Influence of TiN coating on the biocompatibility of medical NiTi alloy

2013 ◽  
Vol 101 ◽  
pp. 343-349 ◽  
Author(s):  
Shi Jin ◽  
Yang Zhang ◽  
Qiang Wang ◽  
Dan Zhang ◽  
Song Zhang
Keyword(s):  
2010 ◽  
Vol 26 (7) ◽  
pp. 499-505 ◽  
Author(s):  
T. Abubakar ◽  
M. Rahman ◽  
D. P. Dowling ◽  
J. Stokes ◽  
M. S. J. Hashmi

Biomaterials ◽  
2014 ◽  
Vol 35 (24) ◽  
pp. 6195-6205 ◽  
Author(s):  
Dayun Yang ◽  
Xiaoying Lü ◽  
Ying Hong ◽  
Tingfei Xi ◽  
Deyuan Zhang

2014 ◽  
Vol 120 ◽  
pp. 155-158 ◽  
Author(s):  
Ying Yan ◽  
Weihu Yang ◽  
Yan Hu ◽  
Kaiyong Cai ◽  
Peng Liu

2017 ◽  
Vol 32 (11) ◽  
pp. 657-667 ◽  
Author(s):  
Qiang Wang ◽  
Song Zhang ◽  
Chunhua Zhang ◽  
Chenliang Wu ◽  
Zulai Sun

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sirapat Pipattanachat ◽  
Jiaqian Qin ◽  
Dinesh Rokaya ◽  
Panida Thanyasrisung ◽  
Viritpon Srimaneepong

AbstractBiofilm formation on medical devices can induce complications. Graphene oxide/silver nanoparticles (GO/AgNPs) coated nickel-titanium (NiTi) alloy has been successfully produced. Therefore, the aim of this study was to determine the anti-bacterial and anti-biofilm effects of a GO/AgNPs coated NiTi alloy prepared by Electrophoretic deposition (EPD). GO/AgNPs were coated on NiTi alloy using various coating times. The surface characteristics of the coated NiTi alloy substrates were investigated and its anti-biofilm and anti-bacterial effect on Streptococcus mutans biofilm were determined by measuring the biofilm mass and the number of viable cells using a crystal violet assay and colony counting assay, respectively. The results showed that although the surface roughness increased in a coating time-dependent manner, there was no positive correlation between the surface roughness and the total biofilm mass. However, increased GO/AgNPs deposition produced by the increased coating time significantly reduced the number of viable bacteria in the biofilm (p < 0.05). Therefore, the GO/AgNPs on NiTi alloy have an antibacterial effect on the S. mutans biofilm. However, the increased surface roughness does not influence total biofilm mass formation (p = 0.993). Modifying the NiTi alloy surface using GO/AgNPs can be a promising coating to reduce the consequences of biofilm formation.


2015 ◽  
Vol 2015 ◽  
pp. 1-9 ◽  
Author(s):  
Ruud P. van Hove ◽  
Inger N. Sierevelt ◽  
Barend J. van Royen ◽  
Peter A. Nolte

Surfaces of medical implants can be enhanced with the favorable properties of titanium-nitride (TiN). In a review of English medical literature, the effects of TiN-coating on orthopaedic implant material in preclinical studies were identified and the influence of these effects on the clinical outcome of TiN-coated orthopaedic implants was explored. The TiN-coating has a positive effect on the biocompatibility and tribological properties of implant surfaces; however, there are several reports of third body wear due to delamination, increased ultrahigh molecular weight polyethylene wear, and cohesive failure of the TiN-coating. This might be due to the coating process. The TiN-coating process should be optimized and standardized for titanium alloy articulating surfaces. The clinical benefit of TiN-coating of CoCrMo knee implant surfaces should be further investigated.


Author(s):  
Yan Zhang ◽  
DeShui Yu ◽  
JianPing Zhou ◽  
DaQian Sun ◽  
HongMei Li

Abstract To avoid the formation of Ti-Ni intermetallics in a joint, three laser welding processes for Ti alloy–NiTi alloy joints were introduced. Sample A was formed while a laser acted at the Ti alloy–NiTi alloy interface, and the joint fractured along the weld centre line immediately after welding without filler metal. Sample B was formed while the laser acted on a Cu interlayer. The average tensile strength of sample B was 216 MPa. Sample C was formed while the laser acted 1.2 mm on the Ti alloy side. The one-pass welding process involved the creation of a joint with one fusion weld and one diffusion weld separated by the remaining unmelted Ti alloy. The mechanical performance of sample C was determined by the diffusion weld formed at the Ti alloy–NiTi alloy interface with a tensile strength of 256 MPa.


Coatings ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 823
Author(s):  
Danko Ćorić ◽  
Mateja Šnajdar Musa ◽  
Matija Sakoman ◽  
Željko Alar

The development of cemented carbides nowadays is aimed at the application and sintering of ultrafine and nano-sized powders for the production of a variety of components where excellent mechanical properties and high wear resistance are required for use in high temperature and corrosive environment conditions. The most efficient way of increasing the tribological properties along with achieving high corrosion resistance is coating. Using surface processes (modification and/or coating), it is possible to form a surface layer/base material system with properties that can meet modern expectations with acceptable production costs. Three coating systems were developed on WC cemented carbides substrate with the addition of 10 wt.% Co using the plasma-assisted chemical vapor deposition (PACVD) method: single-layer TiN coating, harder multilayer gradient TiCN coating composed of TiN and TiCN layers, and the hardest multilayer TiBN coating composed of TiN and TiB2. Physical and mechanical properties of coated and uncoated samples were investigated by means of quantitative depth profile (QDP) analysis, nanoindentation, surface layer characterization (XRD analysis), and coating adhesion evaluation using the scratch test. The results confirm the possibility of obtaining nanostructured cemented carbides of homogeneous structure without structural defects such as eta phase or unbound carbon providing increase in hardness and fracture toughness. The lowest adhesion was detected for the single-layer TiN coating, while coatings with a complex architecture (TiCN, TiBN) showed improved adhesion.


Sign in / Sign up

Export Citation Format

Share Document