30 seconds. Colorimetry was performed at 0, 1, 7, 30, and 90 days. Statistical Analysis Two-way analysis of variance (ANOVA), one-way ANOVA, and Tukey’s honestly significant difference (HSD) test were used for statistical analysis. Results The interaction effect of type of restorative material and time on ∆E was not significant at baseline or 1 day (p > 0.05). The effect of type of toothpaste on ∆E was not significant at baseline or 1 day (p = 0.78) but the effect of type of material was significant (p < 0.05). The toothpastes had significantly different effects on ∆E of Z250 at all time points (p < 0.05) except for ∆E0–30 (p = 0.106). The toothpastes had significantly different effects on ∆E of Z350 and Gradia at all time points (p < 0.05). The same was true for RMGI except for ∆E0–7 (p = 0.43) and ∆E0–90 (p = 0.52). The majority of color changes caused by toothpastes were not clinically perceivable (∆E < 3.3), except for ∆E0–90 by the whitening toothpaste (∆E = 9), ∆E0–90 by the conventional toothpaste for Z350 (∆E = 3.9), and ∆E0–1 by the whitening toothpaste for RMGI (∆E = 3.7). Conclusion The color change of all composite samples was not clinically perceivable (<3.3) at all time points, which shows that the tested toothpastes do not cause a significant change in color of composite materials.


Polymers ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 217
Author(s):  
Ladislav Dzurenda ◽  
Michal Dudiak ◽  
Eva Výbohová

The wood of maple (Acer Pseudopatanus L.) was steamed with a saturated steam-air mixture at a temperature of t = 95 °C or saturated steam at t = 115 °C and t = 135 °C, in order to give a pale pink-brown, pale brown, and brown-red color. Subsequently, samples of unsteamed and steamed maple wood were irradiated with a UV lamp in a Xenotest Q-SUN Xe-3-H after drying, in order to test the color stability of steamed maple wood. The color change of the wood surface was evaluated by means of measured values on the coordinates of the color space CIE L* a* b*. The results show that the surface of unsteamed maple wood changes color markedly under the influence of UV radiation than the surface of steamed maple wood. The greater the darkening and browning color of the maple wood by steaming, the smaller the changes in the values at the coordinates L*, a*, b* of the steamed maple wood caused by UV radiation. The positive effect of steaming on UV resistance is evidenced by the decrease in the overall color difference ∆E*. While the value of the total color diffusion of unsteamed maple wood induced by UV radiation is ∆E* = 18.5, for maple wood steamed with a saturated steam-air mixture at temperature t = 95 °C the ∆E* decreases to 12.6, for steamed maple wood with saturated water steam with temperature t = 115 °C the ∆E* decreases to 10.4, and for saturated water steam with temperature t = 135 °C the ∆E* decreases to 7.2. Differential ATR-FTIR spectra declare the effect of UV radiation on unsteamed and steamed maple wood and confirm the higher color stability of steamed maple wood.


2018 ◽  
Vol 5 (4) ◽  
pp. 76
Author(s):  
Mone Laiz Bortoli ◽  
Cristina Von Appen ◽  
Camila Longoni ◽  
Carmen Beatriz Borges Fortes ◽  
Jefferson Tomio Sanada

Aim: This work aimed to evaluate the color stability of an acrylic resin chemically activated (ARCA) using different handling techniques, and a bisacrylic resin when exposed to different pigmentation solutions.Material and Methods: Silicon matrixes were confectioned (10x10x3mm) to be used as specimens. The groups were designed as follows: Group Pot, Group Brush, Group Manufacturer and Group Bisacrylic (n=18). Each group was exposed to three different pigmentation solutions: distilled water, coke and chlorhexidine digluconate 0.12%. Three readings were performed for each specimen using a spectrophotometer, and the evaluations were carried out in three different time. After the color reading, three averages and the standard deviation of variation were performed after 24 hours (T1), 7 days (T2) and 14 days (T3). Data were submitted to the ANOVA and 2 criteria and Tukey (P<0.05) in the statistical software SSPS 18 for Macintosh (SPSS Inc., Chicago, USA).Results: When compared the solutions in each group of material, there was no statistically significant difference, except for T3, where the group Dencor Brush and Bisacrylic demonstrated higher color variation in all the solutions, even in the control group, and the values in Chlorhexidine higher than the other, showing greater instability after 14 days.Conclusions: With the results, bisacrylic resin used as provisory prosthesis material presents greater color instability than the ARCA, when submitted to different solutions. Bisacrylic resin and Dencor Brush present significantly visible color changes in chlorhexidine solution after 14 days. All the materials in coke solution present homogeneity in the color change after 7 days exposition to the solution, with no visible color change.


2017 ◽  
Vol 18 (4) ◽  
pp. 283-288 ◽  
Author(s):  
Cleidiel AA Lemos ◽  
Silvio J Mauro ◽  
Paulo H dos Santos ◽  
André LF Briso ◽  
Ticiane C Fagundes

ABSTRACT Aim The aim of this study was to investigate the association of different degradations on the roughness, gloss, and color changes of microhybrid composites. Materials and methods Ten specimens were prepared for Charisma, Amelogen Plus, Point 4, and Opallis resins. Surfaces were polished and baseline measurements of roughness, gloss, and color were recorded. Specimens were then submitted to chemical and mechanical challenges, and the specimens were reevaluated. Roughness and gloss were analyzed by Kruskal – Wallis and Dunn's test (p < 0.05). Color change (ΔE) was analyzed by one-way analysis of variance and Tukey's tests (p < 0.05). The initial and final data were compared using the Wilcoxon test (p < 0.05). Spearman test checked the correlation between the roughness and gloss (p < 0.05). Results Regarding surface roughness and gloss, there was no difference between composites before challenges. However, all composites showed a significant increase of roughness after challenges, with highest values for Charisma. The gloss was influenced by challenges, evidencing the best gloss for Point 4. Charisma showed the highest value of color change. There was no correlation between surface roughness and gloss for the initial analysis, and after the challenges. Conclusion Composites were influenced by association of challenges, and Charisma showed the highest changes for roughness, gloss, and color. Clinical significance The type of composite resin influenced the properties of materials, which are surface roughness, gloss, and color change. The dentist should be aware of the performance of different brands, to choose the correct required composite resin for each type of patient or region to be restored. How to cite this article Lemos CAA, Mauro SJ, dos Santos PH, Briso ALF, Fagundes TC. Influence of Mechanical and Chemical Degradation in the Surface Roughness, Gloss, and Color of Microhybrid Composites. J Contemp Dent Pract 2017;18(4):283-288.


Sign in / Sign up

Export Citation Format

Share Document