Predicting milk yield in Pelibuey ewes from the udder volume measurement with a simple method

2020 ◽  
Vol 87 (3) ◽  
pp. 341-343
Author(s):  
Roger Iván Espinosa-Mendoza ◽  
Darwin Nicolas Arcos-Álvarez ◽  
Ricardo Alfonso Garcia-Herrera ◽  
Gamaliel Antonio-Molina ◽  
Ricardo Vicente-Pérez ◽  
...  

AbstractIn this research communication we describe the creation of an equation for the prediction of milk yield (MY) from udder volume (UV). A total of 280 measurements were collected between 5 and 15 d postpartum (pp) from 36 multiparous Pelibuey ewes. Study variables were measured between 2 and 9 weeks pp and MY was measured by manual milking, UV prior to and following milking was measured using the technique of making moulds from aluminium foil. The MY ranged from 0.09 to 0.83 kg/d, meanwhile UV prior and following milking ranged from 155 to 1940 and 90 to 1520 cm3, respectively. Measurements of UV had a moderate to high (P < 0.01; 0.58 ≤ r ≤ 0.78) correlation with MY. The UV prior to milking was the best prediction model for MY, which explained 62% of the variation in MY. This equation presented moderate precision (r2 = 0.61) and high accuracy (bias correction factor = 0.94), confirming a good reproducibility index (concordance correlation coefficient = 0.73). Modelling efficiency (MEF = 0.59) showed moderate concordance between observed and predicted values. In conclusion, MY in lactating Pelibuey ewes could be predicted in a moderate way using the predictor variable UV measured with the technique of moulds made with aluminium foil.

Author(s):  
Phillip A Lancaster ◽  
Luis O Tedeschi ◽  
Zach Buessing ◽  
Michael E Davis

Abstract Nutrition models are important tools in management decisions, but improvements are needed for cow-calf producers to accurately predict nursing calf performance. Therefore, the objective of this study was to assess the ability of published milk yield and forage intake equations to predict calf feed intake and weaning weight using an independent, multi-breed dataset. A dataset with 406 nursing calves was used to evaluate two milk yield (MY) equations: 1) (NASEM) National Academies of Sciences, Engineering, and Medicine (2016) and 2) (WOOD) Wood (1967), and five feed intake equations: 1) (TED06) equations from Table 9.1 in Tedeschi et al. (2006), 2) (BAK76) equations 2 to 7 in Baker et al. (1976), 3) (TED09A) equation 25 in Tedeschi and Fox (2009), 4) (TED09B) equations 17, 19, and 24 in Tedeschi and Fox (2009), and 5) (HOL82) equation from Holloway et al. (1982). Milk yield was measured at 14-d intervals by hand milking, and individual feed intake of nursing calves was determined during a 240-d nursing period. Calf birth and weaning weight (WW) were measured on d 0 and 240, respectively. Each combination of milk yield and feed intake equation was used to predict calf feed intake and WW from observed milk yield, calf birth weight, and calf slaughter weight. Predicted and observed values were compared using concordance correlation coefficient (CCC) and mean bias (MB). Factors affecting the deviation between observed and predicted values were analyzed using regression, and a revised equation was developed. Feed intake equations poorly predicted observed feed intake with CCC &lt; 0.4 and MB ranged from -108 to 69%. However, statistics were slightly improved when using WOOD rather than the NASEM MY equation. BAK76 and TED09B feed intake equations were considerably more accurate (MB = -14.4 to 13.0%) in predicting feed intake, but still not precise (CCC &lt; 0.30). Predictions of WW had CCC ranging from 0.19 to 0.71 and MB ranging from -25.9 to 41.8% and were not significantly affected by the MY equation. TED06 and BAK76 feed intake equations were the most precise (CCC &gt; 0.60) and accurate (MB = 1.7 to 8.5%) in predicting WW. Sire breed accounted for significant variation in the deviation between observed and predicted values of feed intake, and in a revised equation to predict total feed energy intake from total milk energy intake. In conclusion, refinements of feed intake equations for nursing calves need to account for breed to improve current nutrition models.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ana Elena Rodríguez-Rodríguez ◽  
Sergio Luis-Lima ◽  
Javier Donate-Correa ◽  
Laura Diaz-Martín ◽  
María Rosa Arnau ◽  
...  

AbstractThere is no simple method to measure glomerular filtration rate (GFR) in mice, which limits the use of mice in models of renal diseases. We aimed at simplifying the plasma clearance of iohexol in mice, using dried blood spot (DBS) sampling in order to reduce the amount of blood taken for analysis. GFR was measured simultaneously by a reference method in total blood—as described before—and tested method using DBS in fifteen male and six female C57BL/6J mice. Total blood extraction was 50 μL for the reference methods and 25μL for the tested methods, distributed in 5 samples. The agreement of GFR values between both methods was analyzed with the concordance correlation coefficient (CCC), total deviation index (TDI) and coverage probability (CP). The agreement between both methods was excellent, showing a TDI = 8.1%, which indicates that 90% of the GFR values obtained with DBS showed an error ranging from − 8 to + 8% of the reference method; a CCC of 0.996 (CI: 0.992), reflecting high precision and accuracy and a CP of 94 (CI: 83), indicating that 6% of the GFR values obtained with DBS had an error greater than 10% of the method in blood. So, both methods are interchangeable. DBS represent a major simplification of GFR measurement in mice. Also, DBS improves animal welfare by reducing the total blood required and refining the procedure.


2021 ◽  
Vol 11 (2) ◽  
pp. 145
Author(s):  
Marco Mancuso ◽  
Valerio Sveva ◽  
Alessandro Cruciani ◽  
Katlyn Brown ◽  
Jaime Ibáñez ◽  
...  

Electroencephalographic (EEG) signals evoked by transcranial magnetic stimulation (TMS) are usually recorded with passive electrodes (PE). Active electrode (AE) systems have recently become widely available; compared to PE, they allow for easier electrode preparation and a higher-quality signal, due to the preamplification at the electrode stage, which reduces electrical line noise. The performance between the AE and PE can differ, especially with fast EEG voltage changes, which can easily occur with TMS-EEG; however, a systematic comparison in the TMS-EEG setting has not been made. Therefore, we recorded TMS-evoked EEG potentials (TEPs) in a group of healthy subjects in two sessions, one using PE and the other using AE. We stimulated the left primary motor cortex and right medial prefrontal cortex and used two different approaches to remove early TMS artefacts, Independent Component Analysis and Signal Space Projection—Source Informed Recovery. We assessed statistical differences in amplitude and topography of TEPs, and their similarity, by means of the concordance correlation coefficient (CCC). We also tested the capability of each system to approximate the final TEP waveform with a reduced number of trials. The results showed that TEPs recorded with AE and PE do not differ in amplitude and topography, and only few electrodes showed a lower-than-expected CCC between the two methods of amplification. We conclude that AE are a viable solution for TMS-EEG recording.


2007 ◽  
Vol 26 (16) ◽  
pp. 3095-3113 ◽  
Author(s):  
Tonya S. King ◽  
Vernon M. Chinchilli ◽  
Josep L. Carrasco

2016 ◽  
Vol 310 (5) ◽  
pp. H619-H627 ◽  
Author(s):  
Christopher J. Broyd ◽  
Sukhjinder Nijjer ◽  
Sayan Sen ◽  
Ricardo Petraco ◽  
Siana Jones ◽  
...  

Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. −13.8 ± 7.1 × 104 W·m−2·s−2, concordance correlation coefficient (CCC): 0.73, P < 0.01; cumulative: −64.4 ± 32.8 vs. −59.4 ± 34.2 × 102 W·m−2·s−1, CCC: 0.66, P < 0.01], but smaller waves were underestimated noninvasively. Increased left ventricular mass correlated with a decreased noninvasive BDW fraction ( r = −0.48, P = 0.02). Exercise increased the BDW: at maximum exercise peak BDW was −47.0 ± 29.5 × 104 W·m−2·s−2 ( P < 0.01 vs. rest) and cumulative BDW −19.2 ± 12.6 × 103 W·m−2·s−1 ( P < 0.01 vs. rest). The BDW can be measured noninvasively with acceptable reliably potentially simplifying assessments and increasing the applicability of coronary WIA.


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Joshua Shur ◽  
Matthew Blackledge ◽  
James D’Arcy ◽  
David J. Collins ◽  
Maria Bali ◽  
...  

Abstract Purpose To evaluate robustness and repeatability of magnetic resonance imaging (MRI) texture features in water and tissue phantom test-retest study. Materials and methods Separate water and tissue phantoms were imaged twice with the same protocol in a test-retest experiment using a 1.5-T scanner. Protocols were acquired to favour signal-to-noise ratio and resolution. Forty-six features including first order statistics and second-order texture features were extracted, and repeatability was assessed by calculating the concordance correlation coefficient. Separately, base image noise and resolution were manipulated in an in silico experiment, and robustness of features was calculated by assessing percentage coefficient of variation and linear correlation of features with noise and resolution. These simulation data were compared with the acquired data. Features were classified by their degree (high, intermediate, or low) of robustness and repeatability. Results Eighty percent of the MRI features were repeatable (concordance correlation coefficient > 0.9) in the phantom test-retest experiment. The majority (approximately 90%) demonstrated a strong or intermediate correlation with image acquisition parameter, and 19/46 (41%) and 13/46 (28%) of features were highly robust to noise and resolution, respectively (coefficient of variation < 5%). Agreement between the acquired and simulation data varied, with the range of agreement within feature classes between 11 and 92%. Conclusion Most MRI features were repeatable in a phantom test-retest study. This phantom data may serve as a lower limit of feature MRI repeatability. Robustness of features varies with acquisition parameter, and appropriate features can be selected for clinical validation studies.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1423.2-1424
Author(s):  
J. A. Mendonça ◽  
I. Siste de Almeida Aoki ◽  
C. C. Cavuto ◽  
V. A. Leandro-Merhi ◽  
J. L. B. D. Aquino

Background:The gray scale (GS) in high resolution ultrasound is already well validated for use in rheumatological diseases, but the color map or the histogram, can be considered a new proposal, to better define and complement the echotextural damages detection1.Objectives:To calculate the lesions area measures reproducibility index in arthropathies, between 3 blind evaluators and correlate these measures using the GS and the histogram.Methods:Observational and retrospective study approved by the ethics committee of the Pontifical Catholic University of Campinas, with the opinion number: 1.526.307. A total of 29 patients have been assessed (31% males and 69% females) on period 2014 to 2019 in Rheumatology service. A MyLab 50 -Esaote equipment was used with frequency transducer that ranged between 6.0 and 18.0 MHz, 10 different area measures were performed from each recorded images previously, by the GS and the histogram. Statistical analysis: Spearman’s correlation coefficients, Lin’s concordance coefficient (CCC) and the intraclass correlation coefficient (ICC) and their respective 95% confidence intervals, with the SPSS software package for Windows v. 17.0 (SPSS Inc., Chicago, IL, USA).Results:Average age 43.5 ± 21.5 years of age; with disease duration that varied between ≤ 1 month (48.3%) and ≥36 months (24.1%); with the following diseases: juvenile idiopathic arthritis (17.24%); osteoarthritis (13.79%); psoriatic arthritis (13.79%); undifferentiated spondyloarthritis (3.44%); gout (20.68%); rheumatoid arthritis (27.58%) and reactive arthritis (3.44%). A total of 840 measures of exudative (27.58%), proliferative (27.58%) and snowstorm appearance (6.89%) synovitis were performed; femoral-condyle cartilage (3.44%); synovial cyst (3.44%); paratendinitis (6.89%); calcification (3.44%); nail enthesitis (3.44%); tenosynovitis (6.89%) and tophi (10.34%) (Figure 1). The concordance correlation coefficient showed values closer to 1; p <0.001, the intraclass correlation coefficients with excellent reproducibility (ICC ≥ 0.75); p <0.001, always in relation to the three evaluators (Table 1) and the Spearman correlation between the GS and the histogram ranged from rs = 0.665 to rs = 1,000; p <0.001.Conclusion:The histogram can be considered an image method to better identify echotextural damages.References:[1]Mendonça J, Provenza J, Guissa V, et al AB1059 2D Histogram Ultrasound and 3D Ultrasound Correlation in Rheumatic Diseases Annals of the Rheumatic Diseases 2015; 74:1253-1254.Table 1.Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC):EvaluatorsGS - CCC(IC 95%)p-valorHistogram (IC 95%)p-valor1 e 20,998(0,994-0,999)<0,0010,999(0,995-1,000)<0,0011 e 30,998(0,995-0,999)<0,0010,999(0,995-1,000)<0,0012 e 30,992(0,980-0,997)<0,010,996(0,979-0,999)<0,01Standard by US 2DICCp-valorGS0,997(0,992-0,999)<0,001Histogram0,998(0,992-0,999)<0,001Legends: Gray Scale (GS).Figure 1.Patient with gout: A and B: Tophi area measures (star) in right metatarsos and efusion (arrow) by GS (45 mm2) and histogram (39 mm2), respectively.Disclosure of Interests:José Alexandre Mendonça Speakers bureau: Novartis, Janssen, Bristol, UCB, Isabella Siste de Almeida Aoki: None declared, Caique Chagas Cavuto: None declared, Vânia Aparecida Leandro-Merhi: None declared, José Luis Braga de Aquino: None declared


Author(s):  
Dai Feng ◽  
Richard Baumgartner ◽  
Vladimir Svetnik

Abstract The concordance correlation coefficient (CCC) is a widely used scaled index in the study of agreement. In this article, we propose estimating the CCC by a unified Bayesian framework that can (1) accommodate symmetric or asymmetric and light- or heavy-tailed data; (2) select model from several candidates; and (3) address other issues frequently encountered in practice such as confounding covariates and missing data. The performance of the proposal was studied and demonstrated using simulated as well as real-life biomarker data from a clinical study of an insomnia drug. The implementation of the proposal is accessible through a package in the Comprehensive R Archive Network.


2020 ◽  
Vol 50 (3) ◽  
Author(s):  
Anne Pinheiro Costa ◽  
José Ricardo Peixoto ◽  
Luiz Eduardo Bassay Blum ◽  
Alexandre Bosco de Oliveira

ABSTRACT: The study aimed to develop and validate a standard area diagram set (SADs) to improve accuracy, precision, and reproducibility in the assessment of scab severity in trilobed leaves of the sour passion fruit. The SADs comprised six severity levels (1%; 3%; 6%; 11%; 21%; and 33%). The SADs increased the accuracy of the estimates by reducing the constant and systematic errors, and the tendency to overestimate the actual severity, limited the number of evaluators who presented this trend, in addition to increasing the bias correction factor. The inexperienced evaluators were the ones that benefited the most from the SADs use. Once the SADs was introduced, 80% and 100% evaluators gave estimates free from constant and systematic errors, respectively. The improvement in precision was verified by the increase in the coefficient of determination and Lin’s concordance correlation coefficient, by reducing absolute errors and increasing the reproducibility of the estimates.


PLoS ONE ◽  
2021 ◽  
Vol 16 (4) ◽  
pp. e0250334
Author(s):  
Choong Guen Chee ◽  
Hye Won Chung ◽  
Wanlim Kim ◽  
Min A. Yoon ◽  
So Myoung Shin ◽  
...  

Purpose To evaluate the osseous anatomy of the proximal femur extracted from a 3D-MRI volumetric interpolated breath-hold (VIBE) sequence using either a Dixon or water excitation (WE) fat suppression method, and to measure the overall difference using CT as a reference standard. Material and methods This retrospective study reviewed imaging of adult patients with hip pain who underwent 3D hip MRI and CT. A semi-automatically segmented CT model served as the reference standard, and MRI segmentation was performed manually for each unilateral hip joint. The differences between Dixon-VIBE-3D-MRI vs. CT, and WE-VIBE-3D-MRI vs. CT, were measured. Equivalence tests between Dixon-VIBE and WE-VIBE models were performed with a threshold of 0.1 mm. Bland–Altman plots and Lin’s concordance-correlation coefficient were used to analyze the agreement between WE and Dixon sequences. Subgroup analyses were performed for the femoral head/neck, intertrochanteric, and femoral shaft areas. Results The mean and maximum differences between Dixon-VIBE-3D-MRI vs. CT were 0.2917 and 3.4908 mm, respectively, whereas for WE-VIBE-3D-MRI vs. CT they were 0.3162 and 3.1599 mm. The mean differences of the WE and Dixon methods were equivalent (P = 0.0292). However, the maximum difference was not equivalent between the two methods and it was higher in WE method. Lin’s concordance-correlation coefficient showed poor agreement between Dixon and WE methods. The mean differences between the CT and 3D-MRI models were significantly higher in the femoral shaft area (P = 0.0004 for WE and P = 0.0015 for Dixon) than in the other areas. The maximum difference was greatest in the intertrochanteric area for both techniques. Conclusion The difference between 3D-MR and CT models were acceptable with a maximal difference below 3.5mm. WE and Dixon fat suppression methods were equivalent. The mean difference was highest at the femoral shaft area, which was off-center from the magnetization field.


Sign in / Sign up

Export Citation Format

Share Document