Design of a low-pass filter for an automatic measuring instrument (spectropyrometer)

1966 ◽  
Vol 9 (2) ◽  
pp. 197-199
Author(s):  
V. E. Finkel'shtein ◽  
A. N. Kisel'
2021 ◽  
Vol 5 (2) ◽  
pp. 100-109
Author(s):  
Kemahyanto Exaudi ◽  
Rendyansyah Rendyansyah ◽  
Aditya Putra Perdana Prasetyo

Biomedical technology has now been widely adopted as a means of monitoring the human body in real-time. For example, to detect eye movement. In the medical world, eye movement can be used to determine the type of disease. With the application of human-machine interface (HMI) technology, eyeball movement can be developed in the robotics industry as robot navigation. For example, by moving the eyeball left and right, the robot can interpret the eye signal to move left and right. The interaction between the eyeball movement and the robot is of particular concern in this study. This study aimed to design a measuring instrument for eye movement detection using Electrooculography (EOG) techniques to move a wheeled robot. The EOG measuring instrument consisting of an instrument differential amplifier, a low pass filter, and a high pass filter has been applied in this research. The signal generator technique on EOG is carried out by placing electrodes on three sides of the face, namely forehead (G), left horizontal (H-), right horizontal (H +). The experimental results showed a significant difference between the left and right eye movement amplitude signals. This amplitude is used to classify the movement of the robot wheel towards the left and right. The process of sending robot signals and EOG measuring instruments uses Bluetooth HC-05 serial communication. Based on the research results, it is proven that the robot manages to move left and right according to the eyeball movement.


2017 ◽  
Vol E100.C (10) ◽  
pp. 858-865 ◽  
Author(s):  
Yohei MORISHITA ◽  
Koichi MIZUNO ◽  
Junji SATO ◽  
Koji TAKINAMI ◽  
Kazuaki TAKAHASHI

2016 ◽  
Vol 15 (12) ◽  
pp. 2579-2586
Author(s):  
Adina Racasan ◽  
Calin Munteanu ◽  
Vasile Topa ◽  
Claudia Pacurar ◽  
Claudia Hebedean

Author(s):  
Nanan Chomnak ◽  
Siradanai Srisamranrungrueang ◽  
Natapong Wongprommoon
Keyword(s):  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4305
Author(s):  
Takamasa Terada ◽  
Masahiro Toyoura ◽  
Takahide Sato ◽  
Xiaoyang Mao

In this work, we propose a fabric electrode with a special structure that can play the role of a noise reduction filter. Fabric electrodes made of the conductive fabric have been used for long-term ECG measurements because of their flexibility and non-invasiveness; however, due to the large impedance between the skin and the fabric electrodes, noise is easily introduced into the ECG signal. In contrast to conventional work, in which chip-type passive elements are glued to the electrode to reduce noise, the proposed electrode can obtain a noise-reduced ECG by changing the structure of fabric. Specifically, the proposed electrode was folded multiple times to form a capacitor with a capacitance of about 3 nF. It is combined with the skin-electrode impedance to form a low-pass filter. In the experiment, we made a prototype of the electrodes and measured ECG at rest and during EMG-induced exercise. As a result, the SNR values at rest and during exercise were improved about 12.02 and 10.29 , respectively, compared with the fabric electrode without special structure. In conclusion, we have shown that changing the fabric electrode structure effectively removes noise in ECG measurement.


Sign in / Sign up

Export Citation Format

Share Document