metallic fibers
Recently Published Documents


TOTAL DOCUMENTS

67
(FIVE YEARS 18)

H-INDEX

13
(FIVE YEARS 2)

Author(s):  
Marie Audouin ◽  
Nicolas Philippe ◽  
Fabien Bernardeau ◽  
Mariann Chaussy ◽  
Sergio Pons Ribera ◽  
...  

The use of bio-based material is now widespread in insulation concrete, for example hemp concrete. The bio-based materials in concrete provide many advantages: lightness, sound and thermal insulation, hydrothermal regulation while contributing to a reduction in the environmental impact due to the carbon capture during the plant growth. The development of materials incorporating plant is therefore an important objective for the construction. The next step will be to introduce bio-based materials in structural mortars and concretes. The project FIBRABETON proposes to substitute synthetic or metallic fibers by natural fibers in screed and slab. After a selection of biomass on the resources availability, separation and fractionation are the key step in processing to obtain technical natural fibers. Bulk fiber shaping and packaging methods for easy handling and transportation are tested. Then, functionalization of technical natural fibers by physical & chemical treatments to improve the durability with cement paste is carried out. The second step concerns the introduction of treated or not treated fibers in mortar and concrete formulations. The variation of the nature of the biomass, fibers shape and dosage in concrete are studied. The workability, the compressive strength and withdrawal resistance are measured in order to obtain the best formulation parameters. The evolution of properties over time is also evaluated. The project FIBRABETON is carried out with ESTP, FRD and Vicat and is subsidized by ADEME, Grand Est region and FEDER.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7052
Author(s):  
Sangkyu Lee ◽  
Gyuyong Kim ◽  
Hongseop Kim ◽  
Minjae Son ◽  
Yaechan Lee ◽  
...  

In this study, high-strength concrete containing hooked-end steel or amorphous metallic fibers was fabricated, and the electrical conductivity and electromagnetic shielding effectiveness were evaluated after 28 and 208 days based on considerations of the influences of the moisture content. Amorphous metallic fibers, which have the same length and length/equivalent diameter ratio as hooked-end steel fibers, were favored for the formation of a conductive network because they can be added in large quantities owing to their low densities. These fibers have a large specific surface area as thin plates. The electromagnetic shielding effectiveness clearly improved as the electrical conductivity increased, and it can be expected that the shielding effectiveness will approach the saturation level when the fiber volume fraction of amorphous metallic fibers exceeds 0.5 vol.%. Meanwhile, it is necessary to reduce the amount of moisture to conservatively evaluate the electromagnetic shielding performance. In particular, when 0.5 vol.% of amorphous metallic fibers was added, a shielding effectiveness of >80 dB (based on a thickness of 300 mm) was achieved at a low moisture content after 208 days. Similar to the electrical conductivity, excellent shielding effectiveness can be expected from amorphous metallic fibers at low contents compared to that provided by hooked-end steel fibers.


Materials ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 5403
Author(s):  
Ji-Hwan Kim ◽  
Sung-Ho Bae ◽  
Se-Jin Choi

Recently, with increasingly stringent environmental regulations and the depletion of natural aggregate resources, high-quality aggregates have become scarce. Therefore, significant efforts have been devoted by the construction industry to improve the quality of concrete and achieve sustainable development by utilizing industrial by-products and developing alternative aggregates. In this study, we use amorphous metallic fibers (AMFs) to enhance the performance of mortar with steel slag aggregate. Testing revealed that the 28-day compressive strength of the sample with steel slag aggregate and AMFs was in the range of 48.7–50.8 MPa, which was equivalent to or higher than that of the control sample (48.7 MPa). The AMFs had a remarkable effect on improving the tensile strength of the mortar regardless of the use of natural aggregates. With AMFs, the drying shrinkage reduction rate of the sample with 100% steel slag aggregate was relatively higher than that of the sample with 50% natural fine aggregate. Furthermore, the difference in the drying shrinkage with respect to the amount of AMFs was insignificant. The findings can contribute to sustainable development in the construction industry.


2021 ◽  
Vol 309 ◽  
pp. 01177
Author(s):  
K Tharun Kumar Reddy ◽  
Srikanth Koniki

Concrete is poor in tensile property due to its brittle nature. Improvement in the mechanical properties of concrete is carried by combining the rebars and fibers in concrete. Earlier research state that non-metallic fibres improve pre-crack performance and metallic fibers improve post crack performance. Short fibers resist the micro-cracks at an early stage and long fibers resist macro-cracks. The combination of short and long fibers makes the performance of concrete much effective. In this study, the investigation is done on non-metallic PVA fiber with the lengths of 6mm (Short fiber) and 12mm (Long fiber) by hybridization of fibers on 50MPa concrete. The investigation is done in two stages; in the first stage, the optimum dosage of fiber content and strength effectiveness of strengths is carried. Further, in the second stage the hybridization of fiber is done with the 30% SF + 70% LF, 50%SF + 50% LF, 70% SF + 30% LF for finding the optimum hybrid combination. Mechanical properties of concrete like flexural strength, split tensile strength, compressive strength is investigated. The results obtained by the hybridization of fibers are compared with the mono fiber performance and control mix. Improvement in strength parameters is observed in fiber hybridization. According to the fiber functionality, the hybrid combination of 30% SF + 70% LF showed desired results by improving the overall performance of concrete. More long fibers content improves the crack growth resistance than short fibers in concrete.


Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5731
Author(s):  
Alvaro González ◽  
José Norambuena-Contreras ◽  
Lily Poulikakos ◽  
María José Varela ◽  
Jonathan Valderrama ◽  
...  

This paper reports part of an international research project with the long-term aim of developing more sustainable asphalt mixture with crack-healing properties by the addition of recycled metallic waste from industrial sources. Specifically, this article presents an evaluation of the physical, thermophysical, and mechanical properties of asphalt mixtures with metallic fiber obtained from recycled tires for crack-healing purposes. Detailed results on the crack-healing of asphalt mixtures will be reported in a second article. Results showed a small reduction on the bulk density and increase in the air voids content was quantified with increasing fiber contents. The experimental results showed that mixing and compaction was more difficult for higher fiber contents due to less space for the bitumen to freely flow and fill the voids of the mixtures. Computed tomography (CT) results allowed to identify clustering and orientation of the fibers. The samples were electrically conductive, and the electrical resistivity decreased with the increase of the fiber content. Fiber content had a direct effect on the indirect tensile stiffness modulus (ITSM) and strength (ITS) that decreased with increasing temperature for mixtures and with increase in fiber content. However, the indirect tensile strength ratio (ITSR) was within acceptable limits. In short, results indicate that fibers from recycled tires have a potential for use within asphalt mixtures to promote crack-healing.


2020 ◽  
Vol 263 ◽  
pp. 120711
Author(s):  
Gyeongcheol Choe ◽  
Gyuyong Kim ◽  
Hongseop Kim ◽  
Euichul Hwang ◽  
Sangkyu Lee ◽  
...  

2020 ◽  
Vol 14 (4) ◽  
Author(s):  
Muluneh G. Abebe ◽  
Gilles Rosolen ◽  
Eric Khousakoun ◽  
Jeremy Odent ◽  
Jean-Marie Raquez ◽  
...  
Keyword(s):  

Materials ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 4562
Author(s):  
Suvash Paul ◽  
Gideon van Zijl ◽  
Branko Šavija

This article reviews the literature related to the performance of fiber reinforced concrete (FRC) in the context of the durability of concrete infrastructures. The durability of a concrete infrastructure is defined by its ability to sustain reliable levels of serviceability and structural integrity in environmental exposure which may be harsh without any major need for repair intervention throughout the design service life. Conventional concrete has relatively low tensile capacity and ductility, and thus is susceptible to cracking. Cracks are considered to be pathways for gases, liquids, and deleterious solutes entering the concrete, which lead to the early onset of deterioration processes in the concrete or reinforcing steel. Chloride aqueous solution may reach the embedded steel quickly after cracked regions are exposed to de-icing salt or spray in coastal regions, which de-passivates the protective film, whereby corrosion initiation occurs decades earlier than when chlorides would have to gradually ingress uncracked concrete covering the steel in the absence of cracks. Appropriate inclusion of steel or non-metallic fibers has been proven to increase both the tensile capacity and ductility of FRC. Many researchers have investigated durability enhancement by use of FRC. This paper reviews substantial evidence that the improved tensile characteristics of FRC used to construct infrastructure, improve its durability through mainly the fiber bridging and control of cracks. The evidence is based on both reported laboratory investigations under controlled conditions and the monitored performance of actual infrastructure constructed of FRC. The paper aims to help design engineers towards considering the use of FRC in real-life concrete infrastructures appropriately and more confidently.


Materials ◽  
2020 ◽  
Vol 13 (19) ◽  
pp. 4451
Author(s):  
Se-Jin Choi ◽  
Ji-Hwan Kim ◽  
Sung-Ho Bae ◽  
Tae-Gue Oh

This paper investigates the strength, drying shrinkage, and carbonation characteristic of amorphous metallic fiber-reinforced mortar with natural and artificial lightweight aggregates. The use of artificial lightweight aggregates has the advantage of reducing the unit weight of the mortar or concrete, but there is a concern that mechanical properties of concrete such as compressive strength and tensile strength may deteriorate due to the porous properties of lightweight aggregates. In order to improve the mechanical properties of lightweight aggregate mortar, we added 0, 10, 20, and 30 kg/m3 of amorphous metallic fibers to the samples with lightweight aggregate; the same amount of fiber was applied to the samples with natural aggregate for comparison. According to this investigation, the flow of mortar decreased as the amount of amorphous metallic fiber increased, regardless of the aggregate type. The compressive strength of lightweight aggregate mortar with 10 kg/m3 amorphous metallic fiber was similar to that of the LAF0 sample without amorphous metallic fiber after 14 days. In addition, the flexural strength of the samples increased as the amount of amorphous metallic fiber increased. The highest 28-d flexural strength was obtained as approximately 9.28 MPa in the LAF3 sample, which contained 30 kg/m3 amorphous metallic fiber. The drying shrinkage of the samples with amorphous metallic fiber was smaller than that of the sample without amorphous metallic fiber.


Sign in / Sign up

Export Citation Format

Share Document