scholarly journals Quantitative evaluation of the progressive wear of powered interproximal reduction systems after repeated use

Author(s):  
C. Livas ◽  
T. Baumann ◽  
S. Flury ◽  
N. Pandis

Abstract Purpose To evaluate the residual surface roughness of 5 common diamond-coated interproximal reduction (IPR) systems after consecutive in vitro applications in relation to system, diamond grain size, and instrument thickness. Methods IPR was performed on 80 extracted human incisors using motor-driven strips and discs under predefined conditions. The IPR auxiliaries were applied at 5 consecutive sessions of 20 s on intact interproximal surfaces, and the surface profile (Ra, Rz, Rmax) was analyzed at baseline and after each session with an optical profilometer. Results No overall significant difference in the roughness values was found between systems (P = 0.07 for Ra, P = 0.33 for Rz, and P = 0.48 for Rmax). There was a significant average decrease of Ra, Rz, and Rmax for all systems for every unit increase in time by −0.171 μm (P < 0.001), −3.297 (P ≤ 0.001), and −2.788 μm (P = 0.001), respectively. Ra, Rz, and Rmax values increased significantly, i.e., by 0.194 μm (P = 0.003), 5.890 μm (P = 0.001), and 5.319 μm (P = 0.010) as instrument thickness increased by one unit. No significant reductions in Ra, Rz, and Rmax were observed across grain sizes (−0.008 μm [P > 0.05], −0.244 μm [P > 0.05], and −0.179 μm [P > 0.05], respectively). There was no evidence of interaction between system and time as the P values for Ra, Rz, and Rmax were 0.88, 0.51, and 0.70, respectively. Conclusions All IPR materials presented significant gradual decrease of surface roughness after repeated applications. There were no significant roughness changes among auxiliaries of different grain sizes. Thinner auxiliaries showed significantly more roughness reduction, possibly requiring more frequent replacement than thick auxiliaries in clinical practice.

2021 ◽  
Vol 15 (1) ◽  
pp. 25-32
Author(s):  
Abdullah Aljamhan ◽  
Syed Rashid Habib ◽  
Mohammed A. AlSarhan ◽  
Bashayer AlZahrani ◽  
Hessa AlOtaibi ◽  
...  

Objective: The aim of this in vitro study was to compare the effect of three finishing/polishing systems on the surface roughness (Ra) of conventional and Bulk-fill composite resins. Materials and methods: The Ra values of three different brands of Bulk-fill composites (Filtek Bulk-fill®, 3M ESPE; SonicFill Bulk-fill®, Kerr; SDR Bulk-fill®, Dentsply) were tested and compared with the Ra of a conventional composite (Filtek XT Z350®, 3M ESPE). A total of 30 discs (10 mm × 2 mm) were fabricated from four test materials and divided into three groups (n = 10/group) depending on the three finishing/polishing systems used (Astropol®, Ivoclar Vivadent; PoGo®, Dentsply; Sof-LexTM®, 3M ESPE). The Ra of each specimen was recorded with an optical profilometer (Contour-GT-X®, USA). ANOVA and Tukey’s tests were used for statistical analysis. Results: Statistically significant differences (P < 0.05) were observed between the Ra values of all composite materials tested with three finishing/polishing systems. Among composite materials, only Group-III showed a significant difference (P = 0.003) in Ra obtained using all three finishing/polishing systems. SDR Bulk-fill® and Filtek XT Z350® showed the highest (0.810 ± 0.373 µm) and lowest (0.365 ± 0.119 µm) Ra values, respectively. Individually, the highest Ra was recorded for SDR Bulk-fill® when it was finished/polished with the Astropol® system. SonicFill Bulk-fill® and SDR Bulk-fill® composites exhibited the lowest Ra values when they were finished with the PoGo® system. Conclusion: Finishing and polishing techniques greatly affect the surface roughness of different Bulk-fill composites because variations in the surface roughness were observed for all tested composite materials. Filtek XT Z350® exhibited the lowest surface roughness, while SDR Bulk-fill® exhibited the highest surface roughness among the tested composite materials.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Reem Abualsaud ◽  
Doaa M. Aleraky ◽  
Sultan Akhtar ◽  
Soban Q. Khan ◽  
Mohammed M. Gad

Objective. To evaluate the antimicrobial effects of different concentrations of zirconium dioxide nanoparticles (nano-ZrO2) reinforcement of poly(methyl) methacrylate (PMMA) on surface roughness and C. albicans biofilm. Methods. 20 heat-polymerized acrylic resin discs were conventionally made and divided into 4 groups (n = 5) according to nano-ZrO2 concentration: control (0% filler) and 3 experimental groups (2.5% (Z2.5), 5.0% (Z5.0), and 7.5% (Z7.5)). An optical profilometer was used for surface roughness evaluation, followed by Candida adherence assay. Specimens were sterilized, then immersed in cultured yeast (C. albicans), and incubated at 37°C for 48 hours. After that, discs were rinsed before extracting the clustered pellets of Candida. The attached C. albicans was counted using the direct method after spreading on agar media and incubating for 48 hours. Statistical analysis was performed using one-way ANOVA and Tukey’s post hoc test at α = 0.05. Results. Surface roughness was significantly increased with all modified groups compared with control ( P < 0.01 ), which showed the lowest roughness value (0.027 ± 0.004 μm). There was no significant difference in the roughness value among reinforced groups (2.5, 5.0, and 7.5%) ( P > 0.05 ), with Z7.5 showing the highest roughness value (0.042 ± 0.004 μm). Candida count was reduced as the nano-ZrO2 increased but not significantly ( P = 0.15 ). Conclusions. The addition of different concentrations of nano-ZrO2 particles to PMMA increased the surface roughness compared with control; in contrast, insignificant reduction of C. albicans biofilm was detected.


2020 ◽  
Vol 47 (3) ◽  
pp. 223-231 ◽  
Author(s):  
Fabienne Suter ◽  
Spiros Zinelis ◽  
Raphael Patcas ◽  
Marc Schätzle ◽  
George Eliades ◽  
...  

Objective: The characterisation of surface roughness and energy of contemporary thermoplastic materials used in manufacturing of orthodontic aligners. Design: In vitro, laboratory study. Materials and methods: Four commercially available thermoplastic materials were selected (CA-medium/CAM, Essix-copopyester/COP, Duran/DUR and Erkodur/ERK). Five disks from each, as received, material were tested and subjected to: (1) reflected light microscopy; (2) optical profilometry for the estimation of Sa, Sz, Sq, Sdr, Sc, Sv surface roughness parameters (n = 5); and (3) contact angle measurements with a Zisman series of liquids for the estimation of critical surface tension (γC), total work of adhesion (WA), as well as the work of adhesion due to polar (WP) and dispersion (WD) components employing the Zisman method (n = 5/liquid). Thermoformed disks were prepared against a dental stone model and the roughness parameters were calculated again Statistical analysis was performed by one-way ANOVA/ Tukey multiple comparison test and t-test (a = 0.05). Results: Microscopic and profilometric analyses revealed a smooth surface texture in the as-received materials, but a very rough texture after thermoforming, with insignificant differences within each state. Significant differences in the as-received state were found in the surface energy parameters; CAM showed the lowest γC and the highest WA, WP, WD, whereas ERK with the highest γC demonstrated lower WA. COP and DUR were ranked in an intermediate group regarding γC, with a statistically significant difference in WA between them, mainly attributed to the lower WP of the former. Conclusion: Given the differences in surface energy parameters and the lack of roughness differences within the as received or thermoformed groups, it may be concluded that variations in the plaque retaining capacity are anticipated, determined by γC, WA and the WP, WD components.


2018 ◽  
Vol 20 (4) ◽  
pp. 238
Author(s):  
Júlia Bazaga Ferreira ◽  
Gabriella Rodovalho Paiva ◽  
Vinícius Rangel Geraldo-Martins ◽  
Juliana Jendiroba Faraoni ◽  
Regina Guenka Palma Dibb ◽  
...  

O objetivo deste trabalho in vitro foi avaliar a influência de diferentes agentes remineralizantes no tratamento de lesões erosivas em esmalte. Foram confeccionados espécimes de 4mmx4mm e 3 mm de espessura a partir da superfície vestibular de incisivos bovinos (n=10) e divididos aleatoriamente em 4 grupos. G1=aplicação do dentifrício remineralizante, G2= aplicação do agente potencializador remineralizante, G3= dentifrício remineralizante + agente potencializador remineralizante, G4=aplicação de verniz fluoretado (controle positivo), G5=nenhum tratamento (controle negativo). Os espécimes foram imersos em refrigerante durante um período de 10 dias. A rugosidade superficial foi analisada por meio de microscopia confocal de varredura a laser. Os dados foram analisados quanto à homogeneidade (Levene’s) e normalidade (Kolmogorov- Smirnov). Foram realizados testes paramétricos com análise de variância a dois critérios: fator tempo e fator tratamento, e pós-teste de Tukey para diferenciação das médias. Todos os testes estatísticos tiveram nível de significância de 5% (α=0,05). Os resultados obtidos mostraram diferenças estatisticamente significantes, demonstrando a redução da rugosidade da superfície do esmalte logo após o primeiro tratamento (G3) e para os demais grupos (G1, G2 e G4) somente após o segundo tratamento. Concluiu-se que a utilização de dentifrício composto por silicato de cálcio e fosfato de sódio influenciou na rugosidade do esmalte erodido do dente bovino.Palavras-chave: Dentifrícios. Erosão Dentária. Esmalte Dentário.Abstract The objective of this in vitro study was to evaluate the influence of different remineralizing agents in the treatment of enamel erosive lesions. Specimens of 4mmx4mm and 3mm thickness were made from the buccal surface of bovine incisors (n=10) and randomly divided into 4 groups. G1 = application of the remineralizing dentifrice, G2 = application of the remineralizing agent, G3 = remineralizing dentifrice + remineralizing agente, G4 = application of fluoride varnish (positive control), G5 = no treatment Specimens were immersed in refrigerant solution during a period of 10 days. The surface roughness was analyzed by means of confocal laser scanning microscopy. The data were analyzed for homogeneity (Levene's) and normality (Kolmogorov-Smirnov). Parametric tests with analysis of variance were performed on two criteria: time factor and treatment factor, and Tukey post-test for differentiation of means. All tests were statistically significant at 5% (α = 0.05). The results showed statistically significant difference, demonstrating the reduction of surface roughness after the first treatment (G3) and the other groups (G1, G2 and G4) only after the second treatment. It was concluded that the use of dentifrice composed of calcium silicate and sodium phosphate influenced the roughness of the eroded tooth enamel of the bovine tooth.Keywords: Dentifrices. Tooth Erosion. Tooth Enamel.


2018 ◽  
Vol 21 (1) ◽  
pp. 96 ◽  
Author(s):  
Tabata Prado Sato ◽  
Celio Ilidio Conjo ◽  
Rodnei Dennis Rossoni ◽  
Juliana Campos Junqueira ◽  
Renata Marques de Melo ◽  
...  

<p><strong>Objective: </strong>This study evaluated the effects of the incorporation of silver nanoparticles (AgNPs) obtained from <em>Fusarium oxysporum</em> on heat-activated acrylic resin (HAAR) and their influence on resin’s surface roughness, hardness, color alteration and antimicrobial capacity against <em>Candida albicans</em>. <strong>Material and Methods:</strong> For this, 50 discs of HAAR (2x5 mm) were produced and divided into three groups, Control: HAAR; Ag1: HAAR plus 0.539 mg of AgNPs; and Ag2: HAAR plus 1.1 mg of AgNPs. Knopp hardness (HK), surface roughness (Ra and Rz) and color alteration according to the CIE Lab were measured. Specimens were then evaluated <em>in vitro</em> with regard to <em>C. albicans</em> biofilm formation through formed colony count (CFU/mL). Scanning Electron Microscopy (SEM) and Atomic force microscopy (AFM) analyses were performed. <strong>Results:<em> </em></strong>The addition of AgNPs of both concentrations changed Ra, Rz and HK significantly. There was statistically significant difference for L (p=0.00); a*(p=0.00) and b*(p=0.00) parameters. There were no differences between Ag1 and Ag2 biofilm formation, but the comparison of both with the control group presented a significant reduction (p=0.0091) on biofilm formation. SEM and AFM images showed no signs of NPs clustering. <strong>Conclusion:</strong> It can be concluded tha AgNPs incorporation in HAAR was effective in reducing <em>C. albicans</em> activity, with a slight change in color and hardness of the material, being effective therefore, in regions such as the dental prostheses palate, which have lesser aesthetic appeal.</p><p><strong>Keywords</strong></p><p>Acrylic resins; Silver; Antimicrobial agents.</p>


2019 ◽  
Vol 44 (3) ◽  
pp. E122-E132 ◽  
Author(s):  
L St-Pierre ◽  
C Martel ◽  
H Crépeau ◽  
MA Vargas

SUMMARY Objectives: The objective of this in vitro study was to compare, with a threshold value of 200 nm, the surface roughness obtained when using 12 different polishing systems on four different composite resins (microfill, nanofill, and two nanohybrids). Methods and Materials: A total of 384 convex specimens were made using Durafill VS, Filtek Supreme Ultra, Grandio SO, and Venus Pearl. After sandblasting and finishing with a medium-grit finishing disc, initial surface roughness was measured using a surface roughness tester. Specimens were polished using 12 different polishing systems: Astropol, HiLuster Plus, D♦Fine, Diacomp, ET Illustra, Sof-Lex Wheels, Sof-Lex XT discs, Super-Snap, Enhance/Pogo, Optrapol, OneGloss and ComposiPro Brush (n=8). The final surface roughness was measured, and data were analyzed using two-way analysis of variance. Pairwise comparisons were made using protected Fisher least significant difference. Results: There were statistical differences in the final surface roughness between polishing systems and between composite resins (p&lt;0.05). The highest surface roughness was observed for all composite resins polished with OneGloss and ComposiPro Brush. Enhance/Pogo and Sof-Lex Wheels produced a mean surface roughness greater than the 200-nm threshold on Filtek Supreme Ultra, Grandio SO, and Venus Pearl. Data showed that there was an interaction between the composite resins and the polishing systems. Conclusions: A single polishing system does not perform equally with all composite resins. Except for Optrapol, multi-step polishing systems performed generally better than one-step systems. Excluding Enhance/Pogo, diamond-impregnated polishers led to lower surface roughness. Durafill VS, a microfill composite resin, may be polished more predictably with different polishers.


Polymers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 3694
Author(s):  
Nawaf Labban ◽  
Mohammad D. Al Al Amri ◽  
Sarah M Alnafaiy ◽  
Saleh M. Alhijji ◽  
Mohammad A. Alenizy ◽  
...  

The aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM). One hundred and twenty specimens (12 × 14 × 2.5 mm) were prepared using a precision saw. For each material (n = 24), the specimens were allocated into two groups, polished and stained. The specimens of each group were stored (for 7 days) in either citric acid (0.2N) or distilled water. Data for surface gloss (ΔE*SCE-SCI) and roughness (Ra) were evaluated before (baseline) and after simulated toothbrushing. For toothbrushing simulation, a toothpaste slurry containing a toothpaste of 100 relative dentin abrasion (RDA) and 0.3 mL distilled water was used for 3650 cycles (7300 strokes) for each specimen. Data were analyzed using t-test and ANOVA. A p-value of ≤ to 0.05 was considered significant. The highest mean value of surface gloss was identified in CU (stained—water) (4.3 (0.47)) (ΔE*) and EN (stained—acid) (4.3 (1.00)) (ΔE*) specimens, whereas the lowest mean value was shown by SH (stained—acid) (2.04 (0.42)) (ΔE*) samples. The highest mean value of surface roughness was observed in SH (0.40 (0.99)) Ra (stained—acid) whereas the lowest in VM (0.13 (0.039)) Ra (polished—water). A significant difference (p < 0.05) was observed in surface roughness and gloss between the materials with simulated toothbrushing, except in VM and LU, respectively. Therefore, it can be concluded that simulated toothbrushing impacts on surface roughness and gloss, irrespective of the storage medium.


2020 ◽  
Author(s):  
Azam Valian ◽  
Zahra Jaber Ansari ◽  
Mohammad Moien Rezaie ◽  
Roja Askian

Abstract Background: Esthetic dental restorations have gained increasing popularity. The restoration surface should be smooth enough to prevent adhesion of microorganisms and food particles, and achieve maximum esthetics. This study aimed to assess the surface roughness and color change of composite specimens following the use of an airflow device. Methods: In this in vitro, experimental study, 30 Tokuyama composite discs were fabricated and randomly divided into three groups (n=10) for the use of airflow with calcium carbonate powder, airflow with sodium bicarbonate powder, and conventional polishing with FlexiDisc. The surface roughness of specimens was measured by profilometry while the color change was evaluated by measuring the L*, a* and b* color parameters by spectrophotometry before polishing (T1). The composite specimens were then polished for stain removal and their surface roughness and color parameters were measured again after polishing (T2). Paired t-test and Tukey’s test were applied for within-group and between-group comparisons.Results: Significant differences were noted in surface roughness (Ra) between airflow with calcium carbonate (0.251 ± 0.014 µm) and airflow with sodium bicarbonate (0.421 ± 0.208 µm), and also between airflow with sodium bicarbonate and FlexiDisc (0.207 ± 0.076 µm) groups after polishing (P<0.05). Regarding the correlation of change in surface roughness and color parameters at T1 and T2, an inverse correlation was noted between the change in surface roughness and all color parameters except for L*. In other words, increasing the surface roughness difference (surface smoothing), decreased the a* and b* color parameters. Conclusions: Within the limitations of this study, the results showed that the airflow device used in this study had no significant difference with the conventional polishing in terms of reduction in surface roughness and staining. Considering the cost and maintenance of the airflow device, it is not suggested as a suitable alternative to the conventional polishing procedures. Trial Registration Number: This is not a human subject research.


2020 ◽  
Author(s):  
Azam Valian ◽  
Zahra Jaber Ansari ◽  
Mohammad Moien Rezaie ◽  
Roja Askian

Abstract Background: Esthetic dental restorations have gained increasing popularity. The restoration surface should be smooth enough to prevent adhesion of microorganisms and food particles, and achieve maximum esthetics. This study aimed to assess the surface roughness and color change of composite specimens following the use of an airflow device. Methods: In this in vitro, experimental study, 30 Tokuyama composite discs were fabricated and randomly divided into three groups (n=10) for the use of airflow with calcium carbonate powder, airflow with sodium bicarbonate powder, and conventional polishing with FlexiDisc. The surface roughness of specimens was measured by profilometry while the color change was evaluated by measuring the L*, a* and b* color parameters by spectrophotometry before polishing (T1). The composite specimens were then polished for stain removal and their surface roughness and color parameters were measured again after polishing (T2). Paired t-test and Tukey’s test were applied for within-group and between-group comparisons.Results: Significant differences were noted in Ra (the roughness average pf surface) between airflow with calcium carbonate (0.251 ± 0.014 µm) and airflow with sodium bicarbonate (0.421 ± 0.208 µm), and also between airflow with sodium bicarbonate and FlexiDisc (0.207 ± 0.076 µm) groups after polishing (P<0.05). Regarding the correlation of change in surface roughness and color parameters at T1 and T2, an inverse correlation was noted between the change in surface roughness and all color parameters except for L*. In other words, increasing the surface roughness difference (surface smoothing), decreased the a* and b* color parameters. Conclusions: Within the limitations of this study, the results showed that the airflow device used in this study had no significant difference with the conventional polishing in terms of reduction in surface roughness and staining. Considering the cost and maintenance of the airflow device, it is not suggested as a suitable alternative to the conventional polishing procedures. Trial Registration Number: This is not a human subject research.


2016 ◽  
Vol 19 (2) ◽  
pp. 56
Author(s):  
Iris Durães ◽  
Giulian Lennon Macêdo ◽  
Cristal Fernandez Carvalho ◽  
Viviane Maia Barreto Oliveira ◽  
Emilena Maria Castor Xisto Lima

<p><strong>Objective:</strong> This in vitro study evaluated the effects of three polishing systems on the surface roughness of two ceromers. <strong>Material and Methods:</strong> 96 specimens (8 mm in diameter and 2 mm thick) were prepared in a metal mold using two restorative materials: CERAMAGE (Shofu, Japan) and VMLC VITA (VITA Zahnfabrik, Germany). The specimens were divided into 4 groups (n=12): G1: positive control, Mylar strip; G2: abrasive tips, Edenta system; G3: silicon tips, Enhance system; and G4: abrasive tips, Shofu system. The parameter evaluated was the average surface roughness (Ra) determined by using a profilometer SJ 301 (Mitutoyo, Japan), followed by photographic evaluation images through Scanning Electron Microscopy (SEM), with a 1000x magnification range. The data was subjected to statistical analysis for comparison between the groups (ANOVA, Tukey and Student T-tests), with a significance level of 5%. <strong>Results:</strong> there was a statistically significant difference between the silicone tip Enhance and the other groups for both ceromers with higher values of surface roughness. There was no statistically significant difference between the ceromers, except for the Shofu system, which showed lower values of surface roughness for Vita VMLC. <strong>Conclusion: </strong>Within the limitations of this study, it was concluded that the Edenta and Shofu abrasive tips are more effective in reducing the surface roughness of ceromers compared with the Enhance silicone tip.</p><p><strong>Keywords:</strong> Resins; Surface roughness; Dental polishing.</p>


Sign in / Sign up

Export Citation Format

Share Document