Computer analysis of side-band holography in STEM

Author(s):  
M.A. Gribelyuk ◽  
J.M. Cowley

Recently the use of a biprism in a STEM instrument has been suggested for recording of a hologram. A biprism is inserted in the illumination system and creates two coherent focussed beams at the specimen level with a probe size d= 5-10Å. If one beam passes through an object and another one passes in vacuum, an interference pattern, i.e. a hologram can be observed in diffraction plane (Fig.1).

Author(s):  
M. Rühle ◽  
J. Mayer ◽  
J.C.H. Spence ◽  
J. Bihr ◽  
W. Probst ◽  
...  

A new Zeiss TEM with an imaging Omega filter is a fully digitized, side-entry, 120 kV TEM/STEM instrument for materials science. The machine possesses an Omega magnetic imaging energy filter (see Fig. 1) placed between the third and fourth projector lens. Lanio designed the filter and a prototype was built at the Fritz-Haber-Institut in Berlin, Germany. The imaging magnetic filter allows energy-filtered images or diffraction patterns to be recorded without scanning using efficient area detection. The energy dispersion at the exit slit (Fig. 1) results in ∼ 1.5 μm/eV which allows imaging with energy windows of ≤ 10 eV. The smallest probe size of the microscope is 1.6 nm and the Koehler illumination system is used for the first time in a TEM. Serial recording of EELS spectra with a resolution < 1 eV is possible. The digital control allows X,Y,Z coordinates and tilt settings to be stored and later recalled.


1992 ◽  
Vol 45 (1) ◽  
pp. 103-113 ◽  
Author(s):  
M.G. Gribelyuk ◽  
J.M. Cowley
Keyword(s):  

Author(s):  
E. L. Hall

Sensitization in stainless steels is caused by the formation of chromium-rich M23C6 carbides at grain boundaries, which depletes the adjacent matrix and boundary region of chromium, and hence leads to rapid intergranular attack. To fully understand the sensitization process, and to test the accuracy of theories proposed to model this process, it is necessary to obtain very accurate measurements of the chromium concentration at grain boundaries in sensitized specimens. Quantitative X-ray spectroscopy in the analytical electron microscope (AEM) enables the chromium concentration profile across these boundaries to be studied directly; however, it has been shown that a strong effect of foil thickness and electron probe size may be present in the analysis of rapidly-changing compositional gradients. The goal of this work is to examine these effects.


Author(s):  
E. A. Kenik ◽  
J. Bentley

Cliff and Lorimer (1) have proposed a simple approach to thin foil x-ray analy sis based on the ratio of x-ray peak intensities. However, there are several experimental pitfalls which must be recognized in obtaining the desired x-ray intensities. Undesirable x-ray induced fluorescence of the specimen can result from various mechanisms and leads to x-ray intensities not characteristic of electron excitation and further results in incorrect intensity ratios.In measuring the x-ray intensity ratio for NiAl as a function of foil thickness, Zaluzec and Fraser (2) found the ratio was not constant for thicknesses where absorption could be neglected. They demonstrated that this effect originated from x-ray induced fluorescence by blocking the beam with lead foil. The primary x-rays arise in the illumination system and result in varying intensity ratios and a finite x-ray spectrum even when the specimen is not intercepting the electron beam, an ‘in-hole’ spectrum. We have developed a second technique for detecting x-ray induced fluorescence based on the magnitude of the ‘in-hole’ spectrum with different filament emission currents and condenser apertures.


Author(s):  
John W. Coleman

The injector to be described is a component in the Electron Injector-Linear Accelerator—Condenser Module for illumination used on the variable 100-500kV electron microscope being built at the Radio Corporation of America for the University of Virginia.The injector is an independently powered, autonomous unit, operating at a constant 6kV positive with respect to accelerator potential, thereby making beam current independent of accelerator potential. The injector provides for on-axis ion trapping to prolong filament lifetime, and incorporates a derived Einzel lens for optical integration into the overall illumination system for microscopy. Electrostatic beam deflectors for alignment are an integral part of the apparatus. The entire injector unit is cantilevered off a door for side loading, and is topped with a 4-filament turret released electrically but driven by a self-contained Negator spring motor.


Author(s):  
M. Osumi ◽  
N. Yamada ◽  
T. Nagatani

Even though many early workers had suggested the use of lower voltages to increase topographic contrast and to reduce specimen charging and beam damage, we did not usually operate in the conventional scanning electron microscope at low voltage because of the poor resolution, especially of bioligical specimens. However, the development of the “in-lens” field emission scanning electron microscope (FESEM) has led to marked inprovement in resolution, especially in the range of 1-5 kV, within the past year. The probe size has been cumulated to be 0.7nm in diameter at 30kV and about 3nm at 1kV. We have been trying to develop techniques to use this in-lens FESEM at low voltage (LVSEM) for direct observation of totally uncoated biological specimens and have developed the LVSEM method for the biological field.


Author(s):  
Klaus-Ruediger Peters

A new generation of high performance field emission scanning electron microscopes (FSEM) is now commercially available (JEOL 890, Hitachi S 900, ISI OS 130-F) characterized by an "in lens" position of the specimen where probe diameters are reduced and signal collection improved. Additionally, low voltage operation is extended to 1 kV. Compared to the first generation of FSEM (JE0L JSM 30, Hitachi S 800), which utilized a specimen position below the final lens, specimen size had to be reduced but useful magnification could be impressively increased in both low (1-4 kV) and high (5-40 kV) voltage operation, i.e. from 50,000 to 200,000 and 250,000 to 1,000,000 x respectively.At high accelerating voltage and magnification, contrasts on biological specimens are well characterized1 and are produced by the entering probe electrons in the outmost surface layer within -vl nm depth. Backscattered electrons produce only a background signal. Under these conditions (FIG. 1) image quality is similar to conventional TEM (FIG. 2) and only limited at magnifications >1,000,000 x by probe size (0.5 nm) or non-localization effects (%0.5 nm).


Author(s):  
M. Iwatsuki ◽  
Y. Kokubo ◽  
Y. Harada

On accout of its high brightness, small optical source size, and minimal energy spread, the field emission gun (FEG) has the advantage that it provides the conventional transmission electron microscope (TEM) with a highly coherent illumination system and directly improves the resolving power and signal-to-noise ratio of the scanning electron microscope (SEM). The FEG is generally classified into two types; the cold field emission (C-FEG) and thermal field emission gun (T-FEG). The former, in which a field emitter is used at the room temperature, was successfully developed as an electron source for the SEM. The latter, in which the emitter is heated to the temperature range of 1000-1800°K, was also proved to be very suited as an electron source for the TEM, as well as for the SEM. Some characteristics of the two types of the FEG have been studied and reported by many authors. However, the results of the respective types have been obtained separately under different experimental conditions.


Author(s):  
J. R. Michael

X-ray microanalysis in the analytical electron microscope (AEM) refers to a technique by which chemical composition can be determined on spatial scales of less than 10 nm. There are many factors that influence the quality of x-ray microanalysis. The minimum probe size with sufficient current for microanalysis that can be generated determines the ultimate spatial resolution of each individual microanalysis. However, it is also necessary to collect efficiently the x-rays generated. Modern high brightness field emission gun equipped AEMs can now generate probes that are less than 1 nm in diameter with high probe currents. Improving the x-ray collection solid angle of the solid state energy dispersive spectrometer (EDS) results in more efficient collection of x-ray generated by the interaction of the electron probe with the specimen, thus reducing the minimum detectability limit. The combination of decreased interaction volume due to smaller electron probe size and the increased collection efficiency due to larger solid angle of x-ray collection should enhance our ability to study interfacial segregation.