scholarly journals Two-dimensional heat transfer analysis of timber structure walls filled with hemp-lime composite

2019 ◽  
Vol 252 ◽  
pp. 05015 ◽  
Author(s):  
Przemysław Brzyski ◽  
Sylwia Duda ◽  
Andrzej Raczkowski

Hemp-lime composite is a thermal insulating material used as a filling in timber frame construction walls. It is a material based on the wooden part of industrial hemp stalk (hemp shives) and lime binder. In practice, different wall thicknesses, composites with different thermal properties and various configurations of timber structure are used. These factors affect the temperature distribution in the wall. In the thermally weaker areas of walls, there is a greater risk of condensation and mould growth. This issue is important while designing walls based on organic materials. The paper presents the two-dimensional (2D) heat-transfer analysis based on the finite-element method, using THERM software. Several variants of external walls were adopted for the analysis. Thermal parameters of hemp-lime composites used in the analysis were obtained from our own research. The results of the analysis were presented as the values of the thermal transmittance coefficient and linear thermal transmittance equivalent to timber construction. The temperature distribution for an exemplary wall was also shown graphically in the form of isotherms and colour-flooded isotherms.

Materials ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2392 ◽  
Author(s):  
Brzyski ◽  
Grudzińska ◽  
Majerek

This article analyses the connection of the two types of floors on the ground (floors on joists and self-supporting floors), with the external wall made of a hemp–lime composite for the occurrence of thermal bridges. Several factors that may affect the heat transfer in the junction were taken into account: the level of the floor on the ground, the wall thickness, the thermal conductivity of the composite, and the location of the timber frame construction. The technology of using hemp and lime is relatively new, and there is a lack of such analyses in the literature. The two-dimensional (2D) heat-transfer in the described construction joints was analyzed based on the finite-element method with the use of the THERM 7.4 software. The results were presented as averaged and linear thermal transmittance coefficients dependent on the above mentioned factors. The possibility of surface condensation was also checked. The differences in the values of the thermal transmittance of the junction between the two variants of ground floors reached around 0.13%–1.67% and the values of linear thermal transmittance factor reached approximately 2.43%–10.13%. The junctions with the highest floor level showed a decrease in the thermal transmittance value by about 3.00%–5.77% and in the linear thermal transmittance, by about 21.98%–53.83%, compared to the junctions with the lowest floor level. Calculations showed that almost all analyzed junctions are free from surface condensation causing mould growth, because the minimum temperature factors f0.25 were higher than 0.78 (except for junctions with the lowered floor levels). The junction with a floor on the timber joists showed better thermal parameters than the junction with a self-supporting floor in each of the analyzed variants. By increasing the level of floor insulation, it is possible to limit the thermal bridges and improve the thermal properties of the junction.


Author(s):  
Si-Hwa Jeong ◽  
Min-Gu Won ◽  
Nam-Su Huh ◽  
Yun-Jae Kim ◽  
Young-Jin Oh ◽  
...  

In this paper, the thermal stress characteristics of the pipe-in-pipe (PIP) system under high temperature condition are analyzed. The PIP is a type of pipe applied in sodium-cooled faster reactor (SFR) and has a different geometry from a single pipe. In particular, under the high temperature condition of the SFR, the high thermal stress is generated due to the temperature gradient occurring between the inner pipe and outer pipe. To investigate the thermal stress characteristics, three cases are considered according to geometry of the support. The fully constrained support and intermediate support are considered for case 1 and 2, respectively. For case 3, both supports are applied to the actual curved pipe. The finite element (FE) analyses are performed in two steps for each case. Firstly, the heat transfer analysis is carried out considering the thermal conduction, convection and radiation conditions. From the heat transfer analysis, the temperature distribution results in the piping system are obtained. Secondly, the structural analysis is performed considering the temperature distribution results and boundary conditions. Finally, the effects of the geometric characteristics on the thermal stress in the PIP system are analyzed.


Author(s):  
Shigeki Hirasawa ◽  
Hiroyuki Ishibashi ◽  
Kazuhisa Kurashige ◽  
Akihiro Gunji

Temperature distributions and thermal stress distributions in a semi-transparent GSO crystal during Czochralski (CZ) single crystal growth were numerically investigated by thermal radiation heat transfer analysis and anisotropy stress analysis. As GSO has special optical properties, such as semi-transparency at a wavelength shorter than 4.5 μm, thermal radiation heat transfer was calculated by the Monte Carlo method. These calculations showed that thermal stress is caused by the radial temperature distribution on the outside of the upper part of the crystal. To reduce this temperature distribution, the following three manufacturing conditions were found to be effective: use a sharp taper angle of the crystal, install a lid to the top of the insulator, and install a ring around the tapered part of the crystal.


Solar Energy ◽  
1988 ◽  
Vol 40 (2) ◽  
pp. 127-133 ◽  
Author(s):  
N.E. Wijeysundera ◽  
V. Thevendran

2012 ◽  
Vol 204-208 ◽  
pp. 2236-2239 ◽  
Author(s):  
Bo Chen ◽  
Wei Hua Guo ◽  
Chun Fang Song ◽  
Kai Kai Lu

Bridge tower, time-varying temperature field, heat transfer analysis, finite element model. Abstract. Long span suspension bridges are subjected to daily, seasonal and yearly environmental thermal effects induced by solar radiation and ambient air temperature. This paper aims to investigate the temperature distribution of a tower of a long span suspension bridge. Two-dimensional heat transfer models are utilized to determine the time-dependent temperature distribution of the bridge tower of the bridge. The solar radiation model is utilized to examine the time-varying temperature distribution. Finite element models are constructed for the bridge tower to compute the temperature distribution. The numerical models can successfully predict the structural temperature field at different time. The methodology employed in the paper can be applied to other long-span bridges as well.


Author(s):  
Tomohiko Yamaguchi ◽  
Kuniyasu Kanemaru ◽  
Satoru Momoki ◽  
Toru Shigechi ◽  
Ryo Fujiwara

The solid-gas or liquid-gas two phase flow has many industrial applications such as spray drying, pollution control, transport systems, fluidized beds, energy conversion and propulsion, material processing, and so on. Though the solid-gas multiphase flow has been studied experimentally and numerically, the transport phenomena have not been cleared due to its complexity, computational time and economical costs for the hardware. In this study the heat and mass transfer of solid-gas collision dominated flow is analyzed by the Discrete Particle Simulation (DPS), a kind of the Dispersed Element Method (DEM)[1]. This method describes the discrete phase and the continuous phase by Lagrange and Euler methods respectively, and has been used to simulate the multiphase flow of various geometrical systems. In order to analyze the thermal field we took account of the energy equation and heat conduction between colliding particles. The heat transfer rate is summation of conductive heat transfer and convective heat transfer. Furthermore, the fluid flow has a two dimensional velocity profile, because the void fractions are analyzed as two dimensions. But momentum space has not been resolved by the two dimensional simulation. We call this method, the quasi two-dimensional simulation in this paper. To obtain the temperature distribution of the continuous phase the energy equation is solved in addition to the momentum equations. We treated the interaction between continuous and discrete phases as one and two way couplings. The positions, the momentum and the temperature information of particles and the velocity and the temperature distribution of the fluid were obtained as functions of time from results of these numerical simulations. When the hot air that is suspending small glass particles flows in a duct from bottom up, we traced the particles and got the temperature distribution of fluid and compared with the former results of one-dimensional flow. At the beginning, the cooler particles decrease the fluid temperature near the bottom of the vessel. The temperature profile of the particles obtained by the one-dimensional simulation is as same as quasi two-dimensional simulation. After 0.5 second the particles cool the downstream air. At 1.2 second, particles do not decrease the air temperature because the temperatures of particles are close to the inlet temperature of the air.


1986 ◽  
Vol 52 (476) ◽  
pp. 1734-1740 ◽  
Author(s):  
Hiroshi HAYASAKA ◽  
Kazuhiko KUDO ◽  
Hiroshi TANIGUCHI ◽  
Ichiro NAKAMACHI ◽  
Toshiaki OMORI ◽  
...  

2021 ◽  
Vol 11 (17) ◽  
pp. 8271 ◽  
Author(s):  
Cheng Chen ◽  
Ming-An Yu ◽  
Lin Qiu ◽  
Hong-Yu Chen ◽  
Zhen-Long Zhao ◽  
...  

(1) Background: Microwave ablation (MWA) is a common tumor ablation surgery. Because of the high temperature of the ablation antenna, it is strongly destructive to surrounding vital tissues, resulting in high professional requirements for clinicians. The method used to carry out temperature observation and damage prediction in MWA is significant; (2) Methods: This work employs numerical study to explore temperature distribution of typical tissues in MWA. Firstly, clinical MWA based on isolated biological tissue is implemented. Then, the Pennes models and microwave radiation physics are established based on experimental parameters and existing related research. Initial values and boundary conditions are adjusted to better meet the real clinical materials and experimental conditions. Finally, clinical MWA data test this model. On the premise that the model is matched with clinical MWA, fat and bone are deduced for further heat transfer analysis. (3) Results: Numerical study obtains the temperature distribution of biological tissue in MWA. It observes the heat transfer law of ablation antenna in biological tissue. Additionally, combined with temperature threshold, it generates thermal damage of biological tissues and predicts the possible risks in MWA; (4) Conclusions: This work proposes a numerical study of typical biological tissues. It provides a new theoretical basis for clinically thermal ablation surgery.


Sign in / Sign up

Export Citation Format

Share Document