A novel methodology for imaging new bone formation around bioceramic bone substitutes

2007 ◽  
Vol 81A (2) ◽  
pp. 443-445 ◽  
Author(s):  
Alejandro A. Gorustovich ◽  
Matías G. Sivak ◽  
María B. Guglielmotti
Biomedicines ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 952
Author(s):  
Fabien Bornert ◽  
François Clauss ◽  
Guoqiang Hua ◽  
Ysia Idoux-Gillet ◽  
Laetitia Keller ◽  
...  

One major limitation for the vascularization of bone substitutes used for filling is the presence of mineral blocks. The newly-formed blood vessels are stopped or have to circumvent the mineral blocks, resulting in inefficient delivery of oxygen and nutrients to the implant. This leads to necrosis within the implant and to poor engraftment of the bone substitute. The aim of the present study is to provide a bone substitute currently used in the clinic with suitably guided vascularization properties. This therapeutic hybrid bone filling, containing a mineral and a polymeric component, is fortified with pro-angiogenic smart nano-therapeutics that allow the release of angiogenic molecules. Our data showed that the improved vasculature within the implant promoted new bone formation and that the newly-formed bone swapped the mineral blocks of the bone substitutes much more efficiently than in non-functionalized bone substitutes. Therefore, we demonstrated that our therapeutic bone substitute is an advanced therapeutical medicinal product, with great potential to recuperate and guide vascularization that is stopped by mineral blocks, and can improve the regeneration of critical-sized bone defects. We have also elucidated the mechanism to understand how the newly-formed vessels can no longer encounter mineral blocks and pursue their course of vasculature, giving our advanced therapeutical bone filling great potential to be used in many applications, by combining filling and nano-regenerative medicine that currently fall short because of problems related to the lack of oxygen and nutrients.


Materials ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 1993 ◽  
Author(s):  
Kunio Ishikawa ◽  
Youji Miyamoto ◽  
Akira Tsuchiya ◽  
Koichiro Hayashi ◽  
Kanji Tsuru ◽  
...  

Three commercially available artificial bone substitutes with different compositions, hydroxyapatite (HAp; Neobone®), carbonate apatite (CO3Ap; Cytrans®), and β-tricalcium phosphate (β-TCP; Cerasorb®), were compared with respect to their physical properties and tissue response to bone, using hybrid dogs. Both Neobone® (HAp) and Cerasorb® (β-TCP) were porous, whereas Cytrans® (CO3Ap) was dense. Crystallite size and specific surface area (SSA) of Neobone® (HAp), Cytrans® (CO3Ap), and Cerasorb® (β-TCP) were 75.4 ± 0.9 nm, 30.8 ± 0.8 nm, and 78.5 ± 7.5 nm, and 0.06 m2/g, 18.2 m2/g, and 1.0 m2/g, respectively. These values are consistent with the fact that both Neobone® (HAp) and Cerasorb® (β-TCP) are sintered ceramics, whereas Cytrans® (CO3Ap) is fabricated in aqueous solution. Dissolution in pH 5.3 solution mimicking Howship’s lacunae was fastest in CO3Ap (Cytrans®), whereas dissolution in pH 7.3 physiological solution was fastest in β-TCP (Cerasorb®). These results indicated that CO3Ap is stable under physiological conditions and is resorbed at Howship’s lacunae. Histological evaluation using hybrid dog mandible bone defect model revealed that new bone was formed from existing bone to the center of the bone defect when reconstructed with CO3Ap (Cytrans®) at week 4. The amount of bone increased at week 12, and resorption of the CO3Ap (Cytrans®) was confirmed. β-TCP (Cerasorb®) showed limited bone formation at week 4. However, a larger amount of bone was observed at week 12. Among these three bone substitutes, CO3Ap (Cytrans®) demonstrated the highest level of new bone formation. These results indicate the possibility that bone substitutes with compositions similar to that of bone may have properties similar to those of bone.


2020 ◽  
Vol 8 (1) ◽  
pp. 7 ◽  
Author(s):  
Savvas Titsinides ◽  
Theodore Karatzas ◽  
Despoina Perrea ◽  
Efstathios Eleftheriadis ◽  
Leonidas Podaropoulos ◽  
...  

Regeneration of large jaw bone defects still remains a clinical challenge. To avoid incomplete bone repair, bone grafts have been advocated to support the healing process. This study comparatively evaluated new bone formation among a synthetic graft substitute, a human bone derivative, and a bovine xenograft. Materials were placed in 3 out of the 4 bone cavities, while 1 deficit was left empty, serving as a control, in mono-cortical defects, surgically prepared in the porcine calvaria bone. Animals were randomized in 2 groups and euthanized at 8 and 12 weeks. Harvested tissue specimens were qualitatively evaluated by histology. New bone formation was quantitatively measured by histomorphometry. Maximum new bone formation was noticed in defects grafted with beta-tricalcium phosphate b-TCP compared to the other bone substitutes, at 8 and 12 weeks post-surgery. Bovine and human allograft induced less new bone formation compared to empty bone cavity. Histologic analysis revealed that b-TCP was absorbed and substituted significantly, while bovine and human allograft was maintained almost intact in close proximity with new bone. Based on our findings, higher new bone formation was detected in defects filled with b-TCP when compared to bovine and human graft substitutes.


2011 ◽  
Vol 493-494 ◽  
pp. 732-738 ◽  
Author(s):  
Cornelia Ganz ◽  
W. Xu ◽  
G. Holzhüter ◽  
W. Götz ◽  
B. Vollmar ◽  
...  

Various bone graft substitutes were used in clinical practise in the treatment of bone defects after trauma or osteoporosis. Many synthetic biomaterials were developed in recent years primarily based on hydroxyapatite (HA). NanoBone® is a nanocrystalline hydroxyapatite (HA) embedded in a porous matrix of silica (SiO2). The ratio of HA:SiO2 varied between 76:24 (wt%; NanoBone®) and 61:39 (wt%; Nanobone® S). The two bone substitutes NB and NB S and a natural bovine bone substitute Bio-Oss® (BO) were evaluated by means of implantation in the tibia of the rat. The aim of this study was to analyze the remodelling process and to measure new bone formation and degradation after implantation of these biomaterials. A tibia defect model was used for all investigations with testing periods of 12, 21 and 84 days. (n=5 for each time point). The results showed, that all bone grafts were well accepted by the host tissue without inflammatory reactions. In comparison to the biomaterial BO, NanoBone® and NanoBone® S were quickly degraded, whereas autologous proteins were incorporated into nanopores. New bone formation was statistically higher in NanoBone® S compared to Bio-Oss® in defect area after 84 days implantation. The presence of osteoclasts in tissue sections were demonstrated by TRAP- and ED1-immunohistology.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 238
Author(s):  
Anton Friedmann ◽  
Stefan Fickl ◽  
Kai R. Fischer ◽  
Milad Dalloul ◽  
Werner Goetz ◽  
...  

Various biomaterial combinations have been studied focusing on their ability to stabilize blood clots and maintain space under soft tissue to support new bone formation. A popular combination is Deproteinized Bovine Bone Mineral (DBBM) placed with a native collagen membrane (NCM) tacked to native bone. In this study, we compared the outcome of this treatment option to those achieved with three different graft/membrane combinations with respect to total newly occupied area and the mineralized compound inside. After bi-lateral extraction of two mandibular premolars in five adult beagles L-shaped alveolar defects were created. A total of 20 defects healed for 6 weeks resulting in chronic type bone defects. At baseline, four options were randomly allocated to five defects each: a. DBBM + NCM with a four-pin fixation across the ridge; b. DBBM + RCLC (ribose cross-linked collagen membrane); c. DBBM + NPPM (native porcine pericardium membrane); and d. Ca-sulfate (CS) + RCLC membrane. Membranes in b/c/d were not fixed; complete tensionless wound closure was achieved by CAF. Termination after 3 months and sampling followed, and non-decalcified processing and toluidine blue staining were applied. Microscopic images obtained at standardized magnification were histomorphometrically assessed by ImageJ software (NIH). An ANOVA post hoc test was applied; histomorphometric data are presented in this paper as medians and interquartile ranges (IRs). All sites healed uneventfully, all sites were sampled and block separation followed before Technovit embedding. Two central sections per block for each group were included. Two of five specimen were lost due to processing error and were excluded from group b. New bone area was significantly greater for option b. compared to a. (p = 0.001), c. (p = 0.002), and d. (p = 0.046). Residual non-bone graft area was significantly less for option d. compared to a. (p = 0.026) or c. (p = 0.021). We conclude that collagen membranes with a prolonged resorption/barrier profile combined with bone substitutes featuring different degradation profiles sufficiently support new bone formation. Tacking strategy/membrane fixation appears redundant when using these biomaterials.


Author(s):  
T. Hidaka ◽  
H. Shimizu ◽  
T. Watanabe ◽  
I. Nakao ◽  
K. Seto

Author(s):  
Jooseong Kim ◽  
Sukyoung Kim ◽  
In-Hwan Song

Octacalcium phosphate (OCP) is a precursor of biological apatite crystals that has attracted attention as a possible bone substitute. On the other hand, few studies have examined this material at the experimental level due to the limitations of OCP mass production. Recently, mass production technology of OCP was developed, and the launch of OCP bone substitutes is occurring. In this study, the bone regeneration capacity of OCP products was compared with two of the most clinically used materials: heat-treated bovine bone (BHA) and sintered biphasic calcium phosphate (BCP). Twelve rabbits were used, and defects in each tibia were filled with OCP, BHA, BCP, and left unfilled as control (CON). The tibias were harvested at 4 and 12 weeks, and 15 μm slides were prepared using the diamond grinding method after being embedded in resin. Histological and histomorphometric analyses were performed to evaluate the bone regeneration ability and mechanism. The OCP showed significantly higher resorption and new bone formation in both periods analysed (p<0.05). Overall, OCP bone substitutes can enhance bone regeneration significantly by activating osteoblasts and a rapid phase transition of OCP crystals to biological apatite crystals (mineralisation), as well as providing additional space for new bone formation by rapid resorption.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Stephan Christian Möhlhenrich ◽  
Kristian Kniha ◽  
Zuzanna Magnuska ◽  
Benita Hermanns-Sachweh ◽  
Felix Gremse ◽  
...  

AbstractTo minimize the postoperative risks posed by grafting autologous transplants for cleft repair, efforts are being made to improve grafting materials for use as potential alternatives. The aim of this study was to compare the bone graft quality of different bone substitutes including the gold standard autografts during the healing processes after cleft repair in the context of orthodontic treatment. In 21 Wistar rats, a complete, continuity-interrupting cleft was created. After 4 weeks, cleft repair was performed using autografts from the hips’ ischial tuberosity, human xenografts, or synthetic bone substitutes [beta-tricalcium phosphate (β-TCP)/hydroxyapatite (HA)]. After another 4 weeks, the first molar movement was initiated in the reconstructed jaw for 8 weeks. The bone remodeling was analyzed in vivo using micro-computed tomography (bone mineral density and bone volume fraction) and histology (new bone formation). All the grafting materials were statistically different in bone morphology, which changed during the treatment period. The β-TCP/HA substitute demonstrated less resorption compared to the autologous and xenogeneic/human bone, and the autografts led to a stronger reaction in the surrounding bone. Histologically, the highest level of new bone formation was found in the human xenografts, and the lowest was found in the β-TCP/HA substitute. The differences between the two bone groups and the synthetic materials were statistically significant. Autografts were confirmed to be the gold standard in cleft repair with regard to graft integration. However, parts of the human xenograft seemed comparable to the autografts. Thus, this substitute could perhaps be used as an alternative after additional tissue-engineered modification.


2006 ◽  
Vol 309-311 ◽  
pp. 255-258
Author(s):  
Y.S. Kim ◽  
Tae Gyun Kim ◽  
Ui Won Jung ◽  
C.S. Kim ◽  
Seong Ho Choi ◽  
...  

Dehiscence bone defects, frequently observed on dental implants placed in periodontitis-affected alveolar bone or extraction sockets were treated with β-tricalcium phosphate (β –TCP) and chitosan membrane for guided bone regeneration, and the new bone formation on the treated sites were studied. Beagle dogs were used for the experiment. First to fourth mandibular premolars were extracted, and the post extraction alveolar bone surface was planed. After 8 weeks of healing, 3 by 4mm dehiscence defects were created using straight fissure burs. Total of 16 oxidized titanium surface implants were placed on the bone defects of the subjects, two on each side. Control sites were treated with implants only. Experimental Group 1 sites were treated with implants and chitosan membrane. Experimental Group 2 sites were treated with implants, β-TCP and chitosan membrane. Experimental Group 3 sites were treated with implants, β-TCP, autogenous bone and chitosan membrane. The animals were sacrificed 12 weeks after implant placement, and the specimens from the treated sites were histologically studied with following results. Limited amount of new bone formation was observed in control group with unexposed membrane. Slightly greater amount of bone formation was observed on sites treated with β-TCP+membrane or autogenous bone+ β-TCP+membrane compared to control group. Remnants of chitosan membrane and β-TCP encapsulated with connective tissue were observed during experimental periods. These results suggest that further studies are needed on membrane rigidity and infection control for space maintenance underneath the membrane and bone substitutes in the treatment of dehiscence defects.


Sign in / Sign up

Export Citation Format

Share Document