Numerical evaluation of suppression mechanism of shark-inspired riblet on tip leakage vortex of a NACA0009 hydrofoil with tip clearance

2022 ◽  
pp. 110288
Author(s):  
Like Wang ◽  
Xingqi Luo ◽  
Jianjun Feng ◽  
Jinling Lu ◽  
Guojun Zhu ◽  
...  
1995 ◽  
Vol 117 (4) ◽  
pp. 522-532 ◽  
Author(s):  
W. C. Zierke ◽  
K. J. Farrell ◽  
W. A. Straka

A high-Reynolds-number pump (HIREP) facility has been used to acquire flow measurements in the rotor blade tip clearance region, with blade chord Reynolds numbers of 3,900,000 and 5,500,000. The initial experiment involved rotor blades with varying tip clearances, while a second experiment involved a more detailed investigation of a rotor blade row with a single tip clearance. The flow visualization on the blade surface and within the flow field indicate the existence of a trailing-edge separation vortex, a vortex that migrates radially upward along the trailing edge and then turns in the circumferential direction near the casing, moving in the opposite direction of blade rotation. Flow visualization also helps in establishing the trajectory of the tip leakage vortex core and shows the unsteadiness of the vortex. Detailed measurements show the effects of tip clearance size and downstream distance on the structure of the rotor tip leakage vortex. The character of the velocity profile along the vortex core changes from a jetlike profile to a wakelike profile as the tip clearance becomes smaller. Also, for small clearances, the presence and proximity of the casing endwall affects the roll-up, shape, dissipation, and unsteadiness of the tip leakage vortex. Measurements also show how much circulation is retained by the blade tip and how much is shed into the vortex, a vortex associated with high losses.


2005 ◽  
Vol 128 (3) ◽  
pp. 421-429 ◽  
Author(s):  
Masahiro Murayama ◽  
Yoshiki Yoshida ◽  
Yoshinobu Tsujimoto

Tip leakage vortex cavitations originating from the tip clearance of an oscillating hydrofoil were observed experimentally. It was found that the delay between the unsteady and the steady-state results of the tip leakage vortex cavitation increase, and that the maximum cavity size decreases when the reduced oscillating frequency increases. To simulate the unsteady characteristics of tip leakage vortex cavitation, a simple calculation based on slender body approximation was conducted taking into account the effect of cavity growth. The calculation and experimental results of the cavity volume fluctuation were found to be in qualitative agreement.


Author(s):  
Desheng Zhang ◽  
Weidong Shi ◽  
Suqing Wu ◽  
Dazhi Pan ◽  
Peipei Shao ◽  
...  

In this paper, the tip leakage vortex (TLV) structures in an axial flow pump were investigated by numerical and experimental methods. Based on the comparisons of different blade tip clearance size (i.e., 0.5 mm, 1mm and 1.5mm) and different flow rate conditions, TLV trajectories were obtained by Swirling Strength method, and simulated by modified SST k-ω turbulence model with refined high-quality structured grids. A high-speed photography test was carried out to capture the tip leakage vortex cavitation in an axial flow pump with transparent casing. Numerical results were compared with the experimental leakage vortex trajectories, and a good agreement is presented. The detailed trajectories show that the start point of tip leakage vortex appears near the leading edge at small flow rate, and it moves from trailing edge to about 30% chord span at rated flow rate. At the larger flow rate condition, the starting point of TLV shifts to the middle of chord, and the direction of TLV moves parallel to the blade hydrofoil. As the increasing of the tip size, the start point of TLV trajectories moves to the central of chord and the minimum pressure in vortex core is gradually reduced.


Author(s):  
Masanao Kaneko ◽  
Hoshio Tsujita

A transonic centrifugal compressor impeller is generally composed of the main and the splitter blades which are different in chord length. As a result, the tip leakage flows from the main and the splitter blades interact with each other and then complicate the flow field in the compressor. In this study, in order to clarify the individual influences of these leakage flows on the flow field in the transonic centrifugal compressor stage at near-choke to near-stall condition, the flows in the compressor at four conditions prescribed by the presence and the absence of the tip clearances were analyzed numerically. The computed results clarified the following noticeable phenomena. The tip clearance of the main blade induces the tip leakage vortex from the leading edge of the main blade. This vortex decreases the blade loading of the main blade to the negative value by the increase of the flow acceleration along the suction surface of the splitter blade, and consequently induces the tip leakage vortex caused by the negative blade loading of the main blade at any operating points. These phenomena decline the impeller efficiency. On the other hand, the tip clearance of the splitter blade decreases the afore mentioned acceleration by the formation of the tip leakage vortex from the leading edge of the splitter blade and the decrease of the incidence angle for the splitter blade caused by the suction of the flow into the tip clearance. These phenomena reduce the loss generated by the negative blade loading of the main blade and consequently reduce the decline of the impeller efficiency. Moreover, the tip clearances enlarge the flow separation around the diffuser inlet and then decline the diffuser performance independently of the operating points.


2013 ◽  
Vol 136 (4) ◽  
Author(s):  
William Riéra ◽  
Lionel Castillon ◽  
Julien Marty ◽  
Francis Leboeuf

In the present study, the influence of the inlet condition on the tip clearance flow of an axial compressor is investigated. Two different zonal detached eddy simulations (ZDES) computations are carried out and compared to Reynolds-averaged Navier–Stokes (RANS) and unsteady RANS (URANS) computations as well as to experimental data. A rotating distortion map of the flow cartography is set as inlet condition for the first ZDES computation. An azimuthally averaged inlet condition is used for the second one and uncouples the rotor tip-leakage vortex flutter phenomenon, which stems from the arrival of the inlet guide vane wake from the behavior inherent to the rotor tip-leakage vortex. In the studied configuration, the inlet guide vane tip vortex reveals to lower the effects from double leakage on the rotor. The topology of the rotor tip-leakage vortex is described, and its development is analyzed.


2019 ◽  
Vol 141 (8) ◽  
Author(s):  
Yabin Liu ◽  
Lei Tan

Tip clearance in pump induces tip leakage vortex (TLV), which interacts with the main flow and leads to instability of flow pattern and decrease of pump performance. In this work, the characteristics of TLV in a mixed-flow pump are investigated by the numerical simulation using shear stress transport (SST) k–ω turbulence model with experimental validation. The trajectory of the primary tip leakage vortex (PTLV) is determined, and a power function law is proposed to describe the intensity of the PTLV core along the trajectory. Spatial–temporal evolution of the TLV in an impeller revolution period T can be classified into three stages: splitting stage, developing stage, and merging stage. The TLV oscillation period TT is found as 19/160 T, corresponding to the frequency 8.4 fi (fi is impeller rotating frequency). Results reveal that the TLV oscillation is intensified by the sudden pressure variation at the junction of two adjacent blades. On analysis of the relative vorticity transport equation, it is revealed that the relative vortex stretching item in Z direction is the major source of the splitting and shedding of the PTLV. The dominant frequency of pressure and vorticity fluctuations on the PTLV trajectory is 8.4 fi, same as the TLV oscillation frequency. This result reveals that the flow instability in the PTLV trajectory is dominated by the oscillation of the TLV. The blade number has significant effect on pressure fluctuation in tip clearance and on blade pressure side, because the TLV oscillation period varies with the circumferential length of flow passage.


Author(s):  
Zhibo Zhang ◽  
Xianjun Yu ◽  
Baojie Liu

The detailed evolutionary processes of the tip leakage flow/vortex inside the rotor passage are still not very clear for the difficulties of investigating of them by both experimental and numerical methods. In this paper, the flow fields near the rotor tip region inside the blade passage with two tip gaps, 0.5% and 1.5% blade height respectively, were measured by using stereoscopic particle image velocimetry (SPIV) in a large-scale low speed axial compressor test facility. The measurements are conducted at four different operating conditions, including the design, middle, maximum static pressure rise and near stall conditions. In order to analyze the variations of the characteristics of the tip leakage vortex (TLV), the trajectory, concentration, size, streamwise velocity, and the blockage parameters are extracted from the ensemble-averaged results and compared at different compressor operating conditions and tip gaps. The results show that the formation of the TLV is delayed with large tip clearance, however, its trajectory moves much faster in an approximately linear way from the blade suction side to pressure side. In the tested compressor, the size of the tip gap has little effects on the scale of the TLV in the spanwise direction, on the contrary, its effects on the pitch-wise direction is very prominent. Breakdown of the TLV were both found at the near-stall condition with different tip gaps. The location of the initiation of the TLV breakdown moves downstream from the 60% chord to 70% chord as the tip gap increases. After the TLV breakdown occurs, the flow blockage near the rotor tip region increases abruptly. The peak value of the blockage effects caused by the TLV breakdown is doubled with the tip gap size increasing from 0.5% to 1.5% blade span.


Author(s):  
Xiaocheng Zhu ◽  
Wanlai Lin ◽  
Zhaohui Du

The flow field in the tip region of an axial ventilation fan is investigated with a PIV (Particle Image Velocimeter) system at the design condition. Characteristics of a ventilation fan are an extreme low-pressure difference and a large tip clearance with a low rotating speed. Flow fields with three different tip clearances are surveyed on three different circumferential planes, respectively. The phase-locked average method is used to investigate the generation and the development of a tip leakage vortex. The result from PIV system is compared with that from a PDA (Particle Dynamics Anemometer) system. Both data are in good agreement. The structure of the tip leakage vortex for the rotor is illustrated. The characteristic of a leakage vortex is described in both velocity vectors and vortical contours. It is found that the tip leakage flow for a low speed and a low pressure ventilation fan also has a chance to roll up into a discrete vortex at three different tip clearances, which is similar to high speed and high-pressure compressors and turbines. When the tip clearance increases, the scope and the location variation for the tip leakage vortex increase. Finally, the trajectories of the tip leakage vortex by the experimental measurement are compared with predictions from the existing models for high speed and high-pressure compressors and turbines. A good agreement is obtained.


Author(s):  
K. Yamada ◽  
K. Funazaki ◽  
H. Sasaki

The purpose of this study is to have a better understanding of the unsteady behavior of tip clearance flow at near-stall condition from a multi-passage simulation and to clarify the relation between such unsteadiness and rotating disturbance. This study is motivated by the following concern. A single passage simulation has revealed the occurrence of the tip leakage vortex breakdown at near-stall condition in a transonic axial compressor rotor, leading to the unsteadiness of the tip clearance flow field in the rotor passage. These unsteady flow phenomena were similar to those in the rotating instability, which is classified in one of the rotating disturbances. In other words it is possible that the tip leakage vortex breakdown produces a rotating disturbance such as the rotating instability. Three-dimensional unsteady RANS calculation was conducted to simulate the rotating disturbance in a transonic axial compressor rotor (NASA Rotor 37). The four-passage simulation was performed so as to capture a short length scale disturbance like the rotating instability and the spike-type stall inception. The simulation demonstrated that the unsteadiness of tip leakage vortex, which was derived from the vortex breakdown at near-stall condition, invoked the rotating disturbance in the rotor, which is similar to the rotating instability.


Author(s):  
Donghyun You ◽  
Meng Wang ◽  
Parviz Moin ◽  
Rajat Mittal

The tip-clearance flow in axial turbomachines is studied using large-eddy simulation with particular emphasis on understanding the underlying mechanisms for viscous losses in the end-wall region and the unsteady characteristics of the tip-leakage vortical structures. Systematic and detailed analysis of the mean flow field and turbulence statistics has been made in a linear cascade with a moving end-wall. The tip-leakage jet and tip-leakage vortex are found to produce significant mean velocity gradients, leading to the production of vorticity and turbulent kinetic energy. These are the major causes for viscous losses in the cascade end-wall region. An analysis of the energy spectra and space-time correlations of the velocity fluctuations suggests that the tip-leakage vortex is subject to a pitchwise low frequency wandering motion.


Sign in / Sign up

Export Citation Format

Share Document