Novel FIB-based sample preparation technique for TEM analysis of ultra-thin gate oxide breakdown

2002 ◽  
Vol 42 (9-11) ◽  
pp. 1753-1757 ◽  
Author(s):  
Joachim C. Reiner ◽  
Philippe Gasser ◽  
Urs Sennhauser
Author(s):  
L. A. Giannuzzi ◽  
P. R. Howell ◽  
H. W. Pickering ◽  
W. R. Bitler

A primary concern involving transmission electron microscopy (TEM) analysis is whether the electron transparent region under investigation is representative of the bulk material. TEM is frequently employed to examine the microstructure of electrodeposited materials due to their small grain size and high dislocation density. Previous work in this laboratory on palladium electrodeposits has shown that deformation twins and diffusion induced recrystallization may be induced during preparation of thin foils using both twin jet electropolishing and ion beam thinning. Recent developments in TEM sample preparation in the physical sciences include a procedure for the cross-section of heterogeneous layered materials which reduces or eliminates the need for ion milling. In this sample preparation technique, a tripod polisher device is used to mechanically polish the specimen to electron transparency. The purpose of this paper is to report on the influence of the tripod polisher sample preparation technique, on the microstructure of zinc electrodeposits.


Author(s):  
Lakshminarayanan Lakshmanan ◽  
Lowell Herlinger ◽  
Kathryn Miller

Abstract Shrinking gate lengths have led to increased challenges in isolating defects using conventional physical failure analysis methods. Conducting atomic force microscopy (CAFM) has been proven to be a powerful tool to isolate gate oxide defects in silicon-on-insulator devices. Some sample preparation techniques of exposing polysilicon and gate oxide, which were critical to perform CAFM scan, are discussed in this paper.


Author(s):  
Jayesh Bellare

Seeing is believing, but only after the sample preparation technique has received a systematic study and a full record is made of the treatment the sample gets.For microstructured liquids and suspensions, fast-freeze thermal fixation and cold-stage microscopy is perhaps the least artifact-laden technique. In the double-film specimen preparation technique, a layer of liquid sample is trapped between 100- and 400-mesh polymer (polyimide, PI) coated grids. Blotting against filter paper drains excess liquid and provides a thin specimen, which is fast-frozen by plunging into liquid nitrogen. This frozen sandwich (Fig. 1) is mounted in a cooling holder and viewed in TEM.Though extremely promising for visualization of liquid microstructures, this double-film technique suffers from a) ireproducibility and nonuniformity of sample thickness, b) low yield of imageable grid squares and c) nonuniform spatial distribution of particulates, which results in fewer being imaged.


Author(s):  
Stanley J. Klepeis ◽  
J.P. Benedict ◽  
R.M Anderson

The ability to prepare a cross-section of a specific semiconductor structure for both SEM and TEM analysis is vital in characterizing the smaller, more complex devices that are now being designed and manufactured. In the past, a unique sample was prepared for either SEM or TEM analysis of a structure. In choosing to do SEM, valuable and unique information was lost to TEM analysis. An alternative, the SEM examination of thinned TEM samples, was frequently made difficult by topographical artifacts introduced by mechanical polishing and lengthy ion-milling. Thus, the need to produce a TEM sample from a unique,cross-sectioned SEM sample has produced this sample preparation technique.The technique is divided into an SEM and a TEM sample preparation phase. The first four steps in the SEM phase: bulk reduction, cleaning, gluing and trimming produces a reinforced sample with the area of interest in the center of the sample. This sample is then mounted on a special SEM stud. The stud is inserted into an L-shaped holder and this holder is attached to the Klepeis polisher (see figs. 1 and 2). An SEM cross-section of the sample is then prepared by mechanically polishing the sample to the area of interest using the Klepeis polisher. The polished cross-section is cleaned and the SEM stud with the attached sample, is removed from the L-shaped holder. The stud is then inserted into the ion-miller and the sample is briefly milled (less than 2 minutes) on the polished side. The sample on the stud may then be carbon coated and placed in the SEM for analysis.


Author(s):  
Pradip Sairam Pichumani ◽  
Fauzia Khatkhatay

Abstract Silicon photonics is a disruptive technology that aims for monolithic integration of photonic devices onto the complementary metal-oxide-semiconductor (CMOS) technology platform to enable low-cost high-volume manufacturing. Since the technology is still in the research and development phase, failure analysis plays an important role in determining the root cause of failures seen in test vehicle silicon photonics modules. The fragile nature of the test vehicle modules warrants the development of new sample preparation methods to facilitate subsequent non-destructive and destructive analysis methods. This work provides an example of a single step sample preparation technique that will reduce the turnaround time while simultaneously increasing the scope of analysis techniques.