Simulation of 2D Interference Pattern Structure for Rectangular and Circular Slits Using Dual Beam Interference Technique

2021 ◽  
Vol 397 (1) ◽  
pp. 2100001
Author(s):  
Girijesh Narayan Pandey ◽  
Anil Kumar Shukla ◽  
Khem B. Thapa ◽  
Munendra Singh ◽  
Ram Chandra Singh
Author(s):  
M.A. Gribelyuk ◽  
J.M. Cowley

Recently the use of a biprism in a STEM instrument has been suggested for recording of a hologram. A biprism is inserted in the illumination system and creates two coherent focussed beams at the specimen level with a probe size d= 5-10Å. If one beam passes through an object and another one passes in vacuum, an interference pattern, i.e. a hologram can be observed in diffraction plane (Fig.1).


2006 ◽  
Vol 43 (9) ◽  
pp. 470-482 ◽  
Author(s):  
Nicolas Jeanvoine ◽  
Christian Holzapfel ◽  
Flavio Soldera ◽  
Frank Mücklich
Keyword(s):  

Author(s):  
Jie Zhu ◽  
Soo Sien Seah ◽  
Irene Tee ◽  
Bing Hai Liu ◽  
Eddie Er ◽  
...  

Abstract In this paper, we describe automated FIB for TEM sample preparation using iFast software on a Helios 450HP dual-beam system. A robust iFast automation recipe needs to consider as many variables as possible in order to ensure consistent sample quality and high success rate. Variations mainly come from samples of different materials, structures, surface patterns, surface topography and surface charging. The recipe also needs to be user-friendly and provide high flexibility by allowing users to choose preferable working parameters for specific types of samples, such as: grounding, protective layer coating, milling steps, and final TEM lamella thickness/width. In addition to the iFast recipe, other practical factors affecting automation success rate are also discussed and highlighted.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Wen-Fei Hsieh ◽  
Shih-Hsiang Tseng ◽  
Bo Min She

Abstract In this study, an FIB-based cross section TEM sample preparation procedure for targeted via with barrier/Cu seed layer is introduced. The dual beam FIB with electron beam for target location and Ga ion beam for sample milling is the main tool for the targeted via with barrier/Cu seed layer inspection. With the help of the FIB operation and epoxy layer protection, ta cross section TEM sample at a targeted via with barrier/Cu seed layer could be made. Subsequent TEM inspection is used to verify the quality of the structure. This approach was used in the Cu process integration performance monitor. All these TEM results are very helpful in process development and yield improvement.


Author(s):  
Steven B. Herschbein ◽  
Hyoung H. Kang ◽  
Scott L. Jansen ◽  
Andrew S. Dalton

Abstract Test engineers and failure analyst familiar with random access memory arrays have probably encountered the frustration of dealing with address descrambling. The resulting nonsequential internal bit cell counting scheme often means that the location of the failing cell under investigation is nowhere near where it is expected to be. A logical to physical algorithm for decoding the standard library block might have been provided with the design, but is it still correct now that the array has been halved and inverted to fit the available space in a new processor chip? Off-line labs have traditionally been tasked with array layout verification. In the past, hard and soft failures could be induced on the frontside of finished product, then bitmapped to see if the sites were in agreement. As density tightened, flip-chip FIB techniques to induce a pattern of hard fails on packaged devices came into practice. While the backside FIB edit method is effective, it is complex and expensive. The installation of an in-line Dual Beam FIB created new opportunities to move FA tasks out of the lab and into the FAB. Using a new edit procedure, selected wafers have an extensive pattern of defects 'written' directly into the memory array at an early process level. Bitmapping of the RAM blocks upon wafer completion is then used to verify correlation between the physical damaged cells and the logical sites called out in the test results. This early feedback in-line methodology has worked so well that it has almost entirely displaced the complex laboratory procedure of backside FIB memory array descramble verification.


Author(s):  
C.H. Wang ◽  
S.P. Chang ◽  
C.F. Chang ◽  
J.Y. Chiou

Abstract Focused ion beam (FIB) is a popular tool for physical failure analysis (FA), especially for circuit repair. FIB is especially useful on advanced technology where the FIB is used to modify the circuit for new layout verification or electrical measurement. The samples are prepared till inter-metal dielectric (IMD), then a hole is dug or a metal is deposited or oxide is deposited by FIB. A common assumption is made that metal under oxide can not be seen by FIB. But a metal ion image is desired for further action. Dual beam, FIB and Scanning Electron Microscope (SEM), tools have a special advantage. When switching back and forth from SEM to FIB the observation has been made that the metal lines can be imaged. The details of this technique will be discussed below.


Author(s):  
Gunnar Zimmermann ◽  
Richard Chapman

Abstract Dual beam FIBSEM systems invite the use of innovative techniques to localize IC fails both electrically and physically. For electrical localization, we present a quick and reliable in-situ FIBSEM technique to deposit probe pads with very low parasitic leakage (Ipara < 4E-11A at 3V). The probe pads were Pt, deposited with ion beam assistance, on top of highly insulating SiOx, deposited with electron beam assistance. The buried plate (n-Band), p-well, wordline and bitline of a failing and a good 0.2 μm technology DRAM single cell were contacted. Both cells shared the same wordline for direct comparison of cell characteristics. Through this technique we electrically isolated the fail to a single cell by detecting leakage between the polysilicon wordline gate and the cell diffusion. For physical localization, we present a completely in-situ FIBSEM technique that combines ion milling, XeF2 staining and SEM imaging. With this technique, the electrically isolated fail was found to be a hole in the gate oxide at the bad cell.


2014 ◽  
Vol 27 (7) ◽  
pp. 663-668
Author(s):  
Chao Zhu ◽  
Changhua Lu ◽  
Wenqing Liu ◽  
Yujun Zhang ◽  
Xiaoting Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document