pullout failure
Recently Published Documents


TOTAL DOCUMENTS

19
(FIVE YEARS 5)

H-INDEX

4
(FIVE YEARS 1)

PCI Journal ◽  
2021 ◽  
Vol 66 (2) ◽  
pp. 71-87
Author(s):  
Sandip Chhetri ◽  
Rachel A. Chicchi ◽  
Andrew E. N. Osborn

Very little experimental data have been published relating to the pullout capacity of prestressing strand lifting loops. To address this gap in knowledge, 13 pullout tests were conducted on strand lifting loops with 0.6 in. (15.24 mm) diameter, 270 ksi (1860 MPa) strand. Straight and bent orientations were tested for single loops at different embedment depths. Loops were embedded in 12 in. (304.8 mm) wide and 44 in. (1117.6 mm) deep concrete blocks and subjected to monotonic, static loading until failure. Marginal bond quality of the strand (18.2 kip [81 kN]), Mohs hardness (3.6), and concrete strength (3000 psi [20.7 MPa]) resulted in an average bond stress value of 400 psi (2758 kPa) at failure. Most tests exhibited pullout failure modes and adequate ductility. Three loops tested at 32 in. (812.8 mm) embedment with 6 in. (152.4 mm), 90-degree bends experienced brittle side-face blowout failures. These failures were due to inclination of the lifting, which led to a reduced edge distance. A safe uniform bond stress of 199 psi (1372 kPa) is recommended for 0.6 in. diameter strand.


Author(s):  
Lucas J Ray ◽  
Jonathan N Sembrano ◽  
David S Nedrelow

Abstract Osteoporosis is one of the most challenging diseases facing orthopedic surgery. Implants may exhibit poor bone retention due to the decreased density of osteoporotic bone, leading to mechanical failure. Our study aimed to design a pedicle screw for vertebral implantation that exhibited pullout strengths that were higher than the current industry standard screw. We created three prototypes to address pullout failure with varying numbers of helices and one design that was a two-part hybrid (triple helix and pedicle screw). Each screw was subjected to pull-out testing in foam blocks (n=3). Ultimate pull-out load, ultimate extension, and screw removal energy were determined based on testing results. Based on the results, the two-part assembly demonstrated significantly improved pull-out strength to 102.76 ± 2.52 N (P > 0.0002), ultimate extension to 8.787 ± 0.242 (P > 0.002), and screw removal energy of 2.37 ± 0.03 kJ (P > 0.0003) vs 1.66 ± .08 kJ in the control screw, and the other two screw designs. It is noteworthy that the flexible and stiff helix designs by themselves did not exhibit improved performance, but when combined into a dual-threaded screw the helix features improved performance. The results for the two-part design suggested that there is utility in this design or variations thereof for improving screw-to-bone retention in osteoporotic patients.


2020 ◽  
Vol 117 (1) ◽  
Author(s):  
Zhao Chen ◽  
Somayeh Nassiri ◽  
Anthony Lamanna ◽  
William Cofer

2019 ◽  
Vol 9 (7) ◽  
pp. 1340 ◽  
Author(s):  
Kui Gao ◽  
Zhao Li ◽  
Jiarui Zhang ◽  
Jianwei Tu ◽  
Xinping Li

This paper presents the results of a series of pullout tests that were performed on Glass-fiber-reinforced polymer (GFRP) bars embedded in concrete, while providing a detailed report on the influence of various variables that impinge upon bond behavior, such as the surface characteristics and diameter of the bars, concrete strength, as well as the confined effect of stirrups. The Bertero-Popov-Eligehausen (BPE) and Cosenza-Manfredi-Realfonzo (CMR) models analyzed the bond stress (τ)–slip (s) relationship between GFRP bar and stirrups-confined concrete. The tests results indicate that when the bond failure interface only occurs on the surface of a GFRP bar, the bond strength is not dependent upon the concrete strength. Moreover, the results indicate that in comparison to specimens without stirrups, their stirrup-containing counterparts are more prone to pullout failure with greater ductility and higher bond strength and corresponding slip. The BPE and CMR models are able to investigate the τ-s relationship between GFRP bars and the stirrups-confined concrete with accuracy. With the experimental data, the specific parameters in the models classified by surface characteristics have been suggested.


2018 ◽  
Vol 10 (7) ◽  
pp. 168781401878528 ◽  
Author(s):  
Feng Chen ◽  
Shiding Sun ◽  
Zhenwu Ma ◽  
GQ Tong ◽  
Xiang Huang

We use tensile–shear tests to investigate the failure modes of Ti–1Al–1Mn microscale resistance spot welds and to determine how the failure mode affects the microstructure, microhardness profile, and mechanical performance. Two different failure modes were revealed: interfacial failure mode and pullout failure mode. The welds that fail by pullout failure mode have much better mechanical properties than those that fail by interfacial failure mode. The results show that weld nugget size is also a principal factor that determines the failure mode of microscale resistance spot welds. A minimum weld nugget size exists above which all specimens fail by pullout failure mode. However, the critical weld nugget sizes calculated using the existing recommendations are not consistent with the present experimental results. We propose instead a modified model based on distortion energy theory to ensure pullout failure. Calculating the critical weld nugget size using this model provides results that are consistent with the experimental data to high accuracy.


2018 ◽  
Vol 199 ◽  
pp. 11007
Author(s):  
Fabien Delhomme ◽  
Michael Brun

An experimental and numerical study was completed in order to examine the mechanical behaviour of post-installed bonded anchors in ultra-high performance fibre reinforced concrete with a compressive strength higher than 130 MPa. The aim was to analyse the failure mechanisms in static pullout tests and to suggest a simple numerical model, which can be employed in a design stage, to reproduce the global behaviour of the anchor. The experimental observations show that a combined pullout and concrete cone failure occurred for an embedment depth of 40 mm and a steel rod failure for an embedment depth of 100 mm. The numerical model was set up using Abaqus software, by adopting the concrete damage plastic model and a surface-based cohesive behaviour for the interface concrete-anchor. The obtained failure modes and ultimate loads are in good agreement with experimental results. A minimum embedment depth of 50 mm was assessed to prevent a pullout failure of the anchor.


2017 ◽  
Vol 7 (2) ◽  
pp. 1523-1527 ◽  
Author(s):  
M. Touahmia

This paper investigates and discusses the composite behavior of geosynthetic reinforced soil mass. It presents the results of a series of large-scale laboratory tests supported by analytical methods to examine the performance of geogrid reinforcement subjected to static and cyclic pullout loading. The testing equipment and procedures used for this investigation are outlined. The results show that geosynthetic reinforcement can mobilize great resistance to static pulling load under high confining pressures. The reinforcement exhibits gradual deformation under cyclic loading showing no sign of imminent pullout failure for all levels of applied loads. In general, the results demonstrate that geosynthetic can be used in situations where loads are non-static, although care will be required in ensuring that appropriate factors of safety are applied to control the resulting deformation. A simplified analytical model for calculating the pulling capacity of geosynthetic reinforcement is proposed.


2017 ◽  
Vol 2017 ◽  
pp. 1-11 ◽  
Author(s):  
Yanqing Wang ◽  
Beicheng Wu ◽  
Yu Guo ◽  
Haifeng Yang

The fiber pullout is a main failure after the fiber is broken in the tension of glass fiber reinforced polymer (GFRP) bolt. In this paper, the numerical analysis is done on the distribution of both fiber normal force and interface shear stress. The results show that, on the ideal interface, the fiber pullout occurs from the lower end to the upper end of the matrix gradually, and both the normal stress of the fiber and the shear stress of the ideal interface gradually increase from the lower end to the upper end. With the increase of the interface layer thickness, the shear stress concentration area on the interface is enlarged while the stress applied is reduced, and the displacement of GFRP deformation is increasing sharply. This means that the capacity of GFRP deformation is enhanced. As a soft elastic body, the interface layer with a smaller elastic modulus can make the fiber stress and the interface shear stress sharply small and well dispersed. In addition, the load can be effectively transferred to the reinforced phase fibers in a bigger interfacial layer elastic modulus with a certain strength.